@article{WernerBundschuhBundschuhetal.2018, author = {Werner, Rudolf A. and Bundschuh, Ralph A. and Bundschuh, Lena and Javadi, Mehrbod S. and Higuchi, Takahiro and Weich, Alexander and Sheikhbahaei, Sara and Pienta, Kenneth J. and Buck, Andreas K. and Pomper, Martin G. and Gorin, Michael A. and Lapa, Constantin and Rowe, Steven P.}, title = {MI-RADS: Molecular Imaging Reporting and Data Systems - A Generalizable Framework for Targeted Radiotracers with Theranostic Implications}, series = {Annals of Nuclear Medicine}, journal = {Annals of Nuclear Medicine}, issn = {0914-7187}, doi = {10.1007/s12149-018-1291-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-166995}, year = {2018}, abstract = {Both prostate-specific membrane antigen (PSMA)- and somatostatin receptor (SSTR)-targeted positron emission tomography (PET) imaging agents for staging and restaging of prostate carcinoma or neuroendocrine tumors, respectively, are seeing rapidly expanding use. In addition to diagnostic applications, both classes of radiotracers can be used to triage patients for theranostic endoradiotherapy. While interpreting PSMA- or SSTR-targeted PET/computed tomography (CT) scans, the reader has to be aware of certain pitfalls. Adding to the complexity of the interpretation of those imaging agents, both normal biodistribution, and also false-positive and -negative findings differ between PSMA- and SSTR-targeted PET radiotracers. Herein summarized under the umbrella term molecular imaging reporting and data systems (MI-RADS), two novel RADS classifications for PSMA- and SSTR-targeted PET imaging are described (PSMA- and SSTR-RADS). Both framework systems may contribute to increase the level of a reader's confidence and to navigate the imaging interpreter through indeterminate lesions, so that appropriate workup for equivocal findings can be pursued. Notably, PSMA- and SSTR-RADS are structured in a reciprocal fashion, i.e. if the reader is familiar with one system, the other system can readily be applied as well. In the present review we will discuss the most common pitfalls on PSMA- and SSTR-targeted PET/CT, briefly introduce PSMA- and SSTR-RADS, and define a future role of the umbrella framework MI-RADS compared to other harmonization systems.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{WernerBundschuhHiguchietal.2018, author = {Werner, Rudolf A. and Bundschuh, Ralph A. and Higuchi, Takahiro and Javadi, Mehrbod S. and Rowe, Steven P. and Zs{\´o}t{\´e}r, Norbert and Kroiss, Matthias and Fassnacht, Martin and Buck, Andreas K. and Kreissl, Michael C. and Lapa, Constantin}, title = {Volumetric and Texture Analysis of Pretherapeutic \(^{18}\)F-FDG PET can Predict Overall Survival in Medullary Thyroid Cancer Patients Treated with Vandetanib}, series = {Endocrine}, journal = {Endocrine}, issn = {1355-008X}, doi = {10.1007/s12020-018-1749-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-167910}, year = {2018}, abstract = {Purpose: The metabolically most active lesion in 2-deoxy-2-(\(^{18}\)F)fluoro-D-glucose (\(^{18}\)F-FDG) PET/CT can predict progression-free survival (PFS) in patients with medullary thyroid carcinoma (MTC) starting treatment with the tyrosine kinase inhibitor (TKI) vandetanib. However, this metric failed in overall survival (OS) prediction. In the present proof of concept study, we aimed to explore the prognostic value of intratumoral textural features (TF) as well as volumetric parameters (total lesion glycolysis, TLG) derived by pre-therapeutic \(^{18}\)F-FDG PET. Methods: Eighteen patients with progressive MTC underwent baseline \(^{18}\)F-FDG PET/CT prior to and 3 months after vandetanib initiation. By manual segmentation of the tumor burden at baseline and follow-up PET, intratumoral TF and TLG were computed. The ability of TLG, imaging-based TF, and clinical parameters (including age, tumor marker doubling times, prior therapies and RET (rearranged during transfection) mutational status) for prediction of both PFS and OS were evaluated. Results: The TF Complexity and the volumetric parameter TLG obtained at baseline prior to TKI initiation successfully differentiated between low- and high-risk patients. Complexity allocated 10/18 patients to the high-risk group with an OS of 3.3y (vs. low-risk group, OS=5.3y, 8/18, AUC=0.78, P=0.03). Baseline TLG designated 11/18 patients to the high-risk group (OS=3.5y vs. low-risk group, OS=5y, 7/18, AUC=0.83, P=0.005). The Hazard Ratio for cancer-related death was 6.1 for Complexity (TLG, 9.5). Among investigated clinical parameters, the age at initiation of TKI treatment reached significance for PFS prediction (P=0.02, OS, n.s.). Conclusions: The TF Complexity and the volumetric parameter TLG are both independent parameters for OS prediction.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{Menke2019, author = {Menke, Andreas}, title = {Is the HPA axis as target for depression outdated, or is there a new hope?}, series = {Frontiers in Psychiatry}, volume = {10}, journal = {Frontiers in Psychiatry}, number = {101}, issn = {1664-0640}, doi = {10.3389/fpsyt.2019.00101}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-195780}, year = {2019}, abstract = {Major depressive disorder (MDD) is a very common stress-related mental disorder that carries a huge burden for affected patients and the society. It is associated with a high mortality that derives from suicidality and the development of serious medical conditions such as heart diseases, diabetes, and stroke. Although a range of effective antidepressants are available, more than 50\% of the patients do not respond to the first treatment they are prescribed and around 30\% fail to respond even after several treatment attempts. The heterogeneous condition of MDD, the lack of biomarkers matching patients with the right treatments and the situation that almost all available drugs are only targeting the serotonin, norepinephrine, or dopamine signaling, without regulating other potentially dysregulated systems may explain the insufficient treatment status. The hypothalamic-pituitary-adrenal (HPA) axis is one of these other systems, there is numerous and robust evidence that it is implicated in MDD and other stress-related conditions, but up to date there is no specific drug targeting HPA axis components that is approved and no test that is routinely used in the clinical setting identifying patients for such a specific treatment. Is there still hope after these many years for a breakthrough of agents targeting the HPA axis? This review will cover tests detecting altered HPA axis function and the specific treatment options such as glucocorticoid receptor (GR) antagonists, corticotropin-releasing hormone 1 (CRH1) receptor antagonists, tryptophan 2,3-dioxygenase (TDO) inhibitors and FK506 binding protein 5 (FKBP5) receptor antagonists.}, language = {en} } @article{JustSchollBoehmeetal.2021, author = {Just, Katja S. and Scholl, Catharina and Boehme, Miriam and Kastenm{\"u}ller, Kathrin and Just, Johannes M. and Bleckwenn, Markus and Holdenrieder, Stefan and Meier, Florian and Weckbecker, Klaus and Stingl, Julia C.}, title = {Individualized versus standardized risk assessment in patients at high risk for adverse drug reactions (the IDrug randomized controlled trial) - never change a running system?}, series = {Pharmaceuticals}, volume = {14}, journal = {Pharmaceuticals}, number = {10}, issn = {1424-8247}, doi = {10.3390/ph14101056}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-248557}, year = {2021}, abstract = {The aim of this study was to compare effects of an individualized with a standardized risk assessment for adverse drug reactions to improve drug treatment with antithrombotic drugs in older adults. A randomized controlled trial was conducted in general practitioner (GP) offices. Patients aged 60 years and older, multi-morbid, taking antithrombotic drugs and at least one additional drug continuously were randomized to individualized and standardized risk assessment groups. Patients were followed up for nine months. A composite endpoint defined as at least one bleeding, thromboembolic event or death reported via a trigger list was used. Odds ratios (OR) and 95\% confidence intervals (CI) were calculated. In total, N = 340 patients were enrolled from 43 GP offices. Patients in the individualized risk assessment group met the composite endpoint more often than in the standardized group (OR 1.63 [95\%CI 1.02-2.63]) with multiple adjustments. The OR was higher in patients on phenprocoumon treatment (OR 1.99 [95\%CI 1.05-3.76]), and not significant on DOAC treatment (OR 1.52 [95\%CI 0.63-3.69]). Pharmacogenenetic variants of CYP2C9, 2C19 and VKORC1 were not observed to be associated with the composite endpoint. The results of this study may indicate that the time point for implementing individualized risk assessments is of importance.}, language = {en} } @article{HelmerHottenrottRodemersetal.2022, author = {Helmer, Philipp and Hottenrott, Sebastian and Rodemers, Philipp and Leppich, Robert and Helwich, Maja and Pryss, R{\"u}diger and Kranke, Peter and Meybohm, Patrick and Winkler, Bernd E. and Sammeth, Michael}, title = {Accuracy and Systematic Biases of Heart Rate Measurements by Consumer-Grade Fitness Trackers in Postoperative Patients: Prospective Clinical Trial}, series = {Journal of Medical Internet Research}, volume = {24}, journal = {Journal of Medical Internet Research}, number = {12}, doi = {10.2196/42359}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-299679}, year = {2022}, abstract = {Background: Over the recent years, technological advances of wrist-worn fitness trackers heralded a new era in the continuous monitoring of vital signs. So far, these devices have primarily been used for sports. Objective: However, for using these technologies in health care, further validations of the measurement accuracy in hospitalized patients are essential but lacking to date. Methods: We conducted a prospective validation study with 201 patients after moderate to major surgery in a controlled setting to benchmark the accuracy of heart rate measurements in 4 consumer-grade fitness trackers (Apple Watch 7, Garmin Fenix 6 Pro, Withings ScanWatch, and Fitbit Sense) against the clinical gold standard (electrocardiography). Results: All devices exhibited high correlation (r≥0.95; P<.001) and concordance (rc≥0.94) coefficients, with a relative error as low as mean absolute percentage error <5\% based on 1630 valid measurements. We identified confounders significantly biasing the measurement accuracy, although not at clinically relevant levels (mean absolute error<5 beats per minute). Conclusions: Consumer-grade fitness trackers appear promising in hospitalized patients for monitoring heart rate.}, language = {en} } @article{DongBoeppleThieletal.2023, author = {Dong, Meng and B{\"o}pple, Kathrin and Thiel, Julia and Winkler, Bernd and Liang, Chunguang and Schueler, Julia and Davies, Emma J. and Barry, Simon T. and Metsalu, Tauno and M{\"u}rdter, Thomas E. and Sauer, Georg and Ott, German and Schwab, Matthias and Aulitzky, Walter E.}, title = {Perfusion air culture of precision-cut tumor slices: an ex vivo system to evaluate individual drug response under controlled culture conditions}, series = {Cells}, volume = {12}, journal = {Cells}, number = {5}, issn = {2073-4409}, doi = {10.3390/cells12050807}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-311030}, year = {2023}, abstract = {Precision-cut tumor slices (PCTS) maintain tissue heterogeneity concerning different cell types and preserve the tumor microenvironment (TME). Typically, PCTS are cultured statically on a filter support at an air-liquid interface, which gives rise to intra-slice gradients during culture. To overcome this problem, we developed a perfusion air culture (PAC) system that can provide a continuous and controlled oxygen medium, and drug supply. This makes it an adaptable ex vivo system for evaluating drug responses in a tissue-specific microenvironment. PCTS from mouse xenografts (MCF-7, H1437) and primary human ovarian tumors (primary OV) cultured in the PAC system maintained the morphology, proliferation, and TME for more than 7 days, and no intra-slice gradients were observed. Cultured PCTS were analyzed for DNA damage, apoptosis, and transcriptional biomarkers for the cellular stress response. For the primary OV slices, cisplatin treatment induced a diverse increase in the cleavage of caspase-3 and PD-L1 expression, indicating a heterogeneous response to drug treatment between patients. Immune cells were preserved throughout the culturing period, indicating that immune therapy can be analyzed. The novel PAC system is suitable for assessing individual drug responses and can thus be used as a preclinical model to predict in vivo therapy responses.}, language = {en} }