@article{ChenWernerKoshinoetal.2022, author = {Chen, Xinyu and Werner, Rudolf A. and Koshino, Kazuhiro and Nose, Naoko and M{\"u}hlig, Saskia and Rowe, Steven P. and Pomper, Martin G. and Lapa, Constantin and Decker, Michael and Higuchi, Takahiro}, title = {Molecular Imaging-Derived Biomarker of Cardiac Nerve Integrity - Introducing High NET Affinity PET Probe \(^{18}\)F-AF78}, series = {Theranostics}, volume = {12}, journal = {Theranostics}, number = {9}, doi = {10.7150/thno.63205}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300685}, pages = {4446 -- 4458}, year = {2022}, abstract = {Background: Radiolabeled agents that are substrates for the norepinephrine transporter (NET) can be used to quantify cardiac sympathetic nervous conditions and have been demonstrated to identify high-risk congestive heart failure (HF) patients prone to arrhythmic events. We aimed to fully characterize the kinetic profile of the novel \(^{18}\)F-labeled NET probe AF78 for PET imaging of the cardiac sympathetic nervous system (SNS) among various species. Methods: \(^{18}\)F-AF78 was compared to norepinephrine (NE) and established SNS radiotracers by employing in vitro cell assays, followed by an in vivo PET imaging approach with healthy rats, rabbits and nonhuman primates (NHPs). Additionally, chase protocols were performed in NHPs with NET inhibitor desipramine (DMI) and the NE releasing stimulator tyramine (TYR) to investigate retention kinetics in cardiac SNS. Results: Relative to other SNS radiotracers, 18F-AF78 showed higher transport affinity via NET in a cell-based competitive uptake assay (IC\(^{50}\) 0.42 ± 0.14 µM), almost identical to that of NE (IC\(^{50}\), 0.50 ± 0.16 µM, n.s.). In rabbits and NHPs, initial cardiac uptake was significantly reduced by NET inhibition. Furthermore, cardiac tracer retention was not affected by a DMI chase protocol but was markedly reduced by intermittent TYR chase, thereby suggesting that \(^{18}\)F-AF78 is stored and can be released via the synaptic vesicular turnover process. Computational modeling hypothesized the formation of a T-shaped π-π stacking at the binding site, suggesting a rationale for the high affinity of \(^{18}\)F-AF78. Conclusion: \(^{18}\)F-AF78 demonstrated high in vitro NET affinity and advantageous in vivo radiotracer kinetics across various species, indicating that \(^{18}\)F-AF78 is an SNS imaging agent with strong potential to guide specific interventions in cardiovascular medicine.}, language = {en} } @article{WernerHabachaLuetjeetal.2022, author = {Werner, Rudolf A. and Habacha, Bil{\^e}l and L{\"u}tje, Susanne and Bundschuh, Lena and Higuchi, Takahiro and Hartrampf, Philipp and Serfling, Sebastian E. and Derlin, Thorsten and Lapa, Constantin and Buck, Andreas K. and Essler, Markus and Pienta, Kenneth J. and Eisenberger, Mario A. and Markowski, Mark C. and Shinehouse, Laura and AbdAllah, Rehab and Salavati, Ali and Lodge, Martin A. and Pomper, Martin G. and Gorin, Michael A. and Bundschuh, Ralph A. and Rowe, Steven P.}, title = {High SUVs Have More Robust Repeatability in Patients with Metastatic Prostate Cancer: Results from a Prospective Test-Retest Cohort Imaged with \(^{18}\)F-DCFPyL}, series = {Molecular Imaging}, volume = {2022}, journal = {Molecular Imaging}, doi = {10.1155/2022/7056983}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300748}, year = {2022}, abstract = {No abstract available.}, language = {en} } @article{MatsusakaWernerAriasLozaetal.2022, author = {Matsusaka, Yohji and Werner, Rudolf A. and Arias-Loza, Paula and Nose, Naoko and Sasaki, Takanori and Chen, Xinyu and Lapa, Constantin and Higuchi, Takahiro}, title = {Performance Evaluation of a Preclinical SPECT Scanner with a Collimator Designed for Medium-Sized Animals}, series = {Molecular Imaging}, volume = {2022}, journal = {Molecular Imaging}, doi = {10.1155/2022/9810097}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300713}, year = {2022}, abstract = {Background. Equipped with two stationary detectors, a large bore collimator for medium-sized animals has been recently introduced for dedicated preclinical single-photon emission computed tomography (SPECT) imaging. We aimed to evaluate the basic performance of the system using phantoms and healthy rabbits. Methods. A general-purpose medium-sized animal (GP-MSA) collimator with 135 mm bore diameter and thirty-three holes of 2.5 mm diameter was installed on an ultrahigh-resolution scanner equipped with two large stationary detectors (U-SPECT5-E/CT). The sensitivity and uniformity were investigated using a point source and a cylinder phantom containing 99mTc-pertechnetate, respectively. Uniformity (in \%) was derived using volumes of interest (VOIs) on images of the cylinder phantom and calculated as , with lower values of \% indicating superior performance. The spatial resolution and contrast-to-noise ratios (CNRs) were evaluated with images of a hot-rod Derenzo phantom using different activity concentrations. Feasibility of in vivo SPECT imaging was finally confirmed by rabbit imaging with the most commonly used clinical myocardial perfusion SPECT agent [99mTc]Tc-sestamibi (dynamic acquisition with a scan time of 5 min). Results. In the performance evaluation, a sensitivity of 790 cps/MBq, a spatial resolution with the hot-rod phantom of 2.5 mm, and a uniformity of 39.2\% were achieved. The CNRs of the rod size 2.5 mm were 1.37, 1.24, 1.20, and 0.85 for activity concentration of 29.2, 1.0, 0.5, and 0.1 MBq/mL, respectively. Dynamic SPECT imaging in rabbits allowed to visualize most of the thorax and to generate time-activity curves of the left myocardial wall and ventricular cavity. Conclusion. Preclinical U-SPECT5-E/CT equipped with a large bore collimator demonstrated adequate sensitivity and resolution for in vivo rabbit imaging. Along with its unique features of SPECT molecular functional imaging is a superior collimator technology that is applicable to medium-sized animal models and thus may promote translational research for diagnostic purposes and development of novel therapeutics.}, language = {en} } @article{SerflingLapaDreheretal.2022, author = {Serfling, Sebastian E. and Lapa, Constantin and Dreher, Niklas and Hartrampf, Philipp E. and Rowe, Steven P. and Higuchi, Takahiro and Schirbel, Andreas and Weich, Alexander and Hahner, Stefanie and Fassnacht, Martin and Buck, Andreas K. and Werner, Rudolf A.}, title = {Impact of tumor burden on normal organ distribution in patients imaged with CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT}, series = {Molecular Imaging and Biology}, volume = {24}, journal = {Molecular Imaging and Biology}, number = {4}, doi = {10.1007/s11307-022-01717-1}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324622}, pages = {659-665}, year = {2022}, abstract = {Background CXCR4-directed positron emission tomography/computed tomography (PET/CT) has been used as a diagnostic tool in patients with solid tumors. We aimed to determine a potential correlation between tumor burden and radiotracer accumulation in normal organs. Methods Ninety patients with histologically proven solid cancers underwent CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT. Volumes of interest (VOIs) were placed in normal organs (heart, liver, spleen, bone marrow, and kidneys) and tumor lesions. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were determined. For CXCR4-positive tumor burden, maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA, defined as SUV\(_{mean}\) x TV), were calculated. We used a Spearman's rank correlation coefficient (ρ) to derive correlative indices between normal organ uptake and tumor burden. Results Median SUV\(_{mean}\) in unaffected organs was 5.2 for the spleen (range, 2.44 - 10.55), 3.27 for the kidneys (range, 1.52 - 17.4), followed by bone marrow (1.76, range, 0.84 - 3.98), heart (1.66, range, 0.88 - 2.89), and liver (1.28, range, 0.73 - 2.45). No significant correlation between SUV\(_{max}\) in tumor lesions (ρ ≤ 0.189, P ≥ 0.07), TV (ρ ≥ -0.204, P ≥ 0.06) or FTA (ρ ≥ -0.142, P ≥ 0.18) with the investigated organs was found. Conclusions In patients with solid tumors imaged with [\(^{68}\)Ga]Ga-PentixaFor PET/CT, no relevant tumor sink effect was noted. This observation may be of relevance for therapies with radioactive and non-radioactive CXCR4-directed drugs, as with increasing tumor burden, the dose to normal organs may remain unchanged.}, language = {en} } @article{WeichHiguchiBundschuhetal.2022, author = {Weich, Alexander and Higuchi, Takahiro and Bundschuh, Ralph A. and Lapa, Constantin and Serfling, Sebastian E. and Rowe, Steven P. and Pomper, Martin G. and Herrmann, Ken and Buck, Andreas K. and Derlin, Thorsten and Werner, Rudolf A.}, title = {Training on reporting and data system (RADS) for somatostatin-receptor targeted molecular imaging can reduce the test anxiety of inexperienced readers}, series = {Molecular Imaging and Biology}, volume = {24}, journal = {Molecular Imaging and Biology}, number = {4}, doi = {10.1007/s11307-022-01712-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324645}, pages = {631-640}, year = {2022}, abstract = {Purpose For somatostatin receptor (SSTR)-positron emission tomography/computed tomography (PET/CT), a standardized framework termed SSTR-reporting and data system (RADS) has been proposed. We aimed to elucidate the impact of a RADS-focused training on reader's anxiety to report on SSTR-PET/CT, the motivational beliefs in learning such a system, whether it increases reader's confidence, and its implementation in clinical routine. Procedures A 3-day training course focusing on SSTR-RADS was conducted. Self-report questionnaires were handed out prior to the course (Pre) and thereafter (Post). The impact of the training on the following categories was evaluated: (1) test anxiety to report on SSTR-PET/CT, (2) motivational beliefs, (3) increase in reader's confidence, and (4) clinical implementation. To assess the effect size of the course, Cohen's d was calculated (small, d = 0.20; large effect, d = 0.80). Results Of 22 participants, Pre and Post were returned by 21/22 (95.5\%). In total, 14/21 (66.7\%) were considered inexperienced (IR, < 1 year experience in reading SSTR-PET/CTs) and 7/21 (33.3\%) as experienced readers (ER, > 1 year). Applying SSTR-RADS, a large decrease in anxiety to report on SSTR-PET/CT was noted for IR (d =  - 0.74, P = 0.02), but not for ER (d = 0.11, P = 0.78). For the other three categories motivational beliefs, reader's confidence, and clinical implementation, agreement rates were already high prior to the training and persisted throughout the course (P ≥ 0.21). Conclusions A framework-focused reader training can reduce anxiety to report on SSTR-PET/CTs, in particular for inexperienced readers. This may allow for a more widespread adoption of this system, e.g., in multicenter trials for better intra- and interindividual comparison of scan results.}, language = {en} } @article{MarquardtHartrampfKollmannsbergeretal.2023, author = {Marquardt, Andr{\´e} and Hartrampf, Philipp and Kollmannsberger, Philip and Solimando, Antonio G. and Meierjohann, Svenja and K{\"u}bler, Hubert and Bargou, Ralf and Schilling, Bastian and Serfling, Sebastian E. and Buck, Andreas and Werner, Rudolf A. and Lapa, Constantin and Krebs, Markus}, title = {Predicting microenvironment in CXCR4- and FAP-positive solid tumors — a pan-cancer machine learning workflow for theranostic target structures}, series = {Cancers}, volume = {15}, journal = {Cancers}, number = {2}, issn = {2072-6694}, doi = {10.3390/cancers15020392}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-305036}, year = {2023}, abstract = {(1) Background: C-X-C Motif Chemokine Receptor 4 (CXCR4) and Fibroblast Activation Protein Alpha (FAP) are promising theranostic targets. However, it is unclear whether CXCR4 and FAP positivity mark distinct microenvironments, especially in solid tumors. (2) Methods: Using Random Forest (RF) analysis, we searched for entity-independent mRNA and microRNA signatures related to CXCR4 and FAP overexpression in our pan-cancer cohort from The Cancer Genome Atlas (TCGA) database — representing n = 9242 specimens from 29 tumor entities. CXCR4- and FAP-positive samples were assessed via StringDB cluster analysis, EnrichR, Metascape, and Gene Set Enrichment Analysis (GSEA). Findings were validated via correlation analyses in n = 1541 tumor samples. TIMER2.0 analyzed the association of CXCR4 / FAP expression and infiltration levels of immune-related cells. (3) Results: We identified entity-independent CXCR4 and FAP gene signatures representative for the majority of solid cancers. While CXCR4 positivity marked an immune-related microenvironment, FAP overexpression highlighted an angiogenesis-associated niche. TIMER2.0 analysis confirmed characteristic infiltration levels of CD8+ cells for CXCR4-positive tumors and endothelial cells for FAP-positive tumors. (4) Conclusions: CXCR4- and FAP-directed PET imaging could provide a non-invasive decision aid for entity-agnostic treatment of microenvironment in solid malignancies. Moreover, this machine learning workflow can easily be transferred towards other theranostic targets.}, language = {en} } @article{TutovChenWerneretal.2023, author = {Tutov, Anna and Chen, Xinyu and Werner, Rudolf A. and M{\"u}hlig, Saskia and Zimmermann, Thomas and Nose, Naoko and Koshino, Kazuhiro and Lapa, Constantin and Decker, Michael and Higuchi, Takahiro}, title = {Rationalizing the binding modes of PET radiotracers targeting the norepinephrine transporter}, series = {Pharmaceutics}, volume = {15}, journal = {Pharmaceutics}, number = {2}, issn = {1999-4923}, doi = {10.3390/pharmaceutics15020690}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-303949}, year = {2023}, abstract = {Purpose: A new PET radiotracer \(^{18}\)F-AF78 showing great potential for clinical application has been reported recently. It belongs to a new generation of phenethylguanidine-based norepinephrine transporter (NET)-targeting radiotracers. Although many efforts have been made to develop NET inhibitors as antidepressants, systemic investigations of the structure-activity relationships (SARs) of NET-targeting radiotracers have rarely been performed. Methods: Without changing the phenethylguanidine pharmacophore and 3-fluoropropyl moiety that is crucial for easy labeling, six new analogs of \(^{18}\)F-AF78 with different meta-substituents on the benzene-ring were synthesized and evaluated in a competitive cellular uptake assay and in in vivo animal experiments in rats. Computational modeling of these tracers was established to quantitatively rationalize the interaction between the radiotracers and NET. Results: Using non-radiolabeled reference compounds, a competitive cellular uptake assay showed a decrease in NET-transporting affinity from meta-fluorine to iodine (0.42 and 6.51 µM, respectively), with meta-OH being the least active (22.67 µM). Furthermore, in vivo animal studies with radioisotopes showed that heart-to-blood ratios agreed with the cellular experiments, with AF78(F) exhibiting the highest cardiac uptake. This result correlates positively with the electronegativity rather than the atomic radius of the meta-substituent. Computational modeling studies revealed a crucial influence of halogen substituents on the radiotracer-NET interaction, whereby a T-shaped π-π stacking interaction between the benzene-ring of the tracer and the amino acid residues surrounding the NET binding site made major contributions to the different affinities, in accordance with the pharmacological data. Conclusion: The SARs were characterized by in vitro and in vivo evaluation, and computational modeling quantitatively rationalized the interaction between radiotracers and the NET binding site. These findings pave the way for further evaluation in different species and underline the potential of AF78(F) for clinical application, e.g., cardiac innervation imaging or molecular imaging of neuroendocrine tumors.}, language = {en} }