@article{UeceylerHomolaGonzalezetal.2014, author = {{\"U}{\c{c}}eyler, Nurcan and Homola, Gy{\"o}rgy A. and Gonz{\´a}lez, Hans Guerrero and Kramer, Daniela and Wanner, Christoph and Weidemann, Frank and Solymosi, L{\´a}szl{\´o} and Sommer, Claudia}, title = {Increased Arterial Diameters in the Posterior Cerebral Circulation in Men with Fabry Disease}, doi = {10.1371/journal.pone.0087054}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-112614}, year = {2014}, abstract = {A high load of white matter lesions and enlarged basilar arteries have been shown in selected patients with Fabry disease, a disorder associated with an increased stroke risk. We studied a large cohort of patients with Fabry disease to differentially investigate white matter lesion load and cerebral artery diameters. We retrospectively analyzed cranial magnetic resonance imaging scans of 87 consecutive Fabry patients, 20 patients with ischemic stroke, and 36 controls. We determined the white matter lesion load applying the Fazekas score on fluid-attenuated inversion recovery sequences and measured the diameters of cerebral arteries on 3D-reconstructions of the time-of-flight-MR-angiography scans. Data of different Fabry patient subgroups (males - females; normal - impaired renal function) were compared with data of patients with stroke and controls. A history of stroke or transient ischemic attacks was present in 4/30 males (13\%) and 5/57 (9\%) females with Fabry disease, all in the anterior circulation. Only one man with Fabry disease showed confluent cerebral white matter lesions in the Fazekas score assessment (1\%). Male Fabry patients had a larger basilar artery (p<0.01) and posterior cerebral artery diameter (p<0.05) compared to male controls. This was independent of disease severity as measured by renal function and did not lead to changes in arterial blood flow properties. A basilar artery diameter of >3.2 mm distinguished between men with Fabry disease and controls (sensitivity: 87\%, specificity: 86\%, p<0.001), but not from stroke patients. Enlarged arterial diameters of the posterior circulation are present only in men with Fabry disease independent of disease severity.}, language = {en} } @phdthesis{Ye2013, author = {Ye, Yuxiang}, title = {Molecular and Cellular Magnetic Resonance Imaging of Myocardial Infarct Healing}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-72514}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2013}, abstract = {Myokardinfarkte (MI) sind eine der h{\"a}ufigsten Todesursachen weltweit. Eine rechtzeitige Wiederherstellung des koronaren Blutflusses im isch{\"a}mischen Myokard reduziert signifikant die Sterblichkeitsrate akuter Infarkte und vermindert das ventrikul{\"a}re Remodeling. {\"U}berlebende MI-Patienten entwickeln jedoch h{\"a}ufig eine Herzinsuffizienz, die mit einer reduzierten Lebensqualit{\"a}t, hohen Sterblichkeitsrate (10\% j{\"a}hrlich), sowie hohen Kosten f{\"u}r das Gesundheitssystem einhergeht. Die Entwicklung der Herzinsuffizienz nach einem MI ist auf den hohen Verlust kontraktiler Kardiomyozyten, w{\"a}hrend der Isch{\"a}mie-Reperfusion zur{\"u}ckzuf{\"u}hren. Anschließende komplexe strukturelle und funktionelle Ver{\"a}nderungen resultieren aus Modifikationen des infarzierten und nicht infarzierten Myokards auf molekularer und zellul{\"a}rer Ebene. Die verbesserte {\"U}berlebensrate von Patienten mit akutem MI und das Fehlen effizienter Therapien, die die Entwicklung und das Fortschreiten des ventrikul{\"a}ren Remodelings verhindern, f{\"u}hren zu einer hohen Pr{\"a}valenz der Herzinsuffizienz. Die kardiale Magnetresonanztomographie (MRT) ist eine wichtige Methode zur Diagnose und Beurteilung des Myokardinfarktes. Mit dem technologischen Fortschritt wurden die Grenzen der MRT erweitert, so dass es heute m{\"o}glich ist, auch molekulare und zellul{\"a}re Ereignisse in vivo und nicht-invasiv zu untersuchen. In Kombination mit kardialer Morphologie und Funktion k{\"o}nnte die Visualisierung essentieller molekularer und zellul{\"a}rer Marker in vivo weitreichende Einblicke in den Heilungsprozess infarzierter Herzen liefern, was zu neuen Erkenntnissen f{\"u}r ein besseres Verst{\"a}ndnis und bessere Therapien des akuten MI f{\"u}hren k{\"o}nnte. In dieser Arbeit wurden Methoden f{\"u}r die molekulare und zellul{\"a}re kardiale MRT-Bildgebung der Inflammation und des Kalziumstroms im Heilungsprozess des akuten Myokardinfarktes in vivo in einem Rattenmodel mit klinischer Relevanz etabliert.}, subject = {Kernspintomografie}, language = {en} } @article{WeiseBasseLuesebrinkKleinschnitzetal.2011, author = {Weise, Gesa and Basse-L{\"u}sebrink, Thomas C. and Kleinschnitz, Christoph and Kampf, Thomas and Jakob, Peter M. and Stoll, Guido}, title = {In Vivo Imaging of Stepwise Vessel Occlusion in Cerebral Photothrombosis of Mice by \(^{19}\)F MRI}, series = {PLoS One}, volume = {6}, journal = {PLoS One}, number = {12}, doi = {10.1371/journal.pone.0028143}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-137792}, pages = {e28143}, year = {2011}, abstract = {Background \(^{19}\)F magnetic resonance imaging (MRI) was recently introduced as a promising technique for in vivo cell tracking. In the present study we compared \(^{19}\)F MRI with iron-enhanced MRI in mice with photothrombosis (PT) at 7 Tesla. PT represents a model of focal cerebral ischemia exhibiting acute vessel occlusion and delayed neuroinflammation. Methods/Principal Findings Perfluorocarbons (PFC) or superparamagnetic iron oxide particles (SPIO) were injected intravenously at different time points after photothrombotic infarction. While administration of PFC directly after PT induction led to a strong \(^{19}\)F signal throughout the entire lesion, two hours delayed application resulted in a rim-like \(^{19}\)F signal at the outer edge of the lesion. These findings closely resembled the distribution of signal loss on T2-weighted MRI seen after SPIO injection reflecting intravascular accumulation of iron particles trapped in vessel thrombi as confirmed histologically. By sequential administration of two chemically shifted PFC compounds 0 and 2 hours after illumination the different spatial distribution of the \(^{19}\)F markers (infarct core/rim) could be visualized in the same animal. When PFC were applied at day 6 the fluorine marker was only detected after long acquisition times ex vivo. SPIO-enhanced MRI showed slight signal loss in vivo which was much more prominent ex vivo indicative for neuroinflammation at this late lesion stage. Conclusion Our study shows that vessel occlusion can be followed in vivo by \(^{19}\)F and SPIO-enhanced high-field MRI while in vivo imaging of neuroinflammation remains challenging. The timing of contrast agent application was the major determinant of the underlying processes depicted by both imaging techniques. Importantly, sequential application of different PFC compounds allowed depiction of ongoing vessel occlusion from the core to the margin of the ischemic lesions in a single MRI measurement.}, language = {en} } @article{WeibelBasseLuesebrinkHessetal.2013, author = {Weibel, Stephanie and Basse-Luesebrink, Thomas Christian and Hess, Michael and Hofmann, Elisabeth and Seubert, Carolin and Langbein-Laugwitz, Johanna and Gentschev, Ivaylo and Sturm, Volker J{\"o}rg Friedrich and Ye, Yuxiang and Kampf, Thomas and Jakob, Peter Michael and Szalay, Aladar A.}, title = {Imaging of Intratumoral Inflammation during Oncolytic Virotherapy of Tumors by \(^{19}\)F-Magnetic Resonance Imaging (MRI)}, series = {PLoS ONE}, volume = {8}, journal = {PLoS ONE}, number = {3}, doi = {10.1371/journal.pone.0056317}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-130311}, pages = {e56317}, year = {2013}, abstract = {Background Oncolytic virotherapy of tumors is an up-coming, promising therapeutic modality of cancer therapy. Unfortunately, non-invasive techniques to evaluate the inflammatory host response to treatment are rare. Here, we evaluate \(^{19}\)F magnetic resonance imaging (MRI) which enables the non-invasive visualization of inflammatory processes in pathological conditions by the use of perfluorocarbon nanoemulsions (PFC) for monitoring of oncolytic virotherapy. Methodology/Principal Findings The Vaccinia virus strain GLV-1h68 was used as an oncolytic agent for the treatment of different tumor models. Systemic application of PFC emulsions followed by \(^1H\)/\(^{19}\)F MRI of mock-infected and GLV-1h68-infected tumor-bearing mice revealed a significant accumulation of the \(^{19}\)F signal in the tumor rim of virus-treated mice. Histological examination of tumors confirmed a similar spatial distribution of the \(^{19}\)F signal hot spots and \(CD68^+\)-macrophages. Thereby, the \(CD68^+\)-macrophages encapsulate the GFP-positive viral infection foci. In multiple tumor models, we specifically visualized early inflammatory cell recruitment in Vaccinia virus colonized tumors. Furthermore, we documented that the \(^{19}\)F signal correlated with the extent of viral spreading within tumors. Conclusions/Significance These results suggest \(^{19}\)F MRI as a non-invasive methodology to document the tumor-associated host immune response as well as the extent of intratumoral viral replication. Thus, \(^{19}\)F MRI represents a new platform to non-invasively investigate the role of the host immune response for therapeutic outcome of oncolytic virotherapy and individual patient response.}, language = {en} } @article{TranGiaWechBleyetal.2015, author = {Tran-Gia, Johannes and Wech, Tobias and Bley, Thorsten and K{\"o}stler, Herbert}, title = {Model-Based Acceleration of Look-Locker T1 Mapping}, series = {PLoS One}, volume = {10}, journal = {PLoS One}, number = {4}, doi = {10.1371/journal.pone.0122611}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-126436}, pages = {e0122611}, year = {2015}, abstract = {Mapping the longitudinal relaxation time \(T_1\) has widespread applications in clinical MRI as it promises a quantitative comparison of tissue properties across subjects and scanners. Due to the long scan times of conventional methods, however, the use of quantitative MRI in clinical routine is still very limited. In this work, an acceleration of Inversion-Recovery Look-Locker (IR-LL) \(T_1\) mapping is presented. A model-based algorithm is used to iteratively enforce an exponential relaxation model to a highly undersampled radially acquired IR-LL dataset obtained after the application of a single global inversion pulse. Using the proposed technique, a \(T_1\) map of a single slice with 1.6mm in-plane resolution and 4mm slice thickness can be reconstructed from data acquired in only 6s. A time-consuming segmented IR experiment was used as gold standard for \(T_1\) mapping in this work. In the subsequent validation study, the model-based reconstruction of a single-inversion IR-LL dataset exhibited a \(T_1\) difference of less than 2.6\% compared to the segmented IR-LL reference in a phantom consisting of vials with \(T_1\) values between 200ms and 3000ms. In vivo, the \(T_1\) difference was smaller than 5.5\% in WM and GM of seven healthy volunteers. Additionally, the \(T_1\) values are comparable to standard literature values. Despite the high acceleration, all model-based reconstructions were of a visual quality comparable to fully sampled references. Finally, the reproducibility of the \(T_1\) mapping method was demonstrated in repeated acquisitions. In conclusion, the presented approach represents a promising way for fast and accurate \(T_1\) mapping using radial IR-LL acquisitions without the need of any segmentation.}, language = {en} } @article{TerekhovElabyadSchreiber2021, author = {Terekhov, Maxim and Elabyad, Ibrahim A. and Schreiber, Laura M.}, title = {Global optimization of default phases for parallel transmit coils for ultra-high-field cardiac MRI}, series = {PLoS One}, volume = {16}, journal = {PLoS One}, number = {8}, doi = {10.1371/journal.pone.0255341}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-265737}, year = {2021}, abstract = {The development of novel multiple-element transmit-receive arrays is an essential factor for improving B\(_1\)\(^+\) field homogeneity in cardiac MRI at ultra-high magnetic field strength (B\(_0\) > = 7.0T). One of the key steps in the design and fine-tuning of such arrays during the development process is finding the default driving phases for individual coil elements providing the best possible homogeneity of the combined B\(_1\)\(^+\)-field that is achievable without (or before) subject-specific B\(_1\)\(^+\)-adjustment in the scanner. This task is often solved by time-consuming (brute-force) or by limited efficiency optimization methods. In this work, we propose a robust technique to find phase vectors providing optimization of the B-1-homogeneity in the default setup of multiple-element transceiver arrays. The key point of the described method is the pre-selection of starting vectors for the iterative solver-based search to maximize the probability of finding a global extremum for a cost function optimizing the homogeneity of a shaped B\(_1\)\(^+\)-field. This strategy allows for (i) drastic reduction of the computation time in comparison to a brute-force method and (ii) finding phase vectors providing a combined B\(_1\)\(^+\)-field with homogeneity characteristics superior to the one provided by the random-multi-start optimization approach. The method was efficiently used for optimizing the default phase settings in the in-house-built 8Tx/16Rx arrays designed for cMRI in pigs at 7T.}, language = {en} } @article{SchneiderHoehneSchneideretal.2022, author = {Schneider, Sonja Jasmin Maria and H{\"o}hne, Christian and Schneider, Martin and Schmitter, Marc}, title = {Photoacoustic tomography versus cone-beam computed tomography versus micro-computed tomography: Accuracy of 3D reconstructions of human teeth}, series = {PloS One}, volume = {17}, journal = {PloS One}, number = {12}, doi = {10.1371/journal.pone.0274818}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-301437}, year = {2022}, abstract = {Objectives In this in-vitro study, teeth were imaged using photoacoustic tomography (PAT), cone-beam computed tomography (CBCT), and micro-computed tomography (μ-CT). The study had aim: to identify the best wavelength for PAT images to determine the accuracy of the three imaging methods, and to determine whether PAT images of teeth can achieve acceptable reconstruction quality. Methods Nineteen human mandibular single-rooted incisors were extracted from patients with trauma or periodontitis. To determine the best wavelength for acquiring photoacoustic images, all 19 teeth were scanned in vitro with PAT, using different laser wavelengths between 680 and 960 nm. The images were analyzed using image analysis software. To assess the accuracy of PAT and compare it with the accuracy of CBCT, each tooth was also scanned in vitro using CBCT and the reference standard technique of μ-CT. Subsequently, three different three-dimensional models, one for each imaging technique, were created for each tooth. Finally, the three different three-dimensional models acquired for the same tooth were matched and analyzed regarding volume and surface. Results The highest quality tooth images were achieved using the 680 nm wavelength, which showed the best contrast ratio. The full geometry of the dental root (μ-CT compared with PAT) could be visualized with relative standard deviations of 0.12 mm for the surface and -7.33 mm3 for the volume (n = 19). The full geometry of the dental root (μ-CT compared with CBCT) could be visualized with relative standard deviations of 0.06 mm for the surface and -14.56 mm3 for the volume (n = 19). The difference between the PAT-μ-CT group and CBCT-μ-CT group regarding the total average of the root surface area was not significant (p>0.06). Conclusion Images, which were acquired using PAT at 680nm showed the best contrast ration, enabling the identification of dentin, cementum and the dental pulp. No significant differences were found between the PAT-μ-CT group and CBCT-μ-CT group regarding the total average of the RSA and the total volume. Thus, three-dimensional reconstructions based on in-vitro PAT are already of acceptable reconstruction quality.}, language = {en} } @article{SchnabelCamenKnebeletal.2021, author = {Schnabel, Renate B. and Camen, Stephan and Knebel, Fabian and Hagendorff, Andreas and Bavendiek, Udo and B{\"o}hm, Michael and Doehner, Wolfram and Endres, Matthias and Gr{\"o}schel, Klaus and Goette, Andreas and Huttner, Hagen B. and Jensen, Christoph and Kirchhof, Paulus and Korosoglou, Grigorius and Laufs, Ulrich and Liman, Jan and Morbach, Caroline and Navabi, Darius G{\"u}nther and Neumann-Haefelin, Tobias and Pfeilschifter, Waltraut and Poli, Sven and Rizos, Timolaos and Rolf, Andreas and R{\"o}ther, Joachim and Sch{\"a}bitz, Wolf R{\"u}diger and Steiner, Thorsten and Thomalla, G{\"o}tz and Wachter, Rolf and Haeusler, Karl Georg}, title = {Expert opinion paper on cardiac imaging after ischemic stroke}, series = {Clinical Research in Cardiology}, volume = {110}, journal = {Clinical Research in Cardiology}, number = {7}, issn = {1861-0692}, doi = {10.1007/s00392-021-01834-x}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-266662}, pages = {938-958}, year = {2021}, abstract = {This expert opinion paper on cardiac imaging after acute ischemic stroke or transient ischemic attack (TIA) includes a statement of the "Heart and Brain" consortium of the German Cardiac Society and the German Stroke Society. The Stroke Unit-Commission of the German Stroke Society and the German Atrial Fibrillation NETwork (AFNET) endorsed this paper. Cardiac imaging is a key component of etiological work-up after stroke. Enhanced echocardiographic tools, constantly improving cardiac computer tomography (CT) as well as cardiac magnetic resonance imaging (MRI) offer comprehensive non- or less-invasive cardiac evaluation at the expense of increased costs and/or radiation exposure. Certain imaging findings usually lead to a change in medical secondary stroke prevention or may influence medical treatment. However, there is no proof from a randomized controlled trial (RCT) that the choice of the imaging method influences the prognosis of stroke patients. Summarizing present knowledge, the German Heart and Brain consortium proposes an interdisciplinary, staged standard diagnostic scheme for the detection of risk factors of cardio-embolic stroke. This expert opinion paper aims to give practical advice to physicians who are involved in stroke care. In line with the nature of an expert opinion paper, labeling of classes of recommendations is not provided, since many statements are based on expert opinion, reported case series, and clinical experience.}, language = {en} } @article{RullmannPreusserPoppitzetal.2019, author = {Rullmann, Michael and Preusser, Sven and Poppitz, Sindy and Heba, Stefanie and Gousias, Konstantinos and Hoyer, Jana and Sch{\"u}tz, Tatjana and Dietrich, Arne and M{\"u}ller, Karsten and Hankir, Mohammed K. and Pleger, Burkhard}, title = {Adiposity Related Brain Plasticity Induced by Bariatric Surgery}, series = {Froniers in Human Neuroscience}, volume = {13}, journal = {Froniers in Human Neuroscience}, doi = {10.3389/fnhum.2019.00290}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-227168}, pages = {1-11}, year = {2019}, abstract = {Previous magnetic resonance imaging (MRI) studies revealed structural-functional brain reorganization 12 months after gastric-bypass surgery, encompassing cortical and subcortical regions of all brain lobes as well as the cerebellum. Changes in the mean of cluster-wise gray/white matter density (GMD/WMD) were correlated with the individual loss of body mass index (BMI), rendering the BMI a potential marker of widespread surgery-induced brain plasticity. Here, we investigated voxel-by-voxel associations between surgery-induced changes in adiposity, metabolism and inflammation and markers of functional and structural neural plasticity. We re-visited the data of patients who underwent functional and structural MRI, 6 months (n = 27) and 12 months after surgery (n = 22), and computed voxel-wise regression analyses. Only the surgery-induced weight loss was significantly associated with brain plasticity, and this only for GMD changes. After 6 months, weight loss overlapped with altered GMD in the hypothalamus, the brain's homeostatic control site, the lateral orbitofrontal cortex, assumed to host reward and gustatory processes, as well as abdominal representations in somatosensory cortex. After 12 months, weight loss scaled with GMD changes in right cerebellar lobule VII, involved in language-related/cognitive processes, and, by trend, with the striatum, assumed to underpin (food) reward. These findings suggest time-dependent and weight-loss related gray matter plasticity in brain regions involved in the control of eating, sensory processing and cognitive functioning.}, language = {en} } @phdthesis{Portmann2023, author = {Portmann, Johannes}, title = {Accelerated inversion recovery MRI of the myocardium using spiral acquisition}, doi = {10.25972/OPUS-30282}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-302822}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2023}, abstract = {This work deals with the acceleration of cardiovascular MRI for the assessment of functional information in steady-state contrast and for viability assessment during the inversion recovery of the magnetization. Two approaches are introduced and discussed in detail. MOCO-MAP uses an exponential model to recover dynamic image data, IR-CRISPI, with its low-rank plus sparse reconstruction, is related to compressed sensing. MOCO-MAP is a successor to model-based acceleration of parametermapping (MAP) for the application in the myocardial region. To this end, it was augmented with a motion correction (MOCO) step to allow exponential fitting the signal of a still object in temporal direction. Iteratively, this introduction of prior physical knowledge together with the enforcement of consistency with the measured data can be used to reconstruct an image series from distinctly shorter sampling time than the standard exam (< 3 s opposed to about 10 s). Results show feasibility of the method as well as detectability of delayed enhancement in the myocardium, but also significant discrepancies when imaging cardiac function and artifacts caused already by minor inaccuracy of the motion correction. IR-CRISPI was developed from CRISPI, which is a real-time protocol specifically designed for functional evaluation of image data in steady-state contrast. With a reconstruction based on the separate calculation of low-rank and sparse part, it employs a softer constraint than the strict exponential model, which was possible due to sufficient temporal sampling density via spiral acquisition. The low-rank plus sparse reconstruction is fit for the use on dynamic and on inversion recovery data. Thus, motion correction is rendered unnecessary with it. IR-CRISPI was equipped with noise suppression via spatial wavelet filtering. A study comprising 10 patients with cardiac disease show medical applicability. A comparison with performed traditional reference exams offer insight into diagnostic benefits. Especially regarding patients with difficulty to hold their breath, the real-time manner of the IR-CRISPI acquisition provides a valuable alternative and an increase in robustness. In conclusion, especially with IR-CRISPI in free breathing, a major acceleration of the cardiovascular MR exam could be realized. In an acquisition of less than 100 s, it not only includes the information of two traditional protocols (cine and LGE), which take up more than 9.6 min, but also allows adjustment of TI in retrospect and yields lower artifact level with similar image quality.}, subject = {Kernspintomografie}, language = {en} }