@article{ZhouWuchterEgereretal.2019, author = {Zhou, Xiang and Wuchter, Patrick and Egerer, Gerlinde and Kriegsmann, Mark and Mataityte, Aiste and Koelsche, Christian and Witzens-Harig, Mathias and Kriegsmann, Katharina}, title = {Role of virological serum markers in patients with both hepatitis B virus infection and diffuse large B-cell lymphoma}, series = {European Journal of Haematology}, volume = {103}, journal = {European Journal of Haematology}, number = {4}, doi = {10.1111/ejh.13300}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-258442}, pages = {410-416}, year = {2019}, abstract = {Background Causality between hepatitis B virus (HBV) infection and diffuse large B-cell lymphoma (DLBCL) was reported in various studies. However, the implication of different virological serum markers of HBV infection in patients with both HBV infection and DLBCL is not fully understood. The aim of this study was to investigate the impact of HBV markers on overall survival (OS) and progression-free survival (PFS) in patients with both HBV infection and DLBCL. Methods In this study, patients (n = 40) diagnosed with both HBV infection and DLBCL were identified between 2000 and 2017. Six patients with hepatitis C virus (HCV) and/or human immunodeficiency virus (HIV) co-infection were excluded from this study. We retrospectively analyzed patients' demographic characteristics, treatment, and the prognostic impact of different HBV markers at first diagnosis of DLBCL (HBsAg, anti-HBs, HBeAg, anti-HBe, and HBV-DNA) on OS and PFS. Results The majority of patients (n = 21, 62\%) had advanced disease stage (III/IV) at diagnosis. In the first-line therapy, 24 patients (70\%) were treated with R-CHOP regimen (rituximab, cyclophosphamide, hydroxydaunorubicin, vincristine, and prednisolone). HBeAg positive patients had a trend toward inferior OS and PFS compared with HBeAg negative patients. Anti-HBe positive patients had a statistically significant better OS and PFS compared with anti-HBe negative group (both P < .0001). Viremia with HBV-DNA ≥ 2 × 107 IU/L had a significant negative impact on OS and PFS (both P < .0001). Conclusion High activity of viral replication is associated with a poor survival outcome of patients with both HBV infection and DLBCL.}, language = {en} } @article{WinterAndelovicKampfetal.2021, author = {Winter, Patrick M. and Andelovic, Kristina and Kampf, Thomas and Hansmann, Jan and Jakob, Peter Michael and Bauer, Wolfgang Rudolf and Zernecke, Alma and Herold, Volker}, title = {Simultaneous measurements of 3D wall shear stress and pulse wave velocity in the murine aortic arch}, series = {Journal of Cardiovascular Magnetic Resonance}, volume = {23}, journal = {Journal of Cardiovascular Magnetic Resonance}, number = {1}, doi = {10.1186/s12968-021-00725-4}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-259152}, pages = {34}, year = {2021}, abstract = {Purpose Wall shear stress (WSS) and pulse wave velocity (PWV) are important parameters to characterize blood flow in the vessel wall. Their quantification with flow-sensitive phase-contrast (PC) cardiovascular magnetic resonance (CMR), however, is time-consuming. Furthermore, the measurement of WSS requires high spatial resolution, whereas high temporal resolution is necessary for PWV measurements. For these reasons, PWV and WSS are challenging to measure in one CMR session, making it difficult to directly compare these parameters. By using a retrospective approach with a flexible reconstruction framework, we here aimed to simultaneously assess both PWV and WSS in the murine aortic arch from the same 4D flow measurement. Methods Flow was measured in the aortic arch of 18-week-old wildtype (n = 5) and ApoE\(^{-/-}\) mice (n = 5) with a self-navigated radial 4D-PC-CMR sequence. Retrospective data analysis was used to reconstruct the same dataset either at low spatial and high temporal resolution (PWV analysis) or high spatial and low temporal resolution (WSS analysis). To assess WSS, the aortic lumen was labeled by semi-automatically segmenting the reconstruction with high spatial resolution. WSS was determined from the spatial velocity gradients at the lumen surface. For calculation of the PWV, segmentation data was interpolated along the temporal dimension. Subsequently, PWV was quantified from the through-plane flow data using the multiple-points transit-time method. Reconstructions with varying frame rates and spatial resolutions were performed to investigate the influence of spatiotemporal resolution on the PWV and WSS quantification. Results 4D flow measurements were conducted in an acquisition time of only 35 min. Increased peak flow and peak WSS values and lower errors in PWV estimation were observed in the reconstructions with high temporal resolution. Aortic PWV was significantly increased in ApoE\(^{-/-}\) mice compared to the control group (1.7 ± 0.2 versus 2.6 ± 0.2 m/s, p < 0.001). Mean WSS magnitude values averaged over the aortic arch were (1.17 ± 0.07) N/m\(^2\) in wildtype mice and (1.27 ± 0.10) N/m\(^2\) in ApoE\(^{-/-}\) mice. Conclusion The post processing algorithm using the flexible reconstruction framework developed in this study permitted quantification of global PWV and 3D-WSS in a single acquisition. The possibility to assess both parameters in only 35 min will markedly improve the analyses and information content of in vivo measurements.}, language = {en} } @article{WestermaierLinsenmannHomolaetal.2016, author = {Westermaier, Thomas and Linsenmann, Thomas and Homola, Gy{\"o}rgy A. and Loehr, Mario and Stetter, Christian and Willner, Nadine and Ernestus, Ralf-Ingo and Soymosi, Laszlo and Vince, Giles H.}, title = {3D rotational fluoroscopy for intraoperative clip control in patients with intracranial aneurysms - assessment of feasibility and image quality}, series = {BMC Medical Imaging}, volume = {16}, journal = {BMC Medical Imaging}, number = {30}, doi = {10.1186/s12880-016-0133-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-146381}, year = {2016}, abstract = {Background Mobile 3D fluoroscopes have become increasingly available in neurosurgical operating rooms. In this series, the image quality and value of intraoperative 3D fluoroscopy with intravenous contrast agent for the evaluation of aneurysm occlusion and vessel patency after clip placement was assessed in patients who underwent surgery for intracranial aneurysms. Materials and methods Twelve patients were included in this retrospective analysis. Prior to surgery, a 360° rotational fluoroscopy scan was performed without contrast agent followed by another scan with 50 ml of intravenous iodine contrast agent. The image files of both scans were transferred to an Apple PowerMac® workstation, subtracted and reconstructed using OsiriX® free software. The procedure was repeated after clip placement. Both image sets were compared for assessment of aneurysm occlusion and vessel patency. Results Image acquisition and contrast administration caused no adverse effects. Image quality was sufficient to follow the patency of the vessels distal to the clip. Metal artifacts reduce the assessability of the immediate vicinity of the clip. Precise image subtraction and post-processing can reduce metal artifacts and make the clip-site assessable and depict larger neck-remnants. Conclusion This technique quickly supplies images at adequate quality to evaluate distal vessel patency after aneurysm clipping. Significant aneurysm remnants may be depicted as well. As it does not require visual control of all vessels that are supposed to be evaluated intraoperatively, this technique may be complementary to other intraoperative tools like indocyanine green videoangiography and micro-Doppler, especially for the assessment of larger aneurysms. At the momentary state of this technology, it cannot replace postoperative conventional angiography. However, 3D fluoroscopy and image post-processing are young technologies. Further technical developments are likely to result in improved image quality.}, language = {en} } @article{vonBuerenOehlerShalabyetal.2011, author = {von Bueren, Andr{\´e} O. and Oehler, Christoph and Shalaby, Tarek and von Hoff, Katja and Pruschy, Martin and Seifert, Burkhardt and Gerber, Nicolas U. and Warmuth-Metz, Monika and Stearns, Duncan and Eberhart, Charles G. and Kortmann, Rolf D. and Rutkowski, Stefan and Grotzer, Michael A.}, title = {c-MYC expression sensitizes medulloblastoma cells to radio- and chemotherapy and has no impact on response in medulloblastoma patients}, series = {BMC Cancer}, volume = {11}, journal = {BMC Cancer}, number = {74}, doi = {10.1186/1471-2407-11-74}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-134185}, pages = {1-11}, year = {2011}, abstract = {Background: To study whether and how c-MYC expression determines response to radio-and chemotherapy in childhood medulloblastoma (MB). Methods: We used DAOY and UW228 human MB cells engineered to stably express different levels of c-MYC, and tested whether c-MYC expression has an effect on radio-and chemosensitivity using the colorimetric 3-(4,5-dimethylthiazol- 2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium inner salt (MTS) assay, clonogenic survival, apoptosis assays, cell cycle analysis, and western blot assessment. In an effort to validate our results, we analyzed c-MYC mRNA expression in formalin-fixed paraffin-embedded tumor samples from well-documented patients with postoperative residual tumor and compared c-MYC mRNA expression with response to radio-and chemotherapy as examined by neuroradiological imaging. Results: In DAOY -and to a lesser extent in UW228 -cells expressing high levels of c-MYC, the cytotoxicity of cisplatin, and etoposide was significantly higher when compared with DAOY/UW228 cells expressing low levels of c-MYC. Irradiation-and chemotherapy-induced apoptotic cell death was enhanced in DAOY cells expressing high levels of c-MYC. The response of 62 of 66 residual tumors was evaluable and response to postoperative radio-(14 responders (CR, PR) vs. 5 non-responders (SD, PD)) or chemotherapy (23 CR/PR vs. 20 SD/PD) was assessed. c-MYC mRNA expression was similar in primary MB samples of responders and non-responders (Mann-Whitney U test, p = 0.50, ratio 0.49, 95\% CI 0.008-30.0 and p = 0.67, ratio 1.8, 95\% CI 0.14-23.5, respectively). Conclusions: c-MYC sensitizes MB cells to some anti-cancer treatments in vitro. As we failed to show evidence for such an effect on postoperative residual tumors when analyzed by imaging, additional investigations in xenografts and larger MB cohorts may help to define the exact function of c-MYC in modulating response to treatment.}, language = {en} } @article{VogtKollikowskiWeidneretal.2022, author = {Vogt, Marius L. and Kollikowski, Alexander M. and Weidner, Franziska and Strinitz, Marc and Feick, J{\"o}rn and Essig, Fabian and Neugebauer, Herrmann and Haeusler, Karl Georg and Pham, Mirko and Maerz, Alexander}, title = {Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke}, series = {Clinical Neuroradiology}, volume = {32}, journal = {Clinical Neuroradiology}, number = {1}, doi = {10.1007/s00062-021-01122-1}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-264817}, pages = {141-151}, year = {2022}, abstract = {Background It is unknown whether technological advancement of stent-retriever devices influences typical observational indicators of safety or effectiveness. Methods Observational retrospective study of APERIO® (AP) vs. new generation APERIO® Hybrid (APH) (Acandis®, Pforzheim, Germany) stent-retriever device (01/2019-09/2020) for mechanical thrombectomy (MT) in large vessel occlusion (LVO) stroke. Primary effectiveness endpoint was successful recanalization eTICI (expanded Thrombolysis In Cerebral Ischemia) ≥ 2b67, primary safety endpoint was occurrence of hemorrhagic complications after MT. Secondary outcome measures were time from groin puncture to first pass and successful reperfusion, and the total number of passes needed to achieve the final recanalization result. Results A total of 298 patients with LVO stroke who were treated by MT matched the inclusion criteria: 148 patients (49.7\%) treated with AP vs. 150 patients (50.3\%) treated with new generation APH. Successful recanalization was not statistically different between both groups: 75.7\% for AP vs. 79.3\% for APH; p = 0.450. Postinterventional hemorrhagic complications and particularly subarachnoid hemorrhage as the entity possibly associated with stent-retriever device type was significantly less frequent in the group treated with the APH: 29.7\% for AP and 16.0\% for APH; p = 0.005; however, rates of symptomatic hemorrhage with clinical deterioration and in domo mortality were not statistically different. Neither the median number of stent-retriever passages needed to achieve final recanalization, time from groin puncture to first pass, time from groin puncture to final recanalization nor the number of cases in which successful recanalization could only be achieved by using a different stent-retriever as bail-out device differed between both groups. Conclusion In the specific example of the APERIO® stent-retriever device, we observed that further technological developments of the new generation device were not associated with disadvantages with respect to typical observational indicators of safety or effectiveness.}, language = {en} } @article{VogelRueckertFriedrichetal.2022, author = {Vogel, Patrick and R{\"u}ckert, Martin Andreas and Friedrich, Bernhard and Tietze, Rainer and Lyer, Stefan and Kampf, Thomas and Hennig, Thomas and D{\"o}lken, Lars and Alexiou, Christoph and Behr, Volker Christian}, title = {Critical Offset Magnetic PArticle SpectroScopy for rapid and highly sensitive medical point-of-care diagnostics}, series = {Nature Communications}, volume = {13}, journal = {Nature Communications}, doi = {10.1038/s41467-022-34941-y}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300893}, year = {2022}, abstract = {Magnetic nanoparticles (MNPs) have been adapted for many applications, e.g., bioassays for the detection of biomarkers such as antibodies, by controlled engineering of specific surface properties. Specific measurement of such binding states is of high interest but currently limited to highly sensitive techniques such as ELISA or flow cytometry, which are relatively inflexible, difficult to handle, expensive and time-consuming. Here we report a method named COMPASS (Critical-Offset-Magnetic-Particle-SpectroScopy), which is based on a critical offset magnetic field, enabling sensitive detection to minimal changes in mobility of MNP ensembles, e.g., resulting from SARS-CoV-2 antibodies binding to the S antigen on the surface of functionalized MNPs. With a sensitivity of 0.33 fmole/50 µl (≙7 pM) for SARS-CoV-2-S1 antibodies, measured with a low-cost portable COMPASS device, the proposed technique is competitive with respect to sensitivity while providing flexibility, robustness, and a measurement time of seconds per sample. In addition, initial results with blood serum demonstrate high specificity.}, language = {en} } @article{VogelRueckertGreineretal.2023, author = {Vogel, P. and R{\"u}ckert, M. A. and Greiner, C. and G{\"u}nther, J. and Reichl, T. and Kampf, T. and Bley, T. A. and Behr, V. C. and Herz, S.}, title = {iMPI: portable human-sized magnetic particle imaging scanner for real-time endovascular interventions}, series = {Scientific Reports}, volume = {13}, journal = {Scientific Reports}, doi = {10.1038/s41598-023-37351-2}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-357794}, year = {2023}, abstract = {Minimally invasive endovascular interventions have become an important tool for the treatment of cardiovascular diseases such as ischemic heart disease, peripheral artery disease, and stroke. X-ray fluoroscopy and digital subtraction angiography are used to precisely guide these procedures, but they are associated with radiation exposure for patients and clinical staff. Magnetic Particle Imaging (MPI) is an emerging imaging technology using time-varying magnetic fields combined with magnetic nanoparticle tracers for fast and highly sensitive imaging. In recent years, basic experiments have shown that MPI has great potential for cardiovascular applications. However, commercially available MPI scanners were too large and expensive and had a small field of view (FOV) designed for rodents, which limited further translational research. The first human-sized MPI scanner designed specifically for brain imaging showed promising results but had limitations in gradient strength, acquisition time and portability. Here, we present a portable interventional MPI (iMPI) system dedicated for real-time endovascular interventions free of ionizing radiation. It uses a novel field generator approach with a very large FOV and an application-oriented open design enabling hybrid approaches with conventional X-ray-based angiography. The feasibility of a real-time iMPI-guided percutaneous transluminal angioplasty (PTA) is shown in a realistic dynamic human-sized leg model.}, language = {en} } @article{TraubOttoSelletal.2022, author = {Traub, Jan and Otto, Markus and Sell, Roxane and Homola, Gy{\"o}rgy A. and Steinacker, Petra and Oeckl, Patrick and Morbach, Caroline and Frantz, Stefan and Pham, Mirko and St{\"o}rk, Stefan and Stoll, Guido and Frey, Anna}, title = {Serum glial fibrillary acidic protein indicates memory impairment in patients with chronic heart failure}, series = {ESC Heart Failure}, volume = {9}, journal = {ESC Heart Failure}, number = {4}, doi = {10.1002/ehf2.13986}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-312736}, pages = {2626-2634}, year = {2022}, abstract = {Aims Cognitive dysfunction occurs frequently in patients with heart failure (HF), but early detection remains challenging. Serum glial fibrillary acidic protein (GFAP) is an emerging biomarker of cognitive decline in disorders of primary neurodegeneration such as Alzheimer's disease. We evaluated the utility of serum GFAP as a biomarker for cognitive dysfunction and structural brain damage in patients with stable chronic HF. Methods and results Using bead-based single molecule immunoassays, we quantified serum levels of GFAP in patients with HF participating in the prospective Cognition.Matters-HF study. Participants were extensively phenotyped, including cognitive testing of five separate domains and magnetic resonance imaging (MRI) of the brain. Univariable and multivariable models, also accounting for multiple testing, were run. One hundred and forty-six chronic HF patients with a mean age of 63.8 ± 10.8 years were included (15.1\% women). Serum GFAP levels (median 246 pg/mL, quartiles 165, 384 pg/mL; range 66 to 1512 pg/mL) did not differ between sexes. In the multivariable adjusted model, independent predictors of GFAP levels were age (T = 5.5; P < 0.001), smoking (T = 3.2; P = 0.002), estimated glomerular filtration rate (T = -4.7; P < 0.001), alanine aminotransferase (T = -2.1; P = 0.036), and the left atrial end-systolic volume index (T = 3.4; P = 0.004). NT-proBNP but not serum GFAP explained global cerebral atrophy beyond ageing. However, serum GFAP levels were associated with the cognitive domain visual/verbal memory (T = -3.0; P = 0.003) along with focal hippocampal atrophy (T = 2.3; P = 0.025). Conclusions Serum GFAP levels are affected by age, smoking, and surrogates of the severity of HF. The association of GFAP with memory dysfunction suggests that astroglial pathologies, which evade detection by conventional MRI, may contribute to memory loss beyond ageing in patients with chronic HF.}, language = {en} } @article{TraubOttoSelletal.2022, author = {Traub, Jan and Otto, Markus and Sell, Roxane and G{\"o}pfert, Dennis and Homola, Gy{\"o}rgy and Steinacker, Petra and Oeckl, Patrick and Morbach, Caroline and Frantz, Stefan and Pham, Mirko and St{\"o}rk, Stefan and Stoll, Guido and Frey, Anna}, title = {Serum phosphorylated tau protein 181 and neurofilament light chain in cognitively impaired heart failure patients}, series = {Alzheimer's Research \& Therapy}, volume = {14}, journal = {Alzheimer's Research \& Therapy}, doi = {10.1186/s13195-022-01087-4}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300515}, year = {2022}, abstract = {Background Chronic heart failure (HF) is known to increase the risk of developing Alzheimer's dementia significantly. Thus, detecting and preventing mild cognitive impairment, which is common in patients with HF, is of great importance. Serum biomarkers are increasingly used in neurological disorders for diagnostics, monitoring, and prognostication of disease course. It remains unclear if neuronal biomarkers may help detect cognitive impairment in this high-risk population. Also, the influence of chronic HF and concomitant renal dysfunction on these biomarkers is not well understood. Methods Within the monocentric Cognition.Matters-HF study, we quantified the serum levels of phosphorylated tau protein 181 (pTau) and neurofilament light chain (NfL) of 146 extensively phenotyped chronic heart failure patients (aged 32 to 85 years; 15.1\% women) using ultrasensitive bead-based single-molecule immunoassays. The clinical work-up included advanced cognitive testing and cerebral magnetic resonance imaging (MRI). Results Serum concentrations of NfL ranged from 5.4 to 215.0 pg/ml (median 26.4 pg/ml) and of pTau from 0.51 to 9.22 pg/ml (median 1.57 pg/ml). We detected mild cognitive impairment (i.e., T-score < 40 in at least one cognitive domain) in 60\% of heart failure patients. pTau (p = 0.014), but not NfL, was elevated in this group. Both NfL (ρ = - 0.21; p = 0.013) and pTau (ρ = - 0.25; p = 0.002) related to the cognitive domain visual/verbal memory, as well as white matter hyperintensity volume and cerebral and hippocampal atrophy. In multivariable analysis, both biomarkers were independently influenced by age (T = 4.6 for pTau; T = 5.9 for NfL) and glomerular filtration rate (T = - 2.4 for pTau; T = - 3.4 for NfL). Markers of chronic heart failure, left atrial volume index (T = 4.6) and NT-proBNP (T = 2.8), were further cardiological determinants of pTau and NfL, respectively. In addition, pTau was also strongly affected by serum creatine kinase levels (T = 6.5) and ferritin (T = - 3.1). Conclusions pTau and NfL serum levels are strongly influenced by age-dependent renal and cardiac dysfunction. These findings point towards the need for longitudinal examinations and consideration of frequent comorbidities when using neuronal serum biomarkers.}, language = {en} } @article{TaegerMuellerGraffNeunetal.2021, author = {Taeger, Johannes and M{\"u}ller-Graff, Franz-Tassilo and Neun, Tilmann and K{\"o}ping, Maria and Schendzielorz, Philipp and Hagen, Rudolf and Rak, Kristen}, title = {Highly precise navigation at the lateral skull base by the combination of flat-panel volume CT and electromagnetic navigation}, series = {Science Progress}, volume = {104}, journal = {Science Progress}, number = {3}, issn = {2047-7163}, doi = {10.1177/00368504211032090}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-250268}, year = {2021}, abstract = {This study aimed to evaluate the feasibility and accuracy of electromagnetic navigation at the lateral skull base in combination with flat panel volume computed tomography (fpVCT) datasets. A mastoidectomy and a posterior tympanotomy were performed on 10 samples of fresh frozen temporal bones. For registration, four self-drilling titanium screws were applied as fiducial markers. Multi-slice computed tomography (MSCT; 600 µm), conventional flat panel volume computed tomography (fpVCT; 466 µm), micro-fpVCT (197 µm) and secondary reconstructed fpVCT (100 µM) scans were performed and data were loaded into the navigation system. The resulting fiducial registration error (FRE) was analysed, and control of the navigation accuracy was performed. The registration process was very quick and reliable with the screws as fiducials. Compared to using the MSCT data, the micro-fpVCT data led to significantly lower FRE values, whereas conventional fpVCT and secondary reconstructed fpVCT data had no advantage in terms of accuracy. For all imaging modalities, there was no relevant visual deviation when targeting defined anatomical points with a navigation probe. fpVCT data are very well suited for electromagnetic navigation at the lateral skull base. The use of titanium screws as fiducial markers turned out to be ideal for comparing different imaging methods. A further evaluation of this approach by a clinical trial is required.}, language = {en} }