@article{WernerDerlinLapaetal.2020, author = {Werner, Rudolf A. and Derlin, Thorsten and Lapa, Constantin and Sheikbahaei, Sara and Higuchi, Takahiro and Giesel, Frederik L. and Behr, Spencer and Drzezga, Alexander and Kimura, Hiroyuki and Buck, Andreas K. and Bengel, Frank M. and Pomper, Martin G. and Gorin, Michael A. and Rowe, Steven P.}, title = {\(^{18}\)F-labeled, PSMA-targeted radiotracers: leveraging the advantages of radiofluorination for prostate cancer molecular imaging}, series = {Theranostics}, volume = {10}, journal = {Theranostics}, number = {1}, issn = {1838-7640}, doi = {10.7150/thno.37894}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-202559}, pages = {1-16}, year = {2020}, abstract = {Prostate-specific membrane antigen (PSMA)-targeted PET imaging for prostate cancer with \(^{68}\)Ga-labeled compounds has rapidly become adopted as part of routine clinical care in many parts of the world. However, recent years have witnessed the start of a shift from \(^{68}\)Ga- to \(^{18}\)F-labeled PSMA-targeted compounds. The latter imaging agents have several key advantages, which may lay the groundwork for an even more widespread adoption into the clinic. First, facilitated delivery from distant suppliers expands the availability of PET radiopharmaceuticals in smaller hospitals operating a PET center but lacking the patient volume to justify an onsite \(^{68}\)Ge/\(^{68}\)Ga generator. Thus, such an approach meets the increasing demand for PSMA-targeted PET imaging in areas with lower population density and may even lead to cost-savings compared to in-house production. Moreover, \(^{18}\)F-labeled radiotracers have a higher positron yield and lower positron energy, which in turn decreases image noise, improves contrast resolution, and maximizes the likelihood of detecting subtle lesions. In addition, the longer half-life of 110 min allows for improved delayed imaging protocols and flexibility in study design, which may further increase diagnostic accuracy. Moreover, such compounds can be distributed to sites which are not allowed to produce radiotracers on-site due to regulatory issues or to centers without access to a cyclotron. In light of these advantageous characteristics, \(^{18}\)F-labeled PSMA-targeted PET radiotracers may play an important role in both optimizing this transformative imaging modality and making it widely available. We have aimed to provide a concise overview of emerging \(^{18}\)F-labeled PSMA-targeted radiotracers undergoing active clinical development. Given the wide array of available radiotracers, comparative studies are needed to firmly establish the role of the available \(^{18}\)F-labeled compounds in the field of molecular PCa imaging, preferably in different clinical scenarios.}, language = {en} } @article{LapaLueckerathKleinleinetal.2016, author = {Lapa, Constantin and L{\"u}ckerath, Katharina and Kleinlein, Irene and Monoranu, Camelia Maria and Linsenmann, Thomas and Kessler, Almuth F. and Rudelius, Martina and Kropf, Saskia and Buck, Andreas K. and Ernestus, Ralf-Ingo and Wester, Hans-J{\"u}rgen and L{\"o}hr, Mario and Herrmann, Ken}, title = {\(^{68}\)Ga-Pentixafor-PET/CT for Imaging of Chemokine Receptor 4 Expression in Glioblastoma}, series = {Theranostics}, volume = {6}, journal = {Theranostics}, number = {3}, doi = {10.7150/thno.13986}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-168174}, pages = {428-434}, year = {2016}, abstract = {Chemokine receptor-4 (CXCR4) has been reported to be overexpressed in glioblastoma (GBM) and to be associated with poor survival. This study investigated the feasibility of non-invasive CXCR4-directed imaging with positron emission tomography/computed tomography (PET/CT) using the radiolabelled chemokine receptor ligand \(^{68}\)Ga-Pentixafor. 15 patients with clinical suspicion on primary or recurrent glioblastoma (13 primary, 2 recurrent tumors) underwent \(^{68}\)Ga-Pentixafor-PET/CT for assessment of CXCR4 expression prior to surgery. O-(2-\(^{18}\)F-fluoroethyl)-L-tyrosine (\(^{18}\)F-FET) PET/CT images were available in 11/15 cases and were compared visually and semi-quantitatively (SUV\(_{max}\), SUV\(_{mean}\)). Tumor-to-background ratios (TBR) were calculated for both PET probes. \(^{68}\)Ga-Pentixafor-PET/CT results were also compared to histological CXCR4 expression on neuronavigated surgical samples. \(^{68}\)Ga-Pentixafor-PET/CT was visually positive in 13/15 cases with SUV\(_{mean}\) and SUV\(_{max}\) of 3.0±1.5 and 3.9±2.0 respectively. Respective values for \(^{18}\)F-FET were 4.4±2.0 (SUV\(_{mean}\)) and 5.3±2.3 (SUV\(_{max}\)). TBR for SUV\(_{mean}\) and SUV\(_{max}\) were higher for \(^{68}\)Ga-Pentixafor than for \(^{18}\)F-FET (SUV\(_{mean}\) 154.0±90.7 vs. 4.1±1.3; SUV\(_{max}\) 70.3±44.0 and 3.8±1.2, p<0.01), respectively. Histological analysis confirmed CXCR4 expression in tumor areas with high \(^{68}\)Ga-Pentixafor uptake; regions of the same tumor without apparent \(^{68}\)Ga-Pentixafor uptake showed no or low receptor expression. In this pilot study, \(^{68}\)Ga-Pentixafor retention has been observed in the vast majority of glioblastoma lesions and served as readout for non-invasive determination of CXCR4 expression. Given the paramount importance of the CXCR4/SDF-1 axis in tumor biology, \(^{68}\)Ga-Pentixafor-PET/CT might prove a useful tool for sensitive, non-invasive in-vivo quantification of CXCR4 as well as selection of patients who might benefit from CXCR4-directed therapy.}, language = {en} } @article{BaurSchedelbeckPulzeretal.2015, author = {Baur, Johannes and Schedelbeck, Ulla and Pulzer, Alina and Bluemel, Christina and Wild, Vanessa and Fassnacht, Martin and Steger, U.}, title = {A case report of a solitary pancreatic metastasis of an adrenocortical carcinoma}, series = {BMC Surgery}, volume = {15}, journal = {BMC Surgery}, number = {93}, doi = {10.1186/s12893-015-0076-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-126130}, year = {2015}, abstract = {Background Solitary metastases to the pancreas are rare. Therefore the value of resection in curative intention remains unclear. In the literature there are several promising reports about resection of solitary metastasis to the pancreas mainly of renal origin. Case presentation Here we report for the first time on the surgical therapy of a 1.5 cm solitary pancreatic metastasis of an adrenocortical carcinoma. The metastasis occurred almost 6 years after resection of the primary tumor. A partial pancreatoduodenectomy was performed and postoperatively adjuvant mitotane treatment was initiated. During the follow-up of 3 years after surgery no evidence of tumor recurrence occurred. Conclusion Resection of pancreatic tumors should be considered, even if the mass is suspicious for metastatic disease including recurrence of adrenocortical cancer.}, language = {en} } @article{TranGiaDenisBacelarFerreiraetal.2021, author = {Tran-Gia, Johannes and Denis-Bacelar, Ana M. and Ferreira, Kelley M. and Robinson, Andrew P. and Calvert, Nicholas and Fenwick, Andrew J. and Finocchiaro, Domenico and Fioroni, Federica and Grassi, Elisa and Heetun, Warda and Jewitt, Stephanie J. and Kotzassarlidou, Maria and Ljungberg, Michael and McGowan, Daniel R. and Scott, Nathaniel and Scuffham, James and Gleisner, Katarina Sj{\"o}green and Tipping, Jill and Wevrett, Jill and Lassmann, Michael}, title = {A multicentre and multi-national evaluation of the accuracy of quantitative Lu-177 SPECT/CT imaging performed within the MRTDosimetry project}, series = {EJNMMI Physics}, volume = {8}, journal = {EJNMMI Physics}, doi = {10.1186/s40658-021-00397-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-270380}, year = {2021}, abstract = {Purpose Patient-specific dosimetry is required to ensure the safety of molecular radiotherapy and to predict response. Dosimetry involves several steps, the first of which is the determination of the activity of the radiopharmaceutical taken up by an organ/lesion over time. As uncertainties propagate along each of the subsequent steps (integration of the time-activity curve, absorbed dose calculation), establishing a reliable activity quantification is essential. The MRTDosimetry project was a European initiative to bring together expertise in metrology and nuclear medicine research, with one main goal of standardizing quantitative \(^{177}\)Lu SPECT/CT imaging based on a calibration protocol developed and tested in a multicentre inter-comparison. This study presents the setup and results of this comparison exercise. Methods The inter-comparison included nine SPECT/CT systems. Each site performed a set of three measurements with the same setup (system, acquisition and reconstruction): (1) Determination of an image calibration for conversion from counts to activity concentration (large cylinder phantom), (2) determination of recovery coefficients for partial volume correction (IEC NEMA PET body phantom with sphere inserts), (3) validation of the established quantitative imaging setup using a 3D printed two-organ phantom (ICRP110-based kidney and spleen). In contrast to previous efforts, traceability of the activity measurement was required for each participant, and all participants were asked to calculate uncertainties for their SPECT-based activities. Results Similar combinations of imaging system and reconstruction lead to similar image calibration factors. The activity ratio results of the anthropomorphic phantom validation demonstrate significant harmonization of quantitative imaging performance between the sites with all sites falling within one standard deviation of the mean values for all inserts. Activity recovery was underestimated for total kidney, spleen, and kidney cortex, while it was overestimated for the medulla. Conclusion This international comparison exercise demonstrates that harmonization of quantitative SPECT/CT is feasible when following very specific instructions of a dedicated calibration protocol, as developed within the MRTDosimetry project. While quantitative imaging performance demonstrates significant harmonization, an over- and underestimation of the activity recovery highlights the limitations of any partial volume correction in the presence of spill-in and spill-out between two adjacent volumes of interests.}, language = {en} } @article{WenzArndtSamnick2022, author = {Wenz, Jan and Arndt, Felix and Samnick, Samuel}, title = {A new concept for the production of \(^{11}\)C-labelled radiotracers}, series = {EJNMMI Radiopharmacy and Chemistry}, volume = {7}, journal = {EJNMMI Radiopharmacy and Chemistry}, doi = {10.1186/s41181-022-00159-y}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300731}, year = {2022}, abstract = {Background The GMP-compliant production of radiopharmaceuticals has been performed using disposable units (cassettes) with a dedicated synthesis module. To expand this "plug 'n' synthesize" principle to a broader scope of modules we developed a pressure controlled setup that offers an alternative to the usual stepper motor controlled rotary valves. The new concept was successfully applied to the synthesis of N-methyl-[\(^{11}\)C]choline, L-S-methyl-[\(^{11}\)C]methionine and [11C]acetate. Results The target gas purification of cyclotron produced [\(^{11}\)C]CO\(_2\) and subsequent conversion to [\(^{11}\)C]MeI was carried out on a TRACERlab Fx C Pro module. The labelling reactions were controlled with a TRACERlab Fx FE module. With the presented modular principle we were able to produce N-methyl-[\(^{11}\)C]choline and L-S-methyl-[\(^{11}\)C]methionine by loading a reaction loop with neat N,N'-dimethylaminoethanol (DMAE) or an ethanol/water mixture of NaOH and L-homocysteine (L-HC), respectively and a subsequent reaction with [\(^{11}\)C]MeI. After 18 min N-methyl-[\(^{11}\)C]choline was isolated with 52\% decay corrected yield and a radiochemical purity of > 99\%. For L-S-methyl-[\(^{11}\)C]methionine the total reaction time was 19 min reaction, yielding 25\% of pure product (> 97\%). The reactor design was used as an exemplary model for the technically challenging [\(^{11}\)C]acetate synthesis. The disposable unit was filled with 1 mL MeMgCl (0.75 M) in tetrahydrofuran (THF) bevore [\(^{11}\)C]CO\(_2\) was passed through. After complete release of [\(^{11}\)C]CO\(_2\) the reaction mixture was quenched with water and guided through a series of ion exchangers (H\(^+\), Ag\(^+\) and OH\(^-\)). The product was retained on a strong anion exchanger, washed with water and finally extracted with saline. The product mixture was acidified and degassed to separate excess [\(^{11}\)C]CO\(_2\) before dispensing. Under these conditions the total reaction time was 18 ± 2 min and pure [\(^{11}\)C]acetate (n = 10) was isolated with a decay corrected yield of 51 ± 5\%. Conclusion Herein, we described a novel single use unit for the synthesis of carbon-11 labelled tracers for preclinical and clinical applications of N-methyl-[\(^{11}\)C]choline, L-S-methyl-[\(^{11}\)C]methionine and [11C]acetate.}, language = {en} } @article{DrozdSaenkoBranovanetal.2021, author = {Drozd, Valentina and Saenko, Vladimir and Branovan, Daniel I. and Brown, Kate and Yamashita, Shunichi and Reiners, Christoph}, title = {A search for causes of rising incidence of differentiated thyroid cancer in children and adolescents after Chernobyl and Fukushima: comparison of the clinical features and their relevance for treatment and prognosis}, series = {International Journal of Environmental Research and Public Health}, volume = {18}, journal = {International Journal of Environmental Research and Public Health}, number = {7}, issn = {1660-4601}, doi = {10.3390/ijerph18073444}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-234247}, year = {2021}, abstract = {The incidence of differentiated thyroid cancer (DTC) is steadily increasing globally. Epidemiologists usually explain this global upsurge as the result of new diagnostic modalities, screening and overdiagnosis as well as results of lifestyle changes including obesity and comorbidity. However, there is evidence that there is a real increase of DTC incidence worldwide in all age groups. Here, we review studies on pediatric DTC after nuclear accidents in Belarus after Chernobyl and Japan after Fukushima as compared to cohorts without radiation exposure of those two countries. According to the Chernobyl data, radiation-induced DTC may be characterized by a lag time of 4-5 years until detection, a higher incidence in boys, in children of youngest age, extrathyroidal extension and distant metastases. Radiation doses to the thyroid were considerably lower by appr. two orders of magnitude in children and adolescents exposed to Fukushima as compared to Chernobyl. In DTC patients detected after Fukushima by population-based screening, most of those characteristics were not reported, which can be taken as proof against the hypothesis, that radiation is the (main) cause of those tumors. However, roughly 80\% of the Fukushima cases presented with tumor stages higher than microcarcinomas pT1a and 80\% with lymph node metastases pN1. Mortality rates in pediatric DTC patients are generally very low, even at higher tumor stages. However, those cases considered to be clinically relevant should be followed-up carefully after treatment because of the risk of recurrencies which is expected to be not negligible. Considering that thyroid doses from the Fukushima accident were quite small, it makes sense to assess the role of other environmental and lifestyle-related factors in thyroid carcinogenesis. Well-designed studies with assessment of radiation doses from medical procedures and exposure to confounders/modifiers from the environment as e.g., nitrate are required to quantify their combined effect on thyroid cancer risk.}, language = {en} } @unpublished{WernerAndreeJavadietal.2018, author = {Werner, Rudolf A. and Andree, Christian and Javadi, Mehrbod S. and Lapa, Constantin and Buck, Andreas K. and Higuchi, Takahiro and Pomper, Martin G. and Gorin, Michael A. and Rowe, Steven P. and Pienta, Kenneth J.}, title = {A Voice From the Past: Re-Discovering the Virchow Node with PSMA-targeted \(^{18}\)F-DCFPyL PET Imaging}, series = {Urology - The Gold Journal}, journal = {Urology - The Gold Journal}, issn = {0090-4295}, doi = {10.1016/j.urology.2018.03.030}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-161103}, year = {2018}, abstract = {No abstract available.}, subject = {Virchow Node}, language = {en} } @article{WernerAndreeJavadietal.2018, author = {Werner, Rudolf A. and Andree, Christian and Javadi, Mehrbod S. and Lapa, Constantin and Buck, Andreas K. and Higuchi, Takahiro and Pomper, Martin G. and Gorin, Michael A. and Rowe, Steven P. and Pienta, Kenneth J.}, title = {A Voice From the Past: Re-Discovering the Virchow Node with PSMA-targeted \(^{18}\)F-DCFPyL PET Imaging}, series = {Urology - The Gold Journal}, volume = {117}, journal = {Urology - The Gold Journal}, issn = {0090-4295}, doi = {10.1016/j.urology.2018.03.030}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-164632}, pages = {18-21}, year = {2018}, abstract = {No abstract available.}, language = {en} } @article{LeubeGustafssonLassmannetal.2022, author = {Leube, Julian and Gustafsson, Johan and Lassmann, Michael and Salas-Ramirez, Maikol and Tran-Gia, Johannes}, title = {Analysis of a deep learning-based method for generation of SPECT projections based on a large Monte Carlo simulated dataset}, series = {EJNMMI Physics}, volume = {9}, journal = {EJNMMI Physics}, issn = {2197-7364}, doi = {10.1186/s40658-022-00476-w}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300697}, year = {2022}, abstract = {Background In recent years, a lot of effort has been put in the enhancement of medical imaging using artificial intelligence. However, limited patient data in combination with the unavailability of a ground truth often pose a challenge to a systematic validation of such methodologies. The goal of this work was to investigate a recently proposed method for an artificial intelligence-based generation of synthetic SPECT projections, for acceleration of the image acquisition process based on a large dataset of realistic SPECT simulations. Methods A database of 10,000 SPECT projection datasets of heterogeneous activity distributions of randomly placed random shapes was simulated for a clinical SPECT/CT system using the SIMIND Monte Carlo program. Synthetic projections at fixed angular increments from a set of input projections at evenly distributed angles were generated by different u-shaped convolutional neural networks (u-nets). These u-nets differed in noise realization used for the training data, number of input projections, projection angle increment, and number of training/validation datasets. Synthetic projections were generated for 500 test projection datasets for each u-net, and a quantitative analysis was performed using statistical hypothesis tests based on structural similarity index measure and normalized root-mean-squared error. Additional simulations with varying detector orbits were performed on a subset of the dataset to study the effect of the detector orbit on the performance of the methodology. For verification of the results, the u-nets were applied to Jaszczak and NEMA physical phantom data obtained on a clinical SPECT/CT system. Results No statistically significant differences were observed between u-nets trained with different noise realizations. In contrast, a statistically significant deterioration was found for training with a small subset (400 datasets) of the 10,000 simulated projection datasets in comparison with using a large subset (9500 datasets) for training. A good agreement between synthetic (i.e., u-net generated) and simulated projections before adding noise demonstrates a denoising effect. Finally, the physical phantom measurements show that our findings also apply for projections measured on a clinical SPECT/CT system. Conclusion Our study shows the large potential of u-nets for accelerating SPECT/CT imaging. In addition, our analysis numerically reveals a denoising effect when generating synthetic projections with a u-net. Clinically interesting, the methodology has proven robust against camera orbit deviations in a clinically realistic range. Lastly, we found that a small number of training samples (e.g., ~ 400 datasets) may not be sufficient for reliable generalization of the u-net.}, language = {en} } @article{SchadtIsraelBeezetal.2023, author = {Schadt, Fabian and Israel, Ina and Beez, Alexandra and Alushi, Kastriot and Weiland, Judith and Ernestus, Ralf-Ingo and Westermaier, Thomas and Samnick, Samuel and Lilla, Nadine}, title = {Analysis of cerebral glucose metabolism following experimental subarachnoid hemorrhage over 7 days}, series = {Scientific Reports}, volume = {13}, journal = {Scientific Reports}, number = {1}, doi = {10.1038/s41598-022-26183-1}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300725}, year = {2023}, abstract = {Little is known about changes in brain metabolism following SAH, possibly leading towards secondary brain damage. Despite sustained progress in the last decade, analysis of in vivo acquired data still remains challenging. The present interdisciplinary study uses a semi-automated data analysis tool analyzing imaging data independently from the administrated radiotracer. The uptake of 2-[18F]Fluoro-2-deoxy-glucose ([\(^{18}\)F]FDG) was evaluated in different brain regions in 14 male Sprague-Dawley rats, randomized into two groups: (1) SAH induced by the endovascular filament model and (2) sham operated controls. Serial [\(^{18}\)F]FDG-PET measurements were carried out. Quantitative image analysis was performed by uptake ratio using a self-developed MRI-template based data analysis tool. SAH animals showed significantly higher [\(^{18}\)F]FDG accumulation in gray matter, neocortex and olfactory system as compared to animals of the sham group, while white matter and basal forebrain region showed significant reduced tracer accumulation in SAH animals. All significant metabolic changes were visualized from 3 h, over 24 h (day 1), day 4 and day 7 following SAH/sham operation. This [\(^{18}\)F]FDG-PET study provides important insights into glucose metabolism alterations following SAH—for the first time in different brain regions and up to day 7 during course of disease.}, language = {en} }