@article{DongBoeppleThieletal.2023, author = {Dong, Meng and B{\"o}pple, Kathrin and Thiel, Julia and Winkler, Bernd and Liang, Chunguang and Schueler, Julia and Davies, Emma J. and Barry, Simon T. and Metsalu, Tauno and M{\"u}rdter, Thomas E. and Sauer, Georg and Ott, German and Schwab, Matthias and Aulitzky, Walter E.}, title = {Perfusion air culture of precision-cut tumor slices: an ex vivo system to evaluate individual drug response under controlled culture conditions}, series = {Cells}, volume = {12}, journal = {Cells}, number = {5}, issn = {2073-4409}, doi = {10.3390/cells12050807}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-311030}, year = {2023}, abstract = {Precision-cut tumor slices (PCTS) maintain tissue heterogeneity concerning different cell types and preserve the tumor microenvironment (TME). Typically, PCTS are cultured statically on a filter support at an air-liquid interface, which gives rise to intra-slice gradients during culture. To overcome this problem, we developed a perfusion air culture (PAC) system that can provide a continuous and controlled oxygen medium, and drug supply. This makes it an adaptable ex vivo system for evaluating drug responses in a tissue-specific microenvironment. PCTS from mouse xenografts (MCF-7, H1437) and primary human ovarian tumors (primary OV) cultured in the PAC system maintained the morphology, proliferation, and TME for more than 7 days, and no intra-slice gradients were observed. Cultured PCTS were analyzed for DNA damage, apoptosis, and transcriptional biomarkers for the cellular stress response. For the primary OV slices, cisplatin treatment induced a diverse increase in the cleavage of caspase-3 and PD-L1 expression, indicating a heterogeneous response to drug treatment between patients. Immune cells were preserved throughout the culturing period, indicating that immune therapy can be analyzed. The novel PAC system is suitable for assessing individual drug responses and can thus be used as a preclinical model to predict in vivo therapy responses.}, language = {en} } @article{HelmerHelfSammethetal.2022, author = {Helmer, Philipp and Helf, Daniel and Sammeth, Michael and Winkler, Bernd and Hottenrott, Sebastian and Meybohm, Patrick and Kranke, Peter}, title = {The use of non-invasive continuous blood pressure measuring (ClearSight\(^®\)) during central neuraxial anaesthesia for caesarean section — a retrospective validation study}, series = {Journal of Clinical Medicine}, volume = {11}, journal = {Journal of Clinical Medicine}, number = {15}, issn = {2077-0383}, doi = {10.3390/jcm11154498}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-286042}, year = {2022}, abstract = {Background: The close monitoring of blood pressure during a caesarean section performed under central neuraxial anaesthesia should be the standard of safe anaesthesia. As classical oscillometric and invasive blood pressure measuring have intrinsic disadvantages, we investigated a novel, non-invasive technique for continuous blood pressure measuring. Methods: In this monocentric, retrospective data analysis, the reliability of continuous non-invasive blood pressure measuring using ClearSight\(^®\) (Edwards Lifesciences Corporation) is validated in 31 women undergoing central neuraxial anaesthesia for caesarean section. In addition, patients and professionals evaluated ClearSight\(^®\) through questioning. Results: 139 measurements from 11 patients were included in the final analysis. Employing Bland-Altman analyses, we identified a bias of -10.8 mmHg for systolic, of -0.45 mmHg for diastolic and of +0.68 mmHg for mean arterial blood pressure measurements. Pooling all paired measurements resulted in a Pearson correlation coefficient of 0.7 for systolic, of 0.67 for diastolic and of 0.75 for mean arterial blood pressure. Compensating the interindividual differences in linear regressions of the paired measurements provided improved correlation coefficients of 0.73 for systolic, of 0.9 for diastolic and of 0.89 for mean arterial blood pressure measurements. Discussion: Diastolic and mean arterial blood pressure are within an acceptable range of deviation from the reference method, according to the Association for the Advancement of Medical Instrumentation (AAMI) in the patient collective under study. Both patients and professionals prefer ClearSight\(^®\) to oscillometric blood pressure measurement in regard of comfort and handling.}, language = {en} }