@article{WernerBeykanHiguchietal.2016, author = {Werner, Rudolf A. and Beykan, Seval and Higuchi, Takahiro and L{\"u}ckerath, Katharina and Weich, Alexander and Scheurlen, Michael and Bluemel, Christina and Herrmann, Ken and Buck, Andreas K. and Lassmann, Michael and Lapa, Constantin and H{\"a}nscheid, Heribert}, title = {The impact of \(^{177}\)Lu-octreotide therapy on \(^{99m}\)Tc-MAG3 clearance is not predictive for late nephropathy}, series = {Oncotarget}, volume = {7}, journal = {Oncotarget}, number = {27}, doi = {10.18632/oncotarget.9775}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-177318}, pages = {41233-41241}, year = {2016}, abstract = {Peptide Receptor Radionuclide Therapy (PRRT) for the treatment of neuroendocrine tumors may lead to kidney deterioration. This study aimed to evaluate the suitability of \(^{99m}\)Tc-mercaptoacetyltriglycine (\(^{99m}\)Tc-MAG3) clearance for the early detection of PRRT-induced changes on tubular extraction (TE). TE rate (TER) was measured prior to 128 PRRT cycles (7.6±0.4 GBq \(^{177}\)Lu-octreotate/octreotide each) in 32 patients. TER reduction during PRRT was corrected for age-related decrease and analyzed for the potential to predict loss of glomerular filtration (GF). The GF rate (GFR) as measure for renal function was derived from serum creatinine. The mean TER was 234 ± 53 ml/min/1.73 m² before PRRT (baseline) and 221 ± 45 ml/min/1.73 m² after a median follow-up of 370 days. The age-corrected decrease (mean: -3\%, range: -27\% to +19\%) did not reach significance (p=0.09) but significantly correlated with the baseline TER (Spearman p=-0.62, p<0.001). Patients with low baseline TER showed an improved TER after PRRT, high decreases were only observed in individuals with high baseline TER. Pre-therapeutic TER data were inferior to plasma creatinine-derived GFR estimates in predicting late nephropathy. TER assessed by \(^{99m}\)Tc-MAG3­clearance prior to and during PRRT is not suitable as early predictor of renal injury and an increased risk for late nephropathy.}, language = {en} } @article{DicksonEberleinLassmann2022, author = {Dickson, John and Eberlein, Uta and Lassmann, Michael}, title = {The effect of modern PET technology and techniques on the EANM paediatric dosage card}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {49}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {6}, issn = {1619-7089}, doi = {10.1007/s00259-021-05635-2}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-265624}, pages = {1964-1969}, year = {2022}, abstract = {Aim Recent advancements in PET technology have brought with it significant improvements in PET performance and image quality. In particular, the extension of the axial field of view of PET systems, and the introduction of semiconductor technology into the PET detector, initially for PET/MR, and more recently available long-field-of-view PET/CT systems (≥ 25 cm) have brought a step change improvement in the sensitivity of PET scanners. Given the requirement to limit paediatric doses, this increase in sensitivity is extremely welcome for the imaging of children and young people. This is even more relevant with PET/MR, where the lack of CT exposures brings further dose reduction benefits to this population. In this short article, we give some details around the benefits around new PET technology including PET/MR and its implications on the EANM paediatric dosage card. Material and methods Reflecting on EANM adult guidance on injected activities, and making reference to bed overlap and the concept of MBq.min bed\(^{-1}\) kg\(^{-1}\), we use published data on image quality from PET/MR systems to update the paediatric dosage card for PET/MR and extended axial field of view (≥ 25 cm) PET/CT systems. However, this communication does not cover the expansion of paediatric dosing for the half-body and total-body scanners that have recently come to market. Results In analogy to the existing EANM dosage card, new parameters for the EANM paediatric dosage card were developed (class B, baseline value: 10.7 MBq, minimum recommended activity 10 MBq). The recommended administered activities for the systems considered in this communication range from 11 MBq [\(^{18}\)F]FDG for a child with a weight of 3 kg to 149 MBq [\(^{18}\)F]FDG for a paediatric patient weight of 68 kg, assuming a scan of 3 min per bed position. The mean effective dose over all ages (1 year and older) is 2.85 mSv. Conclusion With this, recommendations for paediatric dosing are given for systems that have not been considered previously.}, language = {en} } @article{GoeringSchumannMuelleretal.2022, author = {G{\"o}ring, Lukas and Schumann, Sarah and M{\"u}ller, Jessica and Buck, Andreas K. and Port, Matthias and Lassmann, Michael and Scherthan, Harry and Eberlein, Uta}, title = {Repair of a-particle-induced DNA damage in peripheral blood mononuclear cells after internal ex vivo irradiation with \(^{223}\)Ra}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {49}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {12}, doi = {10.1007/s00259-022-05860-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324557}, pages = {3981-3988}, year = {2022}, abstract = {Purpose As α-emitters for radiopharmaceutical therapies are administered systemically by intravenous injection, blood will be irradiated by α-particles that induce clustered DNA double-strand breaks (DSBs). Here, we investigated the induction and repair of DSB damage in peripheral blood mononuclear cells (PBMCs) as a function of the absorbed dose to the blood following internal ex vivo irradiation with [\(^{223}\)Ra]RaCl2. Methods Blood samples of ten volunteers were irradiated by adding [\(^{223}\)Ra]RaCl2 solution with different activity concentrations resulting in absorbed doses to the blood of 3 mGy, 25 mGy, 50 mGy and 100 mGy. PBMCs were isolated, divided in three parts and either fixed directly (d-samples) or after 4 h or 24 h culture. After immunostaining, the induced γ-H2AX α-tracks were counted. The time-dependent decrease in α-track frequency was described with a model assuming a repair rate R and a fraction of non-repairable damage Q. Results For 25 mGy, 50 mGy and 100 mGy, the numbers of α-tracks were significantly increased compared to baseline at all time points. Compared to the corresponding d-samples, the α-track frequency decreased significantly after 4 h and after 24 h. The repair rates R were (0.24 ± 0.05) h-1 for 25 mGy, (0.16 ± 0.04) h-1 for 50 mGy and (0.13 ± 0.02) h-1 for 100 mGy, suggesting faster repair at lower absorbed doses, while Q-values were similar. Conclusion The results obtained suggest that induction and repair of the DSB damage depend on the absorbed dose to the blood. Repair rates were similar to what has been observed for irradiation with low linear energy transfer.}, language = {en} } @article{TranGiaDenisBacelarFerreiraetal.2023, author = {Tran-Gia, Johannes and Denis-Bacelar, Ana M. and Ferreira, Kelley M. and Robinson, Andrew P. and Bobin, Christophe and Bonney, Lara M. and Calvert, Nicholas and Collins, Sean M. and Fenwick, Andrew J. and Finocchiaro, Domenico and Fioroni, Federica and Giannopoulou, Katerina and Grassi, Elisa and Heetun, Warda and Jewitt, Stephanie J. and Kotzasarlidou, Maria and Ljungberg, Michael and Louren{\c{c}}o, Val{\´e}rie and McGowan, Daniel R. and Mewburn-Crook, Jamie and Sabot, Benoit and Scuffham, James and Sj{\"o}green Gleisner, Katarina and Solc, Jaroslav and Thiam, Cheick and Tipping, Jill and Wevrett, Jill and Lassmann, Michael}, title = {On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT/CT calibration: a European multi-centre evaluation}, series = {EJNMMI Physics}, volume = {10}, journal = {EJNMMI Physics}, organization = {The MRT Dosimetry Collaboration}, doi = {10.1186/s40658-023-00582-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-357740}, year = {2023}, abstract = {Introduction Commissioning, calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple sources of uncertainty, many of which can be overcome by using traceable, sealed, long-lived surrogate sources containing a radionuclide of comparable energies and emission probabilities. This study presents the results of a quantitative SPECT/CT imaging comparison exercise performed within the MRTDosimetry consortium to assess the feasibility of using 133Ba as a surrogate for 131I imaging. Materials and methods Two sets of four traceable 133Ba sources were produced at two National Metrology Institutes and encapsulated in 3D-printed cylinders (volume range 1.68-107.4 mL). Corresponding hollow cylinders to be filled with liquid 131I and a mounting baseplate for repeatable positioning within a Jaszczak phantom were also produced. A quantitative SPECT/CT imaging comparison exercise was conducted between seven members of the consortium (eight SPECT/CT systems from two major vendors) based on a standardised protocol. Each site had to perform three measurements with the two sets of 133Ba sources and liquid 131I. Results As anticipated, the 131I pseudo-image calibration factors (cps/MBq) were higher than those for 133Ba for all reconstructions and systems. A site-specific cross-calibration reduced the performance differences between both radionuclides with respect to a cross-calibration based on the ratio of emission probabilities from a median of 12-1.5\%. The site-specific cross-calibration method also showed agreement between 133Ba and 131I for all cylinder volumes, which highlights the potential use of 133Ba sources to calculate recovery coefficients for partial volume correction. Conclusion This comparison exercise demonstrated that traceable solid 133Ba sources can be used as surrogate for liquid 131I imaging. The use of solid surrogate sources could solve the radiation protection problem inherent in the preparation of phantoms with 131I liquid activity solutions as well as reduce the measurement uncertainties in the activity. This is particularly relevant for stability measurements, which have to be carried out at regular intervals.}, language = {en} } @article{IsaiasSpiegelBrumbergetal.2014, author = {Isaias, Ioannis Ugo and Spiegel, J{\"o}rg and Brumberg, Joachim and Cosgrove, Kelly P. and Marotta, Giorgio and Oishi, Naoya and Higuchi, Takahiro and K{\"u}sters, Sebastian and Schiller, Markus and Dillmann, Ulrich and van Dyck, Christopher H. and Buck, Andreas and Herrmann, Ken and Schloegl, Susanne and Volkmann, Jens and Lassmann, Michael and Fassbender, Klaus and Lorenz, Reinhard and Samnick, Samuel}, title = {Nicotinic acetylcholine receptor density in cognitively intact subjects at an early stage of Parkinson's disease}, series = {Frontiers in Aging Neuroscience}, volume = {6}, journal = {Frontiers in Aging Neuroscience}, doi = {10.3389/fnagi.2014.00213}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-119351}, pages = {213}, year = {2014}, abstract = {We investigated in vivo brain nicotinic acetylcholine receptor (nAChR) distribution in cognitively intact subjects with Parkinson's disease (PD) at an early stage of the disease. Fourteen patients and 13 healthy subjects were imaged with single photon emission computed tomography and the radiotracer 5-[(123)I]iodo-3-[2(S)-2-azetidinylmethoxy]pyridine ([(123)I]5IA). Patients were selected according to several criteria, including short duration of motor signs (<7 years) and normal scores at an extensive neuropsychological evaluation. In PD patients, nAChR density was significantly higher in the putamen, the insular cortex and the supplementary motor area and lower in the caudate nucleus, the orbitofrontal cortex, and the middle temporal gyrus. Disease duration positively correlated with nAChR density in the putamen ipsilateral (ρ = 0.56, p < 0.05) but not contralateral (ρ = 0.49, p = 0.07) to the clinically most affected hemibody. We observed, for the first time in vivo, higher nAChR density in brain regions of the motor and limbic basal ganglia circuits of subjects with PD. Our findings support the notion of an up-regulated cholinergic activity at the striatal and possibly cortical level in cognitively intact PD patients at an early stage of disease.}, language = {en} } @article{ScherthanLeeMausetal.2019, author = {Scherthan, Harry and Lee, Jin-Ho and Maus, Emanuel and Schumann, Sarah and Muhtadi, Razan and Chojowski, Robert and Port, Matthias and Lassmann, Michael and Bestvater, Felix and Hausmann, Michael}, title = {Nanostructure of clustered DNA damage in leukocytes after in-solution irradiation with the alpha emitter Ra-223}, series = {Cancers}, volume = {11}, journal = {Cancers}, number = {12}, issn = {2072-6694}, doi = {10.3390/cancers11121877}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-193038}, year = {2019}, abstract = {Background: Cancer patients are increasingly treated with alpha-particle-emitting radiopharmaceuticals. At the subcellular level, alpha particles induce densely spaced ionizations and molecular damage. Induction of DNA lesions, especially clustered DNA double-strand breaks (DSBs), threatens a cell's survival. Currently, it is under debate to what extent the spatial topology of the damaged chromatin regions and the repair protein arrangements are contributing. Methods: Super-resolution light microscopy (SMLM) in combination with cluster analysis of single molecule signal-point density regions of DSB repair markers was applied to investigate the nano-structure of DNA damage foci tracks of Ra-223 in-solution irradiated leukocytes. Results: Alpha-damaged chromatin tracks were efficiently outlined by γ-H2AX that formed large (super) foci composed of numerous 60-80 nm-sized nano-foci. Alpha damage tracks contained 60-70\% of all γ-H2AX point signals in a nucleus, while less than 30\% of 53BP1, MRE11 or p-ATM signals were located inside γ-H2AX damage tracks. MRE11 and p-ATM protein fluorescent tags formed focal nano-clusters of about 20 nm peak size. There were, on average, 12 (±9) MRE11 nanoclusters in a typical γ-H2AX-marked alpha track, suggesting a minimal number of MRE11-processed DSBs per track. Our SMLM data suggest regularly arranged nano-structures during DNA repair in the damaged chromatin domain.}, language = {en} } @inproceedings{WernerLapaBucketal.2017, author = {Werner, Rudolf and Lapa, Constantin and Buck, Andreas and Lassmann, Michael and H{\"a}nscheid, Heribert}, title = {Less is sometimes more - Accurate Dose Mapping after Endoradiotherapy with \(^{177}\)Lu-DOTATATE/-TOC by One-Single Measurement after 96 h}, series = {Journal of Nuclear Medicine}, volume = {58}, booktitle = {Journal of Nuclear Medicine}, number = {No. Supplement 1}, publisher = {Society of Nuclear Medicine and Molecular Imaging}, issn = {0161-5505}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-161168}, pages = {247}, year = {2017}, abstract = {No abstract available.}, language = {en} } @article{LassmannPreylowskiSchloegletal.2013, author = {Lassmann, Michael and Preylowski, Veronika and Schl{\"o}gl, Susanne and Schoenahl, Fr{\´e}d{\´e}ric and J{\"o}rg, Gerhard and Samnick, Samuel and Buck, Andreas K.}, title = {Is the Image Quality of I-124-PET Impaired by an Automatic Correction of Prompt Gammas?}, series = {PLoS ONE}, journal = {PLoS ONE}, doi = {10.1371/journal.pone.0071729}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-96863}, year = {2013}, abstract = {Objectives The aim of this study is to evaluate the quality of I-124 PET images with and without prompt gamma compensation (PGC) by comparing the recovery coefficients (RC), the signal to noise ratios (SNR) and the contrast to F-18 and Ga-68. Furthermore, the influence of the PGC on the quantification and image quality is evaluated. Methods For measuring the image quality the NEMA NU2-2001 PET/SPECT-Phantom was used containing 6 spheres with a diameter between 10 mm and 37 mm placed in water with different levels of background activity. Each sphere was filled with the same activity concentration measured by an independently cross-calibrated dose calibrator. The "hot" sources were acquired with a full 3D PET/CT (Biograph mCT®, Siemens Medical USA). Acquisition times were 2 min for F-18 and Ga-68, and 10 min for I-124. For reconstruction an OSEM algorithm was applied. For I-124 the images were reconstructed with and without PGC. For the calculation of the RCs the activity concentrations in each sphere were determined; in addition, the influence of the background correction was studied. Results The RCs of Ga-68 are the smallest (79\%). I-124 reaches similar RCs (87\% with PGC, 84\% without PGC) as F-18 (84\%). showing that the quantification of I-124 images is similar to F-18 and slightly better than Ga-68. With background activity the contrast of the I-124 PGC images is similar to Ga-68 and F-18 scans. There was lower background activity in the I-124 images without PGC, which probably originates from an overcorrection of the scatter contribution. Consequently, the contrast without PGC was much higher than with PGC. As a consequence PGC should be used for I-124. Conclusions For I-124 there is only a slight influence on the quantification depending on the use of the PGC. However, there are considerable differences with respect to I-124 image quality.}, language = {en} } @article{WevrettFenwickScuffhametal.2018, author = {Wevrett, Jill and Fenwick, Andrew and Scuffham, James and Johansson, Lena and Gear, Jonathan and Schl{\"o}gl, Susanne and Segbers, Marcel and Sj{\"o}green-Gleisner, Katarina and Soln{\´y}, Pavel and Lassmann, Michael and Tipping, Jill and Nisbet, Andrew}, title = {Inter-comparison of quantitative imaging of lutetium-177 (\(^{177}\)Lu) in European hospitals}, series = {EJNMMI Physics}, volume = {5}, journal = {EJNMMI Physics}, doi = {10.1186/s40658-018-0213-z}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-233658}, year = {2018}, abstract = {Background This inter-comparison exercise was performed to demonstrate the variability of quantitative SPECT/CT imaging for lutetium-177 (\(^{177}\)Lu) in current clinical practice. Our aim was to assess the feasibility of using international inter-comparison exercises as a means to ensure consistency between clinical sites whilst enabling the sites to use their own choice of quantitative imaging protocols, specific to their systems. Dual-compartment concentric spherical sources of accurately known activity concentrations were prepared and sent to seven European clinical sites. The site staff were not aware of the true volumes or activity within the sources—they performed SPECT/CT imaging of the source, positioned within a water-filled phantom, using their own choice of parameters and reported their estimate of the activities within the source. Results The volumes reported by the participants for the inner section of the source were all within 29\% of the true value and within 60\% of the true value for the outer section. The activities reported by the participants for the inner section of the source were all within 20\% of the true value, whilst those reported for the outer section were up to 83\% different to the true value. Conclusions A variety of calibration and segmentation methods were used by the participants for this exercise which demonstrated the variability of quantitative imaging across clinical sites. This paper presents a method to assess consistency between sites using different calibration and segmentation methods.}, language = {en} } @article{BeykanFaniJensenetal.2019, author = {Beykan, Seval and Fani, Melpomeni and Jensen, Svend Borup and Nicolas, Guillaume and Wild, Damian and Kaufmann, Jens and Lassmann, Michael}, title = {In vivo biokinetics of \(^{177}\)Lu-OPS201 in Mice and Pigs as a Model for Predicting Human Dosimetry}, series = {Contrast Media \& Molecular Imaging}, volume = {2019}, journal = {Contrast Media \& Molecular Imaging}, doi = {10.1155/2019/6438196}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-177382}, pages = {6438196}, year = {2019}, abstract = {Introduction. \(^{177}\)Lu-OPS201 is a high-affinity somatostatin receptor subtype 2 antagonist for PRRT in patients with neuroendocrine tumors. The aim is to find the optimal scaling for dosimetry and to compare the biokinetics of \(^{177}\)Lu-OPS201 in animals and humans. Methods. Data on biokinetics of \(^{177}\)Lu-OPS201 were analyzed in athymic nude Foxn1\(^{nu}\) mice (28 F, weight: 26 ± 1 g), Danish Landrace pigs (3 F-1 M, weight: 28 ± 2 kg), and patients (3 F-1 M, weight: 61 ± 17 kg) with administered activities of 0.19-0.27 MBq (mice), 97-113 MBq (pigs), and 850-1086 MBq (patients). After euthanizing mice (up to 168 h), the organ-specific activity contents (including blood) were measured. Multiple planar and SPECT/CT scans were performed until 250 h (pigs) and 72 h (patients) to quantify the uptake in the kidneys and liver. Blood samples were taken up to 23 h (patients) and 300 h (pigs). In pigs and patients, kidney protection was applied. Time-dependent uptake data sets were created for each species and organ/tissue. Biexponential fits were applied to compare the biokinetics in the kidneys, liver, and blood of each species. The time-integrated activity coefficients (TIACs) were calculated by using NUKFIT. To determine the optimal scaling, several methods (relative mass scaling, time scaling, combined mass and time scaling, and allometric scaling) were compared. Results. A fast blood clearance of the compound was observed in the first phase (<56 h) for all species. In comparison with patients, pigs showed higher liver retention. Based on the direct comparison of the TIACs, an underestimation in mice (liver and kidneys) and an overestimation in pigs' kidneys compared to the patient data (kidney TIAC: mice = 1.4 h, pigs = 7.7 h, and patients = 5.8 h; liver TIAC: mice = 0.7 h, pigs = 4.1 h, and patients = 5.3 h) were observed. Most similar TIACs were obtained by applying time scaling (mice) and combined scaling (pigs) (kidney TIAC: mice = 3.9 h, pigs = 4.8 h, and patients = 5.8 h; liver TIAC: mice = 0.9 h, pigs = 4.7 h, and patients = 5.3 h). Conclusion. If the organ mass ratios between the species are high, the combined mass and time scaling method is optimal to minimize the interspecies differences. The analysis of the fit functions and the TIACs shows that pigs are better mimicking human biokinetics.}, language = {en} }