@phdthesis{Ames2015, author = {Ames, Christopher}, title = {Molecular Beam Epitaxy of 2D and 3D HgTe, a Topological Insulator}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-151136}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {In the present thesis the MBE growth and sample characterization of HgTe structures is investigated and discussed. Due to the first experimental discovery of the quantum Spin Hall effect (QSHE) in HgTe quantum wells, this material system attains a huge interest in the spintronics society. Because of the long history of growing Hg-based heterostructures here at the Experimentelle Physik III in W{\"u}rzburg, there are very good requirements to analyze this material system more precisely and in new directions. Since in former days only doped HgTe quantum wells were grown, this thesis deals with the MBE growth in the (001) direction of undoped HgTe quantum wells, surface located quantum wells and three dimensional bulk layers. All Hg-based layers were grown on CdTe substrates which generate strain in the layer stack and provide therefore new physical effects. In the same time, the (001) CdTe growth was investigated on n-doped (001) GaAs:Si because the Japanese supplier of CdTe substrates had a supply bottleneck due to the Tohoku earthquake and its aftermath in 2011. After a short introduction of the material system, the experimental techniques were demonstrated and explained explicitly. After that, the experimental part of this thesis is displayed. So, the investigation of the (001) CdTe growth on (001) GaAs:Si is discussed in chapter 4. Firstly, the surface preparation of GaAs:Si by oxide desorption is explored and analyzed. Here, rapid thermal desorption of the GaAs oxide with following cool down in Zn atmosphere provides the best results for the CdTe due to small holes at the surface, while e.g. an atomic flat GaAs buffer deteriorates the CdTe growth quality. The following ZnTe layer supplies the (001) growth direction of the CdTe and exhibits best end results of the CdTe for 30 seconds growth time at a flux ratio of Zn/Te ~ 1/1.2. Without this ZnTe layer, CdTe will grow in the (111) direction. However, the main investigation is here the optimization of the MBE growth of CdTe. The substrate temperature, Cd/Te flux ratio and the growth time has to be adjusted systematically. Therefore, a complex growth process is developed and established. This optimized CdTe growth process results in a RMS roughness of around 2.5 nm and a FWHM value of the HRXRD w-scan of 150 arcsec. Compared to the literature, there is no lower FWHM value traceable for this growth direction. Furthermore, etch pit density measurements show that the surface crystallinity is matchable with the commercial CdTe substrates (around 1x10^4 cm^(-2)). However, this whole process is not completely perfect and offers still room for improvements. The growth of undoped HgTe quantum wells was also a new direction in research in contrast to the previous n-doped grown HgTe quantum wells. Here in chapter 5, the goal of very low carrier densities was achieved and therefore it is now possible to do transport experiments in the n - and p - region by tuning the gate voltage. To achieve this high sample quality, very precise growth of symmetric HgTe QWs and their HRXRD characterization is examined. Here, the quantum well thickness can now determined accurate to under 0.3 nm. Furthermore, the transport analysis of different quantum well thicknesses shows that the carrier density and mobility increase with rising HgTe layer thickness. However, it is found out that the band gap of the HgTe QW closes indirectly at a thickness of 11.6 nm. This is caused by the tensile strained growth on CdTe substrates. Moreover, surface quantum wells are studied. These quantum wells exhibit no or a very thin HgCdTe cap. Though, oxidization and contamination of the surface reduces here the carrier mobility immensely and a HgCdTe layer of around 5 nm provides the pleasing results for transport experiments with superconductors connected to the topological insulator [119]. A completely new achievement is the realization of MBE growth of HgTe quantum wells on CdTe/GaAs:Si substrates. This is attended by the optimization of the CdTe growth on GaAs:Si. It exposes that HgTe quantum wells grown in-situ on optimized CdTe/GaAs:Si show very nice transport data with clear Hall plateaus, SdH oscillations, low carrier densities and carrier mobilities up to 500 000 cm^2/Vs. Furthermore, a new oxide etching process is developed and analyzed which should serve as an alternative to the standard HCl process which generates volcano defects at some time. However, during the testing time the result does not differ in Nomarski, HRXRD, AFM and transport measurements. Here, long-time tests or etching and mounting in nitrogen atmosphere may provide new elaborate results. The main focus of this thesis is on the MBE growth and standard characterization of HgTe bulk layers and is discussed in chapter 6. Due to the tensile strained growth on lattice mismatched CdTe, HgTe bulk opens up a band gap of around 22 meV at the G-point and exhibits therefore its topological surface states. The analysis of surface condition, roughness, crystalline quality, carrier density and mobility via Nomarski, AFM, XPS, HRXRD and transport measurements is therefore included in this work. Layer thickness dependence of carrier density and mobility is identified for bulk layer grown directly on CdTe substrates. So, there is no clear correlation visible between HgTe layer thickness and carrier density or mobility. So, the carrier density is almost constant around 1x10^11 cm^(-2) at 0 V gate voltage. The carrier mobility of these bulk samples however scatters between 5 000 and 60 000 cm^2/Vs almost randomly. Further experiments should be made for a clearer understanding and therefore the avoidance of unusable bad samples.But, other topological insulator materials show much higher carrier densities and lower mobility values. For example, Bi2Se3 exhibits just density values around 1019 cm^(-2) and mobility values clearly below 5000 cm2/Vs. The carrier density however depends much on lithography and surface treatment after growth. Furthermore, the relaxation behavior and critical thickness of HgTe grown on CdTe is determined and is in very good agreement with theoretical prediction (d_c = 155 nm). The embedding of the HgTe bulk layer between HgCdTe layers created a further huge improvement. Similar to the quantum well structures the carrier mobility increases immensely while the carrier density levels at around 1x10^11 cm^(-2) at 0 V gate voltage as well. Additionally, the relaxation behavior and critical thickness of these barrier layers has to be determined. HgCdTe grown on commercial CdTe shows a behavior as predicted except the critical thickness which is slightly higher than expected (d_c = 850 nm). Otherwise, the relaxation of HgCdTe grown on CdTe/GaAs:Si occurs in two parts. The layer is fully strained up to 250 nm. Between 250 nm and 725 nm the HgCdTe film starts to relax randomly up to 10 \%. The relaxation behavior for thicknesses larger than 725 nm occurs than linearly to the inverse layer thickness. A explanation is given due to rough interface conditions and crystalline defects of the CdTe/GaAs:Si compared to the commercial CdTe substrate. HRXRD and AFM data support this statement. Another point is that the HgCdTe barriers protect the active HgTe layer and because of the high carrier mobilities the Hall measurements provide new transport data which have to be interpreted more in detail in the future. In addition, HgTe bulk samples show very interesting transport data by gating the sample from the top and the back. It is now possible to manipulate the carrier densities of the top and bottom surface states almost separately. The back gate consisting of the n-doped GaAs substrate and the thick insulating CdTe buffer can tune the carrier density for Delta(n) ~ 3x10^11 cm^(-2). This is sufficient to tune the Fermi energy from the p-type into the n-type region [138]. In this thesis it is shown that strained HgTe bulk layers exhibit superior transport data by embedding between HgCdTe barrier layers. The n-doped GaAs can here serve as a back gate. Furthermore, MBE growth of high crystalline, undoped HgTe quantum wells shows also new and extended transport output. Finally, it is notable that due to the investigated CdTe growth on GaAs the Hg-based heterostructure MBE growth is partially independent from commercial suppliers.}, subject = {Quecksilbertellurid}, language = {en} } @phdthesis{BreuergebHemberger2015, author = {Breuer [geb. Hemberger], Kathrin R. F.}, title = {Effiziente 3D Magnetresonanzbildgebung schnell abfallender Signale}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-150750}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {In der vorliegenden Arbeit wird die Rotated-Cone-UTE-Sequenz (RC-UTE), eine 3D k-Raum-Auslesetechnik mit homogener Verteilung der Abtastdichte, vorgestellt. Diese 3D MR-Messtechnik erm{\"o}glicht die f{\"u}r die Detektion von schnell abfallenden Signalen notwendigen kurzen Echozeiten und weist eine h{\"o}here SNR-Effizienz als konventionelle radiale Pulssequenzen auf. Die Abtastdichte ist dabei in radialer und azimutaler Richtung angepasst. Simulationen und Messungen in vivo zeigen, dass die radiale Anpassung das T2-Blurring reduziert und die SNR-Effizienz erh{\"o}ht. Die Drehung der Trajektorie in azimutale Richtung erm{\"o}glicht die Reduzierung der Unterabtastung bei gleicher Messzeit bzw. eine Reduzierung der Messzeit ohne Aufl{\"o}sungsverlust. Die RC-UTE-Sequenz wurde erfolgreich f{\"u}r die Bildgebung des Signals des kortikalen Knochens und der Lunge in vivo angewendet. Im Vergleich mit der grundlegenden UTE-Sequenz wurden die Vorteile von RC-UTE in allen Anwendungsbeispielen aufgezeigt. Die transversalen Relaxationszeit T2* des kortikalen Knochen bei einer Feldst{\"a}rke von 3.0T und der Lunge bei 1.5T und 3.0T wurde in 3D isotroper Aufl{\"o}sung gemessen. Außerdem wurde die Kombination von RC-UTE-Sequenz mit Methoden der Magnetisierungspr{\"a}paration zur besseren Kontrasterzeugung gezeigt. Dabei wurden die Doppel-Echo-Methode, die Unterdr{\"u}ckung von Komponenten mit langer Relaxationszeit T2 durch Inversionspulse und der Magnetisierungstransfer-Kontrast angewendet. Die Verwendung der RC-UTE-Sequenz f{\"u}r die 3D funktionelle Lungenbildgebung wird ebenfalls vorgestellt. Mit dem Ziel der umfassenden Charakterisierung der Lungenfunktion in 3D wurde die simultane Messung T1-gewichteter Bilder und quantitativer T2*-Karten f{\"u}r verschiedene Atemzust{\"a}nde an sechs Probanden durchgef{\"u}hrt. Mit der hier vorgestellten Methode kann die Lungenfunktion in 3D {\"u}ber T1-Wichtung, quantitative T2*-Messung und Rekonstruktion verschiedener Atemzust{\"a}nde durch Darstellung von Ventilation, Sauerstofftransport und Volumen{\"a}nderung beurteilt werden.}, subject = {Kernspintomografie}, language = {de} } @phdthesis{Fischer2015, author = {Fischer, Julian}, title = {Koh{\"a}renz- und Magnetfeldmessungen an Polariton-Kondensaten unterschiedlicher r{\"a}umlicher Dimensionen}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-149488}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {Die Bose-Einstein-Kondensation (BEK) und die damit verbundenen Effekte wie Superfluidit{\"a}t und Supraleitung sind faszinierende Resultate der Quantennatur von Bosonen. Nachdem die Bose-Einstein-Kondensation f{\"u}r Atom-Systeme nur bei Temperaturen nahe dem absoluten Nullpunkt realisierbar ist, was einen enormen technologischen Aufwand ben{\"o}tigt, wurden Bosonen mit wesentlich kleineren Massen zur Untersuchung der BEK gesucht. Hierf{\"u}r bieten sich Quasiteilchen in Festk{\"o}rpern wie Magnonen oder Exzitonen an, da deren effektive Massen sehr klein sind und die Kondensationstemperatur dementsprechend h{\"o}her ist als f{\"u}r ein atomares System. Ein weiteres Quasiteilchen ist das Exziton-Polariton als Resultat der starken Licht-Materie-Wechselwirkung in Halbleitermikrokavit{\"a}ten, welches sowohl Materie- als auch Photoneigenschaften hat und dessen Masse theoretisch eine BEK bis Raumtemperatur erlaubt. Ein weiterer Vorteil dieses System ist die einfache Erzeugung des Bose-Einstein-Kondensats in diesen Systemen durch elektrisches oder optisches Injizieren von Exzitonen in die Halbleiter-Quantenfilme der Struktur. Außerdem kann die Impulsraumverteilung dieser Quasiteilchen leicht durch einfache experimentelle Methoden mittels eines Fourierraumspektroskopie-Aufbaus bestimmt werden. Durch die winkelabh{\"a}ngige Messung der Emission kann direkt auf die Impulsverteilung der Exziton-Polaritonen in der Quantenfilmebene zur{\"u}ckgerechnet werden, die zur Identifikation der BEK hilfreich ist. Deshalb wird das Exziton-Polariton als ein Modellsystem f{\"u}r die Untersuchung von Bose-Einstein-Kondensation in Festk{\"o}rpern und den damit in Relation stehenden Effekten angesehen. In dieser Arbeit wird die Grundzustandskondensation von Exziton-Polaritonen in Halbleitermikrokavit{\"a}ten verschiedener Dimensionen realisiert und deren Emissionseigenschaften untersucht. Dabei wird vor allem die Wechselwirkung des Polariton-Kondensats mit der der unkondensierten Polaritonen bzw. der Quantenfilm-Exzitonen im externen Magnetfeld verglichen und ein Nachweis zum Erhalt der starken Kopplung {\"u}ber die Polariton-Kondensationsschwelle hinaus entwickelt. Außerdem werden die Koh{\"a}renzeigenschaften von null- und eindimensionalen Polariton-Kondensaten durch Bestimmung der Korrelationsfunktion erster beziehungsweise zweiter Ordnung analysiert. Als Materialsystem werden hierbei die III/V-Halbleiter gew{\"a}hlt und die Quantenfilme bestehen bei allen Messungen aus GaAs, die von einer AlAs Kavit{\"a}t umgeben sind. Eindimensionale Polariton-Kondensation - r{\"a}umliche Koh{\"a}renz der Polariton-Dr{\"a}hte Im ersten experimentellen Teil dieser Arbeit (Kapitel 1) wird die Kondensation der Polaritonen in eindimensionalen Dr{\"a}hten unter nicht-resonanter optischer Anregung untersucht. Dabei werden verschiedene Drahtl{\"a}ngen und -breiten verwendet, um den Einfluss des zus{\"a}tzlichen Einschlusses auf die Polariton-Dispersion bestimmen zu k{\"o}nnen. Ziel dieser Arbeit ist es, ein eindimensionales Bose-Einstein-Kondensat mit einer konstanten r{\"a}umlichen Koh{\"a}renz nach dem zentralen Abfall der g^(1)(r)-Funktion f{\"u}r große Abst{\"a}nde r in diesen Dr{\"a}hten zu realisieren (sogenannte langreichweitige Ordnung im System, ODLRO (Abk{\"u}rzung aus dem Englischen off-diagonal long-range order). Durch Analyse der Fernfeldemissionseigenschaften k{\"o}nnen mehrere Polariton-{\"A}ste, der eindimensionale Charakter und die Polariton-Kondensation in 1D-Systemen nachgewiesen werden. Daraufhin wird die r{\"a}umliche Koh{\"a}renzfunktion g^(1)(r) mithilfe eines hochpr{\"a}zisen Michelson-Interferometer, das im Rahmen dieser Arbeit aufgebaut wurde, bestimmt. Die g^(1)(r)-Funktion nimmt hierbei {\"u}ber große Abst{\"a}nde im Vergleich zur thermischen De-Broglie-Wellenl{\"a}nge einen konstanten Plateauwert an, der abh{\"a}ngig von der Anregungsleistung ist. Unterhalb der Polariton-Kondensationsschwelle (Schwellleistung P_S) ist kein Plateau sichtbar und die r{\"a}umliche Koh{\"a}renz ist nur im zentralen Bereich von unter |r| < 1 µm vorhanden. Mit ansteigender Anregungsleistung nimmt das zentrale Maximum in der Weite zu und es bildet sich das Plateau der g^(1)(r)-Funktion aus, das nur außerhalb des Drahtes auf Null abf{\"a}llt. Bei P=1,6P_S ist das Plateau maximal und betr{\"a}gt circa 0,15. Außerdem kann nachgewiesen werden, dass mit steigender Temperatur die Plateauh{\"o}he abnimmt und schließlich bei T=25K nicht mehr gemessen werden kann. Hierbei ist dann nur noch das zentrale Maximum der Koh{\"a}renzfunktion g^(1)(r) sichtbar. Weiterhin werden die Ergebnisse mit einer modernen mikroskopischen Theorie, die auf einem stochastischen Mastergleichungssystem basiert, verglichen, wodurch die experimentellen Daten reproduziert werden k{\"o}nnen. Im letzten Teil des Kapitels wird noch die Koh{\"a}renzfunktion g^(1)(r) im 1D-Fall mit der eines planaren Polariton-Kondensats verglichen (2D). Nulldimensionale Polariton-Kondensation - Kondensation und Magnetfeldwechselwirkung in einer Hybridkavit{\"a}t Im zweiten Teil der Arbeit wird die Polariton-Kondensation in einer neuartigen Hybridkavit{\"a}t untersucht. Der Aufbau des unteren Spiegels und der Kavit{\"a}t inklusive der 12 verwendeten Quantenfilme ist analog zu den gew{\"o}hnlichen Mikrokavit{\"a}ten auf Halbleiterbasis. Der obere Spiegel jedoch besteht aus einer Kombination von einem DBR (Abk{\"u}rzung aus dem Englischen distributed Bragg reflector) und einem Brechungsindexkontrast-Gitter mit einem Luft-Halbleiter{\"u}bergang (gr{\"o}ßt m{\"o}glichster Brechungsindexkontrast). Durch die quadratische Strukturgr{\"o}ße des Gitters (Seitenl{\"a}nge 5µm) sind die Polaritonen zus{\"a}tzlich zur Wachstumsrichtung noch in der Quantenfilmebene eingesperrt, so dass sie als nulldimensional angesehen werden k{\"o}nnen (Einschluss auf der ungef{\"a}hren Gr{\"o}ße der thermischen De-Broglie-Wellenl{\"a}nge). Um den Erhalt der starken Kopplung {\"u}ber die Kondensationsschwelle hinaus nachweisen zu k{\"o}nnen, wird ein Magnetfeld in Wachstumsrichtung angelegt und die diamagnetische Verschiebung des Quantenfilms mit der des 0D-Polariton-Kondensats verglichen. Hierdurch kann das Polariton-Kondensat von dem konventionellen Photonlasing in solchen Strukturen unterschieden werden. Weiterhin wird als letztes Unterscheidungsmerkmal zwischen Photonlasing und Polariton-Kondensation eine Messung der Autokorrelationsfunktion zweiter Ordnung g^(2)(t) durchgef{\"u}hrt. Dabei kann ein Wiederanstieg des g^(2)(t = 0)-Werts mit ansteigender Anregungsleistung nachgewiesen werden, nachdem an der Kondensationsschwelle der g^(2)(t = 0)-Wert auf 1 abgefallen ist, was auf eine zeitliche Koh{\"a}renzzunahme im System hinweist. Oberhalb der Polariton-Kondensationsschwelle P_S steigt der g^(2)(t = 0)-Wert wieder aufgrund zunehmender Dekoh{\"a}renzprozesse, verursacht durch die im System ansteigende Polariton-Polariton-Wechselwirkung, auf Werte gr{\"o}ßer als 1 an. F{\"u}r einen gew{\"o}hnlichen Photon-Laser (VCSEL, Abk{\"u}rzung aus dem Englischen vertical-cavity surface-emitting laser) im monomodigen Betrieb kann mit steigender Anregungsleistung kein Wiederanstieg des g^(2)(t = 0)-Werts gemessen werden. Somit stellt dies ein weiteres Unterscheidungsmerkmal zwischen Polariton-Kondensation und Photonlasing dar. Zweidimensionale Polariton-Kondensation - Wechselwirkung mit externem Magnetfeld Im letzten experimentellen Kapitel dieser Arbeit wird die Magnetfeldwechselwirkung der drei m{\"o}glichen Regime der Mikrokavit{\"a}tsemission einer planaren Struktur (zweidimensional) untersucht. Dazu werden zuerst durch eine Leistungsserie bei einer Verstimmung des Photons und des Quantenfilm-Exzitons von d =-6,5meV das lineare, polaritonische Regime, das Polariton-Kondensat und bei weiterer Erh{\"o}hung der Anregungsleistung das Photonlasing identifiziert. Diese drei unterschiedlichen Regime werden daraufhin im Magnetfeld von B=0T-5T auf ihre Zeeman-Aufspaltung und ihre diamagnetische Verschiebung untersucht und die Ergebnisse der Magnetfeldwechselwirkung werden anschließend miteinander verglichen. Im linearen Regime kann die Abh{\"a}ngigkeit der Zeeman-Aufspaltung und der diamagnetischen Verschiebung vom exzitonischen Anteils des Polaritons best{\"a}tigt werden. Oberhalb der Polariton-Kondensationsschwelle wird eine gr{\"o}ßere diamagnetische Verschiebung gemessen als f{\"u}r die gleiche Verstimmung im linearen Regime. Dieses Verhalten wird durch Abschirmungseffekte der Coulomb-Anziehung von Elektronen und L{\"o}chern erkl{\"a}rt, was in einer Erh{\"o}hung des Bohrradius der Exzitonen resultiert. Auch die Zeeman-Aufspaltung oberhalb der Polariton-Kondensationsschwelle zeigt ein vom unkondensierten Polariton abweichendes Verhalten, es kommt sogar zu einer Vorzeichenumkehr der Aufspaltung im Magnetfeld. Aufgrund der langen Spin-Relaxationszeiten von 300ps wird eine Theorie basierend auf der im thermischen Gleichgewichtsfall entwickelt, die nur ein partielles anstatt eines vollst{\"a}ndigen thermischen Gleichgewicht annimmt. So befinden sich die einzelnen Spin-Komponenten im Gleichgewicht, w{\"a}hrend zwischen den beiden Spin-Komponenten kein Gleichgewicht vorhanden ist. Dadurch kann die Vorzeichenumkehr als ein Zusammenspiel einer dichteabh{\"a}ngigen Blauverschiebung jeder einzelner Spin-Komponente und der Orientierung der Spins im Magnetfeld angesehen werden. F{\"u}r das Photonlasing kann keine Magnetfeldwechselwirkung festgestellt werden, wodurch verdeutlicht wird, dass die Messung der Zeeman-Aufspaltung beziehungsweise der diamagnetischen Verschiebung im Magnetfeld als ein eindeutiges Werkzeug zur Unterscheidung zwischen Polariton-Kondensation und Photonlasing verwendet werden kann.}, subject = {Exziton-Polariton}, language = {de} } @phdthesis{Schwarz2015, author = {Schwarz, Christoph Benjamin}, title = {Full vector-field control of femtosecond laser pulses with an improved optical design}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-142948}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {The controlled shaping of ultrashort laser pulses is a powerful technology and applied in many laser laboratories today. Most of the used pulse shapers are only able to produce linearly polarized pulses shaped in amplitude and phase. Some devices are also capable of producing limited time-varying polarization profiles, but they are not able to control the amplitude. However, for some state-of-the-art non-linear time-resolved methods, such as polarization-enhanced two-dimensional spectroscopy, the possibility of controlling the amplitude and the polarization simultaneously is desirable. Over the last years, different concepts have been developed to overcome these restrictions and to manipulate the complete vector-field of an ultrashort laser pulse with independent control over all four degrees of freedom - phase, amplitude, orientation, and ellipticity. The aim of this work was to build such a vector-field shaper. While the basic concept used for our setup is based on previous designs reported in the literature, the goal was to develop an optimized optical design that minimizes artifacts, allowing for the generation of predefined polarization pulse sequences with the highest achievable accuracy. In Chapter 3, different approaches reported in the literature for extended and unrestricted vector-field control were examined and compared in detail. Based on this analysis, we decided to follow the approach of modulating the spectral phase and amplitude of two perpendicularly polarized pulses independently from each other in two arms of an interferometer and recombining them to a single laser pulse to gain control over the complete vector field. As described in Chapter 4, the setup consists of three functional groups: i) an optical component to generate and recombine the two polarized beams, ii) a 4f setup, and iii) a refracting telescope to direct the two beams under two different angles of incidence onto the grating of the 4f setup in a common-path geometry. This geometry was chosen to overcome potential phase instabilities of an interferometric vector-field shaper. Manipulating the two perpendicularly polarized pulses simultaneously within one 4f setup and using adjacent pixel groups of the same liquid-crystal spatial light modulator (LC SLM) for the two polarizations has the advantages that only a single dual-layer LC SLM is required and that a robust and compact setup was achieved. The shaping capabilities of the presented design were optimized by finding the best parameters for the setup through numerical calculations to adjust the frequency distributions for a broad spectrum of 740 - 880 nm. Instead of using a Wollaston prism as in previous designs, a thin-film polarizer (TFP) is utilized to generate and recombine the two orthogonally polarized beams. Artifacts such as angular dispersion and phase distortions along the beam profile which arise when a Wollaston prism is used were discussed. Furthermore, it was shown by ray-tracing simulations that in combination with a telescope and the 4f setup, a significant deformation of the beam profile would be present when using a Wollaston prism since a separation of the incoming and outgoing beam in height is needed. The ray-tracing simulations also showed that most optical aberrations of the setup are canceled out when the incoming and outgoing beams propagate in the exact same plane by inverting the beam paths. This was realized by employing a TFP in the so-called crossed-polarizer arrangement which has also the advantage that the polarization-dependent efficiencies of the TFP and the other optics are automatically compensated and that a high extinction ratio in the order of 15000:1 is reached. Chromatic aberrations are, however, not compensated by the crossed-polarizer arrangement. The ray-tracing simulations confirmed that these chromatic aberrations are mainly caused by the telescope and not by the cylindrical lens of the 4f setup. Nevertheless, in the experimentally used wavelength range of 780 - 816 nm, only minor distortions of the beam profile were observed, which were thus considered to be negligible in the presented setup. The software implementation of the pulse shaper was reviewed in Chapter 5 of this thesis. In order to perform various experiments, five different parameterizations, accounting for the extended shaping capabilities of a vector-field shaper, were developed. The Pixel Basis, the Spectral Basis, and the Spectral Taylor Basis can generally be used in combination with an optimization algorithm and are therefore well suited for quantum control experiments. For multidimensional spectroscopy, the Polarized Four-Pulse Basis was established. With this parameterization pulse sequences with up to four subpulses can be created. The polarization state of each subpulse can be specified and the relative intensity, phase, and temporal delay between consecutive subpulses can be controlled. In addition, different software programs were introduced in Chapter 5 which are required to perform the experiments conducted in this work. The experimental results were presented in Chapter 6. The frequency distribution across the LC SLM was measured proving that the optimal frequency distribution was realized experimentally. Furthermore, the excellent performance of the TFP was verified. In general, satellite pulses are emitted from the TFP due to multiple internal reflections. Various measurements demonstrated that these pulses are temporally separated by at least 4.05 ps from the main pulse and that they have vanishing intensity. The phase stability between the two arms of the presented common-path setup σ = 28.3 mrad (λ/222) over 60 minutes. To further improve this stability over very long measurement times, an on-the-fly phase reduction and stabilization (OPRAS) routine utilizing the pulse shaper itself was developed. This routine automatically produces a compressed pulse with a minimized relative phase between the two polarization components. A phase stability of σ = 31.9 mrad (λ/197) over nearly 24 hours was measured by employing OPRAS. Various pulse sequences exceeding the capabilities of conventional pulse shapers were generated and characterized. The experimental results proved that shaped pulses with arbitrary phase, amplitude, and polarization states can be created. In all cases very high agreement between the target parameters and the experimental data was achieved. For the future use of the setup also possible modifications were suggested. These are not strictly required, but all of them could further improve the performance and flexibility of the setup. Firstly, it was illustrated how a "dual-output" of the setup can be realized. With this modification it would be possible to use the main intensity of the shaped pulse for an experiment while using a small fraction to characterize the pulse or to perform OPRAS simultaneously. Secondly, the basic idea of replacing the telescope by focusing mirrors in order to eliminate the chromatic aberrations was presented. Regarding the different parameterizations for vector-field shaping, some modifications increasing the flexibility of the implemented bases and the realization of a von Neumann Basis for the presented setup were proposed. In future experiments, the vector-field shaper will be used in conjunction with a photoemission electron microscope (PEEM). This approach combines the temporal resolution provided by ultrashort laser pulses with the high spatial resolution gained by electron microscopy in order to perform two-dimensional spectroscopy and coherent control on nanostructures with polarization-shaped femtosecond laser pulses. In combination with other chiral-sensitive experimental setups implemented earlier in our group, the vector-field shaper opens up new perspectives for chiral femtochemistry and chiral control. The designed vector-field shaper meets all requirements to generate high-precision polarization-shaped multipulse sequences. These can be used to perform numerous polarization-sensitive experiments. Employing the OPRAS routine, a quasi-infinitely long phase stability is achieved and complex and elaborated long-term measurements can be carried out. The fact that OPRAS demands no additional hardware and that only a single dual-layer LC SLM and inexpensive optics are required allows the building of a vector-field shaper at comparatively low costs. We hope that with the detailed insights into the optical design process as well as into the software implementation given in this thesis, vector-field shaping will become a standard technique just as conventional pulse shaping in the upcoming years.}, subject = {Ultrakurzer Lichtimpuls}, language = {en} } @phdthesis{Muenzhuber2015, author = {M{\"u}nzhuber, Franz}, title = {Magnetometrie mit Diamant}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-127601}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {Gegenstand der Arbeit ist die Magnetometrie mit Stickstoff-Fehlstellen-Zentren im Diamantgitter und die Entwicklung eines Rastersondenmagnetometers auf Basis eines Ensembles dieser Defektzentren. Ein solches Instrument verspricht eine bislang nicht erreichte Kombination von Feldsensitivit{\"a}t und r{\"a}umlicher Aufl{\"o}sung w{\"a}hrend einer Magnetfeldmessung, und kann damit einen wichtigen Beitrag f{\"u}r das Verst{\"a}ndnis von magnetischen Systemen und Ph{\"a}nomenen liefern. Die Arbeit widmet sich zun{\"a}chst dem Verst{\"a}ndnis der elektronischen Zust{\"a}nde des Defekts, und wie diese optisch untersucht werden k{\"o}nnen. Gleichzeitige Anregung der Zentren durch sichtbares Licht und elektromagnetischer Strahlung im Bereich von Mikrowellenfrequenzen machen es m{\"o}glich, die elektronische Spinstruktur des Defekts zu messen und zu manipulieren. Dadurch kann direkt der Einfluss von externen Magnetfeldern auf die Energie der Spinzust{\"a}nde ausgelesen werden. Die quantenmechanischen Auswahlregeln der verschiedenen Anregungen k{\"o}nnen f{\"u}r eine selektive Anregung der Zentren entlang einer bestimmten kristallographischen Achse verwendet werden. Damit kann eine Ensemble von Defekten zur Vektormagnetometrie, ohne auf ein zus{\"a}tzliches {\"a}ußeres Magnetfeld angewiesen zu sein, welches die untersuchte Probe nachhaltig beeinflussen kann. Anschließend wird die Entwicklung einer geeigneten Mikrowellenantenne dargestellt, die in einem sp{\"a}teren Rastersondenexperiment mit den Defekten auf geringem Raum eingesetzt werden kann. Außerdem werden die einzelnen Schritte pr{\"a}sentiert, wie die Farbzentren im Diamantgitter erzeugt werden und aus großen Diamantpl{\"a}ttchen Nanostrukturen erzeugt werden, die als Rasterkraftsonden eingesetzt werden k{\"o}nnen. Die fertigen Sonden k{\"o}nnen in einem modularen Rasterkraftaufbau verwendet werden, der {\"u}ber einen zus{\"a}tzlichen optischen Zugang verf{\"u}gt, sodass die Information des Spinsensors ausgelesen werden kann. In verschiedenen Testexperimenten wird die Funktionsweise des gesamten Apparats demonstriert.}, subject = {Diamant}, language = {de} } @phdthesis{Triphan2015, author = {Triphan, Simon}, title = {T1 und T2*-Quantifizierung in der menschlichen Lunge}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-139621}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {In dieser Arbeit werden f{\"u}r die Anwendung in der menschlichen Lunge optimierte Methoden zur Bestimmung von T1- und T2*-Karten diskutiert: Dc-Gating erm{\"o}glicht die Quantifizierung in freier Atmung, wobei f{\"u}r die T1-Quantifizierung mittels Inversion Recovery eine Korrektur des dc-Signals entwickelt wurde. Dies hat den Vorteil, dass Parameterkarten aus mehreren Messungen anhand ihrer dc-Signale passend {\"u}berlagert werden k{\"o}nnen. Da T1 und T2* auf unterschiedliche Art und Weise von der Sauerstoffkonzentration abh{\"a}ngen, verbessert dies die M{\"o}glichkeit, ΔT1- und ΔT2*- Differenzkarten aus Messungen mit unterschiedlichen O2-Konzentrationen im Atemgas zu erstellen. Die Parameterquantifizierung ist in erster Linie f{\"u}r die Beobachtung von Krankheitsverl{\"a}ufen interessant, da T1 und T2* absolute, vergleichbare Zahlen sind. Da T2* deutlich vom Atemzustand abh{\"a}ngt, ist es auch hierf{\"u}r sinnvoll, durch Gating identische Atemzust{\"a}nde abzubilden. Um die unterschiedlichen Einfl{\"u}sse des Sauerstoffs auf T1 und T2* besser vergleichbar zu machen, wurde in dieser Arbeit weiterhin eine kombinierte Messung f{\"u}r beide Parameter implementiert: Da auch diese in freier Atmung stattfindet, profitieren nicht nur die Differenzkarten von der {\"U}berlagerung der Bilder, sondern auch der Vergleich der ΔT1- und ΔT2*-Karten untereinander. Messungen mit einer konventionellen kartesischen Methode an COPD-Patienten unter Raumluft- und 100\% Sauerstoffatmung ergaben bei Verwendung identischer Atemmasken ein deutlich geringeres ΔT1 als in gesunden Probanden. Dass T1 in der Lunge nicht nur von der Sauerstoffkonzentration sondern auch von der Gewebezusammensetzung und insbesondere auch dem Blutvolumenanteil abh{\"a}ngt, zeigte sich hierbei aber auch an den bei COPD im Mittel sehr viel k{\"u}rzeren T1-Zeiten bei Raumluft. Die aufgrund emphysematischer Ver{\"a}nderung noch zus{\"a}tzlich reduzierte Protonendichte im Parenchym kranker Lungen macht diese Messungen allerdings besonders schwierig. Die oben erw{\"a}hnten Optimierungen der T1-Quantifizierung zielen daher auch darauf ab, das Signal aus der Lunge zu maximieren, um Patientenmessungen einfacher zu machen: Messungen in freier Atmung sind f{\"u}r Patienten nicht nur einfacher, sondern erlauben effektiv auch l{\"a}ngere Messzeiten. Insbesondere wurde aber durch die Entwicklung einer radialen Methode die Echozeit zur Messung reduziert, um die kurze T2*-Zeit in der Lunge auszugleichen. Schließlich wurde durch Implementation einer 2D UTE Sequenz die Messung bei der k{\"u}rzesten vom Scanner erlaubten Echozeit erm{\"o}glicht. Die Messungen bei ultrakurzen Echozeiten in Probanden zeigten allerdings deutlich k{\"u}rzere T1-Zeiten als die zuvor gefundenen oder in der Literatur dokumentierten. In weiteren Experimenten wurde das sichtbare T1 zu mehreren Echozeiten mit Hilfe der zur kombinierten Quantifizierung entwickelten Methode bestimmt. Dabei ergab sich eine Zunahme des gemessenen T1 mit der Echozeit. Aus diesem Verhalten sowie den gefundenen k{\"u}rzesten und l{\"a}ngsten T1 l{\"a}sst sich schließen, dass das intra- und extravaskul{\"a}re Lungenwasser, also Blut bzw. das umgebende Gewebe, mit unterschiedlichen T1- und T2*-Zeiten zum Signal und damit auch dem effektiven T1 beitragen. Dass das TE der Messung die Gewichtung dieser Kompartimente bestimmt, hat dabei mehrere Auswirkungen: Einerseits bedeutet dies, dass beim Vergleich von T1-Messungen in der Lunge stets auch das TE mitbetrachtet werden muss, bei dem diese durchgef{\"u}hrt wurden. Andererseits l{\"a}sst sich die M{\"o}glichkeit, die Messung auf die unterschiedlichen Kompartimente abzustimmen, potentiell ausnutzen, um zus{\"a}tzliche diagnostische Informationen zu gewinnen: Da T1 vom Blutvolumenanteil und der Gewebezusammensetzung abh{\"a}ngt, k{\"o}nnte dieser Effekt helfen, diese beiden Einfl{\"u}sse zu differenzieren. W{\"a}hrend die in dieser Arbeit beschriebenen Experimente die TE-Abh{\"a}ngigkeit des sichtbaren T1 in Probanden aufzeigen, liefern sie allerdings noch keine genaue Erkl{\"a}rung f{\"u}r die m{\"o}glichen Urspr{\"u}nge dieses Effekts. Um diese weiter zu untersuchen, k{\"o}nnten allerdings gezielte Phantom- und in vivo-Experimente Aufschluss geben: Ein Aufbau, der die Feldverzerrung durch luftgef{\"u}llte Alveolen in L{\"o}sungen mit entsprechenden verschiedenen Suszeptibilit{\"a}ten nachbildet, reduziert den Unterschied zwischen den Kompartimenten auf T1 und χ. Eine in vivo-Messung mit m{\"o}glichst großer Differenz zwischen Ex- und Inspiration hingegen k{\"o}nnte den Einfluss der Abst{\"a}nde der Kompartimente vom Gasraum aufzeigen, da die Alveolarw{\"a}nde in tiefer Inspiration am weitesten gedehnt und daher am d{\"u}nnsten sind.}, subject = {Kernspintomografie}, language = {de} } @phdthesis{Muehlbauer2015, author = {M{\"u}hlbauer, Mathias Josef}, title = {Nanolithography on Mercury Telluride}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-137152}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {Topological insulators belong to a new quantum state of matter that is currently one of the most recognized research fields in condensed matter physics. Strained bulk HgTe and HgTe/HgCdTe quantum well structures are currently one of few topological insulator material systems suitable to be studied in transport experiments. In addition HgTe quantum wells provide excellent requirements for the conduction of spintronic experiments. A fundamental requirement for most experiments, however, is to reliably pattern these heterostructures into advanced nano-devices. Nano-lithography on this material system proves to be challenging because of inherent temperature limitations, its high reactivity with various metals and due to its properties as a topological insulator. The current work gives an insight into why many established semiconductor lithography processes cannot be easily transferred to HgTe while providing alternative solutions. The presented developments include novel ohmic contacts, the prevention of metal sidewalls and redeposition fences in combination with low temperature (80 °C) lithography and an adapted hardmask lithography process utilizing a sacrificial layer. In addition we demonstrate high resolution low energy (2.5 kV) electron beam lithography and present an alternative airbridge gating technique. The feasibility of nano-structures on HgTe quantum wells is exemplarily verified in two separate transport experiments. We are first to realize physically etched quantum point contacts in HgTe/HgCdTe high mobility 2DEGs and to prove their controllability via external top-gate electrodes. So far quantum point contacts have not been reported in TI materials. However, these constrictions are part of many proposals to probe the nature of the helical quantum spin Hall edge channels and are suggested as injector and detector devices for spin polarized currents. To confirm their functionality we performed four-terminal measurements of the point contact conductance as a function of external gate voltage. Our measurements clearly exhibit quantized conductance steps in 2e2/h, which is a fundamental characteristic of quantum point contacts. Furthermore we conducted measurements on the formation and control of collimated electron beams, a key feature to realize an all electrical spin-optic device. In a second study several of the newly developed lithography techniques were implemented to produce arrays of nano-wires on inverted and non-inverted HgTe quantum well samples. These devices were used in order to probe and compare the weak antilocalization (WAL) in these structures as a function of magnetic field and temperature. Our measurements reveal that the WAL is almost an order of magnitude larger in inverted samples. This observation is attributed to the Dirac-like dispersion of the energy bands in HgTe quantum wells. The described lithography has already been successfully implemented and adapted in several published studies. All processes have been optimized to guarantee a minimum effect on the heterostructure's properties and the sample surface, which is especially important for probing the topological surface states of strained HgTe bulk layers. Our developments therefore serve as a base for continuous progress to further establish HgTe as a topological insulator and give access to new experiments.}, subject = {Topologischer Isolator}, language = {en} } @phdthesis{Bachschmidt2015, author = {Bachschmidt, Theresa}, title = {Magnetic Resonance Imaging in Proximity to Metal Implants at 3 Tesla}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-135690}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {Magnetic resonance imaging is derogated by the presence of metal implants and image quality is impaired. Artifacts are categorized according to their sources, the differences in susceptibility between metal and tissue and the modulation of the magnetic radiofrequency (RF) transmit field. Generally, these artifacts are intensified at higher field strength. The purpose of this work is to analyze the efficiency of current methods used for metal artifact reduction at 3T and to investigate improvements. The impact of high-bandwidth RF pulses on susceptibility-induced artifacts is tested. In addition, the benefit of a two-channel transmit system with respect to shading close to total hip replacements and other elongated metal structures in parallel to the magnetic field is analyzed. Local transmit/receive coils feature a higher peak B1 amplitude than conventional body coils and thus enable high-bandwidth RF pulses. Susceptibility-induced through-plane distortion relates reciprocally to the RF bandwidth, which is evaluated in vitro for a total knee arthroplasty. Clinically relevant sequences (TSE and SEMAC) with conventional and high RF pulse bandwidths and different contrasts are tested on eight patients with different types of knee implants. Distortion is rated by two radiologists. An additional analysis assesses the capability of a local spine transmit coil. Furthermore, B1 effects close to elongated metal structures are described by an analytical model comprising a water cylinder and a metal rod, which is verified numerically and experimentally. The dependence of the optimal polarization of the transmit B1 field, creating minimum shading, on the position of the metal is analyzed. In addition, the optimal polarization is determined for two patients; its benefit compared to circular polarization is assessed. Phantom experiments confirm the relation of the RF bandwidth and the through-plane distortion, which can be reduced by up to 79\% by exploitation of a commercial local transmit/receive knee coil at 3T. On average, artifacts are rated "hardly visible" for patients with joint arthroplasties, when high-bandwidth RF pulses and SEMAC are used, and for patients with titanium fixtures, when high-bandwidth RF pulses are used in combination with TSE. The benefits of the local spine transmit coil are less compared to the knee coil, but enable a bandwidth 3.9 times as high as the body coil. The modulation of B1 due to metal is approximated well by the model presented and the position of the metal has strong influence on this effect. The optimal polarization can mitigate shading substantially. In conclusion, through-plane distortion and related artifacts can be reduced significantly by the application of high-bandwidth RF pulses by local transmit coils at 3T. Parallel transmission offers an option to substantially reduce shading close to long metal structures aligned with the magnetic field. Effective techniques dedicated for metal implant imaging at 3T are introduced in this work.}, subject = {Kernspintomografie}, language = {en} } @phdthesis{Bieker2015, author = {Bieker, Steffen}, title = {Time and Spatially Resolved Photoluminescence Spectroscopy of Hot Excitons in Gallium Arsenide}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-134419}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {The present thesis investigates the impact of hot exciton effects on the low-temperature time and spatially resolved photoluminescence (PL) response of free excitons in high-purity gallium arsenide (GaAs). The work at hand extends available studies of hot carrier effects, which in bulk GaAs have up to now focused on hot electron populations. In crucial distinction from previous work, we extensively study the free exciton second LO-phonon replica. The benefit of this approach is twofold. First, the two LO phonon-assisted radiative recombination allows to circumvent the inherent interpretation ambiguities of the previously investigated free exciton zero-phonon line. Second, the recombination line shape of the second LO-phonon replica provides direct experimental access to the exciton temperature, thereby enabling the quantitative assessment of hot exciton effects. In the first part of the thesis, we address the influence of transient cooling on the time evolution of an initially hot photocarrier ensemble. To this end, we investigate time-resolved photoluminescence (TRPL) signals detected on the free exciton second LO-phonon replica. Settling a long-standing question, we show by comparison with TRPL transients of the free exciton zero-phonon line that the slow free exciton photoluminescence rise following pulsed optical excitation is dominated by the slow buildup of a free exciton population and not by the relaxation of large K-vector excitons to the Brillouin zone center. To establish a quantitative picture of the delayed photoluminescence onset, we determine the cooling dynamics of the initially hot photocarrier cloud from a time-resolved line shape analysis of the second LO-phonon replica. We demonstrate that the Saha equation, which fundamentally describes the thermodynamic population balance between free excitons and the uncorrelated electron-hole plasma, directly translates the experimentally derived cooling curves into the time-dependent conversion of unbound electron-hole pairs into free excitons. In the second part of the thesis, we establish the impact of hot exciton effects on low-temperature spatially resolved photoluminescence (SRPL) studies. Such experiments are widely used to investigate charge carrier and free exciton diffusion in semiconductors and semiconductor nanostructures. By SRPL spectroscopy of the second LO-phonon replica, we show that above-band gap focused laser excitation inevitably causes local heating in the carrier system, which crucially affects the diffusive expansion of a locally excited exciton packet. Undistorted free exciton diffusion profiles, which are correctly described by the commonly used formulation of the photocarrier diffusion equation, are only observed in the absence of spatial temperature gradients. At low sample temperatures, the reliable determination of free exciton diffusion coefficients from both continuous-wave and time-resolved SRPL spectroscopy requires strictly resonant optical excitation. Using resonant laser excitation, we observe the dimensional crossover of free exciton diffusion in etched wire structures of a thin, effectively two-dimensional GaAs epilayer. When the lateral wire width falls below the diffusion length, the sample geometry becomes effectively one-dimensional. The exciton diffusion profile along the wire stripe is then consistently reproduced by the steady-state solution to the one-dimensional diffusion equation. Finally, we demonstrate the formation of macroscopic free and bound exciton photoluminescence rings in bulk GaAs around a focused laser excitation spot. Both ring formation effects are due to pump-induced local heating in the exciton system. For a quantitative assessment of the mechanism underlying the free exciton ring formation, we directly determine the exciton temperature gradient from a spatially resolved line shape analysis of the free exciton second LO-phonon replica. We demonstrate that a pump-induced hot spot locally modifies the thermodynamic population balance between free excitons and unbound electron-hole pairs described by the Saha equation, which naturally explains the emergence of macroscopic free exciton ring structures. In summary, we demonstrate that quantitative consideration of hot exciton effects provides a coherent picture both of the time-domain free exciton luminescence kinetics and of the distinct spatially resolved photoluminescence patterns developing under the influence of spatial photocarrier diffusion.}, subject = {Exziton}, language = {en} } @phdthesis{Ott2015, author = {Ott, Martin}, title = {Lautst{\"a}rkereduzierte Magnetresonanztomographie}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-133921}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {Messungen mit Magnetresonanztomographen sind seit jeher mit hohen Lautst{\"a}rken verbunden. Deshalb wird das Ger{\"a}t im Volksmund auch als „laute R{\"o}hre" bezeichnet. Bisher wurde das Problem mit Kopfh{\"o}rern, Ohrenst{\"o}pseln und akustischer D{\"a}mmung des MRT-Scanners angegangen. Auch in der Fachliteratur wird das Problem als gegeben angesehen und es werden kaum wissenschaftliche L{\"o}sungsans{\"a}tze zur Lautst{\"a}rkereduktion beschrieben. Das Ziel der vorliegenden Arbeit war es, Bildgebungs-Sequenzen f{\"u}r schwer‑optimierbare Bildkontraste und sogenannte Standard-Kontraste aus dem klinischen Umfeld hinsichtlich der Lautst{\"a}rke zu optimieren. Viele dieser Kontraste k{\"o}nnen bereits mit einfachen Algorithmen wie dem Gradientengl{\"a}ttungsalgorithmus erfolgreich in Hinblick auf die Lautst{\"a}rke optimiert werden. Allerdings existieren auch Sequenzen beziehungsweise Kontraste, die aufgrund ihrer Eigenschaften nicht von einem solchen Algorithmus profitieren k{\"o}nnen. Die Optimierungen und {\"A}nderungen sollten software-seitig erfolgen, das heißt durch {\"A}nderung der Gradientenformen und Datenakquisition. In der Arbeit wurden die grundlegenden Zusammenh{\"a}nge zwischen den verwendeten Ger{\"a}teparametern und der Lautst{\"a}rke untersucht und zudem die physikalischen Ursachen der Lautst{\"a}rkeentwicklung hergeleitet. Diese konnten anhand der Lorentz-Kr{\"a}fte quantitativ beschrieben werden. Somit konnten die Hauptursachen der Lautst{\"a}rkeentwicklung identifiziert werden. Diese sind abh{\"a}ngig von der Gradienten-Steig-Rate, aber auch von der Amplitude der Gradienten. Es konnte gezeigt werden, dass eine Minimierung dieser Gradientenparameter zu einer geringeren Lautst{\"a}rkeentwicklung f{\"u}hrt. Allerdings f{\"u}hrt diese Minimierung in den meisten F{\"a}llen auch zu einer systematischen Verlangsamung des Sequenzablaufs, was das Erreichen bestimmter Echozeiten und Bildkontraste unm{\"o}glich macht. Zu den problematischen Kontrasten bez{\"u}glich der Lautst{\"a}rkereduktion z{\"a}hlten der T1- und PD‑Kontrast einer Turbo-Spin-Echo-Sequenz. Durch die Kombination von mehreren Maßnahmen, wie der Adaption der k-Raum-Akquisition, der HF-Pulse-Parameter und den Gradientenformen, war es m{\"o}glich, die Lautst{\"a}rke in Beispielmessungen um bis zu 16,8 dB(A) zu reduzieren. Wie bei der k{\"u}rzlich ver{\"o}ffentlichten Methode zur Reduktion f{\"u}r die T2‑gewichteten Kontraste, wurde dies zulasten einer Messzeitverl{\"a}ngerung von bis zu 50\% erreicht. Die Endlautst{\"a}rke betrug dabei circa 81 dB(A). Mit der Lautst{\"a}rkeoptimierung der klinisch bedeutsamen T1- und PD‑Kontraste wurde die Palette an leisen, mit der Turbo-Spin-Echo‑Sequenz erzielbaren, Standard-Kontrasten (T1, T2 und PD) nun vervollst{\"a}ndigt. In einem anderen Ansatz wurde die Anwendbarkeit des CAT-Konzepts auf die Lautst{\"a}rkereduktion untersucht. Beim CAT-Konzept wird die Messung in Einzelmessungen mit verschiedenen Parametern unterteilt. Bisher wurde dieser Ansatz zur SAR-Reduktion verwendet. Das Zentrum des k-Raums wird mit einer SAR-intensiven, kontrastgebenden Messung aufgenommen. Der verbleibende Teil des k-Raums wird mit einer SAR-reduzierten, bildstrukturrelevanten Messung aufgenommen. In dieser Arbeit wurde die {\"U}bertragung des CAT-Konzepts auf die Lautst{\"a}rkereduktion untersucht. Anstelle von SAR-intensiven und SAR‑reduzierten Messungen, wurde hier die Unterteilung in „laute" und „leise" Messungen untersucht. Dabei wurden {\"U}berlegungen angestellt, die es f{\"u}r eine Vielzahl an Messungen erm{\"o}glichen, einen großen Teil der Messung leise zu gestalten ohne die Bildqualit{\"a}t oder den Bildkontrast zu ver{\"a}ndern. In einem weiteren Schritt wurden {\"U}berlegungen f{\"u}r die Lautst{\"a}rkereduktion der lauten Messungen vorgestellt. Anschließend wurden f{\"u}r eine GRE- und TSE-Sequenz Optimierungsschritte evaluiert und die Lautst{\"a}rke gemessen. Der hinsichtlich der Lautst{\"a}rkeoptimierung herausforderndste Bildkontrast ist die diffusionsgewichtete Bildgebung. Diese besitzt eine Diffusions-Pr{\"a}paration zur Sichtbarmachung der Diffusivit{\"a}t, bei der die maximal m{\"o}gliche Gradienten-Amplitude verwendet wird. Ebenso werden nach der Pr{\"a}paration die Daten mit einem EPI‑Akquisitionsmodul mit Blip-Gradienten akquiriert, das mit einem charakteristischem „Pfeifton" einhergeht. Zum einen wurden die Gradientenformen konsequent angepasst. Zum anderen wurde eine Segmentierung der k-Raum-Akquisition in Auslese-Richtung verwendet, um die Gradienten‑Steig-Raten zu reduzieren. Auch hier konnte eine deutliche Lautst{\"a}rkereduktion von bis zu 20,0 dB(A) erzielt werden. Dies wurde zulasten einer Messzeitverl{\"a}ngerung von 27\% ‑ 34\% im Vergleich zur Standard-Sequenz erreicht. Durch eine weitere Messzeitverl{\"a}ngerung um bis zu 23\% kann die Lautst{\"a}rke um weitere 0,9 dB(A) reduziert werden. Dabei h{\"a}ngt die genaue Messzeitverl{\"a}ngerung vom verwendeten GRAPPA-Faktor und der Anzahl der Auslese-Segmente ab. Die entstandene Sequenz wurde in mehreren Kliniken erfolgreich erprobt. Bisher mussten bei MRT-Messungen stets Kompromisse zwischen „hoher Aufl{\"o}sung", „hohem SNR" und „geringer Messzeit" getroffen werden. Als Anschauung daf{\"u}r wurde das „Bermuda‑Dreieck der MRT" eingef{\"u}hrt. Da alle drei Gr{\"o}ßen sich gegenseitig ausschließen, muss stets ein Mittelweg gefunden werden. Einige der in dieser Arbeit erzielten Erfolge bei der Lautst{\"a}rkereduktion wurden auf Kosten einer verl{\"a}ngerten Messzeit erreicht. Daher ist es naheliegend, das „Bermuda-Dreieck der MRT" um die Dimension der „geringen Lautst{\"a}rke" zu einer „Bermuda-Pyramide der MRT" zu erweitern. Damit muss die Lautst{\"a}rkeentwicklung in die Mittelweg‑Findung miteinbezogen werden. Die in dieser Arbeit erzielten Lautst{\"a}rken liegen in der Gr{\"o}ßenordnung zwischen 80 ‑ 85 dB(A). Somit k{\"o}nnen Messungen bei Verwendung von Geh{\"o}rschutz angenehm f{\"u}r den Patienten durchgef{\"u}hrt werden. Durch neue Techniken der Zukunft wird es wahrscheinlich sein, h{\"o}here Aufl{\"o}sungen, h{\"o}heres SNR oder k{\"u}rzere Aufnahmedauern zu erzielen, beziehungsweise stattdessen diese in eine geringe Lautst{\"a}rke „umzuwandeln". Ebenso werden m{\"o}glicherweise auf der hardware-technischen Seite Fortschritte erzielt werden, so dass in neueren MRT-Scannergenerationen mehr Wert auf die L{\"a}rmd{\"a}mmung gelegt wird und somit der softwarebasierten Lautst{\"a}rkereduktion einen Schritt entgegen gekommen wird. Damit k{\"o}nnten zuk{\"u}nftige Patienten-Messungen g{\"a}nzlich ohne st{\"o}renden Geh{\"o}rschutz durchgef{\"u}hrt werden.}, subject = {Kernspintomografie}, language = {de} }