@phdthesis{Urlaub2021, author = {Urlaub, Jonas}, title = {Development of analytical methods for the quality assessment of mineral oil based excipients and mechanochemically stressed active pharmaceutical ingredients}, doi = {10.25972/OPUS-24346}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-243465}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2021}, abstract = {For the quality assurance of substances for pharmaceutical use, a variety of analytical techniques are available to address specific analytical problems. In this field of application, liquid chromatography (LC) stands out as the gold standard in the pharmaceutical industry. Various detectors can be employed, which are e.g. based on UV/Vis spectroscopy for the examination of molecules with a chromophore, or mass spectrometry (MS) for structural elucidation of analytes. For the separation of enantiomers, the use of capillary electrophoresis (CE) may be more favorable due to the high separation efficiency and easy-to-use and comparatively inexpensive chiral selectors, in contrast to chiral columns for LC, which are usually very expensive and limited to a restricted number of analytes. For structure elucidation in impurity profiling, one- and multidimensional 1H NMR spectroscopy is a valuable tool as long as the analyte molecule has got nuclei that can be detected, which applies for the magnitude of organic pharmaceutical substances. For the evaluation of the amount of mineral oil aromatic hydrocarbons (MOAH) in various paraffin samples from different suppliers, a straightforward method based on 1H NMR spectroscopy was elaborated. The MOAH/MOSH ratio was used to indicate the amount of MOAH of paraffins and to evaluate the extent of refining. In addition, a representative paraffin sample was measured without sample solvent at high temperatures (about 340 K) to avoid the interfering residual solvent signals in the spectral regions of interest. The results of both methods were in good accordance. Moreover, the 1H NMR results were complemented with the UV measurements from the purity testing of paraffins according to the DAB 8. Correlations of the NMR and UV spectroscopic data indicated a linear relationship of both methods for the determination of MOAH in paraffins. Finally, the 1H NMR data was evaluated by principal component analysis (PCA) to explore differences within the paraffin samples and the spectral regions in the 1H NMR spectrum which are responsible for the formation of groups. It could be found that most variation is due to the MOSH of the paraffins. The PCA model was capable of differentiating between soft, liquid and solid paraffins on the one hand and between natural and synthetic liquid paraffins on the other hand. The impurity profiling of L-ascorbic acid 2-phosphate magnesium (A2PMg) was performed by means of one- and two-dimensional NMR spectroscopy. Several ethylated impurities could be detected, which were likely to be formed during synthesis of A2PMg. The structures of two of the ethylated impurities were identified as ascorbic acid 2-phosphate ethyl ester and ethanol, (residual solvent from synthesis). NMR spectroscopic studies of the fractions obtained from preparative HPLC of A2PMg revealed two additional impurities, which were identified as phosphorylated derivatives of ascorbic acid, ascorbic acid 3,5-phosphate and ascorbic acid 5-phosphate. Solid state mechanochemistry as an alternative approach for stress testing was applied on the drug substances S-Ibuprofen (Ibu) and Clopidogrel (CLP) using a ball mill, in order to study their degradation profile: First, the isomerization of S-Ibu was investigated, which was stressed in the solid state applying several milling frequencies and durations under basic, acidic and neutral conditions. For the separation of Ibu enantiomers, a chiral CE method was developed and validated according to ICH Q2(R1). It was found that S-Ibu is overall very stable to isomerization; it shows minor conversion into the R-enantiomer under basic environment applying long milling times and high frequencies. Last, the degradation profile of clopidogrel hydrogen sulfate (CLP) was investigated, which was stressed in the solid state under various oxidative conditions. An already existing HPLC-UV method was adjusted to sufficiently separate the degradation products, which were characterized by means of UV and MS/(MS) detection. Most of the degradation products identified were already reported to result from conventional CLP stress tests. The degradation profile of CLP was mainly influenced by the material of the milling jar and the type of catalyst used.}, subject = {HPLC}, language = {en} } @phdthesis{Wahl2016, author = {Wahl, Oliver}, title = {Impurity Profiling of Challenging Active Pharmaceutical Ingredients without Chromophore}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-137205}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2016}, abstract = {The impurity profiling of pharmaceutical ingredients can oppose many challenges. The best part of active pharmaceutical ingredients (APIs) and the related substances are detectable by UV detection, a very common detection principle. However, if an API lacks a suitable chromophore other means of detection are necessary. The corona charged aerosol detector (CAD) is a detector capable of detecting substances independent of their chemical structure. This "universal" detector has only one limitation: The analyte has to have a sufficiently low vapor pressure. Another important challenge that comes often together with the lack of a chromophore concerns the separation. These substances (e.g. most amino acids and derivatives) often contain structures that make them difficult to retain on conventional reversed phase columns. Possible solutions to overcome these challenges, like the application of the CAD and the benefit of so-called mixed-mode stationary phases in impurity profiling for pharmacopoeial purposes were explored in this work. The related substances analyzed in this thesis comprise amino acids, inorganic ions, bisphosphonic acids, basic and acidic derivatives of amino acids (esters and amides). The successful development and validation of mixed-mode liquid chromatography methods with CAD detection for carbocisteine and ibandronate sodium might help to increase the acceptance of this versatile detector in the pharmaceutical industry and in official authorities dealing with the determination of related substances. The combination of UV and CAD detection proved very useful during the analysis of Bicisate. Most of the related substances and some unidentified impurities were detectable by CAD whereas a synthesis by-product, a semi-volatile ester, was only detectable in the UV trace. The simple combination covers all relevant impurities in a single analysis. Two truly orthogonal methods regarding separation and detection for the enantiomeric purity of magnesium-L-aspartate helped to find the reason for elevated D aspartic acid content in the drug substance. A very quick and sensitive indirect separation using the OPA derivatization with NAC was developed as a powerful screening tool, whereas the direct separation of D- and L-CBQCA-Asp derivatives confirmed the results. Both methods were optimized in order to do without substances mentioned on the REACH list, like sodium tetraborate which is very frequently applied in standard derivatization protocols and CE separations. The importance of orthogonal detection principles in the determination of related substances of amino acids was discussed in a review article dealing with the revision of amino acid monographs in the Ph. Eur..}, subject = {Chromatographie}, language = {en} } @phdthesis{Ilko2015, author = {Ilko, David}, title = {The use of charged aerosol detection for the analysis of excipients and active pharmaceutical ingredients}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-118377}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {The Corona® charged aerosol detector (CAD) is an aerosol-based detector first de-scribed by Dixon and Peterson in 2002. It is capable of detecting compounds inde-pendent from their physico-chemical properties presumed the analyte is sufficiently non-volatile. Consequently, the CAD is often applied to the analysis of substances that do not possess a suitable UV chromophore. Major drawbacks are however, the detector signal is non-linear and depending on the content of organic solvent in the mobile phase. This thesis tried to explore possible applications of the CAD for pharmaceutical analysis. Therefore, several substances from different compound classes were in-vestigated. Newly developed or existing methods were validated. Thus the perfor-mance of the CAD could be examined. Both assay and impurity determination were evaluated for their compliance with ICH Q2(R1) "Validation of Analytical Proce-dures" and the "Technical Guide for the Elaboration of Monographs". In the course of the establishment of reference substances at the EDQM, a generic screening method for the identification of organic and inorganic pharmaceutical counterions was needed. An HPLC-CAD method developed by Zhang et al. was therefore investigated for its suitability for pharmacopoeial purpose. Method valida-tion was performed. It was found that 23 ions could be separated and detected. Iden-tification was achieved via retention time of an authentic standard of the corre-sponding ions. Alternatively, peak assignment was performed by determination of the exact mass using TOF-MS. Ions could be quantified as impurities or for stoichi-ometric purpose. For the impurity control in topiramate, the performance characterstics of the CAD were compared to that of an ELSD. CAD was superior to ELSD in terms of repeata-bility, sensitivity and linearity. However, impurities could be quantified with satisfac-tory accuracy with both detectors. The application of the ELSD was not feasible due to non-reproducible spike peaks eluting after the principle peak in the chromatogram of the test solution. One of the impurities, topiramate impurity A (diacetonide), gave no or a vastly diminished signal in the ELSD and the CAD, respectively. It is evapo-rated during the detection process due to its relatively high vapor pressure. The re-sponse could be enhanced by a factor of nine via post-column addition of acetoni-trile and a lower nebulizer temperature. As the response of topiramate impurity A was still about thousand-fold lower than the response of all other impurities, its quantification was not feasible. Additionally, the HPLC-CAD was successfully vali-dated as an assay procedure for topiramate. There seems to be a great potential in the application of the CAD to the analysis of excipients as most compounds do not possess a suitable UV chromophore. Here, a simple and rapid HPLC-CAD method for the determination of polidocanol (PD) was developed. The method was successfully validated as a potential assay procedure for the Ph. Eur. as none is described in either of the two PD monographs. The same method was applied to the determination of the PD release from a pharmaceutical polymer matrix. A method for the determination of the fatty acid (FA) composition of polysorbate 80 (PS80) was developed and validated. Using the CAD and mass spectrometry, we were able to identify two new FAs in 16 batches from four manufacturers. All batch-es complied with pharmacopoeial specification. Furthermore, the overall composi-tion of the different PS80 species ("fingerprinting") and the peroxide content were determined. In addition to the chemical characterization, functionality related charac-teristics (FRCs) were determined. Correlations between chemical composition and FRCs were found. The validation data of the above mentioned methods suggests that the CAD repre-sents a viable detection technique for pharmaceutical analysis. The CAD was suffi-ciently sensitive for non-volatile analytes. Impurity control down to concentrations of 0.05 or 0.03\%, as demanded by ICH Q3A (R2), is achievable. However, the response of semi-volatile compounds may be drastically diminished. It could be confirmed that the response of the CAD is linear when the range does not exceed two orders of magnitude. Exceptions may be observed depending on the actual method setup. When the measuring range is sufficiently narrow, quantification can be done using single-point calibration which is common practice in pharmaceutical anlysis. Impuri-ties may also be quantified against a single calibration solution. However, correction factors may be needed and the accuracy is considerably lower compared to an as-say method. If a compound is to be quantified over a large concentration range, log-log transformation of the calibration curve is needed and a decreased accuracy has to be accepted.}, subject = {Analyse}, language = {en} }