@article{MantelFlentjeGuckenberger2013, author = {Mantel, Frederick and Flentje, Michael and Guckenberger, Matthias}, title = {Stereotactic body radiation therapy in the re-irradiation situation - a review}, series = {Radiation Oncology}, journal = {Radiation Oncology}, doi = {10.1186/1748-717X-8-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-96346}, year = {2013}, abstract = {Although locoregional relapse is frequent after definitive radiotherapy (RT) or multimodal treatments, re-irradiation is only performed in few patients even in palliative settings like e.g. vertebral metastasis. This is most due to concern about potentially severe complications, especially when large volumes are exposed to re-irradiation. With technological advancements in treatment planning the interest in re-irradiation as a local treatment approach has been reinforced. Recently, several studies reported re-irradiation for spinal metastases using SBRT with promising local and symptom control rates and simultaneously low rates of toxicity. These early data consistently indicate that SBRT is a safe and effective treatment modality in this clinical situation, where other treatment alternatives are rare. Similarly, good results have been shown for SBRT in the re-irradiation of head and neck tumors. Despite severe late adverse effects were reported in several studies, especially after single fraction doses >10 Gy, they appear less frequently compared to conventional radiotherapy. Few studies with small patient numbers have been published on SBRT re-irradiation for non-small cell lung cancer (NSCLC). Overall survival (OS) is limited by systemic progression and seems to depend particularly on patient selection. SBRT re-irradiation after primary SBRT should not be practiced in centrally located tumors due to high risk of severe toxicity. Only limited data is available for SBRT re-irradiation of pelvic tumors: feasibility and acceptable toxicity has been described, suggesting SBRT as a complementary treatment modality for local symptom control.}, language = {en} } @article{DjuzenovaElsnerKatzeretal.2013, author = {Djuzenova, Cholpon S. and Elsner, Ines and Katzer, Astrid and Worschech, Eike and Distel, Luitpold V. and Flentje, Michael and Polat, B{\"u}lent}, title = {Radiosensitivity in breast cancer assessed by the histone γ-H2AX and 53BP1 foci}, series = {Radiation Oncology}, journal = {Radiation Oncology}, doi = {10.1186/1748-717X-8-98}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-96110}, year = {2013}, abstract = {Background High expression of constitutive histone γ-H2AX, a sensitive marker of DNA damage, might be indicative of defective DNA repair pathway or genomic instability. 53BP1 (p53-binding protein 1) is a conserved checkpoint protein with properties of a DNA double-strand breaks sensor. This study explores the relationship between the clinical radiosensitivity of tumor patients and the expression/induction of γ-H2AX and 53BP1 in vitro. Methods Using immunostaining, we assessed spontaneous and radiation-induced foci of γ-H2AX and 53 BP1 in peripheral blood mononuclear cells derived from unselected breast cancer (BC) patients (n=57) undergoing radiotherapy (RT). Cells from apparently healthy donors (n=12) served as references. Results Non-irradiated cells from controls and unselected BC patients exhibited similar baseline levels of DNA damage assessed by γ-H2AX and 53BP1 foci. At the same time, the γ-H2AX assay of in vitro irradiated cells revealed significant differences between the control group and the group of unselected BC patients with respect to the initial (0.5 Gy, 30 min) and residual (2 Gy, 24 h post-radiation) DNA damage. The numbers of 53BP1 foci analyzed in 35 BC patients were significantly higher than in controls only in case of residual DNA damage. A weak correlation was found between residual foci of both proteins tested. In addition, cells from cancer patients with an adverse acute skin reaction (grade 3) to RT showed significantly increased radiation-induced γ-H2AX foci and their protracted disappearance compared to the group of BC patients with normal skin reaction (grade 0-1). The mean number of γ-H2AX foci after 5 clinical fractions was significantly higher than that before RT, especially in clinically radiosensitive patients. Conclusions The γ-H2AX assay may have potential for screening individual radiosensitivity of breast cancer patients.}, subject = {DNS-Sch{\"a}digung}, language = {en} } @article{GuckenbergerHawkinsFlentjeetal.2012, author = {Guckenberger, Matthias and Hawkins, Maria and Flentje, Michael and Sweeney, Reinhart A.}, title = {Fractionated radiosurgery for painful spinal metastases: DOSIS - a phase II trial}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-75853}, year = {2012}, abstract = {Background One third of all cancer patients will develop bone metastases and the vertebral column is involved in approximately 70 \% of these patients. Conventional radiotherapy with of 1-10 fractions and total doses of 8-30 Gy is the current standard for painful vertebral metastases; however, the median pain response is short with 3-6 months and local tumor control is limited with these rather low irradiation doses. Recent advances in radiotherapy technology - intensity modulated radiotherapy for generation of highly conformal dose distributions and image-guidance for precise treatment delivery - have made dose-escalated radiosurgery of spinal metastases possible and early results of pain and local tumor control are promising. The current study will investigate efficacy and safety of radiosurgery for painful vertebral metastases and three characteristics will distinguish this study. 1) A prognostic score for overall survival will be used for selection of patients with longer life expectancy to allow for analysis of long-term efficacy and safety. 2) Fractionated radiosurgery will be performed with the number of treatment fractions adjusted to either good (10 fractions) or intermediate (5 fractions) life expectancy. Fractionation will allow inclusion of tumors immediately abutting the spinal cord due to higher biological effective doses at the tumor - spinal cord interface compared to single fraction treatment. 3) Dose intensification will be performed in the involved parts of the vertebrae only, while uninvolved parts are treated with conventional doses using the simultaneous integrated boost concept. Methods / Design It is the study hypothesis that hypo-fractionated image-guided radiosurgery significantly improves pain relief compared to historic data of conventionally fractionated radiotherapy. Primary endpoint is pain response 3 months after radiosurgery, which is defined as pain reduction of ≥2 points at the treated vertebral site on the 0 to 10 Visual Analogue Scale. 60 patients will be included into this two-centre phase II trial. Conclusions Results of this study will refine the methods of patient selection, target volume definition, treatment planning and delivery as well as quality assurance for radiosurgery. It is the intention of this study to form the basis for a future randomized controlled trial comparing conventional radiotherapy with fractionated radiosurgery for palliation of painful vertebral metastases. Trial registration ClinicalTrials.gov Identifier: NCT01594892}, subject = {Medizin}, language = {en} } @article{GuckenbergerAlexandrowFlentje2012, author = {Guckenberger, Matthias and Alexandrow, Nikolaus and Flentje, Michael}, title = {Radiotherapy alone for stage I-III low grade follicular lymphoma: long-term outcome and comparison of extended field and total nodal irradiation}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-75702}, year = {2012}, abstract = {Background: To analyze long-term results of radiotherapy alone for stage I-III low grade follicular lymphoma and to compare outcome after extended field irradiation (EFI) and total nodal irradiation (TNI). Methods and materials: Between 1982 and 2007, 107 patients were treated with radiotherapy alone for low grade follicular lymphoma at Ann Arbor stage I (n = 50), II (n = 36) and III (n = 21); 48 and 59 patients were treated with EFI and TNI, respectively. The median total dose in the first treatment series of the diaphragmatic side with larger lymphoma burden was 38 Gy (25 Gy - 50 Gy) and after an interval of median 30 days, a total dose of 28 Gy (12.6 Gy - 45 Gy) was given in the second treatment series completing TNI. Results: After a median follow-up of 14 years for living patients, 10-years and 15-years overall survival (OS) were 64\% and 50\%, respectively. Survival was not significantly different between stages I, II and III. TNI and EFI resulted in 15-years OS of 65\% and 34\% but patients treated with TNI were younger, had better performance status and higher stage of disease compared to patients treated with EFI. In multivariate analysis, only age at diagnosis (p<0.001, relative risk [RR] 1.06) and Karnofsky performance status (p = 0.04, RR = 0.96) were significantly correlated with OS. Freedom from progression (FFP) was 58\% and 56\% after 10-years and 15-years, respectively. Recurrences outside the irradiated volume were significantly reduced after TNI compared to EFI; however, increased rates of in-field recurrences and extra-nodal out-of-field recurrence counterbalanced this effect resulting in no significant difference in FFP between TNI and EFI. In univariate analysis, FFP was significantly improved in stage I compared to stage II but no differences were observed between stages I/II and stage III. In multivariate analysis no patient or treatment parameter was correlated with FFP. Acute toxicity was significantly increased after TNI compared to EFI with a trend to increased late toxicity as well. Conclusions: Radiotherapy alone for stage I and II follicular lymphoma resulted in long-term OS with high rates of disease control; no benefit of TNI over EFI was observed. For stage III follicular lymphoma, TNI achieved promising OS and FFP and should be considered as a potentially curative treatment option.}, subject = {Medizin}, language = {en} } @article{SweeneySeubertStarketal.2012, author = {Sweeney, Reinhart A. and Seubert, Benedikt and Stark, Silke and Homann, Vanessa and M{\"u}ller, Gerd and Flentje, Michael and Guckenbeger, Matthias}, title = {Accuracy and inter-observer variability of 3D versus 4D cone-beam CT based image-guidance in SBRT for lung tumors}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-75698}, year = {2012}, abstract = {Background: To analyze the accuracy and inter-observer variability of image-guidance (IG) using 3D or 4D cone-beam CT (CBCT) technology in stereotactic body radiotherapy (SBRT) for lung tumors. Materials and methods: Twenty-one consecutive patients treated with image-guided SBRT for primary and secondary lung tumors were basis for this study. A respiration correlated 4D-CT and planning contours served as reference for all IG techniques. Three IG techniques were performed independently by three radiation oncologists (ROs) and three radiotherapy technicians (RTTs). Image-guidance using respiration correlated 4D-CBCT (IG-4D) with automatic registration of the planning 4D-CT and the verification 4D-CBCT was considered gold-standard. Results were compared with two IG techniques using 3D-CBCT: 1) manual registration of the planning internal target volume (ITV) contour and the motion blurred tumor in the 3D-CBCT (IG-ITV); 2) automatic registration of the planning reference CT image and the verification 3D-CBCT (IG-3D). Image quality of 3D-CBCT and 4D-CBCT images was scored on a scale of 1-3, with 1 being best and 3 being worst quality for visual verification of the IGRT results. Results: Image quality was scored significantly worse for 3D-CBCT compared to 4D-CBCT: the worst score of 3 was given in 19 \% and 7.1 \% observations, respectively. Significant differences in target localization were observed between 4D-CBCT and 3D-CBCT based IG: compared to the reference of IG-4D, tumor positions differed by 1.9 mm± 0.9 mm (3D vector) on average using IG-ITV and by 3.6 mm± 3.2 mm using IG-3D; results of IG-ITV were significantly closer to the reference IG-4D compared to IG-3D. Differences between the 4D-CBCT and 3D-CBCT techniques increased significantly with larger motion amplitude of the tumor; analogously, differences increased with worse 3D-CBCT image quality scores. Inter-observer variability was largest in SI direction and was significantly larger in IG using 3D-CBCT compared to 4D-CBCT: 0.6 mm versus 1.5 mm (one standard deviation). Inter-observer variability was not different between the three ROs compared to the three RTTs. Conclusions: Respiration correlated 4D-CBCT improves the accuracy of image-guidance by more precise target localization in the presence of breathing induced target motion and by reduced inter-observer variability.}, subject = {Medizin}, language = {en} } @article{GuckenbergerRoeschBaieretal.2012, author = {Guckenberger, Matthias and Roesch, Johannes and Baier, Kurt and Sweeney, Reinhart A. and Flentje, Michael}, title = {Dosimetric consequences of translational and rotational errors in frame-less image-guided radiosurgery}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-75669}, year = {2012}, abstract = {Background: To investigate geometric and dosimetric accuracy of frame-less image-guided radiosurgery (IG-RS) for brain metastases. Methods and materials: Single fraction IG-RS was practiced in 72 patients with 98 brain metastases. Patient positioning and immobilization used either double- (n = 71) or single-layer (n = 27) thermoplastic masks. Pre-treatment set-up errors (n = 98) were evaluated with cone-beam CT (CBCT) based image-guidance (IG) and were corrected in six degrees of freedom without an action level. CBCT imaging after treatment measured intra-fractional errors (n = 64). Pre- and posttreatment errors were simulated in the treatment planning system and target coverage and dose conformity were evaluated. Three scenarios of 0 mm, 1 mm and 2 mm GTV-to-PTV (gross tumor volume, planning target volume) safety margins (SM) were simulated. Results: Errors prior to IG were 3.9 mm± 1.7 mm (3D vector) and the maximum rotational error was 1.7° ± 0.8° on average. The post-treatment 3D error was 0.9 mm± 0.6 mm. No differences between double- and single-layer masks were observed. Intra-fractional errors were significantly correlated with the total treatment time with 0.7mm±0.5mm and 1.2mm±0.7mm for treatment times ≤23 minutes and >23 minutes (p<0.01), respectively. Simulation of RS without image-guidance reduced target coverage and conformity to 75\% ± 19\% and 60\% ± 25\% of planned values. Each 3D set-up error of 1 mm decreased target coverage and dose conformity by 6\% and 10\% on average, respectively, with a large inter-patient variability. Pre-treatment correction of translations only but not rotations did not affect target coverage and conformity. Post-treatment errors reduced target coverage by >5\% in 14\% of the patients. A 1 mm safety margin fully compensated intra-fractional patient motion. Conclusions: IG-RS with online correction of translational errors achieves high geometric and dosimetric accuracy. Intra-fractional errors decrease target coverage and conformity unless compensated with appropriate safety margins.}, subject = {Medizin}, language = {en} } @article{KreisslHaenscheidLoehretal.2012, author = {Kreissl, Michael C. and H{\"a}nscheid, Heribert and L{\"o}hr, Mario and Verburg, Frederik A. and Schiller, Markus and Lassmann, Michael and Reiners, Christoph and Samnick, Samuel S. and Buck, Andreas K. and Flentje, Michael and Sweeney, Reinhart A.}, title = {Combination of peptide receptor radionuclide therapy with fractionated external beam radiotherapy for treatment of advanced symptomatic meningioma}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-75540}, year = {2012}, abstract = {Background: External beam radiotherapy (EBRT) is the treatment of choice for irresectable meningioma. Due to the strong expression of somatostatin receptors, peptide receptor radionuclide therapy (PRRT) has been used in advanced cases. We assessed the feasibility and tolerability of a combination of both treatment modalities in advanced symptomatic meningioma. Methods: 10 patients with irresectable meningioma were treated with PRRT (177Lu-DOTA0,Tyr3 octreotate or - DOTA0,Tyr3 octreotide) followed by external beam radiotherapy (EBRT). EBRT performed after PRRT was continued over 5-6 weeks in IMRT technique (median dose: 53.0 Gy). All patients were assessed morphologically and by positron emission tomography (PET) before therapy and were restaged after 3-6 months. Side effects were evaluated according to CTCAE 4.0. Results: Median tumor dose achieved by PRRT was 7.2 Gy. During PRRT and EBRT, no side effects>CTCAE grade 2 were noted. All patients reported stabilization or improvement of tumor-associated symptoms, no morphologic tumor progression was observed in MR-imaging (median follow-up: 13.4 months). The median pre-therapeutic SUVmax in the meningiomas was 14.2 (range: 4.3-68.7). All patients with a second PET after combined PRRT + EBRT showed an increase in SUVmax (median: 37\%; range: 15\%-46\%) to a median value of 23.7 (range: 8.0-119.0; 7 patients) while PET-estimated volume generally decreased to 81 ± 21\% of the initial volume. Conclusions: The combination of PRRT and EBRT is feasible and well tolerated. This approach represents an attractive strategy for the treatment of recurring or progressive symptomatic meningioma, which should be further evaluated.}, subject = {Medizin}, language = {en} } @article{WilbertGuckenbergerPolatetal.2010, author = {Wilbert, Juergen and Guckenberger, Matthias and Polat, Buelent and Sauer, Otto and Vogele, Michael and Flentje, Michael and Sweeney, Reinhart A.}, title = {Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical results}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-68613}, year = {2010}, abstract = {Background: To introduce a novel method of patient positioning for high precision intracranial radiotherapy. Methods: An infrared(IR)-array, reproducibly attached to the patient via a vacuum-mouthpiece(vMP) and connected to the table via a 6 degree-of-freedom(DoF) mechanical arm serves as positioning and fixation system. After IR-based manual prepositioning to rough treatment position and fixation of the mechanical arm, a cone-beam CT(CBCT) is performed. A robotic 6 DoF treatment couch (HexaPOD™) then automatically corrects all remaining translations and rotations. This absolute position of infrared markers at the first fraction acts as reference for the following fractions where patients are manually prepositioned to within ± 2 mm and ± 2° of this IR reference position prior to final HexaPOD-based correction; consequently CBCT imaging is only required once at the first treatment fraction. The preclinical feasibility and attainable repositioning accuracy of this method was evaluated on a phantom and human volunteers as was the clinical efficacy on 7 pilot study patients. Results: Phantom and volunteer manual IR-based prepositioning to within ± 2 mm and ± 2° in 6DoF was possible within a mean(± SD) of 90 ± 31 and 56 ± 22 seconds respectively. Mean phantom translational and rotational precision after 6 DoF corrections by the HexaPOD was 0.2 ± 0.2 mm and 0.7 ± 0.8° respectively. For the actual patient collective, the mean 3D vector for inter-treatment repositioning accuracy (n = 102) was 1.6 ± 0.8 mm while intra-fraction movement (n = 110) was 0.6 ± 0.4 mm. Conclusions: This novel semi-automatic 6DoF IR-based system has been shown to compare favourably with existing non-invasive intracranial repeat fixation systems with respect to handling, reproducibility and, more importantly, intrafraction rigidity. Some advantages are full cranial positioning flexibility for single and fractionated IGRT treatments and possibly increased patient comfort.}, subject = {Strahlentherapie}, language = {en} }