@article{WeichWernerBucketal.2021, author = {Weich, Alexander and Werner, Rudolf A. and Buck, Andreas K. and Hartrampf, Philipp E. and Serfling, Sebastian E. and Scheurlen, Michael and Wester, Hans-J{\"u}rgen and Meining, Alexander and Kircher, Stefan and Higuchi, Takahiro and Pomper, Martin G. and Rowe, Steven P. and Lapa, Constantin and Kircher, Malte}, title = {CXCR4-Directed PET/CT in Patients with Newly Diagnosed Neuroendocrine Carcinomas}, series = {Diagnostics}, volume = {11}, journal = {Diagnostics}, number = {4}, issn = {2075-4418}, doi = {10.3390/diagnostics11040605}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-234231}, year = {2021}, abstract = {We aimed to elucidate the diagnostic potential of the C-X-C motif chemokine receptor 4 (CXCR4)-directed positron emission tomography (PET) tracer \(^{68}\)Ga-Pentixafor in patients with poorly differentiated neuroendocrine carcinomas (NEC), relative to the established reference standard \(^{18}\)F-FDG PET/computed tomography (CT). In our database, we retrospectively identified 11 treatment-na{\"i}ve patients with histologically proven NEC, who underwent \(^{18}\)F-FDG and CXCR4-directed PET/CT for staging and therapy planning. The images were analyzed on a per-patient and per-lesion basis and compared to immunohistochemical staining (IHC) of CXCR4 from PET-guided biopsies. \(^{68}\)Ga-Pentixafor visualized tumor lesions in 10/11 subjects, while \(^{18}\)F-FDG revealed sites of disease in all 11 patients. Although weak to moderate CXCR4 expression could be corroborated by IHC in 10/11 cases, \(^{18}\)F-FDG PET/CT detected significantly more tumor lesions (102 vs. 42; total lesions, n = 107; p < 0.001). Semi-quantitative analysis revealed markedly higher 18F-FDG uptake as compared to \(^{68}\)Ga-Pentixafor (maximum and mean standardized uptake values (SUV) and tumor-to-background ratios (TBR) of cancerous lesions, SUVmax: 12.8 ± 9.8 vs. 5.2 ± 3.7; SUVmean: 7.4 ± 5.4 vs. 3.1 ± 3.2, p < 0.001; and, TBR 7.2 ± 7.9 vs. 3.4 ± 3.0, p < 0.001). Non-invasive imaging of CXCR4 expression in NEC is inferior to the reference standard \(^{18}\)F-FDG PET/CT.}, language = {en} } @article{WeichRogollGawlasetal.2021, author = {Weich, Alexander and Rogoll, Dorothee and Gawlas, Sophia and Mayer, Lars and Weich, Wolfgang and Pongracz, Judit and Kudlich, Theodor and Meining, Alexander and Scheurlen, Michael}, title = {Wnt/β-catenin signaling regulates CXCR4 expression and [\(^{68}\)Ga] Pentixafor internalization in neuroendocrine tumor cells}, series = {Diagnostics}, volume = {11}, journal = {Diagnostics}, number = {2}, issn = {2075-4418}, doi = {10.3390/diagnostics11020367}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-228914}, year = {2021}, abstract = {Loss of Somatostatin Receptor 2 (SSTR2) expression and rising CXC Chemokine Receptor Type 4 (CXCR4) expression are associated with dedifferentiation in neuroendocrine tumors (NET). In NET, CXCR4 expression is associated with enhanced metastatic and invasive potential and worse prognosis but might be a theragnostic target. Likewise, activation of Wnt/β-catenin signaling may promote a more aggressive phenotype in NET. We hypothesized an interaction of the Wnt/β-catenin pathway with CXCR4 expression and function in NET. The NET cell lines BON-1, QGP-1, and MS-18 were exposed to Wnt inhibitors (5-aza-CdR, quercetin, and niclosamide) or the Wnt activator LiCl. The expressions of Wnt pathway genes and of CXCR4 were studied by qRT-PCR, Western blot, and immunohistochemistry. The effects of Wnt modulators on uptake of the CXCR4 ligand [\(^{68}\)Ga] Pentixafor were measured. The Wnt activator LiCl induced upregulation of CXCR4 and Wnt target gene expression. Treatment with the Wnt inhibitors had opposite effects. LiCl significantly increased [\(^{68}\)Ga] Pentixafor uptake, while treatment with Wnt inhibitors decreased radiopeptide uptake. Wnt pathway modulation influences CXCR4 expression and function in NET cell lines. Wnt modulation might be a tool to enhance the efficacy of CXCR4-directed therapies in NET or to inhibit CXCR4-dependent proliferative signaling. The underlying mechanisms for the interaction of the Wnt pathway with CXCR4 expression and function have yet to be clarified.}, language = {en} } @article{SudarevicTroyaFuchsetal.2023, author = {Sudarevic, Boban and Troya, Joel and Fuchs, Karl-Hermann and Hann, Alexander and Vereczkei, Andras and Meining, Alexander}, title = {Design and development of a flexible 3D-printed endoscopic grasping instrument}, series = {Applied Sciences}, volume = {13}, journal = {Applied Sciences}, number = {9}, issn = {2076-3417}, doi = {10.3390/app13095656}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-319186}, year = {2023}, abstract = {(1) Background: Interventional endoscopic procedures are growing more popular, requiring innovative instruments and novel techniques. Three-dimensional printing has demonstrated great potential for the rapid development of prototypes that can be used for the early assessment of various concepts. In this work, we present the development of a flexible endoscopic instrument and explore its potential benefits. (2) Methods: The properties of the instrument, such as its maneuverability, flexibility, and bending force, were evaluated in a series of bench tests. Additionally, the effectiveness of the instrument was evaluated in an ex vivo porcine model by medical experts, who graded its properties and performance. Furthermore, the time necessary to complete various interventional endoscopic tasks was recorded. (3) Results: The instrument achieved bending angles of ±216° while achieving a bending force of 7.85 (±0.53) Newtons. The time needed to reach the operating region was 120 s median, while it took 70 s median to insert an object in a cavity. Furthermore, it took 220 s median to insert the instrument and remove an object from the cavity. (4) Conclusions: This study presents the development of a flexible endoscopic instrument using three-dimensional printing technology and its evaluation. The instrument demonstrated high bending angles and forces, and superior properties compared to the current state of the art. Furthermore, it was able to complete various interventional endoscopic tasks in minimal time, thus potentially leading to the improved safety and effectiveness of interventional endoscopic procedures in the future.}, language = {en} } @article{ReimerSeyfriedFlemmingetal.2022, author = {Reimer, Stanislaus and Seyfried, Florian and Flemming, Sven and Brand, Markus and Weich, Alexander and Widder, Anna and Plaßmeier, Lars and Kraus, Peter and D{\"o}ring, Anna and Hering, Ilona and Hankir, Mohammed K. and Meining, Alexander and Germer, Christoph-Thomas and Lock, Johan F. and Groneberg, Kaja}, title = {Evolution of endoscopic vacuum therapy for upper gastrointestinal leakage over a 10-year period: a quality improvement study}, series = {Surgical Endoscopy}, volume = {36}, journal = {Surgical Endoscopy}, number = {12}, doi = {10.1007/s00464-022-09400-w}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-323953}, pages = {9169-9178}, year = {2022}, abstract = {Background Endoscopic vacuum therapy (EVT) is an effective treatment option for leakage of the upper gastrointestinal (UGI) tract. The aim of this study was to evaluate the clinical impact of quality improvements in EVT management on patients' outcome. Methods All patients treated by EVT at our center during 2012-2021 were divided into two consecutive and equal-sized cohorts (period 1 vs. period 2). Over time several quality improvement strategies were implemented including the earlier diagnosis and EVT treatment and technical optimization of endoscopy. The primary endpoint was defined as the composite score MTL30 (mortality, transfer, length-of-stay > 30 days). Secondary endpoints included EVT efficacy, complications, in-hospital mortality, length-of-stay (LOS) and nutrition status at discharge. Results A total of 156 patients were analyzed. During the latter period the primary endpoint MTL30 decreased from 60.8 to 39.0\% (P = .006). EVT efficacy increased from 80 to 91\% (P = .049). Further, the need for additional procedures for leakage management decreased from 49.9 to 29.9\% (P = .013) and reoperations became less frequent (38.0\% vs.15.6\%; P = .001). The duration of leakage therapy and LOS were shortened from 25 to 14 days (P = .003) and 38 days to 25 days (P = .006), respectively. Morbidity (as determined by the comprehensive complication index) decreased from 54.6 to 46.5 (P = .034). More patients could be discharged on oral nutrition (70.9\% vs. 84.4\%, P = .043). Conclusions Our experience confirms the efficacy of EVT for the successful management of UGI leakage. Our quality improvement analysis demonstrates significant changes in EVT management resulting in accelerated recovery, fewer complications and improved functional outcome.}, language = {en} } @article{ReimerLockFlemmingetal.2022, author = {Reimer, Stanislaus and Lock, Johan F. and Flemming, Sven and Weich, Alexander and Widder, Anna and Plaßmeier, Lars and D{\"o}ring, Anna and Hering, Ilona and Hankir, Mohammed K. and Meining, Alexander and Germer, Christoph-Thomas and Groneberg, Kaja and Seyfried, Florian}, title = {Endoscopic management of large leakages after upper gastrointestinal surgery}, series = {Frontiers in Surgery}, volume = {9}, journal = {Frontiers in Surgery}, issn = {2296-875X}, doi = {10.3389/fsurg.2022.885244}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-274044}, year = {2022}, abstract = {Background Endoscopic vacuum therapy (EVT) is an evidence-based option to treat anastomotic leakages of the upper gastrointestinal (GI) tract, but the technical challenges and clinical outcomes of patients with large defects remain poorly described. Methods All patients with leakages of the upper GI tract that were treated with endoscopic negative pressure therapy at our institution from 2012-2021 were analyzed. Patients with large defects (>30 mm) as an indicator of complex treatment were compared to patients with smaller defects (control group). Results Ninety-two patients with postoperative anastomotic or staplerline leakages were identified, of whom 20 (21.7\%) had large defects. Compared to the control group, these patients required prolonged therapy (42 vs. 14 days, p < 0.001) and hospital stay (63 vs. 26 days, p < 0.001) and developed significantly more septic complications (40 vs. 17.6\%, p = 0.027.) which often necessitated additional endoscopic and/or surgical/interventional treatments (45 vs. 17.4\%, p = 0.007.) Nevertheless, a resolution of leakages was achieved in 80\% of patients with large defects, which was similar compared to the control group (p = 0.42). Multiple leakages, especially on the opposite side, along with other local unfavorable conditions, such as foreign material mass, limited access to the defect or extensive necrosis occurred significantly more often in cases with large defects (p < 0.001). Conclusions Overall, our study confirms that EVT for leakages even from large defects of the upper GI tract is feasible in most cases but comes with significant technical challenges.}, language = {en} } @article{LuxBanckSassmannshausenetal.2022, author = {Lux, Thomas J. and Banck, Michael and Saßmannshausen, Zita and Troya, Joel and Krenzer, Adrian and Fitting, Daniel and Sudarevic, Boban and Zoller, Wolfram G. and Puppe, Frank and Meining, Alexander and Hann, Alexander}, title = {Pilot study of a new freely available computer-aided polyp detection system in clinical practice}, series = {International Journal of Colorectal Disease}, volume = {37}, journal = {International Journal of Colorectal Disease}, number = {6}, doi = {10.1007/s00384-022-04178-8}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324459}, pages = {1349-1354}, year = {2022}, abstract = {Purpose Computer-aided polyp detection (CADe) systems for colonoscopy are already presented to increase adenoma detection rate (ADR) in randomized clinical trials. Those commercially available closed systems often do not allow for data collection and algorithm optimization, for example regarding the usage of different endoscopy processors. Here, we present the first clinical experiences of a, for research purposes publicly available, CADe system. Methods We developed an end-to-end data acquisition and polyp detection system named EndoMind. Examiners of four centers utilizing four different endoscopy processors used EndoMind during their clinical routine. Detected polyps, ADR, time to first detection of a polyp (TFD), and system usability were evaluated (NCT05006092). Results During 41 colonoscopies, EndoMind detected 29 of 29 adenomas in 66 of 66 polyps resulting in an ADR of 41.5\%. Median TFD was 130 ms (95\%-CI, 80-200 ms) while maintaining a median false positive rate of 2.2\% (95\%-CI, 1.7-2.8\%). The four participating centers rated the system using the System Usability Scale with a median of 96.3 (95\%-CI, 70-100). Conclusion EndoMind's ability to acquire data, detect polyps in real-time, and high usability score indicate substantial practical value for research and clinical practice. Still, clinical benefit, measured by ADR, has to be determined in a prospective randomized controlled trial.}, language = {en} } @article{KelmReibetanzKimetal.2022, author = {Kelm, Matthias and Reibetanz, Joachim and Kim, Mia and Schoettker, Kathrin and Brand, Markus and Meining, Alexander and Germer, Christoph-Thomas and Flemming, Sven}, title = {Kono-S anastomosis in Crohn's disease: A retrospective study on postoperative morbidity and disease recurrence in comparison to the conventional side-to-side anastomosis}, series = {Journal of Clinical Medicine}, volume = {11}, journal = {Journal of Clinical Medicine}, number = {23}, issn = {2077-0383}, doi = {10.3390/jcm11236915}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-297334}, year = {2022}, abstract = {Introduction: The rates of postoperative recurrence following ileocecal resection due to Crohn's disease remain highly relevant. Despite this fact, while the Kono-S anastomosis technique initially demonstrated promising results, robust evidence is still lacking. This study aimed to analyze the short- and long-term outcomes of the Kono-S versus side-to-side anastomosis. Methods: A retrospective single-center study was performed including all patients who received an ileocecal resection between 1 January 2019 and 31 December 2021 at the Department of Surgery at the University Hospital of Wuerzburg. Patients who underwent conventional a side-to-side anastomosis were compared to those who received a Kono-S anastomosis. The short- and long-term outcomes were analyzed for all patients. Results: Here, 29 patients who underwent a conventional side-to-side anastomosis and 22 patients who underwent a Kono-S anastomosis were included. No differences were observed regarding short-term postoperative outcomes. The disease recurrence rate postoperatively was numerically lower following the Kono-S anastomosis (median Rutgeert score of 1.7 versus 2.5), with a relevantly increased rate of patients in remission (17.2\% versus 31.8\%); however, neither of these results reached statistical significance. Conclusion: The Kono-S anastomosis method is safe and feasible and potentially decreases the severity of postoperative disease remission.}, language = {en} } @article{JendretzkiHennigerSchiffmannetal.2022, author = {Jendretzki, Julia and Henniger, Dorothea and Schiffmann, Lisa and Wolz, Constanze and Kollikowski, Anne and Meining, Alexander and Einsele, Hermann and Winkler, Marcela and L{\"o}ffler, Claudia}, title = {Every fifth patient suffered a high nutritional risk — Results of a prospective patient survey in an oncological outpatient center}, series = {Frontiers in Nutrition}, volume = {9}, journal = {Frontiers in Nutrition}, issn = {2296-861X}, doi = {10.3389/fnut.2022.1033265}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-311284}, year = {2022}, abstract = {Introduction Malnutrition in cancer patients often remains undetected and underestimated in clinical practice despite studies revealing prevalences from 20 to 70\%. Therefore, this study aimed to identify patient groups exposed to an increased nutritional risk in a university oncological outpatient center. Methods Between May 2017 and January 2018 we screened oncological patients there using the malnutrition universal screening tool (MUST). Qualitative data were collected by a questionnaire to learn about patients' individual information needs and changes in patients' diets and stressful personal nutrition restrictions. Results We included 311 patients with various cancers. 20.3\% (n = 63) were found to be at high risk of malnutrition, 16.4\% (n = 51) at moderate risk despite a mean body mass index (BMI) of 26.5 ± 4.7 kg/m2. The average age was 62.7 (± 11.8) with equal gender distribution (52\% women, n = 162). In 94.8\% (n = 295) unintended weight loss led to MUST scoring. Patients with gastrointestinal tumors (25\%, n = 78) and patients >65 years (22\%, n = 68) were at higher risk. Furthermore, there was a significant association between surgery or chemotherapy within six months before survey and a MUST score ≥2 (OR = 3.6). Taste changes, dysphagia, and appetite loss were also particular risk factors (OR = 2.3-3.2). Young, female and normal-weight patients showed most interest in nutrition in cancer. However, only 38\% (n = 118) had a nutritional counseling. Conclusion This study confirms that using the MUST score is a valid screening procedure to identify outpatients at risk of developing malnutrition. Here one in five was at high risk, but only 1\% would have been detected by BMI alone. Therefore, an ongoing screening procedure with meaningful parameters should be urgently implemented into the clinical routine of cancer outpatients as recommended in international guidelines.}, language = {en} } @article{BrandTroyaKrenzeretal.2022, author = {Brand, Markus and Troya, Joel and Krenzer, Adrian and Saßmannshausen, Zita and Zoller, Wolfram G. and Meining, Alexander and Lux, Thomas J. and Hann, Alexander}, title = {Development and evaluation of a deep learning model to improve the usability of polyp detection systems during interventions}, series = {United European Gastroenterology Journal}, volume = {10}, journal = {United European Gastroenterology Journal}, number = {5}, doi = {10.1002/ueg2.12235}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-312708}, pages = {477-484}, year = {2022}, abstract = {Background The efficiency of artificial intelligence as computer-aided detection (CADe) systems for colorectal polyps has been demonstrated in several randomized trials. However, CADe systems generate many distracting detections, especially during interventions such as polypectomies. Those distracting CADe detections are often induced by the introduction of snares or biopsy forceps as the systems have not been trained for such situations. In addition, there are a significant number of non-false but not relevant detections, since the polyp has already been previously detected. All these detections have the potential to disturb the examiner's work. Objectives Development and evaluation of a convolutional neuronal network that recognizes instruments in the endoscopic image, suppresses distracting CADe detections, and reliably detects endoscopic interventions. Methods A total of 580 different examination videos from 9 different centers using 4 different processor types were screened for instruments and represented the training dataset (519,856 images in total, 144,217 contained a visible instrument). The test dataset included 10 full-colonoscopy videos that were analyzed for the recognition of visible instruments and detections by a commercially available CADe system (GI Genius, Medtronic). Results The test dataset contained 153,623 images, 8.84\% of those presented visible instruments (12 interventions, 19 instruments used). The convolutional neuronal network reached an overall accuracy in the detection of visible instruments of 98.59\%. Sensitivity and specificity were 98.55\% and 98.92\%, respectively. A mean of 462.8 frames containing distracting CADe detections per colonoscopy were avoided using the convolutional neuronal network. This accounted for 95.6\% of all distracting CADe detections. Conclusions Detection of endoscopic instruments in colonoscopy using artificial intelligence technology is reliable and achieves high sensitivity and specificity. Accordingly, the new convolutional neuronal network could be used to reduce distracting CADe detections during endoscopic procedures. Thus, our study demonstrates the great potential of artificial intelligence technology beyond mucosal assessment.}, language = {en} } @article{BrandReimerReibetanzetal.2021, author = {Brand, Markus and Reimer, Stanislaus and Reibetanz, Joachim and Flemming, Sven and Kornmann, Marko and Meining, Alexander}, title = {Endoscopic full thickness resection vs. transanal endoscopic microsurgery for local treatment of rectal neuroendocrine tumors - a retrospective analysis}, series = {International Journal of Colorectal Disease}, volume = {36}, journal = {International Journal of Colorectal Disease}, issn = {0179-1958}, doi = {10.1007/s00384-020-03800-x}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-234833}, pages = {971-976}, year = {2021}, abstract = {Purpose Local treatment of small well-differentiated rectal neuroendocrine tumors (NETs) is recommended by current guidelines. However, although several endoscopic methods have been established, the highest R0 rate is achieved by transanal endoscopic microsurgery (TEM). Since a recently published study about endoscopic full thickness resection (eFTR) showed a R0 resection rate of 100\%, the aim of this study was to evaluate both methods (eFTR vs. TEM). Methods We retrospectively analyzed all patients with rectal NET treated either by TEM (1999-2018) or eFTR (2016-2019) in two tertiary centers (University Hospital Wuerzburg and Ulm). We analyzed clinical, procedural, and histopathological outcomes in both groups. Results Twenty-eight patients with rectal NET received local treatment (TEM: 13; eFTR: 15). Most tumors were at stage T1a and grade G1 or G2 (in the TEM group two G3 NETs were staged T2 after neoadjuvant chemotherapy). In both groups, similar outcomes for en bloc resection rate, R0 resection rate, tumor size, or specimen size were found. No procedural adverse events were noted. Mean procedure time in the TEM group was 48.9 min and 19.2 min in the eFTR group. Conclusion eFTR is a convincing method for local treatment of small rectal NETs combining high safety and efficacy with short interventional time.}, language = {en} }