@article{SimsekyilmazLiehnWeinandyetal.2016, author = {Simsekyilmaz, Sakine and Liehn, Elisa A. and Weinandy, Stefan and Schreiber, Fabian and Megens, Remco T. A. and Theelen, Wendy and Smeets, Ralf and Jockenh{\"o}vel, Stefan and Gries, Thomas and M{\"o}ller, Martin and Klee, Doris and Weber, Christian and Zernecke, Alma}, title = {Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice}, series = {PLoS ONE}, volume = {11}, journal = {PLoS ONE}, number = {5}, doi = {10.1371/journal.pone.0155829}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-179745}, year = {2016}, abstract = {Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG), and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after implantation into carotid arteries of mice. Nitinol foils or stents (bare metal) were coated with star-PEG, and bio-functionalized with RGD, or RGD/CXCL1. Cell adhesion to star-PEG-coated nitinol foils was unaltered or reduced, whereas bio-functionalization with RGD but foremost RGD/CXCL1 increased adhesion of early angiogenic outgrowth cells (EOCs) and endothelial cells but not smooth muscle cells when compared with bare metal foils. Stimulation of cells with RGD/CXCL1 furthermore increased the proliferation of EOCs. In vivo, bio-functionalization with RGD/CXCL1 significantly reduced neointima formation and thrombus formation, and increased re-endothelialization in apoE\(^{-/-}\) carotid arteries compared with bare-metal nitinol stents, star-PEG-coated stents, and stents bio-functionalized with RGD only. Bio-functionalization of star-PEG-coated nitinol-stents with RGD/CXCL1 reduced in-stent neointima formation. By supporting the adhesion and proliferation of endothelial progenitor cells, RGD/CXCL1 coating of stents may help to accelerate endothelial repair after stent implantation, and thus may harbor the potential to limit the complication of in-stent restenosis in clinical approaches.}, language = {en} } @article{KastenNaserBruellhoffetal.2014, author = {Kasten, Annika and Naser, Tamara and Br{\"u}llhoff, Kristina and Fiedler, J{\"o}rg and M{\"u}ller, Petra and M{\"o}ller, Martin and Rychly, Joachim and Groll, J{\"u}rgen and Brenner, Rolf E.}, title = {Guidance of Mesenchymal Stem Cells on Fibronectin Structured Hydrogel Films}, series = {PLOS ONE}, volume = {9}, journal = {PLOS ONE}, number = {10}, doi = {10.1371/journal.pone.0109411}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-114897}, pages = {e109411}, year = {2014}, abstract = {Designing of implant surfaces using a suitable ligand for cell adhesion to stimulate specific biological responses of stem cells will boost the application of regenerative implants. For example, materials that facilitate rapid and guided migration of stem cells would promote tissue regeneration. When seeded on fibronectin (FN) that was homogeneously immmobilized to NCO-sP(EO-stat-PO), which otherwise prevents protein binding and cell adhesion, human mesenchymal stem cells (MSC) revealed a faster migration, increased spreading and a more rapid organization of different cellular components for cell adhesion on fibronectin than on a glass surface. To further explore, how a structural organization of FN controls the behavior of MSC, adhesive lines of FN with varying width between 10 mu m and 80 mu m and spacings between 5 mu m and 20 mu m that did not allow cell adhesion were generated. In dependance on both line width and gaps, cells formed adjacent cell contacts, were individually organized in lines, or bridged the lines. With decreasing sizes of FN lines, speed and directionality of cell migration increased, which correlated with organization of the actin cytoskeleton, size and shape of the nuclei as well as of focal adhesions. Together, defined FN lines and gaps enabled a fine tuning of the structural organization of cellular components and migration. Microstructured adhesive substrates can mimic the extracellular matrix in vivo and stimulate cellular mechanisms which play a role in tissue regeneration.}, language = {en} }