@article{HiguchiSerflingRoweetal.2022, author = {Higuchi, Takahiro and Serfling, Sebastian E. and Rowe, Steven P. and Werner, Rudolf A.}, title = {Therapeutic effects of lipid lowering medications on myocardial blood flow, inflammation, and sympathetic nerve activity using nuclear techniques}, series = {Current Cardiology Reports}, volume = {24}, journal = {Current Cardiology Reports}, number = {12}, doi = {10.1007/s11886-022-01792-4}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324599}, pages = {1849-1853}, year = {2022}, abstract = {Purpose of Review Statins are routinely applied in patients with coronary artery disease, as they allow significantly to reduce blood cholesterol levels. Although those drugs are endorsed by current guidelines and prescribed routinely, a substantial portion of patients are still statin-intolerant and image-piloted strategies may then be helpful to identify patients that need further intensified treatment, e.g., to initiate treatment with proprotein convertase subtilisin / kexin type 9 inhibitors (PCSK9i). In addition, it has also been advocated that statins exhibit nonlipid, cardio-protective effects including improved cardiac nerve integrity, blood flow, and anti-inflammatory effects in congestive heart failure (HF) patients. Recent Findings In subjects after myocardial infarction treated with statins, \(^{123}\)I-metaiodobenzylguanidine (MIBG) scintigraphy has already revealed enhanced cardiac nerve function relative to patients without statins. In addition, all of those aforementioned statin-targeted pathways in HF can be visualized and monitored using dedicated cardiac radiotracers, e.g., \(^{123}\)I-MIBG or \(^{18}\)F-AF78 (for cardiac nerve function), \(^{18}\)F-flurpiridaz (to determine coronary flow) or \(^{68}\)Ga-PentixaFor (to detect inflammation). Summary Statins exhibit various cardio-beneficial effects, including improvement of cardiac nerve function, blood flow, and reduction of inflammation, which can all be imaged using dedicated nuclear cardiac radiotracers. This may allow for in vivo monitoring of statin-induced cardioprotection beyond lipid profiling in HF patients.}, language = {en} } @article{HartrampfBundschuhWeinzierletal.2022, author = {Hartrampf, Philipp E. and Bundschuh, Ralph A. and Weinzierl, Franz-Xaver and Serfling, Sebastian E. and Kosmala, Aleksander and Seitz, Anna Katharina and K{\"u}bler, Hubert and Buck, Andreas K. and Essler, Markus and Werner, Rudolf A.}, title = {mCRPC patients with PSA fluctuations under radioligand therapy have comparable survival benefits relative to patients with sustained PSA decrease}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {49}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {13}, doi = {10.1007/s00259-022-05910-w}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324562}, pages = {4727-4735}, year = {2022}, abstract = {Introduction In men with metastatic castration-resistant prostate cancer (mCRPC) scheduled for prostate-specific membrane antigen (PSMA)-targeted radioligand therapy (RLT), biochemical response is assessed based on repeated measurements of prostate-specific antigen (PSA) levels. We aimed to determine overall survival (OS) in patients experiencing sustained PSA increase, decrease, or fluctuations during therapy. Materials and methods In this bicentric study, we included 176 mCRPC patients treated with PSMA-directed RLT. PSA levels were determined using blood samples prior to the first RLT and on the admission days for the following cycles. We calculated relative changes in PSA levels compared to baseline. Kaplan-Meier curves as well as log-rank test were used to compare OS of different subgroups, including patients with sustained PSA increase, decrease, or fluctuations (defined as change after initial decrease or increase after the first cycle). Results Sixty-one out of one hundred seventy-six (34.7\%) patients showed a sustained increase and 86/176 (48.8\%) a sustained decrease in PSA levels. PSA fluctuations were observed in the remaining 29/176 (16.5\%). In this subgroup, 22/29 experienced initial PSA decrease followed by an increase (7/29, initial increase followed by a decrease). Median OS of patients with sustained decrease in PSA levels was significantly longer when compared to patients with sustained increase of PSA levels (19 vs. 8 months; HR 0.35, 95\% CI 0.22-0.56; P < 0.001). Patients with PSA fluctuations showed a significantly longer median OS compared to patients with sustained increase of PSA levels (18 vs. 8 months; HR 0.49, 95\% CI 0.30-0.80; P < 0.01), but no significant difference relative to men with sustained PSA decrease (18 vs. 19 months; HR 1.4, 95\% CI 0.78-2.49; P = 0.20). In addition, in men experiencing PSA fluctuations, median OS did not differ significantly between patients with initial decrease or initial increase of tumor marker levels (16 vs. 18 months; HR 1.2, 95\% CI 0.38-4.05; P = 0.68). Conclusion Initial increase or decrease of PSA levels is sustained in the majority of patients undergoing RLT. Sustained PSA decrease was linked to prolonged survival and men with PSA fluctuations under treatment experienced comparable survival benefits. As such, transient tumor marker oscillations under RLT should rather not lead to treatment discontinuation, especially in the absence of radiological progression.}, language = {en} } @article{GoeringSchumannMuelleretal.2022, author = {G{\"o}ring, Lukas and Schumann, Sarah and M{\"u}ller, Jessica and Buck, Andreas K. and Port, Matthias and Lassmann, Michael and Scherthan, Harry and Eberlein, Uta}, title = {Repair of a-particle-induced DNA damage in peripheral blood mononuclear cells after internal ex vivo irradiation with \(^{223}\)Ra}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {49}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {12}, doi = {10.1007/s00259-022-05860-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324557}, pages = {3981-3988}, year = {2022}, abstract = {Purpose As α-emitters for radiopharmaceutical therapies are administered systemically by intravenous injection, blood will be irradiated by α-particles that induce clustered DNA double-strand breaks (DSBs). Here, we investigated the induction and repair of DSB damage in peripheral blood mononuclear cells (PBMCs) as a function of the absorbed dose to the blood following internal ex vivo irradiation with [\(^{223}\)Ra]RaCl2. Methods Blood samples of ten volunteers were irradiated by adding [\(^{223}\)Ra]RaCl2 solution with different activity concentrations resulting in absorbed doses to the blood of 3 mGy, 25 mGy, 50 mGy and 100 mGy. PBMCs were isolated, divided in three parts and either fixed directly (d-samples) or after 4 h or 24 h culture. After immunostaining, the induced γ-H2AX α-tracks were counted. The time-dependent decrease in α-track frequency was described with a model assuming a repair rate R and a fraction of non-repairable damage Q. Results For 25 mGy, 50 mGy and 100 mGy, the numbers of α-tracks were significantly increased compared to baseline at all time points. Compared to the corresponding d-samples, the α-track frequency decreased significantly after 4 h and after 24 h. The repair rates R were (0.24 ± 0.05) h-1 for 25 mGy, (0.16 ± 0.04) h-1 for 50 mGy and (0.13 ± 0.02) h-1 for 100 mGy, suggesting faster repair at lower absorbed doses, while Q-values were similar. Conclusion The results obtained suggest that induction and repair of the DSB damage depend on the absorbed dose to the blood. Repair rates were similar to what has been observed for irradiation with low linear energy transfer.}, language = {en} } @article{HartrampfSeitzWeinzierletal.2022, author = {Hartrampf, Philipp E. and Seitz, Anna Katharina and Weinzierl, Franz-Xaver and Serfling, Sebastian E. and Schirbel, Andreas and Rowe, Steven P. and K{\"u}bler, Hubert and Buck, Andreas K. and Werner, Rudolf A.}, title = {Baseline clinical characteristics predict overall survival in patients undergoing radioligand therapy with [\(^{177}\)Lu]Lu-PSMA I\&T during long-term follow-up}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {49}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {12}, doi = {10.1007/s00259-022-05853-2}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324573}, pages = {4262-4270}, year = {2022}, abstract = {Background Radioligand therapy (RLT) with \(^{177}\)Lu-labeled prostate-specific membrane antigen (PSMA) ligands is associated with prolonged overall survival (OS) in patients with advanced, metastatic castration-resistant prostate cancer (mCRPC). A substantial number of patients, however, are prone to treatment failure. We aimed to determine clinical baseline characteristics to predict OS in patients receiving [\(^{177}\)Lu]Lu-PSMA I\&T RLT in a long-term follow-up. Materials and methods Ninety-two mCRPC patients treated with [\(^{177}\)Lu]Lu-PSMA I\&T with a follow-up of at least 18 months were retrospectively identified. Multivariable Cox regression analyses were performed for various baseline characteristics, including laboratory values, Gleason score, age, prior therapies, and time interval between initial diagnosis and first treatment cycle (interval\(_{Diagnosis-RLT}\), per 12 months). Cutoff values for significant predictors were determined using receiver operating characteristic (ROC) analysis. ROC-derived thresholds were then applied to Kaplan-Meier analyses. Results Baseline C-reactive protein (CRP; hazard ratio [HR], 1.10, 95\% CI 1.02-1.18; P = 0.01), lactate dehydrogenase (LDH; HR, 1.07, 95\% CI 1.01-1.11; P = 0.01), aspartate aminotransferase (AST; HR, 1.16, 95\% CI 1.06-1.26; P = 0.001), and interval\(_{Diagnosis-RLT}\) (HR, 0.95, 95\% CI 0.91-0.99; P = 0.02) were identified as independent prognostic factors for OS. The following respective ROC-based thresholds were determined: CRP, 0.98 mg/dl (area under the curve [AUC], 0.80); LDH, 276.5 U/l (AUC, 0.83); AST, 26.95 U/l (AUC, 0.73); and interval\(_{Diagnosis-RLT}\), 43.5 months (AUC, 0.68; P < 0.01, respectively). Respective Kaplan-Meier analyses demonstrated a significantly longer median OS of patients with lower CRP, lower LDH, and lower AST, as well as prolonged interval\(_{Diagnosis-RLT}\) (P ≤ 0.01, respectively). Conclusion In mCRPC patients treated with [\(^{177}\)Lu]Lu-PSMA I\&T, baseline CRP, LDH, AST, and time interval until RLT initiation (thereby reflecting a possible indicator for tumor aggressiveness) are independently associated with survival. Our findings are in line with previous findings on [\(^{177}\)Lu]Lu-PSMA-617, and we believe that these clinical baseline characteristics may support the nuclear medicine specialist to identify long-term survivors.}, language = {en} } @article{BuckSerflingLindneretal.2022, author = {Buck, Andreas K. and Serfling, Sebastian E. and Lindner, Thomas and H{\"a}nscheid, Heribert and Schirbel, Andreas and Hahner, Stefanie and Fassnacht, Martin and Einsele, Hermann and Werner, Rudolf A.}, title = {CXCR4-targeted theranostics in oncology}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {49}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {12}, doi = {10.1007/s00259-022-05849-y}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324545}, pages = {4133-4144}, year = {2022}, abstract = {A growing body of literature reports on the upregulation of C-X-C motif chemokine receptor 4 (CXCR4) in a variety of cancer entities, rendering this receptor as suitable target for molecular imaging and endoradiotherapy in a theranostic setting. For instance, the CXCR4-targeting positron emission tomography (PET) agent [\(^{68}\)Ga]PentixaFor has been proven useful for a comprehensive assessment of the current status quo of solid tumors, including adrenocortical carcinoma or small-cell lung cancer. In addition, [\(^{68}\)Ga]PentixaFor has also provided an excellent readout for hematological malignancies, such as multiple myeloma, marginal zone lymphoma, or mantle cell lymphoma. PET-based quantification of the CXCR4 capacities in vivo allows for selecting candidates that would be suitable for treatment using the theranostic equivalent [\(^{177}\)Lu]/[\(^{90}\)Y]PentixaTher. This CXCR4-directed theranostic concept has been used as a conditioning regimen prior to hematopoietic stem cell transplantation and to achieve sufficient anti-lymphoma/-tumor activity in particular for malignant tissues that are highly sensitive to radiation, such as the hematological system. Increasing the safety margin, pretherapeutic dosimetry is routinely performed to determine the optimal activity to enhance therapeutic efficacy and to reduce off-target adverse events. The present review will provide an overview of current applications for CXCR4-directed molecular imaging and will introduce the CXCR4-targeted theranostic concept for advanced hematological malignancies.}, language = {en} } @article{HiguchiWerner2023, author = {Higuchi, Takahiro and Werner, Rudolf A.}, title = {Unfolding the cardioprotective potential of sigma-1 receptor-directed molecular imaging}, series = {Journal of Nuclear Cardiology}, volume = {30}, journal = {Journal of Nuclear Cardiology}, number = {2}, doi = {10.1007/s12350-022-03077-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324600}, pages = {662-664}, year = {2023}, abstract = {No abstract available.}, language = {en} } @article{LambertiniHartrampfHiguchietal.2022, author = {Lambertini, Alessandro and Hartrampf, Philipp E. and Higuchi, Takahiro and Serfling, Sebastian E. and Meybohm, Patrick and Schirbel, Andreas and Buck, Andreas K. and Werner, Rudolf A.}, title = {CXCR4-targeted molecular imaging after severe SARS-Cov-2 infection}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {50}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {1}, doi = {10.1007/s00259-022-05932-4}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324619}, pages = {228-229}, year = {2022}, abstract = {No abstract available.}, language = {en} } @article{WeichHiguchiBundschuhetal.2022, author = {Weich, Alexander and Higuchi, Takahiro and Bundschuh, Ralph A. and Lapa, Constantin and Serfling, Sebastian E. and Rowe, Steven P. and Pomper, Martin G. and Herrmann, Ken and Buck, Andreas K. and Derlin, Thorsten and Werner, Rudolf A.}, title = {Training on reporting and data system (RADS) for somatostatin-receptor targeted molecular imaging can reduce the test anxiety of inexperienced readers}, series = {Molecular Imaging and Biology}, volume = {24}, journal = {Molecular Imaging and Biology}, number = {4}, doi = {10.1007/s11307-022-01712-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324645}, pages = {631-640}, year = {2022}, abstract = {Purpose For somatostatin receptor (SSTR)-positron emission tomography/computed tomography (PET/CT), a standardized framework termed SSTR-reporting and data system (RADS) has been proposed. We aimed to elucidate the impact of a RADS-focused training on reader's anxiety to report on SSTR-PET/CT, the motivational beliefs in learning such a system, whether it increases reader's confidence, and its implementation in clinical routine. Procedures A 3-day training course focusing on SSTR-RADS was conducted. Self-report questionnaires were handed out prior to the course (Pre) and thereafter (Post). The impact of the training on the following categories was evaluated: (1) test anxiety to report on SSTR-PET/CT, (2) motivational beliefs, (3) increase in reader's confidence, and (4) clinical implementation. To assess the effect size of the course, Cohen's d was calculated (small, d = 0.20; large effect, d = 0.80). Results Of 22 participants, Pre and Post were returned by 21/22 (95.5\%). In total, 14/21 (66.7\%) were considered inexperienced (IR, < 1 year experience in reading SSTR-PET/CTs) and 7/21 (33.3\%) as experienced readers (ER, > 1 year). Applying SSTR-RADS, a large decrease in anxiety to report on SSTR-PET/CT was noted for IR (d =  - 0.74, P = 0.02), but not for ER (d = 0.11, P = 0.78). For the other three categories motivational beliefs, reader's confidence, and clinical implementation, agreement rates were already high prior to the training and persisted throughout the course (P ≥ 0.21). Conclusions A framework-focused reader training can reduce anxiety to report on SSTR-PET/CTs, in particular for inexperienced readers. This may allow for a more widespread adoption of this system, e.g., in multicenter trials for better intra- and interindividual comparison of scan results.}, language = {en} } @article{BrumbergBlazhenetsSchroeteretal.2019, author = {Brumberg, Joachim and Blazhenets, Ganna and Schr{\"o}ter, Nils and Frings, Lars and Jost, Wolfgang H. and Lapa, Constantin and Meyer, Philipp T.}, title = {Imaging cardiac sympathetic innervation with MIBG: linear conversion of the heart-to-mediastinum ratio between different collimators}, series = {EJNMMI Physics}, volume = {6}, journal = {EJNMMI Physics}, doi = {10.1186/s40658-019-0250-2}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-221675}, year = {2019}, abstract = {Background The heart-to-mediastinum (H/M) ratio is a commonly used parameter to measure cardiac I-123 metaiodobenzylguanidine (MIBG) uptake. Since the H/M ratio is substantially influenced by the collimator type, we investigated whether an empirical linear conversion of H/M ratios between camera systems with low-energy (LE) and medium-energy (ME) collimator is possible. Methods We included 18 patients with parkinsonism who were referred to one of the two participating molecular imaging facilities for the evaluation of cardiac sympathetic innervation by MIBG scintigraphy. Two consecutive planar image datasets were acquired with LE and ME collimators at 4 h after MIBG administration. Linear regression analyses were performed to describe the association between the H/M ratios gained with both collimator settings, and the accuracy of a linear transfer of the H/M ratio between collimators and across centers was assessed using a leave-one-out procedure. Results H/M ratios acquired with LE and ME collimators showed a strong linear relationship both within each imaging facility (R\(^2\) = 0.99, p < 0.001 and R\(^2\) = 0.90, p < 0.001) and across centers (H/M-LE = 0.41 × H/M-ME + 0.63, R\(^2\) = 0.97, p < 0.001). A linear conversion of H/M ratios between collimators and across centers was estimated to be very accurate (mean absolute error 0.05 ± 0.04; mean relative absolute error 3.2 ± 2.6\%). Conclusions The present study demonstrates that a simple linear conversion of H/M ratios acquired with different collimators is possible with high accuracy. This should greatly facilitate the exchange of normative data between settings and pooling of data from different institutions.}, language = {en} } @article{WevrettFenwickScuffhametal.2018, author = {Wevrett, Jill and Fenwick, Andrew and Scuffham, James and Johansson, Lena and Gear, Jonathan and Schl{\"o}gl, Susanne and Segbers, Marcel and Sj{\"o}green-Gleisner, Katarina and Soln{\´y}, Pavel and Lassmann, Michael and Tipping, Jill and Nisbet, Andrew}, title = {Inter-comparison of quantitative imaging of lutetium-177 (\(^{177}\)Lu) in European hospitals}, series = {EJNMMI Physics}, volume = {5}, journal = {EJNMMI Physics}, doi = {10.1186/s40658-018-0213-z}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-233658}, year = {2018}, abstract = {Background This inter-comparison exercise was performed to demonstrate the variability of quantitative SPECT/CT imaging for lutetium-177 (\(^{177}\)Lu) in current clinical practice. Our aim was to assess the feasibility of using international inter-comparison exercises as a means to ensure consistency between clinical sites whilst enabling the sites to use their own choice of quantitative imaging protocols, specific to their systems. Dual-compartment concentric spherical sources of accurately known activity concentrations were prepared and sent to seven European clinical sites. The site staff were not aware of the true volumes or activity within the sources—they performed SPECT/CT imaging of the source, positioned within a water-filled phantom, using their own choice of parameters and reported their estimate of the activities within the source. Results The volumes reported by the participants for the inner section of the source were all within 29\% of the true value and within 60\% of the true value for the outer section. The activities reported by the participants for the inner section of the source were all within 20\% of the true value, whilst those reported for the outer section were up to 83\% different to the true value. Conclusions A variety of calibration and segmentation methods were used by the participants for this exercise which demonstrated the variability of quantitative imaging across clinical sites. This paper presents a method to assess consistency between sites using different calibration and segmentation methods.}, language = {en} }