TY - JOUR A1 - Ott, M. A1 - Bender, L. A1 - Marre, R. A1 - Hacker, Jörg T1 - Pulsed field electrophoresis of genomic restriction fragments for the detection of nosocomial Legionella pneumophila in hospital water supplies N2 - Ten Legionella pneumophUa strains isolated from dift'erent sources were analyzed according to their restriction fragment patterils obtained by cle~vage of gen.omic DNA With Notl and Sftl and separation by pulsed field electrophoresis. Three L. pneumophila isolate~ from a nosocomial outbreak in Lü~k (Germany) and three other L. prreumophilll stralns independently isolated from a water tap located in the care unit where tbe patients were bospitalized 'xhibited identical restricti9n fragment profiles. Therefore, we concluded that these environment81 spee~ens were the source of the Legionnatres dlsease. Anotber two isolates from patients and two strains from the environment, all unrelated to the outJlreak described, sbowed different cleavage patterns. KW - Infektionsbiologie Y1 - 1991 UR - https://opus.bibliothek.uni-wuerzburg.de/frontdoor/index/index/docId/5292 UR - https://nbn-resolving.org/urn:nbn:de:bvb:20-opus-59672 ER -