@phdthesis{He2024, author = {He, Feng}, title = {Drug Discovery based on Oxidative Stress and HDAC6 for Treatment of Neurodegenerative Diseases}, doi = {10.25972/OPUS-25349}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-253497}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2024}, abstract = {Most antioxidants reported so far only achieved limited success in AD clinical trials. Growing evidences suggest that merely targeting oxidative stress will not be sufficient to fight AD. While multi-target directed ligands could synergistically modulate different steps in the neurodegenerative process, offering a promising potential for treatment of this complex disease. Fifteen target compounds have been designed by merging melatonin and ferulic acid into the cap group of a tertiary amide HDAC6 inhibitor. Compound 10b was screened as the best hybrid molecule exhibit potent HDAC6 inhibition and potent antioxidant capacity. Compound 10b also alleviated LPS-induced microglia inflammation and led to a switch from neurotoxic M1 to the neuroprotective M2 microglial phenotype. Moreover, compound 10b show pronounced attenuation of spatial working memory and long-term memory damage in an in vivo AD mouse model. Compound 10b can be a potentially effective drug candidate for treatment of AD and its druggability worth to be further studied. We have designed ten novel neuroprotectants by hybridizing with several common antioxidants, including ferulic acid, melatonin, lipoic acid, and trolox. The trolox hybrid compound exhibited the most potent neuroprotective effects in multiple neuroprotection assays. Besides, we identified the synergistic effects between trolox and vitamin K derivative, and our trolox hybrid compound showed comparable neuroprotection with the mixture of trolox and vitamin K derivative. We have designed and synthesized 24 quinone derivatives based on five kinds of different quinones including ubiquinone, 2,3,5-trimethyl-1,4-benzoquinone, memoquin, thymoquinone, and anthraquinone. Trimethylbenzoquinone and thymoquinone derivatives showed more potent neuroprotection than other quinones in oxytosis assay. Therefore, trimethylbenzoquinone and thymoquinone derivatives can be used as lead compounds for further mechanism study and drug discovery for treatment of neurodegenerative disease. We designed a series of photoswitchable HDAC inhibitors, which could be effective molecular tools due to the high spatial and temporal resolution. In total 23 target compounds were synthesized and photophysicochemically characterized. Azoquinoline-based compounds possess more thermally stable cis-isomers in buffer solution, which were further tested in enzyme-based HDAC inhibition assay. However, none of those tested compounds show significant differences in activities between trans-isomers and corresponding cis-isomers.}, subject = {Alzheimerkrankheit}, language = {en} } @phdthesis{Boehm2023, author = {B{\"o}hm, Christoph}, title = {Thermal Stability of the Polyesters PCL and PLGA during Melt Electrowriting}, doi = {10.25972/OPUS-30613}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-306139}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2023}, abstract = {The focus of this thesis was to investigate how PCL and PLGA react to the heat exposure that comes with the MEW process over a defined timespan. To assess the thermal stability of PCL during MEW over 25 d, an automated collection of fibers has been used to determine the CTS on each day of heating for three different temperatures. PCL is exceptionally stable over 25 d at 75 °C, whereas for 85 °C and 95 °C a slight upward trend during the last 10 d could be observed, which is an indication for thermal degradation. Same trend could be observed for diameter of fibers produced at a fixed collector speed. For all temperatures, CTS during the first 5 d decreased due to inhomogeneities of the melt. Physical analysis of the fibers by XRD and mechanical testing showed no significant changes. To investigate the chemical details of the thermal durability, PCL was artificially aged over 25 d at 75 °C, 85 °C and 95 °C. Data from GPC analysis and rheology revealed that PCL is degrading steadily at all three temperatures. Combined with GC-MS analysis, two different mechanisms for degradation could be observed: random chain scission and unzipping. Additional GPC experiment using a mixture of PCL and a fluorescence labelled PCL showed that PCL was undergoing ester interchange reactions, which could explain its thermal stability. PLGA was established successfully as material for MEW. GPC results revealed that PLGA degraded heavily in the one-hour preheating period. To reduce the processing temperature, ATEC was blended with PLGA in three mixtures. This slowed down degradation and a processing window of 6 h could be established. Mechanical testing with fibers produced with PLGA and all three blends was performed. PLGA was very brittle, whereas the blends showed an elastic behavior. This could be explained by ester interchange reactions that formed a loosely crosslinked network with ATEC.}, subject = {Degradation}, language = {en} } @phdthesis{Gold2023, author = {Gold, Lukas}, title = {Methods for the state estimation of lithium-ion batteries}, doi = {10.25972/OPUS-30618}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-306180}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2023}, abstract = {This work introduced the reader to all relevant fields to tap into an ultrasound-based state of charge estimation and provides a blueprint for the procedure to achieve and test the fundamentals of such an approach. It spanned from an in-depth electrochemical characterization of the studied battery cells over establishing the measurement technique, digital processing of ultrasonic transmission signals, and characterization of the SoC dependent property changes of those signals to a proof of concept of an ultrasound-based state of charge estimation. The State of the art \& theoretical background chapter focused on the battery section on the mechanical property changes of lithium-ion batteries during operation. The components and the processes involved to manufacture a battery cell were described to establish the fundamentals for later interrogation. A comprehensive summary of methods for state estimation was given and an emphasis was laid on mechanical methods, including a critical review of the most recent research on ultrasound-based state estimation. Afterward, the fundamentals of ultrasonic non-destructive evaluation were introduced, starting with the sound propagation modes in isotropic boundary-free media, followed by the introduction of boundaries and non-isotropic structure to finally approach the class of fluid-saturated porous media, which batteries can be counted to. As the processing of the ultrasonic signals transmitted through lithium-ion battery cells with the aim of feature extraction was one of the main goals of this work, the fundamentals of digital signal processing and methods for the time of flight estimation were reviewed and compared in a separate section. All available information on the interrogated battery cell and the instrumentation was collected in the Experimental methods \& instrumentation chapter, including a detailed step-by-step manual of the process developed in this work to create and attach a sensor stack for ultrasonic interrogation based on low-cost off-the-shelf piezo elements. The Results \& discussion chapter opened with an in-depth electrochemical and post-mortem interrogation to reverse engineer the battery cell design and its internal structure. The combination of inductively coupled plasma-optical emission spectrometry and incremental capacity analysis applied to three-electrode lab cells, constructed from the studied battery cell's materials, allowed to identify the SoC ranges in which phase transitions and staging occur and thereby directly links changes in the ultrasonic signal properties with the state of the active materials, which makes this work stand out among other studies on ultrasound-based state estimation. Additional dilatometer experiments were able to prove that the measured effect in ultrasonic time of flight cannot originate from the thickness increase of the battery cells alone, as this thickness increase is smaller and in opposite direction to the change in time of flight. Therefore, changes in elastic modulus and density have to be responsible for the observed effect. The construction of the sensor stack from off-the-shelf piezo elements, its electromagnetic shielding, and attachment to both sides of the battery cells was treated in a subsequent section. Experiments verified the necessity of shielding and its negligible influence on the ultrasonic signals. A hypothesis describing the metal layer in the pouch foil to be the transport medium of an electrical coupling/distortion between sending and receiving sensor was formulated and tested. Impedance spectroscopy was shown to be a useful tool to characterize the resonant behavior of piezo elements and ensure the mechanical coupling of such to the surface of the battery cells. The excitation of the piezo elements by a raised cosine (RCn) waveform with varied center frequency in the range of 50 kHz to 250 kHz was studied in the frequency domain and the influence of the resonant behavior, as identified prior by impedance spectroscopy, on waveform and frequency content was evaluated to be uncritical. Therefore, the forced oscillation produced by this excitation was assumed to be mechanically coupled as ultrasonic waves into the battery cells. The ultrasonic waves transmitted through the battery cell were recorded by piezo elements on the opposing side. A first inspection of the raw, unprocessed signals identified the transmission of two main wave packages and allowed the identification of two major trends: the time of flight of ultrasonic wave packages decreases with the center frequency of the RCn waveform, and with state of charge. These trends were to be assessed further in the subsequent sections. Therefore, methods for the extraction of features (properties) from the ultrasonic signals were established, compared, and tested in a dedicated section. Several simple and advanced thresholding methods were compared with envelope-based and cross-correlation methods to estimate the time of flight (ToF). It was demonstrated that the envelope-based method yields the most robust estimate for the first and second wave package. This finding is in accordance with the literature stating that an envelope-based method is best suited for dispersive, absorptive media [204], to which lithium-ion batteries are counted. Respective trends were already suggested by the heatmap plots of the raw signals vs. RCn frequency and SoC. To enable such a robust estimate, an FIR filter had to be designed to preprocess the transmitted signals and thereby attenuate frequency components that verifiably lead to a distorted shape of the envelope. With a robust ToF estimation method selected, the characterization of the signal properties ToF and transmitted energy content (EC) was performed in-depth. A study of cycle-to-cycle variations unveiled that the signal properties are affected by a long rest period and the associated relaxation of the multi-particle system "battery cell" to equilibrium. In detail, during cycling, the signal properties don't reach the same value at a given SoC in two subsequent cycles if the first of the two cycles follows a long rest period. In accordance with the literature, a break-in period, making up for more than ten cycles post-formation, was observed. During this break-in period, the mechanical properties of the system are said to change until a steady state is reached [25]. Experiments at different C-rate showed that ultrasonic signal properties can sense the non-equilibrium state of a battery cell, characterized by an increasing area between charge and discharge curve of the respective signal property vs. SoC plot. This non-equilibrium state relaxes in the rest period following the discharge after the cut-off voltage is reached. The relaxation in the rest period following the charge is much smaller and shows little C-rate dependency as the state is prepared by constant voltage charging at the end of charge voltage. For a purely statistical SoC estimation approach, as employed in this work, where only instantaneous measurements are taken into account and the historic course of the measurement is not utilized as a source of information, the presence of hysteresis and relaxation leads to a reduced estimation accuracy. Future research should address this issue or even utilize the relaxation to improve the estimation accuracy, by incorporating historic information, e.g., by using the derivative of a signal property as an additional feature. The signal properties were then tested for their correlation with SoC as a function of RCn frequency. This allowed identifying trends in the behavior of the signal properties as a function of RCn frequency and C-rate in a condensed fashion and thereby enabled to predict the frequency range, about 50 kHz to 125 kHz, in which the course of the signal properties is best suited for SoC estimation. The final section provided a proof of concept of the ultrasound-based SoC estimation, by applying a support vector regression (SVR) to before thoroughly studied ultrasonic signal properties, as well as current and battery cell voltage. The included case study was split into different parts that assessed the ability of an SVR to estimate the SoC in a variety of scenarios. Seven battery cells, prepared with sensor stacks attached to both faces, were used to generate 14 datasets. First, a comparison of self-tests, where a portion of a dataset is used for training and another for testing, and cross-tests, which use the dataset of one cell for training and the dataset of another for testing, was performed. A root mean square error (RMSE) of 3.9\% to 4.8\% SoC and 3.6\% to 10.0\% SoC was achieved, respectively. In general, it was observed that the SVR is prone to overestimation at low SoCs and underestimation at high SoCs, which was attributed to the pronounced hysteresis and relaxation of the ultrasonic signal properties in this SoC ranges. The fact that higher accuracy is achieved, if the exact cell is known to the model, indicates that a variation between cells exists. This variation between cells can originate from differences in mechanical properties as a result of production variations or from differences in manual sensor placement, mechanical coupling, or resonant behavior of the ultrasonic sensors. To mitigate the effect of the cell-to-cell variations, a test was performed, where the datasets of six out of the seven cells were combined as training data, and the dataset of the seventh cell was used for testing. This reduced the spread of the RMSE from (3.6 - 10.0)\% SoC to (5.9 - 8.5)\% SoC, respectively, once again stating that a databased approach for state estimation becomes more reliable with a large data basis. Utilizing self-tests on seven datasets, the effect of additional features on the state estimation result was tested. The involvement of an additional feature did not necessarily improve the estimation accuracy, but it was shown that a combination of ultrasonic and electrical features is superior to the training with these features alone. To test the ability of the model to estimate the SoC in unknown cycling conditions, a test was performed where the C-rate of the test dataset was not included in the training data. The result suggests that for practical applications it might be sufficient to perform training with the boundary of the use cases in a controlled laboratory environment to handle the estimation in a broad spectrum of use cases. In comparison with literature, this study stands out by utilizing and modifying off-the-shelf piezo elements to equip state-of-the-art lithium-ion battery cells with ultrasonic sensors, employing a range of center frequencies for the waveform, transmitted through the battery cell, instead of a fixed frequency and by allowing the SVR to choose the frequency that yields the best result. The characterization of the ultrasonic signal properties as a function of RCn frequency and SoC and the assignment of characteristic changes in the signal properties to electrochemical processes, such as phase transitions and staging, makes this work unique. By studying a range of use cases, it was demonstrated that an improved SoC estimation accuracy can be achieved with the aid of ultrasonic measurements - thanks to the correlation of the mechanical properties of the battery cells with the SoC.}, subject = {Lithium-Ionen-Akkumulator}, language = {en} } @phdthesis{Bozkaya2023, author = {Bozkaya, Beg{\"u}m}, title = {Influence of Carbon Additives on the Electrochemical Performance of Modern Lead-Acid Batteries}, doi = {10.25972/OPUS-31917}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-319174}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2023}, abstract = {In the first part of this thesis, a validation of both short-term and long-term DCA tests on 2 V laboratory cells is focussed. The aim is to improve the laboratory cell level measurement technology for dynamic charge acceptance regarding the investigation of carbon additives. To address this issue, it is crucial to apply carbon additives generating a remarkable difference in charge acceptance. For this purpose, five different carbon additives providing a variation in the specific external surface were included as additives in the negative plates of 2 V lead-acid cells. Both short-term (charge acceptance test 2 from SBA and DCA from EN) and long-term (Run-in DCA from Ford) DCA tests were executed on the lead-acid cells. Further understanding of the mechanism was studied by applying electrochemical methods like cyclic voltammetry and electrochemical impedance spectroscopy. The second part of this thesis aims to understand the impact of carbon surface functional groups on the electrochemical activity of the negative electrodes as well as the DCA of 2 V lead-acid cells. In order to address this topic, commercially available activated carbon was modified by different chemical treatments to incorporate specific surface functional groups in the carbon structure. A series of activated carbons having a broad range of pH was prepared, which were used as additives in the negative electrodes. The corresponding lead-acid cells were subjected to cyclic voltammetry and DCA test according to EN. Further, the physical and chemical properties of the functionalized carbon additives were intensively analyzed to establish a structure-property relationship with a focus on DCA.}, subject = {Bleiakkumulator}, language = {en} } @phdthesis{Jarzina2022, author = {Jarzina, Sebastian Oskar}, title = {Assessment of systemic toxicity in vitro using the Adverse Outcome Pathway (AOP) concept: nephrotoxicity due to receptor-mediated endocytosis and lysosomal overload and inhibition of mtDNA polymerase-ɣ as case studies}, doi = {10.25972/OPUS-26484}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-264842}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2022}, abstract = {The US National Research Council (NRC) report "Toxicity Testing in the 21st Century: A Vision and a strategy (Tox21)", published in 2007, calls for a complete paradigm shift in tox-icity testing. A central aspect of the proposed strategy includes the transition from apical end-points in in vivo studies to more mechanistically based in vitro tests. To support and facilitate the transition and paradigm shift in toxicity testing, the Adverse Outcome Pathway (AOP) concept is widely recognized as a pragmatic tool. As case studies, the AOP concept was ap-plied in this work to develop AOPs for proximal tubule injuries initiated by Receptor-mediated endocytosis and lysosomal overload and Inhibition of mtDNA polymerase-. These AOPs were used as a mechanistic basis for the development of in vitro assays for each key event (KE). To experimentally support the developed in vitro assays, proximal tubule cells from rat (NRK-52E) and human (RPTEC/TERT1) were treated with model compounds. To measure the dis-turbance of lysosomal function in the AOP - Receptor-mediated endocytosis and lysosomal overload, polymyxin antibiotics (polymyxin B, colistin, polymyxin B nonapeptide) were used as model compounds. Altered expression of lysosomal associated membrane protein 1/2 (LAMP-1/2) (KE1) and cathepsin D release from lysosomes (KE2) were determined by im-munofluorescence, while cytotoxicity (KE3) was measured using the CellTiter-Glo® cell via-bility assay. Importantly, significant differences in polymyxin uptake and susceptibility be-tween cell lines were observed, underlining the importance of in vitro biokinetics to determine an appropriate in vitro point of departure (PoD) for risk assessment. Compared to the in vivo situation, distinct expression of relevant transporters such as megalin and cubilin on mRNA and protein level in the used cell lines (RPTEC/TERT1 and NRK-52E) could not be con-firmed, making integration of quantitative in vitro to in vivo extrapolations (QIVIVE) neces-sary. Integration of QIVIVE by project partners of the University of Utrecht showed an im-provement in the modelled biokinetic data for polymyxin B. To assess the first key event, (KE1) Depletion of mitochondrial DNA, in the AOP - Inhibition of mtDNA polymerase-, a RT-qPCR method was used to determine the mtDNA copy number in cells treated with mod-el compounds (adefovir, cidofovir, tenofovir, adefovir dipivoxil, tenofovir disoproxil fumarate). Mitochondrial toxicity (KE2) was measured by project partners using the high-content imaging technique and MitoTracker® whereas cytotoxicity (KE3) was determined by CellTiter-Glo® cell viability assay. In contrast to the mechanistic hypothesis underlying the AOP - Inhibition of mtDNA polymerase-, treatment with model compounds for 24 h resulted in an increase rather than a decrease in mtDNA copy number (KE1). Only minor effects on mitochondrial toxicity (KE2) and cytotoxicity (KE3) were observed. Treatment of RPT-EC/TERT1 cells for 14 days showed only a slight decrease in mtDNA copy number after treatment with adefovir dipivoxil and tenofovir disoproxil fumarate, underscoring some of the limitations of short-term in vitro systems. To obtain a first estimation for risk assessment based on in vitro data, potential points of departure (PoD) for each KE were calculated from the obtained in vitro data. The most common PoDs were calculated such as the effect concentra-tion at which 10 \% or 20_\% effect was measured (EC10, EC20), the highest no observed effect concentration (NOEC), the lowest observed effect concentration (LOEC), the benchmark 10 \% (lower / upper) concentrations (BMC10, BMCL10, BMCU10) and a modelled non-toxic con-centration (NtC). These PoDs were then compared with serum and tissue concentrations de-termined from in vivo studies after treatment with therapeutic / supratherapeutic doses of the respective drugs in order to obtain a first estimate of risk based on in vitro data. In addition, AOPs were used to test whether the quantitative key event relationships between key events allow prediction of downstream effects and effects on the adverse outcome (AO) based on measurements of an early key event. Predictions of cytotoxicity from the mathematical rela-tionships showed good concordance with measured cytotoxicity after treatment with colistin and polymyxin b nonapeptide. The work also revealed uncertainties and limitations of the ap-plied strategy, which have a significant impact on the prediction and on a risk assessment based on in vitro results.}, language = {en} } @phdthesis{Meininger2022, author = {Meininger, Markus}, title = {Calcium hydroxide as antibacterial implant coating}, doi = {10.25972/OPUS-26112}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-261122}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2022}, abstract = {In modern medicine hip and knee joint replacement are common surgical procedures. However, about 11 \% of hip implants and about 7 \% of knee implants need re-operations. The comparison of implant registers revealed two major indications for re-operations: aseptic loosening and implant infections, that both severely impact the patients' health and are an economic burden for the health care system. To address these problems, a calcium hydroxide coating on titanium was investigated in this thesis. Calcium hydroxide is a well-known antibacterial agent and used with success in dentistry. The coatings were applied with electrochemically assisted deposition, a versatile tool that combines easiness of process with the ability to coat complex geometries homogeneously. The pH-gradient during coating was investigated and showed the surface confinement of the coating process. Surface pre-treatment altered the surface morphology and chemistry of the titanium substrates and was shown to affect the morphology of the calcium hydroxide coatings. The influence of the coating parameters stirring speed and current pulsing were examined in various configurations and combinations and could also affect the surface morphology. A change in surface morphology results in a changed adhesion and behavior of cells and bacteria. Thus, the parameters surface pre-treatment, stirring speed and current pulsing presented a toolset for tailoring cellular response and antibacterial properties. Microbiological tests with S. aureus and S. epidermidis were performed to test the time-dependent antibacterial activity of the calcium hydroxide coatings. A reduction of both strains could be achieved for 13 h, which makes calcium hydroxide a promising antibacterial coating. To give insight into biofilm growth, a protocol for biofilm staining was investigated on titanium disks with S. aureus and S. epidermidis. Biofilm growth could be detected after 5 days of bacterial incubation, which was much earlier than the 3 weeks that are currently assumed in medical treatment. Thus, it should be considered to treat infections as if a biofilm were present from day 5 on. The ephemeral antibacterial properties of calcium hydroxide were further enhanced and prolonged with the addition of silver and copper ions. Both ionic modifications significantly enhanced the bactericidal potential. The copper modification showed higher antibacterial effects than the silver modification and had a higher cytocompatibility which was comparable to the pure calcium hydroxide coating. Thus, copper ions are an auspicious option to enhance the antibacterial properties. Calcium hydroxide coatings presented in this thesis have promising antibacterial properties and can easily be applied to complex geometries, thus they are a step in fighting aseptic loosening and implant infections.}, subject = {Calciumhydroxid}, language = {en} } @phdthesis{Hahn2022, author = {Hahn, Lukas}, title = {Novel Thermoresponsive Hydrogels Based on Poly(2-oxazoline)s and Poly(2-oxazine)s and their Application in Biofabrication}, doi = {10.25972/OPUS-27129}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-271299}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2022}, abstract = {In this work, the influence of aromatic structures on drug encapsulation, self-assembly and hydrogel formation was investigated. The physically crosslinked gelling systems were characterized and optimized for the use in biofabrication and applied in initial (bio)printing experiments. Chapter I: The cytocompatible (first in vitro and in vivo studies) amphiphile PMeOx-b-PBzOx-b- PMeOx (A-PBzOx-A) was used for the solubilization of PTX, schizandrin A (SchA), curcumin (CUR), niraparib and HS-173. Chapter II: Compared to the polymers A-PPheOx-A, A-PBzOx-A and A-PBzOzi-A, only the polymer A-PPheOzi-A showed a reversible temperature- and concentration-dependent inverse thermogelation, which is accompanied by a morphology change from long wormlike micelles in the gel to small spherical micelles in solution. The worm formation results from novel interactions between the hydrophilic and hydrophobic aromatic polymer blocks. Changes in the hydrophilic block significantly alter the gel system. Rheological properties can be optimized by concentration and temperature, which is why the hydrogel was used to significantly improve the printability and stability of Alg in a blend system. Chapter III: By extending the side chain of the aromatic hydrophobic block, the inverse thermogelling polymer A-poly(2-phenethyl-2-oxazoline)-A (A-PPhenEtOx-A) is obtained. Rapid gelation upon cooling is achieved by inter-correlating spherical micelles. Based on ideal rheological properties, first cytocompatible bioprinting experiments were performed in combination with Alg. The polymers A- poly(2-benzhydryl-2-oxazoline)-A (A-PBhOx-A) and A-poly(2-benzhydryl-2-oxazine) (A-PBhOzi-A) are characterized by two aromatic benzyl units per hydrophobic repeating unit. Only the polymer A- PBhOzi-A exhibited inverse thermogelling behavior. Merging micelles could be observed by electron microscopy. The system was rheologically characterized and discussed with respect to an application in 3D printing. Chapter IV: The thermogelling POx/POzi system, in particular the block copolymer PMeOx-b- PnPrOzi, was used in different applications in the field of biofabrication. The introduction of maleimide and furan units along the hydrophilic polymer part ensured additional stabilization by Diels-Alder crosslinking after the printing process.}, subject = {Polymer Science}, language = {en} } @phdthesis{Shan2022, author = {Shan, Junwen}, title = {Tailoring Hyaluronic Acid and Gelatin for Bioprinting}, doi = {10.25972/OPUS-29825}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-298256}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2022}, abstract = {In the field of biofabrication, biopolymer-based hydrogels are often used as bulk materials with defined structures or as bioinks. Despite their excellent biocompatibility, biopolymers need chemical modification to fulfill mechanical stability. In this thesis, the primary alcohol of hyaluronic acid was oxidized using TEMPO/TCC oxidation to generate aldehyde groups without ring-opening mechanism of glycol cleavage using sodium periodate. For crosslinking reaction of the aldehyde groups, adipic acid dihydrazide was used as bivalent crosslinker for Schiff Base chemistry. This hydrogel system with fast and reversible crosslinking mechanism was used successfully as bulk hydrogel for chondrogenic differentiation with human mesenchymal stem cells (hMSC). Gelatin was modified with pentenoic acid for crosslinking reaction via light controllable thiol-ene reaction, using thiolated 4-arm sPEG as multivalent crosslinker. Due to preservation of the thermo responsive property of gelatin by avoiding chain degradation during modification reaction, this gelatin-based hydrogel system was successfully processed via 3D printing with low polymer concentration. Good cell viability was achieved using hMSC in various concentrations after 3D bioprinting and chondrogenic differentiation showed promising results.}, subject = {Hydrogel}, language = {en} } @article{CzyschMedina‐MontanoZhongetal.2022, author = {Czysch, Christian and Medina-Montano, Carolina and Zhong, Zifu and Fuchs, Alexander and Stickdorn, Judith and Winterwerber, Pia and Schmitt, Sascha and Deswarte, Kim and Raabe, Marco and Scherger, Maximilian and Combes, Francis and De Vrieze, Jana and Kasmi, Sabah and Sandners, Niek N. and Lienenklaus, Stefan and Koynov, Kaloian and R{\"a}der, Hans-Joachim and Lambrecht, Bart N. and David, Sunil A. and Bros, Matthias and Schild, Hansj{\"o}rg and Grabbe, Stephan and De Geest, Bruno G. and Nuhn, Lutz}, title = {Transient Lymph Node Immune Activation by Hydrolysable Polycarbonate Nanogels}, series = {Advanced Functional Materials}, volume = {32}, journal = {Advanced Functional Materials}, number = {35}, doi = {10.1002/adfm.202203490}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-287255}, year = {2022}, abstract = {The development of controlled biodegradable materials is of fundamental importance in immunodrug delivery to spatiotemporally controlled immune stimulation but avoid systemic inflammatory side effects. Based on this, polycarbonate nanogels are developed as degradable micellar carriers for transient immunoactivation of lymph nodes. An imidazoquinoline-type TLR7/8 agonist is covalently conjugated via reactive ester chemistry to these nanocarriers. The nanogels not only provide access to complete disintegration by the hydrolysable polymer backbone, but also demonstrate a gradual disintegration within several days at physiological conditions (PBS, pH 6.4-7.4, 37 °C). These intrinsic properties limit the lifetime of the carriers but their payload can still be successfully leveraged for immunological studies in vitro on primary immune cells as well as in vivo. For the latter, a spatiotemporal control of immune cell activation in the draining lymph node is found after subcutaneous injection. Overall, these features render polycarbonate nanogels a promising delivery system for transient activation of the immune system in lymph nodes and may consequently become very attractive for further development toward vaccination or cancer immunotherapy. Due to the intrinsic biodegradability combined with the high chemical control during the manufacturing process, these polycarbonate-based nanogels may also be of great importance for clinical translation.}, language = {en} } @phdthesis{Macher2021, author = {Macher, Sven}, title = {On the Effects of Moisture on Polymer-Based Electrochromic Devices}, doi = {10.25972/OPUS-24240}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-242407}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2021}, abstract = {The present work builds on a conjugated electrochromic polymer with a highly transmissive and colorless bright state and its application in electrochromic devices. The main body of this work focuses on the investigation of the influence of moisture on electrochromic devices and solutions to overcome possible degradation of these devices due to moisture ingress. Firstly, a series of EDOT derivatives with a terminal double bond in the lateral sidechain to potentially achieve a highly transmissive and fully colorless bright state was investigated. All of the EDOT derivatives were electrochemically polymerized and characterized by means of (in-situ) spectroelectrochemistry. The results highlight the dramatic influence of the terminal double bond on the improved visible light transmittance and color neutrality in the bright state. After detailed evaluation and comparison, the best performing compound, which contains a hexenyl sidechain (PEDOT-EthC6), was scaled-up by changing the deposition technique from an electrochemical to a chemical in-situ polymerization process on a R2R-pilot line in an industrially relevant environment. The R2R-processed PEDOTEthC6 half-cells were characterized in detail and provide enhanced electrochromic properties in terms of visible light transmittance and color neutrality in the bright state as well as short response times, improved contrast ratio, coloration efficiency and cycling stability (10 000 cycles).[21] In a second step, the novel PEDOT-EthC6 electrochromic polymer was combined with a Prussian Blue counter electrode and a solid polymer electrolyte to form an all-solid-sate ECDs based on complementary switching electrodes and PET-ITO as flexible substrates. The fabricated ECDs were optically and spectroelectrochemically characterized. Excellent functionality of the S2S-processed flexible ECDs was maintained throughout 10 000 switching cycles under laboratory conditions. The ECDs offer enhanced electrochromic properties in terms of visible light transmittance change and color neutrality in the bright state as well as contrast ratio, coloration efficiency, cycling stability and fast response times. Furthermore, the final device assembly was transferred from a S2S-process to a continuous R2R-lamination process.[238] In a third step, the PEDOT-EthC6/PB-based ECDs were submitted to conscious environmental aging tests. The emphasis of the research presented in this work, was mainly put at the influence of moisture and possible failure mechanisms regarding the PEDOT-EthC6/PB based ECDs. An intense brown coloration of the electrodes was observed while cycling the ECDs in humid atmospheres (90\% rH) as a major degradation phenomenon. The brown coloration and a thereby accompanied loss of conductivity of the PET-ITO substrates was related to significant degradation of the ITO layers, inserted as the conductive layers in the flexible ECDs. A dissolution of the ITO thin films and formation of metallic indium particles on the surface of the ITO layers was observed that harmed the cycling stability enormously. The conductive layers of the aged ECDs were investigated by XRD, UV-Vis, SEM and spectroelectrochemical measurements and validated the supposed irreversible reduction of the ITO layers.[279] In the absence of reasonable alternatives to PET-ITO for flexible (R2R-processed) ECDs, it is also important to investigate measures to avoid the degradation of ECDs. This is primarily associated with the avoidance of appropriate electrode potentials necessary for ITO reduction in humid atmospheres. As an intrinsic action point, the electrode potentials were investigated via electrochemical measurements in a three-electrode setup of an all-solid-state ECD. Extensive knowledge on the electrode potentials allowed the voltage-induced degradation of the ITO in flexible ECDs to be avoided through the implementation of an unbalanced electrode configuration (charge density ratio of working and counter electrode). It was possible to narrow the overall operational voltage window to an extent in which irreversible ITO reduction no longer occurs. The unbalanced electrode configuration lead to an improved cycling stability without harming other characteristics such as response time and light transmittance change and allows ECD operation in the presence of humidity.[279] The avoidance of the mentioned degradation phenomena is further associated with appropriate sealing methods and materials as well as appropriate electrode and device fabrication processes. Since a variety of sealing materials is commercially available, due to the commercial launch of organic photovoltaic (OPV) and light emitting diodes (OLEDs), the focus in the present work was put to water-free electrode fabrication. As an extrinsic action point, a novel preparation method of a nanoscale PEDOT-EthC6 dispersion based on organic solvents is presented here in a final step. The water-free processing method gives access to straightforward printing and coating processes on flexible PET-ITO substrates and thus represents a promising and simplified alternative to the established PEDOT:PSS. The resulting nano-PEDOT-EthC6 thin films exhibit enhanced color neutrality and transmissivity in the bright state and are comparable to the properties of the in-situ polymerized PEDOT-EthC6 thin films.[280]}, subject = {Elektrochromie}, language = {en} }