@article{SchickBaarBrunoetal.2015, author = {Schick, Martin Alexander and Baar, Wolfgang and Bruno, Raphael Romano and Wollborn, Jakob and Held, Christopher and Schneider, Reinhard and Flemming, Sven and Schlegel, Nicolas and Roewer, Norbert and Neuhaus, Winfried and Wunder, Christian}, title = {Balanced hydroxyethylstarch (HES 130/0.4) impairs kidney function in-vivo without inflammation}, series = {PLoS One}, volume = {10}, journal = {PLoS One}, number = {9}, doi = {10.1371/journal.pone.0137247}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-126068}, pages = {e0137247}, year = {2015}, abstract = {Volume therapy is a standard procedure in daily perioperative care, and there is an ongoing discussion about the benefits of colloid resuscitation with hydroxyethylstarch (HES). In sepsis HES should be avoided due to a higher risk for acute kidney injury (AKI). Results of the usage of HES in patients without sepsis are controversial. Therefore we conducted an animal study to evaluate the impact of 6\% HES 130/0.4 on kidney integrity with sepsis or under healthy conditions Sepsis was induced by standardized Colon Ascendens Stent Peritonitis (sCASP). sCASP-group as well as control group (C) remained untreated for 24 h. After 18 h sCASP+HES group (sCASP+VOL) and control+HES (C+VOL) received 50 ml/KG balanced 6\% HES (VOL) 130/0.4 over 6h. After 24h kidney function was measured via Inulin- and PAH-Clearance in re-anesthetized rats, and serum urea, creatinine (crea), cystatin C and Neutrophil gelatinase-associated lipocalin (NGAL) as well as histopathology were analysed. In vitro human proximal tubule cells (PTC) were cultured +/- lipopolysaccharid (LPS) and with 0.1-4.0\% VOL. Cell viability was measured with XTT-, cell toxicity with LDH-test. sCASP induced severe septic AKI demonstrated divergent results regarding renal function by clearance or creatinine measure focusing on VOL. Soleley HES (C+VOL) deteriorated renal function without sCASP. Histopathology revealed significantly derangements in all HES groups compared to control. In vitro LPS did not worsen the HES induced reduction of cell viability in PTC cells. For the first time, we demonstrated, that application of 50 ml/KG 6\% HES 130/0.4 over 6 hours induced AKI without inflammation in vivo. Severity of sCASP induced septic AKI might be no longer susceptible to the way of volume expansion}, language = {en} } @article{WurmbVollmerSefrinetal.2015, author = {Wurmb, Thomas and Vollmer, Tina and Sefrin, Peter and Kraus, Martin and Happel, Oliver and Wunder, Christian and Steinisch, Andrias and Roewer, Norbert and Maier, Sebastian}, title = {Monitoring of in-hospital cardiac arrest events with the focus on Automated External Defibrillators - a retrospective observational study}, series = {Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine}, volume = {23}, journal = {Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine}, number = {87}, doi = {10.1186/s13049-015-0170-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-125756}, year = {2015}, abstract = {Background Patients with cardiac arrest have lower survival rates, when resuscitation performance is low. In In-hospital settings the first responders on scene are usually nursing staff without rhythm analysing skills. In such cases Automated External Defibrillators (AED) might help guiding resuscitation performance. At the Wuerzburg University Hospital (Germany) an AED-program was initiated in 2007. Aim of the presented study was to monitor the impact of Automated External Defibrillators on the management of in-hospital cardiac arrest events. Methods The data acquisition was part of a continuous quality improvement process of the Wuerzburg University Hospital. For analysing the CPR performance, the chest compression rate (CCR), compression depth (CCD), the no flow fraction (NFF), time interval from AED-activation to the first compression (TtC), the time interval from AED-activation to the first shock (TtS) and the post schock pause (TtCS) were determined by AED captured data. A questionnaire was completed by the first responders. Results From 2010 to 2012 there were 359 emergency calls. From these 53 were cardiac arrests with an AED-application. Complete data were available in 46 cases. The TtC was 34 (32-52) seconds (median and IQR).The TtS was 30 (28-32) seconds (median and IQR) . The TtCS was 4 (3-6) seconds (median and IQR) . The CCD was 5.5 ± 1 cm while the CCR was 107 ± 11/min. The NFF was calculated as 41 \%. ROSC was achieved in 21 patients (45 \%), 8 patients (17 \%) died on scene and 17 patients (37 \%) were transferred under ongoing CPR to an Intensive Care Unit (ICU). Conclusion The TtS and TtC indicate that there is an AED-user dependent time loss. These time intervals can be markedly reduced, when the user is trained to interrupt the AED's "chain of advices" by placing the electrode-paddles immediately on the patient's thorax. At this time the AED switches directly to the analysing mode. Intensive training and adaption of the training contents is needed to optimize the handling of the AED in order to maximize its advantages and to minimize its disadvantages.}, language = {en} } @article{ShityakovPuskasPapaietal.2015, author = {Shityakov, Sergey and Pusk{\´a}s, Istv{\´a}n and P{\´a}pai, Katalin and Salvador, Ellaine and Roewer, Norbert and F{\"o}rster, Carola and Broscheit, Jens-Albert}, title = {Sevoflurane-sulfobutylether-\(\beta\)-cyclodextrin complex: preparation, characterization, cellular toxicity, molecular modeling and blood-brain barrier transport studies}, series = {Molecules}, volume = {20}, journal = {Molecules}, doi = {10.3390/molecules200610264}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-148543}, pages = {10264-10279}, year = {2015}, abstract = {The objective of the present investigation was to study the ability of sulfobutylether-\(\beta\)-cyclodextrin (SBECD) to form an inclusion complex with sevoflurane (SEV), a volatile anesthetic with poor water solubility. The inclusion complex was prepared, characterized and its cellular toxicity and blood-brain barrier (BBB) permeation potential of the formulated SEV have also been examined for the purpose of controlled drug delivery. The SEV-SBE\(\beta\)CD complex was nontoxic to the primary brain microvascular endothelial (pEND) cells at a clinically relevant concentration of sevoflurane. The inclusion complex exhibited significantly higher BBB permeation profiles as compared with the reference substance (propranolol) concerning calculated apparent permeability values (P\(_{app}\)). In addition, SEV binding affinity to SBE\(\beta\)CD was confirmed by a minimal Gibbs free energy of binding (ΔG\(_{bind}\)) value of -1.727 ± 0.042 kcal・mol\(^{-1}\) and an average binding constant (K\(_{b}\)) of 53.66 ± 9.24 mM indicating rapid drug liberation from the cyclodextrin amphiphilic cavity.}, language = {en} } @article{WollbornWunderStixetal.2015, author = {Wollborn, Jakob and Wunder, Christian and Stix, Jana and Neuhaus, Winfried and Bruno, Rapahel R. and Baar, Wolfgang and Flemming, Sven and Roewer, Norbert and Schlegel, Nicolas and Schick, Martin A.}, title = {Phosphodiesterase-4 inhibition with rolipram attenuates hepatocellular injury in hyperinflammation in vivo and in vitro without influencing inflammation and HO-1 expression}, series = {Journal of Pharmacology and Pharmacotherapeutics}, volume = {6}, journal = {Journal of Pharmacology and Pharmacotherapeutics}, number = {1}, doi = {10.4103/0976-500X.149138}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-149336}, pages = {13-23}, year = {2015}, abstract = {Objective: To investigate the impact of the phophodiesterase-4 inhibition (PD-4-I) with rolipram on hepatic integrity in lipopolysaccharide (LPS) induced hyperinflammation. Materials and Methods: Liver microcirculation in rats was obtained using intravital microscopy. Macrohemodynamic parameters, blood assays, and organs were harvested to determine organ function and injury. Hyperinflammation was induced by LPS and PD-4-I rolipram was administered intravenously one hour after LPS application. Cell viability of HepG2 cells was measured by EZ4U-kit based on the dye XTT. Experiments were carried out assessing the influence of different concentrations of tumor necrosis factor alpha (TNF-α) and LPS with or without PD-4-I. Results: Untreated LPS-induced rats showed significantly decreased liver microcirculation and increased hepatic cell death, whereas LPS + PD-4-I treatment could improve hepatic volumetric flow and cell death to control level whithout influencing the inflammatory impact. In HepG2 cells TNF-α and LPS significantly reduced cell viability. Coincubation with PD-4-I increased HepG2 viability to control levels. The heme oxygenase 1 (HO-1) pathway did not induce the protective effect of PD-4-I. Conclusion: Intravenous PD-4-I treatment was effective in improving hepatic microcirculation and hepatic integrity, while it had a direct protective effect on HepG2 viability during inflammation.}, language = {en} }