@article{KremerPauwelsPozzietal.2021, author = {Kremer, Naomi I. and Pauwels, Rik W. J. and Pozzi, Nicol{\`o} G. and Lange, Florian and Roothans, Jonas and Volkmann, Jens and Reich, Martin M.}, title = {Deep Brain Stimulation for Tremor: Update on Long-Term Outcomes, Target Considerations and Future Directions}, series = {Journal of Clinical Medicine}, volume = {10}, journal = {Journal of Clinical Medicine}, number = {16}, issn = {2077-0383}, doi = {10.3390/jcm10163468}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-244982}, year = {2021}, abstract = {Deep brain stimulation (DBS) of the thalamic ventral intermediate nucleus is one of the main advanced neurosurgical treatments for drug-resistant tremor. However, not every patient may be eligible for this procedure. Nowadays, various other functional neurosurgical procedures are available. In particular cases, radiofrequency thalamotomy, focused ultrasound and radiosurgery are proven alternatives to DBS. Besides, other DBS targets, such as the posterior subthalamic area (PSA) or the dentato-rubro-thalamic tract (DRT), may be appraised as well. In this review, the clinical characteristics and pathophysiology of tremor syndromes, as well as long-term outcomes of DBS in different targets, will be summarized. The effectiveness and safety of lesioning procedures will be discussed, and an evidence-based clinical treatment approach for patients with drug-resistant tremor will be presented. Lastly, the future directions in the treatment of severe tremor syndromes will be elaborated.}, language = {en} } @article{GabrielJirůHillmannKraftetal.2020, author = {Gabriel, Katharina M. A. and J{\´i}rů-Hillmann, Steffi and Kraft, Peter and Selig, Udo and R{\"u}cker, Victoria and M{\"u}hler, Johannes and D{\"o}tter, Klaus and Keidel, Matthias and Soda, Hassan and Rascher, Alexandra and Schneider, Rolf and Pfau, Mathias and Hoffmann, Roy and Stenzel, Joachim and Benghebrid, Mohamed and Goebel, Tobias and Doerck, Sebastian and Kramer, Daniela and Haeusler, Karl Georg and Volkmann, Jens and Heuschmann, Peter U. and Fluri, Felix}, title = {Two years' experience of implementing a comprehensive telemedical stroke network comprising in mainly rural region: the Transregional Network for Stroke Intervention with Telemedicine (TRANSIT-Stroke)}, series = {BMC Neurology}, volume = {20}, journal = {BMC Neurology}, doi = {10.1186/s12883-020-01676-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-229214}, year = {2020}, abstract = {Background Telemedicine improves the quality of acute stroke care in rural regions with limited access to specialized stroke care. We report the first 2 years' experience of implementing a comprehensive telemedical stroke network comprising all levels of stroke care in a defined region. Methods The TRANSIT-Stroke network covers a mainly rural region in north-western Bavaria (Germany). All hospitals providing acute stroke care in this region participate in TRANSIT-Stroke, including four hospitals with a supra-regional certified stroke unit (SU) care (level III), three of those providing teleconsultation to two hospitals with a regional certified SU (level II) and five hospitals without specialized SU care (level I). For a two-year-period (01/2015 to 12/2016), data of eight of these hospitals were available; 13 evidence-based quality indicators (QIs) related to processes during hospitalisation were evaluated quarterly and compared according to predefined target values between level-I- and level-II/III-hospitals. Results Overall, 7881 patients were included (mean age 74.6 years +/- 12.8; 48.4\% female). In level-II/III-hospitals adherence of all QIs to predefined targets was high ab initio. In level-I-hospitals, three patterns of QI-development were observed: a) high adherence ab initio (31\%), mainly in secondary stroke prevention; b) improvement over time (44\%), predominantly related to stroke specific diagnosis and in-hospital organization; c) no clear time trends (25\%). Overall, 10 out of 13 QIs reached predefined target values of quality of care at the end of the observation period. Conclusion The implementation of the comprehensive TRANSIT-Stroke network resulted in an improvement of quality of care in level-I-hospitals.}, language = {en} } @article{HillmannWiedmannFraseretal.2015, author = {Hillmann, Steffi and Wiedmann, Silke and Fraser, Alec and Baeza, Juan and Rudd, Anthony and Norrving, Bo and Asplund, Kjell and Niewada, Maciej and Dennis, Martin and Hermanek, Peter and Wolfe, Charles D. A. and Heuschmann, Peter U.}, title = {Temporal changes in the quality of acute stroke care in five national audits across Europe}, series = {BioMed Research International}, volume = {2015}, journal = {BioMed Research International}, number = {432497}, doi = {10.1155/2015/432497}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-149059}, year = {2015}, abstract = {Background. Data on potential variations in delivery of appropriate stroke care over time are scarce. We investigated temporal changes in the quality of acute hospital stroke care across five national audits in Europe over a period of six years. Methods. Data were derived from national stroke audits in Germany, Poland, Scotland, Sweden, and England/Wales/Northern Ireland participating within the European Implementation Score (EIS) collaboration. Temporal changes in predefined quality indicators with comparable information between the audits were investigated. Multivariable logistic regression analyses were performed to estimate adherence to quality indicators over time. Results. Between 2004 and 2009, individual data from 542,112 patients treated in 538 centers participating continuously over the study period were included. In most audits, the proportions of patients who were treated on a SU, were screened for dysphagia, and received thrombolytic treatment increased over time and ranged from 2-fold to almost 4-fold increase in patients receiving thrombolytic therapy in 2009 compared to 2004. Conclusions. A general trend towards a better quality of stroke care defined by standardized quality indicators was observed over time. The association between introducing a specific measure and higher adherence over time might indicate that monitoring of stroke care performance contributes to improving quality of care.}, language = {en} } @article{SherifHeroldVoelkeretal.2015, author = {Sherif, Mohammad A. and Herold, Joerg and Voelker, Wolfram and Maniuc, Octavian and Ertl, Georg and Praast, Christian and Braun-Dullaeus, Ruediger Christian}, title = {Feasibility of a new method using two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation; a case-control study}, series = {BMC Cardiovascular Disorders}, volume = {15}, journal = {BMC Cardiovascular Disorders}, number = {78}, doi = {10.1186/s12872-015-0072-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-148328}, year = {2015}, abstract = {Background: Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we validated a new method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus prior to TAVI. Methods: We analysed 124 patients who underwent successful TAVI using a self-expandable prosthesis, divided equally into two groups; in the study group we used the cross sectional short axis 2D-TEE for measurement of the aortic annulus and in the control group we used the long axis 2D-TEE. Results: Both groups were comparable regarding the clinical parameters. On the other hand, patients in the study group had less left ventricular ejection fraction (38.9 \% versus 45.6 \%, p = 0.01). The aortic valve annulus was, although not statistically significant, smaller in the study group (21.58 versus 23.28 mm, p = 0.25). Post procedural quantification of the aortic regurgitation revealed that only one patient in both groups had severe aortic regurgitation (AR), in this patient the valve was implanted deep. The incidence of significant AR was higher in the control group (29.0 \% versus 12.9 \%, p = 0.027). Conclusions: Sizing of the aortic valve annulus using cross-sectional 2D-TEE offers a safe and plausible method for patients undergoing TAVI using the self-expandable prosthesis and is significantly superior to using long axis 2D-TEE.}, language = {en} } @article{SherifInceManiucetal.2015, author = {Sherif, Mohammad A. and Ince, H{\"u}seyin and Maniuc, Octavian and Reiter, Therese and Voelker, Wolfram and Ertl, Georg and {\"O}ner, Alper}, title = {Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation}, series = {BMC Cardiovascular Disorders}, volume = {15}, journal = {BMC Cardiovascular Disorders}, number = {181}, doi = {10.1186/s12872-015-0181-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-136002}, year = {2015}, abstract = {Background: Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we examined the accuracy of a novel method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus. Methods: We evaluated the theoretical impact of the measurement of the annulus diameter and area using the circumcircle of a triangle method on the decision to perform the procedure and choice of the prosthesis size. Results: Sixty-three consecutive patients were scheduled for TAVI. Mean age was 82 +/- 4 years, and 25 patients (55.6 \%) were female. Mean aortic annulus diameter was 20.3 +/- 2.2 mm assessed by TEE on the mid-esophageal long-axis view and 23.9 +/- 2.3 mm using CT (p < 0.001). There was a tendency for the TEE derived areas using the new method to be higher (p < 0.001). The TEE measurements were on average 42.33 mm(2) higher than the CT measurements without an evidence of a systematic over-or under-sizing (p = 1.00). Agreement between TEE and CT chosen valve sizes was good overall (kappa = 0.67 and weighted kappa = 0.71). For patients who turned out to have no AR, the two methods agreed in 84.6 \% of patients. Conclusions: CT remanis the gold standard in sizing of the aortic valve annulus. Nevertheless, sizing of the aortic valve annulus using TEE derived area may be helpful. The impact of integration of this method in the algorithm of aortic annulus sizing on the outcome of patients undergoing TAVI should be examined in future studies.}, language = {en} } @article{EiseleBlozikStoerketal.2013, author = {Eisele, Marion and Blozik, Eva and St{\"o}rk, Stefan and Tr{\"a}der, Jens-Martin and Herrmann-Lingen, Christoph and Scherer, Martin}, title = {Recognition of depression and anxiety and their association with quality of life, hospitalization and mortality in primary care patients with heart failure - study protocol of a longitudinal observation study}, series = {BMC Family Practice}, volume = {14}, journal = {BMC Family Practice}, number = {180}, issn = {1471-2296}, doi = {10.1186/1471-2296-14-180}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-121881}, year = {2013}, abstract = {Background: International disease management guidelines recommend the regular assessment of depression and anxiety in heart failure patients. Currently there is little data on the effect of screening for depression and anxiety on the quality of life and the prognosis of heart failure (HF). We will investigate the association between the recognition of current depression/anxiety by the general practitioner (GP) and the quality of life and the patients' prognosis. Methods/Design: In this multicenter, prospective, observational study 3,950 patients with HF are recruited by general practices in Germany. The patients fill out questionnaires at baseline and 12-month follow-up. At baseline the GPs are interviewed regarding the somatic and psychological comorbidities of their patients. During the follow-up assessment, data on hospitalization and mortality are provided by the general practice. Based on baseline data, the patients are allocated into three observation groups: HF patients with depression and/or anxiety recognized by their GP (P+/+), those with depression and/or anxiety not recognized (P+/-) and patients without depression and/or anxiety (P-/-). We will perform multivariate regression models to investigate the influence of the recognition of depression and/or anxiety on quality of life at 12 month follow-up, as well as its influences on the prognosis (hospital admission, mortality). Discussion: We will display the frequency of GP-acknowledged depression and anxiety and the frequency of installed therapeutic strategies. We will also describe the frequency of depression and anxiety missed by the GP and the resulting treatment gap. Effects of correctly acknowledged and missed depression/anxiety on outcome, also in comparison to the outcome of subjects without depression/anxiety will be addressed. In case results suggest a treatment gap of depression/anxiety in patients with HF, the results of this study will provide methodological advice for the efficient planning of further interventional research.}, language = {en} }