@article{JakubietzJakubietzHorchetal.2019, author = {Jakubietz, Rafael G. and Jakubietz, Danni F. and Horch, Raymund E. and Gruenert, Joerg G. and Meffert, Rainer H. and Jakubietz, Michael G.}, title = {The microvascular peroneal artery perforator flap as a "lifeboat" for pedicled flaps}, series = {Plastic and Reconstructive Surgery - Global Open}, volume = {7}, journal = {Plastic and Reconstructive Surgery - Global Open}, number = {9}, doi = {10.1097/GOX.0000000000002396}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-202233}, pages = {e2396}, year = {2019}, abstract = {Background: Pedicled perforator flaps have expanded reconstructive options in extremity reconstruction. Despite preoperative mapping, intraoperative findings may require microvascular tissue transfer when no adequate perforators can be found. The free peroneal artery perforator flap may serve as a reliable back-up plan in small defects. Methods: In 16 patients with small soft tissue defects on the upper and lower extremities, perforator-based propeller flaps were planned. The handheld Doppler device was used to localize potential perforators for a propeller flap in close proximity to the defect. Perforators of the proximal peroneal artery were also marked to allow conversion to microvascular tissue transfer. Results: In 6 cases, no adequate perforators were found intraoperatively. In 4 patients, the peroneal artery perforator flap was harvested and transferred. The pedicle length did not exceed 4 cm. No flap loss occurred. Conclusions: When no adequate perforator capable of nourishing a propeller flap can be found intraoperatively, the free peroneal artery flap is a good option to reconstruct small soft tissue defects in the distal extremities. The short vascular pedicle is less ideal in cases with a large zone of injury requiring a more distant site of anastomosis or when recipient vessels are located in deeper tissue planes.}, language = {en} } @article{JakubietzMeffertSchmidtetal.2017, author = {Jakubietz, Michael G. and Meffert, Rainer H. and Schmidt, Karsten and Gruenert, Joerg G. and Jakubietz, Rafael G.}, title = {Acute A4 Pulley Reconstruction with a First Extensor Compartment Onlay Graft}, series = {Plastic and Reconstructive Surgery Global Open}, volume = {5}, journal = {Plastic and Reconstructive Surgery Global Open}, number = {6}, doi = {10.1097/GOX.0000000000001361}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-158057}, pages = {e1361}, year = {2017}, abstract = {Background: The integrity of the flexor tendon pulley apparatus is crucial for unimpaired function of the digits. Although secondary reconstruction is an established procedure in multi-pulley injuries, acute reconstruction of isolated, closed pulley ruptures is a rare occurrence. There are 3 factors influencing the functional outcome of a reconstruction: gapping distance between tendon and bone (E-space), bulkiness of the reconstruction, and stability. As direct repair is rarely done, grafts are used to reinforce the pulley. An advantage of the first extensor retinaculum graft is the synovial coating providing the possibility to be used both as a direct graft with synovial coating or as an onlay graft after removal of the synovia when the native synovial layer is present. Methods: A graft from the first dorsal extensor compartment is used as an onlay graft to reinforce the sutured A4 pulley. This technique allows reconstruction of the original dimensions of the pulley system while stability is ensured by anchoring the onlay graft to the bony insertions of the pulley. Results: Anatomical reconstruction can be achieved with this method. The measured E-space remained 0 mm throughout the recovery, while the graft incorporated as a slim reinforcement of the pulley, displaying no bulkiness. Conclusions: The ideal reconstruction should provide synovial coating and sufficient strength with minimal bulk. Early reconstruction using an onlay graft offers these options. The native synovial lining is preserved and the graft is used to reinforce the pulley.}, language = {en} } @article{JakubietzGruenertJakubietz2012, author = {Jakubietz, Michael G. and Gruenert, Joerg G. and Jakubietz, Rafael G.}, title = {Palmar and dorsal fixed-angle plates in AO C-type fractures of the distal radius: is there an advantage of palmar plates in the long term?}, series = {Journal of Orthopedic Surgery and Research}, volume = {7}, journal = {Journal of Orthopedic Surgery and Research}, number = {8}, doi = {10.1186/1749-799X-7-8}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-133987}, year = {2012}, abstract = {Background: Current surgical approaches to the distal radius include dorsal and palmar plate fixation. While palmar plates have gained widespread popularity, few reports have provided data on long term clinical outcomes in comparison. This paper reports the result of a randomised clinical study comparing dorsal Pi plates and palmar, angle-stable plates for treatment of comminuted, intraarticular fractures of the distal radius over the course of twelve months. Methods: 42 patients with unilateral, intraarticular fractures of the distal radius were included and randomised to 2 groups, 22 were treated with a palmar plate, 20 received a dorsal Pi-plate. Results were evaluated after 6 weeks, 3, 6 and 12 months postoperatively focussing on functional recovery as well as radiological results. Results: The palmar plate group demonstrated significantly better results regarding range of motion and grip strength over the course of 12 months. While a comparable increase in function was observed in both groups, the better results from the early postoperative period in the palmar plate group prevailed over the whole course. Radiological results showed a significantly increased palmar tilt and carpal sag in dorsal plates, with other radiological parameters being comparable. Pain levels were decreased in dorsal plates after hardware removal and failed to show significant differences after 12 months. However, complications such as tendon ruptures were more frequent in the dorsal plate group. Conclusions: Functional advantage of palmar plates gained within the first 6 weeks prevails over the course of a year. Both groups demonstrate further gradual increase of function after 6 months, although dorsal plates did not catch up completely. Improved early postoperative function seems to be the cornerstone for the best possible results. Patients with dorsal plates benefit from hardware removal more than palmar plates in terms of reduction of pain levels. The advantage of palmar plates is a faster functional recovery with lower complication rates. This is especially important in the elderly population. Radiological results did not show a superiority of palmar plates over dorsal plates.}, language = {en} } @article{JakubietzGruenertJakubietz2011, author = {Jakubietz, Michael G. and Gruenert, Joerg G. and Jakubietz, Rafael G.}, title = {The use of beta-tricalcium phosphate bone graft substitute in dorsally plated, comminuted distal radius fractures}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-68829}, year = {2011}, abstract = {Background: Intraarticular distal radius fractures can be treated with many methods. While internal fixation with angle stable implants has become increasingly popular, the use of bone graft substitutes has also been recommended to address comminution zones and thus increase stability. Whether a combination of both methods will improve clinical outcomes was the purpose of the study Methods: The study was thus conducted as a prospective randomized clinical trial. 39 patients with unilateral, intraarticular fractures of the distal radius were included and randomized to 2 groups, one being treated with internal fixation only, while the second group received an additional bone graft substitute. Results: There was no statistical significance between both groups in functional and radiological results. The occurrence of complications did also not show statistical significance. Conclusions: No advantage of additional granular bone graft substitutes could be seen in this study. Granular bone graft substitutes do not seem to provide extra stability if dorsal angle stable implants are used. Dorsal plates have considerable complication rates such as extensor tendon ruptures and development of CRPS.}, subject = {Medizin}, language = {en} }