@article{HaarmannVollmuthKollikowskietal.2023, author = {Haarmann, Axel and Vollmuth, Christoph and Kollikowski, Alexander M. and Heuschmann, Peter U. and Pham, Mirko and Stoll, Guido and Neugebauer, Hermann and Schuhmann, Michael K.}, title = {Vasoactive soluble endoglin: a novel biomarker indicative of reperfusion after cerebral large-vessel occlusion}, series = {Cells}, volume = {12}, journal = {Cells}, number = {2}, issn = {2073-4409}, doi = {10.3390/cells12020288}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-304995}, year = {2023}, abstract = {Now that mechanical thrombectomy has substantially improved outcomes after large-vessel occlusion stroke in up to every second patient, futile reperfusion wherein successful recanalization is not followed by a favorable outcome is moving into focus. Unfortunately, blood-based biomarkers, which identify critical stages of hemodynamically compromised yet reperfused tissue, are lacking. We recently reported that hypoxia induces the expression of endoglin, a TGF-β co-receptor, in human brain endothelium in vitro. Subsequent reoxygenation resulted in shedding. Our cell model suggests that soluble endoglin compromises the brain endothelial barrier function. To evaluate soluble endoglin as a potential biomarker of reperfusion (-injury) we analyzed its concentration in 148 blood samples of patients with acute stroke due to large-vessel occlusion. In line with our in vitro data, systemic soluble endoglin concentrations were significantly higher in patients with successful recanalization, whereas hypoxia alone did not induce local endoglin shedding, as analyzed by intra-arterial samples from hypoxic vasculature. In patients with reperfusion, higher concentrations of soluble endoglin additionally indicated larger infarct volumes at admission. In summary, we give translational evidence that the sequence of hypoxia and subsequent reoxygenation triggers the release of vasoactive soluble endoglin in large-vessel occlusion stroke and can serve as a biomarker for severe ischemia with ensuing recanalization/reperfusion.}, language = {en} } @article{GuggenbergerVogtSongetal.2023, author = {Guggenberger, Konstanze V. and Vogt, Marius L. and Song, Jae W. and Weng, Andreas M. and Fr{\"o}hlich, Matthias and Schmalzing, Marc and Venhoff, Nils and Hillenkamp, Jost and Pham, Mirko and Meckel, Stephan and Bley, Thorsten A.}, title = {Intraorbital findings in giant cell arteritis on black blood MRI}, series = {European Radiology}, volume = {33}, journal = {European Radiology}, number = {4}, doi = {10.1007/s00330-022-09256-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324978}, pages = {2529-2535}, year = {2023}, abstract = {Objective Blindness is a feared complication of giant cell arteritis (GCA). However, the spectrum of pathologic orbital imaging findings on magnetic resonance imaging (MRI) in GCA is not well understood. In this study, we assess inflammatory changes of intraorbital structures on black blood MRI (BB-MRI) in patients with GCA compared to age-matched controls. Methods In this multicenter case-control study, 106 subjects underwent BB-MRI. Fifty-six patients with clinically or histologically diagnosed GCA and 50 age-matched controls without clinical or laboratory evidence of vasculitis were included. All individuals were imaged on a 3-T MR scanner with a post-contrast compressed-sensing (CS) T1-weighted sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) BB-MRI sequence. Imaging results were correlated with available clinical symptoms. Results Eighteen of 56 GCA patients (32\%) showed inflammatory changes of at least one of the intraorbital structures. The most common finding was enhancement of at least one of the optic nerve sheaths (N = 13, 72\%). Vessel wall enhancement of the ophthalmic artery was unilateral in 8 and bilateral in 3 patients. Enhancement of the optic nerve was observed in one patient. There was no significant correlation between imaging features of inflammation and clinically reported orbital symptoms (p = 0.10). None of the age-matched control patients showed any inflammatory changes of intraorbital structures. Conclusions BB-MRI revealed inflammatory findings in the orbits in up to 32\% of patients with GCA. Optic nerve sheath enhancement was the most common intraorbital inflammatory change on BB-MRI. MRI findings were independent of clinically reported orbital symptoms. Key Points • Up to 32\% of GCA patients shows signs of inflammation of intraorbital structures on BB-MRI. • Enhancement of the optic nerve sheath is the most common intraorbital finding in GCA patients on BB-MRI. • Features of inflammation of intraorbital structures are independent of clinically reported symptoms.}, language = {en} } @article{StebaniBlaimerZableretal.2023, author = {Stebani, Jannik and Blaimer, Martin and Zabler, Simon and Neun, Tilmann and Pelt, Dani{\"e}l M. and Rak, Kristen}, title = {Towards fully automated inner ear analysis with deep-learning-based joint segmentation and landmark detection framework}, series = {Scientific Reports}, volume = {13}, journal = {Scientific Reports}, doi = {10.1038/s41598-023-45466-9}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-357411}, year = {2023}, abstract = {Automated analysis of the inner ear anatomy in radiological data instead of time-consuming manual assessment is a worthwhile goal that could facilitate preoperative planning and clinical research. We propose a framework encompassing joint semantic segmentation of the inner ear and anatomical landmark detection of helicotrema, oval and round window. A fully automated pipeline with a single, dual-headed volumetric 3D U-Net was implemented, trained and evaluated using manually labeled in-house datasets from cadaveric specimen (N = 43) and clinical practice (N = 9). The model robustness was further evaluated on three independent open-source datasets (N = 23 + 7 + 17 scans) consisting of cadaveric specimen scans. For the in-house datasets, Dice scores of 0.97 and 0.94, intersection-over-union scores of 0.94 and 0.89 and average Hausdorf distances of 0.065 and 0.14 voxel units were achieved. The landmark localization task was performed automatically with an average localization error of 3.3 and 5.2 voxel units. A robust, albeit reduced performance could be attained for the catalogue of three open-source datasets. Results of the ablation studies with 43 mono-parametric variations of the basal architecture and training protocol provided task-optimal parameters for both categories. Ablation studies against single-task variants of the basal architecture showed a clear performance beneft of coupling landmark localization with segmentation and a dataset-dependent performance impact on segmentation ability.}, language = {en} } @article{VogelRueckertGreineretal.2023, author = {Vogel, P. and R{\"u}ckert, M. A. and Greiner, C. and G{\"u}nther, J. and Reichl, T. and Kampf, T. and Bley, T. A. and Behr, V. C. and Herz, S.}, title = {iMPI: portable human-sized magnetic particle imaging scanner for real-time endovascular interventions}, series = {Scientific Reports}, volume = {13}, journal = {Scientific Reports}, doi = {10.1038/s41598-023-37351-2}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-357794}, year = {2023}, abstract = {Minimally invasive endovascular interventions have become an important tool for the treatment of cardiovascular diseases such as ischemic heart disease, peripheral artery disease, and stroke. X-ray fluoroscopy and digital subtraction angiography are used to precisely guide these procedures, but they are associated with radiation exposure for patients and clinical staff. Magnetic Particle Imaging (MPI) is an emerging imaging technology using time-varying magnetic fields combined with magnetic nanoparticle tracers for fast and highly sensitive imaging. In recent years, basic experiments have shown that MPI has great potential for cardiovascular applications. However, commercially available MPI scanners were too large and expensive and had a small field of view (FOV) designed for rodents, which limited further translational research. The first human-sized MPI scanner designed specifically for brain imaging showed promising results but had limitations in gradient strength, acquisition time and portability. Here, we present a portable interventional MPI (iMPI) system dedicated for real-time endovascular interventions free of ionizing radiation. It uses a novel field generator approach with a very large FOV and an application-oriented open design enabling hybrid approaches with conventional X-ray-based angiography. The feasibility of a real-time iMPI-guided percutaneous transluminal angioplasty (PTA) is shown in a realistic dynamic human-sized leg model.}, language = {en} } @article{GuggenbergerBleyVogtetal.2022, author = {Guggenberger, Konstanze V. and Bley, Thorsten A. and Vogt, Marius L. and Urbach, Horst and Meckel, Stephan}, title = {High-Resolution Black Blood Vessel Wall Imaging in COVID-19 Encephalopathy-Is it Really Endotheliitis?}, series = {Clinical Neuroradiology}, volume = {32}, journal = {Clinical Neuroradiology}, number = {1}, doi = {10.1007/s00062-021-01109-y}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-264794}, pages = {295-296}, year = {2022}, abstract = {No abstract available.}, language = {en} } @article{VogtKollikowskiWeidneretal.2022, author = {Vogt, Marius L. and Kollikowski, Alexander M. and Weidner, Franziska and Strinitz, Marc and Feick, J{\"o}rn and Essig, Fabian and Neugebauer, Herrmann and Haeusler, Karl Georg and Pham, Mirko and Maerz, Alexander}, title = {Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke}, series = {Clinical Neuroradiology}, volume = {32}, journal = {Clinical Neuroradiology}, number = {1}, doi = {10.1007/s00062-021-01122-1}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-264817}, pages = {141-151}, year = {2022}, abstract = {Background It is unknown whether technological advancement of stent-retriever devices influences typical observational indicators of safety or effectiveness. Methods Observational retrospective study of APERIO® (AP) vs. new generation APERIO® Hybrid (APH) (Acandis®, Pforzheim, Germany) stent-retriever device (01/2019-09/2020) for mechanical thrombectomy (MT) in large vessel occlusion (LVO) stroke. Primary effectiveness endpoint was successful recanalization eTICI (expanded Thrombolysis In Cerebral Ischemia) ≥ 2b67, primary safety endpoint was occurrence of hemorrhagic complications after MT. Secondary outcome measures were time from groin puncture to first pass and successful reperfusion, and the total number of passes needed to achieve the final recanalization result. Results A total of 298 patients with LVO stroke who were treated by MT matched the inclusion criteria: 148 patients (49.7\%) treated with AP vs. 150 patients (50.3\%) treated with new generation APH. Successful recanalization was not statistically different between both groups: 75.7\% for AP vs. 79.3\% for APH; p = 0.450. Postinterventional hemorrhagic complications and particularly subarachnoid hemorrhage as the entity possibly associated with stent-retriever device type was significantly less frequent in the group treated with the APH: 29.7\% for AP and 16.0\% for APH; p = 0.005; however, rates of symptomatic hemorrhage with clinical deterioration and in domo mortality were not statistically different. Neither the median number of stent-retriever passages needed to achieve final recanalization, time from groin puncture to first pass, time from groin puncture to final recanalization nor the number of cases in which successful recanalization could only be achieved by using a different stent-retriever as bail-out device differed between both groups. Conclusion In the specific example of the APERIO® stent-retriever device, we observed that further technological developments of the new generation device were not associated with disadvantages with respect to typical observational indicators of safety or effectiveness.}, language = {en} } @article{LorenzMusacchioKunstmannetal.2022, author = {Lorenz, Delia and Musacchio, Thomas and Kunstmann, Erdmute and Grauer, Eva and Pluta, Natalie and Stock, Annika and Speer, Christian P. and Hebestreit, Helge}, title = {A case report of Sanfilippo syndrome - the long way to diagnosis}, series = {BMC Neurology}, volume = {22}, journal = {BMC Neurology}, number = {1}, doi = {10.1186/s12883-022-02611-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300465}, year = {2022}, abstract = {Background Mucopolysaccharidosis type III (Sanfilippo syndrome) is a lysosomal storage disorder, caused by a deficiency in the heparan-N-sulfatase enzyme involved in the catabolism of the glycosaminoglycan heparan sulfate. It is characterized by early nonspecific neuropsychiatric symptoms, followed by progressive neurocognitive impairment in combination with only mild somatic features. In this patient group with a broad clinical spectrum a significant genotype-phenotype correlation with some mutations leading to a slower progressive, attenuated course has been demonstrated. Case presentation Our patient had complications in the neonatal period and was diagnosed with Mucopolysaccharidosis IIIa only at the age of 28 years. He was compound heterozygous for the variants p.R245H and p.S298P, the latter having been shown to lead to a significantly milder phenotype. Conclusions The diagnostic delay is even more prolonged in this patient population with comorbidities and a slowly progressive course of the disease.}, language = {en} } @article{GuggenbergerTorreLudwigetal.2022, author = {Guggenberger, Konstanze Viktoria and Torre, Giulia Dalla and Ludwig, Ute and Vogel, Patrick and Weng, Andreas Max and Vogt, Marius Lothar and Fr{\"o}hlich, Matthias and Schmalzing, Marc and Raithel, Esther and Forman, Christoph and Urbach, Horst and Meckel, Stephan and Bley, Thorsten Alexander}, title = {Vasa vasorum of proximal cerebral arteries after dural crossing - potential imaging confounder in diagnosing intracranial vasculitis in elderly subjects on black-blood MRI}, series = {European Radiology}, volume = {32}, journal = {European Radiology}, number = {2}, issn = {1432-1084}, doi = {10.1007/s00330-021-08181-5}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-266524}, pages = {1276-1284}, year = {2022}, abstract = {Objectives Vessel wall enhancement (VWE) may be commonly seen on MRI images of asymptomatic subjects. This study aimed to characterize the VWE of the proximal internal carotid (ICA) and vertebral arteries (VA) in a non-vasculitic elderly patient cohort. Methods Cranial MRI scans at 3 Tesla were performed in 43 patients (aged ≥ 50 years) with known malignancy for exclusion of cerebral metastases. For vessel wall imaging (VWI), a high-resolution compressed-sensing black-blood 3D T1-weighted fast (turbo) spin echo sequence (T1 CS-SPACE prototype) was applied post gadolinium with an isotropic resolution of 0.55 mm. Bilateral proximal intradural ICA and VA segments were evaluated for presence, morphology, and longitudinal extension of VWE. Results Concentric VWE of the proximal intradural ICA was found in 13 (30\%) patients, and of the proximal intradural VA in 39 (91\%) patients. Mean longitudinal extension of VWE after dural entry was 13 mm in the VA and 2 mm in the ICA. In 14 of 39 patients (36\%) with proximal intradural VWE, morphology of VWE was suggestive of the mere presence of vasa vasorum. In 25 patients (64 \%), morphology indicated atherosclerotic lesions in addition to vasa vasorum. Conclusions Vasa vasorum may account for concentric VWE within the proximal 2 mm of the ICA and 13 mm of the VA after dural entry in elderly subjects. Concentric VWE in these locations should not be confused with large artery vasculitis. Distal to these segments, VWE may be more likely related to pathologic conditions such as vasculitis.}, language = {en} } @article{TraubOttoSelletal.2022, author = {Traub, Jan and Otto, Markus and Sell, Roxane and G{\"o}pfert, Dennis and Homola, Gy{\"o}rgy and Steinacker, Petra and Oeckl, Patrick and Morbach, Caroline and Frantz, Stefan and Pham, Mirko and St{\"o}rk, Stefan and Stoll, Guido and Frey, Anna}, title = {Serum phosphorylated tau protein 181 and neurofilament light chain in cognitively impaired heart failure patients}, series = {Alzheimer's Research \& Therapy}, volume = {14}, journal = {Alzheimer's Research \& Therapy}, doi = {10.1186/s13195-022-01087-4}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300515}, year = {2022}, abstract = {Background Chronic heart failure (HF) is known to increase the risk of developing Alzheimer's dementia significantly. Thus, detecting and preventing mild cognitive impairment, which is common in patients with HF, is of great importance. Serum biomarkers are increasingly used in neurological disorders for diagnostics, monitoring, and prognostication of disease course. It remains unclear if neuronal biomarkers may help detect cognitive impairment in this high-risk population. Also, the influence of chronic HF and concomitant renal dysfunction on these biomarkers is not well understood. Methods Within the monocentric Cognition.Matters-HF study, we quantified the serum levels of phosphorylated tau protein 181 (pTau) and neurofilament light chain (NfL) of 146 extensively phenotyped chronic heart failure patients (aged 32 to 85 years; 15.1\% women) using ultrasensitive bead-based single-molecule immunoassays. The clinical work-up included advanced cognitive testing and cerebral magnetic resonance imaging (MRI). Results Serum concentrations of NfL ranged from 5.4 to 215.0 pg/ml (median 26.4 pg/ml) and of pTau from 0.51 to 9.22 pg/ml (median 1.57 pg/ml). We detected mild cognitive impairment (i.e., T-score < 40 in at least one cognitive domain) in 60\% of heart failure patients. pTau (p = 0.014), but not NfL, was elevated in this group. Both NfL (ρ = - 0.21; p = 0.013) and pTau (ρ = - 0.25; p = 0.002) related to the cognitive domain visual/verbal memory, as well as white matter hyperintensity volume and cerebral and hippocampal atrophy. In multivariable analysis, both biomarkers were independently influenced by age (T = 4.6 for pTau; T = 5.9 for NfL) and glomerular filtration rate (T = - 2.4 for pTau; T = - 3.4 for NfL). Markers of chronic heart failure, left atrial volume index (T = 4.6) and NT-proBNP (T = 2.8), were further cardiological determinants of pTau and NfL, respectively. In addition, pTau was also strongly affected by serum creatine kinase levels (T = 6.5) and ferritin (T = - 3.1). Conclusions pTau and NfL serum levels are strongly influenced by age-dependent renal and cardiac dysfunction. These findings point towards the need for longitudinal examinations and consideration of frequent comorbidities when using neuronal serum biomarkers.}, language = {en} } @article{HerrmannMuellerGraffKaulitzetal.2022, author = {Herrmann, David P. and M{\"u}ller-Graff, Franz-Tassilo and Kaulitz, Stefan and Cebulla, Mario and Kurz, Anja and Hagen, Rudolf and Neun, Tilmann and Rak, Kristen}, title = {Application of intentional facial nerve stimulation during cochlear implantation as an electrophysiological tool to estimate the intracochlear electrode position}, series = {Scientific Reports}, volume = {12}, journal = {Scientific Reports}, number = {1}, doi = {10.1038/s41598-022-17732-9}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300197}, year = {2022}, abstract = {This proof of concept describes the use of evoked electromyographic (EMG) activation of the facial nerve for intraoperative monitoring of the electrode insertion during cochlear implantation (CI). Intraoperative EMG measurements from the facial nerve were conducted in nine patients undergoing CI implantation. Electric current pulses were emitted from contacts on the CI array during and immediately after electrode insertion. For control, the results of EMG measurements were compared to postoperative flat panel volume computed tomography scans with secondary reconstruction (fpVCT\(_{SECO}\)). During insertion, the EMG response evoked by the electrical stimulation from the CI was growing with the stimulating contact approaching the facial nerve and declined with increasing distance. After full insertion, contacts on the apical half of the CI array stimulated higher EMG responses compared with those on the basal half. Comparison with postoperative imaging demonstrated that electrode contacts stimulating high EMG responses had the shortest distances to the facial nerve. It could be demonstrated that electrically evoked EMG activation of the facial nerve can be used to monitor the progress during CI electrode insertion and to control the intracochlear electrode position after full insertion.}, language = {en} }