@article{AndreskaLueningschroerWolfetal.2023, author = {Andreska, Thomas and L{\"u}ningschr{\"o}r, Patrick and Wolf, Daniel and McFleder, Rhonda L. and Ayon-Olivas, Maurilyn and Rattka, Marta and Drechsler, Christine and Perschin, Veronika and Blum, Robert and Aufmkolk, Sarah and Granado, Noelia and Moratalla, Rosario and Sauer, Markus and Monoranu, Camelia and Volkmann, Jens and Ip, Chi Wang and Stigloher, Christian and Sendtner, Michael}, title = {DRD1 signaling modulates TrkB turnover and BDNF sensitivity in direct pathway striatal medium spiny neurons}, series = {Cell Reports}, volume = {42}, journal = {Cell Reports}, number = {6}, doi = {10.1016/j.celrep.2023.112575}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-349932}, year = {2023}, abstract = {Highlights • Dopamine receptor-1 activation induces TrkB cell-surface expression in striatal neurons • Dopaminergic deficits cause TrkB accumulation and clustering in the ER • TrkB clusters colocalize with cargo receptor SORCS-2 in direct pathway striatal neurons • Intracellular TrkB clusters fail to fuse with lysosomes after dopamine depletion Summary Disturbed motor control is a hallmark of Parkinson's disease (PD). Cortico-striatal synapses play a central role in motor learning and adaption, and brain-derived neurotrophic factor (BDNF) from cortico-striatal afferents modulates their plasticity via TrkB in striatal medium spiny projection neurons (SPNs). We studied the role of dopamine in modulating the sensitivity of direct pathway SPNs (dSPNs) to BDNF in cultures of fluorescence-activated cell sorting (FACS)-enriched D1-expressing SPNs and 6-hydroxydopamine (6-OHDA)-treated rats. DRD1 activation causes enhanced TrkB translocation to the cell surface and increased sensitivity for BDNF. In contrast, dopamine depletion in cultured dSPN neurons, 6-OHDA-treated rats, and postmortem brain of patients with PD reduces BDNF responsiveness and causes formation of intracellular TrkB clusters. These clusters associate with sortilin related VPS10 domain containing receptor 2 (SORCS-2) in multivesicular-like structures, which apparently protects them from lysosomal degradation. Thus, impaired TrkB processing might contribute to disturbed motor function in PD.}, language = {en} } @article{GrotemeyerFischerKoprichetal.2023, author = {Grotemeyer, Alexander and Fischer, Judith F. and Koprich, James B. and Brotchie, Jonathan M. and Blum, Robert and Volkmann, Jens and Ip, Chi Wang}, title = {Inflammasome inhibition protects dopaminergic neurons from α-synuclein pathology in a model of progressive Parkinson's disease}, series = {Journal of Neuroinflammation}, volume = {20}, journal = {Journal of Neuroinflammation}, doi = {10.1186/s12974-023-02759-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-357652}, year = {2023}, abstract = {Neuroinflammation has been suggested as a pathogenetic mechanism contributing to Parkinson's disease (PD). However, anti-inflammatory treatment strategies have not yet been established as a therapeutic option for PD patients. We have used a human α-synuclein mouse model of progressive PD to examine the anti-inflammatory and neuroprotective effects of inflammasome inhibition on dopaminergic (DA) neurons in the substantia nigra (SN). As the NLRP3 (NOD-, LRR- and pyrin domain-containing 3)-inflammasome is a core interface for both adaptive and innate inflammation and is also highly druggable, we investigated the implications of its inhibition. Repeat administration of MCC950, an inhibitor of NLRP3, in a PD model with ongoing pathology reduced CD4\(^+\) and CD8\(^+\) T cell infiltration into the SN. Furthermore, the anti-inflammasome treatment mitigated microglial activation and modified the aggregation of α-synuclein protein in DA neurons. MCC950-treated mice showed significantly less neurodegeneration of DA neurons and a reduction in PD-related motor behavior. In summary, early inflammasome inhibition can reduce neuroinflammation and prevent DA cell death in an α-synuclein mouse model for progressive PD.}, language = {en} } @article{BayerPruckner2023, author = {Bayer, Daniel and Pruckner, Marco}, title = {A digital twin of a local energy system based on real smart meter data}, series = {Energy Informatics}, volume = {6}, journal = {Energy Informatics}, doi = {10.1186/s42162-023-00263-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-357456}, year = {2023}, abstract = {The steadily increasing usage of smart meters generates a valuable amount of high-resolution data about the individual energy consumption and production of local energy systems. Private households install more and more photovoltaic systems, battery storage and big consumers like heat pumps. Thus, our vision is to augment these collected smart meter time series of a complete system (e.g., a city, town or complex institutions like airports) with simulatively added previously named components. We, therefore, propose a novel digital twin of such an energy system based solely on a complete set of smart meter data including additional building data. Based on the additional geospatial data, the twin is intended to represent the addition of the abovementioned components as realistically as possible. Outputs of the twin can be used as a decision support for either system operators where to strengthen the system or for individual households where and how to install photovoltaic systems and batteries. Meanwhile, the first local energy system operators had such smart meter data of almost all residential consumers for several years. We acquire those of an exemplary operator and discuss a case study presenting some features of our digital twin and highlighting the value of the combination of smart meter and geospatial data.}, language = {en} } @article{GruschwitzHartungErguenetal.2023, author = {Gruschwitz, Philipp and Hartung, Viktor and Erg{\"u}n, S{\"u}leyman and Peter, Dominik and Lichthardt, Sven and Huflage, Henner and Hendel, Robin and Pannenbecker, Pauline and Augustin, Anne Marie and Kunz, Andreas Steven and Feldle, Philipp and Bley, Thorsten Alexander and Grunz, Jan-Peter}, title = {Comparison of ultrahigh and standard resolution photon-counting CT angiography of the femoral arteries in a continuously perfused in vitro model}, series = {European Radiology Experimental}, volume = {7}, journal = {European Radiology Experimental}, doi = {10.1186/s41747-023-00398-x}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-357905}, year = {2023}, abstract = {Background With the emergence of photon-counting CT, ultrahigh-resolution (UHR) imaging can be performed without dose penalty. This study aims to directly compare the image quality of UHR and standard resolution (SR) scan mode in femoral artery angiographies. Methods After establishing continuous extracorporeal perfusion in four fresh-frozen cadaveric specimens, photon-counting CT angiographies were performed with a radiation dose of 5 mGy and tube voltage of 120 kV in both SR and UHR mode. Images were reconstructed with dedicated convolution kernels (soft: Body-vascular (Bv)48; sharp: Bv60; ultrasharp: Bv76). Six radiologists evaluated the image quality by means of a pairwise forced-choice comparison tool. Kendall's concordance coefficient (W) was calculated to quantify interrater agreement. Image quality was further assessed by measuring intraluminal attenuation and image noise as well as by calculating signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR). Results UHR yielded lower noise than SR for identical reconstructions with kernels ≥ Bv60 (p < 0.001). UHR scans exhibited lower intraluminal attenuation compared to SR (Bv60: 406.4 ± 25.1 versus 418.1 ± 30.1 HU; p < 0.001). Irrespective of scan mode, SNR and CNR decreased while noise increased with sharper kernels but UHR scans were objectively superior to SR nonetheless (Bv60: SNR 25.9 ± 6.4 versus 20.9 ± 5.3; CNR 22.7 ± 5.8 versus 18.4 ± 4.8; p < 0.001). Notably, UHR scans were preferred in subjective assessment when images were reconstructed with the ultrasharp Bv76 kernel, whereas SR was rated superior for Bv60. Interrater agreement was high (W = 0.935). Conclusions Combinations of UHR scan mode and ultrasharp convolution kernel are able to exploit the full image quality potential in photon-counting CT angiography of the femoral arteries. Relevance statement The UHR scan mode offers improved image quality and may increase diagnostic accuracy in CT angiography of the peripheral arterial runoff when optimized reconstruction parameters are chosen. Key points • UHR photon-counting CT improves image quality in combination with ultrasharp convolution kernels. • UHR datasets display lower image noise compared with identically reconstructed standard resolution scans. • Scans in UHR mode show decreased intraluminal attenuation compared with standard resolution imaging.}, language = {en} } @article{WeisKunde2023, author = {Weis, Patrick P. and Kunde, Wilfried}, title = {Overreliance on inefficient computer-mediated information retrieval is countermanded by strategy advice that promotes memory-mediated retrieval}, series = {Cognitive Research: Principles and Implications}, volume = {8}, journal = {Cognitive Research: Principles and Implications}, doi = {10.1186/s41235-023-00526-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-357892}, year = {2023}, abstract = {With ubiquitous computing, problems can be solved using more strategies than ever, though many strategies feature subpar performance. Here, we explored whether and how simple advice regarding when to use which strategy can improve performance. Specifically, we presented unfamiliar alphanumeric equations (e.g., A + 5 = F) and asked whether counting up the alphabet from the left letter by the indicated number resulted in the right letter. In an initial choice block, participants could engage in one of three cognitive strategies: (a) internal counting, (b) internal retrieval of previously generated solutions, or (c) computer-mediated external retrieval of solutions. Participants belonged to one of two groups: they were either instructed to first try internal retrieval before using external retrieval, or received no specific use instructions. In a subsequent internal block with identical instructions for both groups, external retrieval was made unavailable. The 'try internal retrieval first' instruction in the choice block led to pronounced benefits (d = .76) in the internal block. Benefits were due to facilitated creation and retrieval of internal memory traces and possibly also due to improved strategy choice. These results showcase how simple strategy advice can greatly help users navigate cognitive environments. More generally, our results also imply that uninformed use of external tools (i.e., technology) can bear the risk of not developing and using even more superior internal processing strategies.}, language = {en} } @article{KaufmannGronwaldHeroldetal.2023, author = {Kaufmann, Sebastian and Gronwald, Thomas and Herold, Fabian and Hoos, Olaf}, title = {Heart Rate Variability-Derived Thresholds for Exercise Intensity Prescription in Endurance Sports: A Systematic Review of Interrelations and Agreement with Different Ventilatory and Blood Lactate Thresholds}, series = {Sports Medicine - Open}, volume = {9}, journal = {Sports Medicine - Open}, doi = {10.1186/s40798-023-00607-2}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-357957}, year = {2023}, abstract = {Background Exercise intensities are prescribed using specific intensity zones (moderate, heavy, and severe) determined by a 'lower' and a 'higher' threshold. Typically, ventilatory (VT) or blood lactate thresholds (LT), and critical power/speed concepts (CP/CS) are used. Various heart rate variability-derived thresholds (HRVTs) using different HRV indices may constitute applicable alternatives, but a systematic review of the proximity of HRVTs to established threshold concepts is lacking. Objective This systematic review aims to provide an overview of studies that determined HRVTs during endurance exercise in healthy adults in comparison with a reference VT and/or LT concept. Methods A systematic literature search for studies determining HRVTs in healthy individuals during endurance exercise and comparing them with VTs or LTs was conducted in Scopus, PubMed and Web of Science (until January 2022). Studies claiming to describe similar physiological boundaries to delineate moderate from heavy (HRVTlow vs. VTlow and/or LTlow), and heavy from severe intensity zone (HRVThigh vs. VThigh and/or LThigh) were grouped and their results synthesized. Results Twenty-seven included studies (461 participants) showed a mean difference in relative HR between HRVTlow and VTlow of - 0.6\%bpm in weighted means and 0.02\%bpm between HRVTlow and LTlow. Bias between HR at HRVTlow and VTlow was 1 bpm (limits of agreement (LoA): - 10.9 to 12.8 bpm) and 2.7 bpm (LoA: - 20.4 to 25.8 bpm) between HRVTlow and LTlow. Mean difference in HR between HRVThigh and VThigh was 0.3\%bpm in weighted means and 2.9\%bpm between HRVThigh and LThigh while bias between HR at HRVThigh and VThigh was - 4 bpm (LoA: - 17.9 to 9.9 bpm) and 2.5 bpm (LoA: - 12.1 to 17.1 bpm) between HRVThigh and LThigh. Conclusion HRVTlow seems to be a promising approach for the determination of a 'lower' threshold comparable to VTlow and potentially for HRVThigh compared to VThigh, although the latter needs further empirical evaluation. LoA for both intensity zone boundaries indicates bias of HRVTs on an individual level. Taken together, HRVTs can be a promising alternative for prescribing exercise intensity in healthy, male athletes undertaking endurance activities but due to the heterogeneity of study design, threshold concepts, standardization, and lack of female participants, further research is necessary to draw more robust and nuanced conclusions.}, language = {en} } @article{GruschwitzHartungKleefeldtetal.2023, author = {Gruschwitz, Philipp and Hartung, Viktor and Kleefeldt, Florian and Peter, Dominik and Lichthardt, Sven and Huflage, Henner and Grunz, Jan-Peter and Augustin, Anne Marie and Erg{\"u}n, S{\"u}leyman and Bley, Thorsten Alexander and Petritsch, Bernhard}, title = {Continuous extracorporeal femoral perfusion model for intravascular ultrasound, computed tomography and digital subtraction angiography}, series = {PLoS One}, volume = {18}, journal = {PLoS One}, number = {5}, issn = {1932-6203}, doi = {10.1371/journal.pone.0285810}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-350136}, year = {2023}, abstract = {Objectives We developed a novel human cadaveric perfusion model with continuous extracorporeal femoral perfusion suitable for performing intra-individual comparison studies, training of interventional procedures and preclinical testing of endovascular devices. Objective of this study was to introduce the techniques and evaluate the feasibility for realistic computed tomography angiography (CTA), digital subtraction angiography (DSA) including vascular interventions, and intravascular ultrasound (IVUS). Methods The establishment of the extracorporeal perfusion was attempted using one formalin-fixed and five fresh-frozen human cadavers. In all specimens, the common femoral and popliteal arteries were prepared, introducer sheaths inserted, and perfusion established by a peristaltic pump. Subsequently, we performed CTA and bilateral DSA in five cadavers and IVUS on both legs of four donors. Examination time without unintentional interruption was measured both with and without non-contrast planning CT. Percutaneous transluminal angioplasty and stenting was performed by two interventional radiologists on nine extremities (five donors) using a broad spectrum of different intravascular devices. Results The perfusion of the upper leg arteries was successfully established in all fresh-frozen but not in the formalin-fixed cadaver. The experimental setup generated a stable circulation in each procedure (ten upper legs) for a period of more than six hours. Images acquired with CT, DSA and IVUS offered a realistic impression and enabled the sufficient visualization of all examined vessel segments. Arterial cannulating, percutaneous transluminal angioplasty as well as stent deployment were feasible in a way that is comparable to a vascular intervention in vivo. The perfusion model allowed for introduction and testing of previously not used devices. Conclusions The continuous femoral perfusion model can be established with moderate effort, works stable, and is utilizable for medical imaging of the peripheral arterial system using CTA, DSA and IVUS. Therefore, it appears suitable for research studies, developing skills in interventional procedures and testing of new or unfamiliar vascular devices.}, language = {en} } @article{ReisPfisterKundeetal.2023, author = {Reis, Moritz and Pfister, Roland and Kunde, Wilfried and Foerster, Anna}, title = {Creative thinking does not promote dishonesty}, series = {Royal Society Open Science}, volume = {10}, journal = {Royal Society Open Science}, number = {12}, issn = {2054-5703}, doi = {10.1098/rsos.230879}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-349859}, year = {2023}, abstract = {We assessed the relation of creativity and unethical behaviour by manipulating the thinking style of participants (N = 450 adults) and measuring the impact of this manipulation on the prevalence of dishonest behaviour. Participants performed one of three inducer tasks: the alternative uses task to promote divergent thinking, the remote associates task to promote convergent thinking, or a simple classification task for rule-based thinking. Before and after this manipulation, participants conducted the mind game as a straightforward measure of dishonesty. Dishonest behaviour increased from before to after the intervention, but we found no credible evidence that this increase differed between induced mindsets. Exploratory analyses did not support any relation of trait creativity and dishonesty either. We conclude that the influence of creative thinking on unethical behaviour seems to be more ambiguous than assumed in earlier research or might be restricted to specific populations or contexts.}, language = {en} } @article{ZiebellRodriguesForsteretal.2023, author = {Ziebell, Philipp and Rodrigues, Johannes and Forster, Andr{\´e} and Sanguinetti, Joseph L. and Allen, John JB. and Hewig, Johannes}, title = {Inhibition of midfrontal theta with transcranial ultrasound explains greater approach versus withdrawal behavior in humans}, series = {Brain Stimulation}, volume = {16}, journal = {Brain Stimulation}, number = {5}, doi = {10.1016/j.brs.2023.08.011}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-349890}, pages = {1278-1288}, year = {2023}, abstract = {Highlights • Transcranial ultrasound neuromodulation/stimulation (TUS) is a growing field. • We conducted a double-blind sham-controlled within-subjects large sample TUS study. • Right prefrontal cortex TUS inhibits midfrontal theta electroencephalography (MFT). • TUS MFT inhibition explains greater approach versus withdrawal in a virtual T-maze. • This distinct TUS-MFT-behavior link merits future basic and applied research. Abstract Recent reviews highlighted low-intensity transcranial focused ultrasound (TUS) as a promising new tool for non-invasive neuromodulation in basic and applied sciences. Our preregistered double-blind within-subjects study (N = 152) utilized TUS targeting the right prefrontal cortex, which, in earlier work, was found to positively enhance self-reported global mood, decrease negative states of self-reported emotional conflict (anxiety/worrying), and modulate related midfrontal functional magnetic resonance imaging activity in affect regulation brain networks. To further explore TUS effects on objective physiological and behavioral variables, we used a virtual T-maze task that has been established in prior studies to measure motivational conflicts regarding whether participants execute approach versus withdrawal behavior (with free-choice responses via continuous joystick movements) while allowing to record related electroencephalographic data such as midfrontal theta activity (MFT). MFT, a reliable marker of conflict representation on a neuronal level, was of particular interest to us since it has repeatedly been shown to explain related behavior, with relatively low MFT typically preceding approach-like risky behavior and relatively high MFT typically preceding withdrawal-like risk aversion. Our central hypothesis is that TUS decreases MFT in T-maze conflict situations and thereby increases approach and reduces withdrawal. Results indicate that TUS led to significant MFT decreases, which significantly explained increases in approach behavior and decreases in withdrawal behavior. This study expands TUS evidence on a physiological and behavioral level with a large sample size of human subjects, suggesting the promise of further research based on this distinct TUS-MFT-behavior link to influence conflict monitoring and its behavioral consequences. Ultimately, this can serve as a foundation for future clinical work to establish TUS interventions for emotional and motivational mental health.}, language = {en} } @article{TranGiaDenisBacelarFerreiraetal.2023, author = {Tran-Gia, Johannes and Denis-Bacelar, Ana M. and Ferreira, Kelley M. and Robinson, Andrew P. and Bobin, Christophe and Bonney, Lara M. and Calvert, Nicholas and Collins, Sean M. and Fenwick, Andrew J. and Finocchiaro, Domenico and Fioroni, Federica and Giannopoulou, Katerina and Grassi, Elisa and Heetun, Warda and Jewitt, Stephanie J. and Kotzasarlidou, Maria and Ljungberg, Michael and Louren{\c{c}}o, Val{\´e}rie and McGowan, Daniel R. and Mewburn-Crook, Jamie and Sabot, Benoit and Scuffham, James and Sj{\"o}green Gleisner, Katarina and Solc, Jaroslav and Thiam, Cheick and Tipping, Jill and Wevrett, Jill and Lassmann, Michael}, title = {On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT/CT calibration: a European multi-centre evaluation}, series = {EJNMMI Physics}, volume = {10}, journal = {EJNMMI Physics}, organization = {The MRT Dosimetry Collaboration}, doi = {10.1186/s40658-023-00582-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-357740}, year = {2023}, abstract = {Introduction Commissioning, calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple sources of uncertainty, many of which can be overcome by using traceable, sealed, long-lived surrogate sources containing a radionuclide of comparable energies and emission probabilities. This study presents the results of a quantitative SPECT/CT imaging comparison exercise performed within the MRTDosimetry consortium to assess the feasibility of using 133Ba as a surrogate for 131I imaging. Materials and methods Two sets of four traceable 133Ba sources were produced at two National Metrology Institutes and encapsulated in 3D-printed cylinders (volume range 1.68-107.4 mL). Corresponding hollow cylinders to be filled with liquid 131I and a mounting baseplate for repeatable positioning within a Jaszczak phantom were also produced. A quantitative SPECT/CT imaging comparison exercise was conducted between seven members of the consortium (eight SPECT/CT systems from two major vendors) based on a standardised protocol. Each site had to perform three measurements with the two sets of 133Ba sources and liquid 131I. Results As anticipated, the 131I pseudo-image calibration factors (cps/MBq) were higher than those for 133Ba for all reconstructions and systems. A site-specific cross-calibration reduced the performance differences between both radionuclides with respect to a cross-calibration based on the ratio of emission probabilities from a median of 12-1.5\%. The site-specific cross-calibration method also showed agreement between 133Ba and 131I for all cylinder volumes, which highlights the potential use of 133Ba sources to calculate recovery coefficients for partial volume correction. Conclusion This comparison exercise demonstrated that traceable solid 133Ba sources can be used as surrogate for liquid 131I imaging. The use of solid surrogate sources could solve the radiation protection problem inherent in the preparation of phantoms with 131I liquid activity solutions as well as reduce the measurement uncertainties in the activity. This is particularly relevant for stability measurements, which have to be carried out at regular intervals.}, language = {en} }