@article{BeningHamoudaOezkuretal.2017, author = {Bening, Constanze and Hamouda, Khaled and Oezkur, Mehmet and Schimmer, Christoph and Schade, Ina and Gorski, Armin and Aleksic, Ivan and Leyh, Rainer}, title = {Rapid deployment valve system shortens operative times for aortic valve replacement through right anterior minithoracotomy}, series = {Journal of Cardiothoracic Surgery}, volume = {12}, journal = {Journal of Cardiothoracic Surgery}, number = {27}, doi = {10.1186/s13019-017-0598-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-159439}, year = {2017}, abstract = {Background: There is growing evidence from the literature that right anterior minithoracotomy aortic valve replacement (RAT-AVR) improves clinical outcome. However, increased cross clamp time is the strongest argument for surgeons not performing RAT-AVR. Rapid deployment aortic valve systems have the potential to decrease cross-clamp time and ease this procedure. We assessed clinical outcome of rapid deployment and conventional valves through RAT. Methods: Sixty-eight patients (mean age 76 ± 6 years, 32\% females) underwent RAT-AVR between 9/2013 and 7/2015. According to the valve type implanted the patients were divided into two groups. In 43 patients (R-group; mean age 74.1 ± 6.6 years) a rapid deployment valve system (Edwards Intuity, Edwards Lifesciences Corp; Irvine, Calif) and in 25 patients (C-group; mean age 74.2 ± 6.6 years) a conventional stented biological aortic valve was implanted. Results: Aortic cross-clamp (42.1 ± 12 min vs. 68.3 ± 20.3 min; p < 0.001) and bypass time (80.4 ± 39.3 min vs. 106.6 ± 23.2 min; p = 0.001) were shorter in the rapid deployment group (R-group). We observed no differences in clinical outcome. Postoperative gradients (R-group: max gradient, 14.3 ± 8 mmHg vs. 15.5 ± 5 mmHg (C-group), mean gradient, 9.2 ± 1.7 mmHg (R-group) vs. 9.1 ± 2.3 mmHg (C-group) revealed no differences. However, larger prostheses were implanted in C-group (25 mm; IQR 23-27 mm vs. 23 mm; IQR 21-25; p = 0.009). Conclusions: Our data suggest that the rapid deployment aortic valve system reduced cross clamp and bypass time in patients undergoing RAT-AVR with similar hemodynamics as with larger size stented prosthesis. However, larger studies and long-term follow-up are mandatory to confirm our findings.}, language = {en} } @article{OezkurGorskiPeltzetal.2014, author = {Oezkur, Mehmet and Gorski, Armin and Peltz, Jennifer and Wagner, Martin and Lazariotou, Maria and Schimmer, Christoph and Heuschmann, Peter U. and Leyh, Rainer G.}, title = {Preoperative serum h-FABP concentration is associated with postoperative incidence of acute kidney injury in patients undergoing cardiac surgery}, doi = {10.1186/1471-2261-14-117}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-110480}, year = {2014}, abstract = {Background Fatty acid binding protein (FABP) is an intracellular transport protein associated with myocardial damage size in patients undergoing cardiac surgery. Furthermore, elevated FABP serum concentrations are related to a number of common comorbidities, such as heart failure, chronic kidney disease, diabetes mellitus, and metabolic syndrome, which represent important risk factors for postoperative acute kidney injury (AKI). Data are lacking on the association between preoperative FABP serum level and postoperative incidence of AKI. Methods This prospective cohort study investigated the association between preoperative h-FABP serum concentrations and postoperative incidence of AKI, hospitalization time and length of ICU treatment. Blood samples were collected according to a predefined schedule. The AKI Network definition of AKI was used as primary endpoint. All associations were analysed using descriptive and univariate analyses. Results Between 05/2009 and 09/2009, 70 patients undergoing cardiac surgery were investigated. AKI was observed in 45 patients (64\%). Preoperative median (IQR) h-FABP differed between the AKI group (2.9 [1.7-4.1] ng/ml) and patients without AKI (1.7 [1.1-3.3] ng/ml; p = 0.04), respectively. Patients with AKI were significantly older. No statistically significant differences were found for gender, type of surgery, operation duration, CPB-, or X-Clamp time, preoperative cardiac enzymes, HbA1c, or CRP between the two groups. Preoperative h-FABP was also correlated with the length of ICU stay (rs = 0.32, p = 0.007). Conclusions We found a correlation between preoperative serum h-FABP and the postoperative incidence of AKI. Our results suggest a potential role for h-FABP as a biomarker for AKI in cardiac surgery.}, language = {en} }