@article{DarwishAttia2012, author = {Darwish, Hany W. and Attia, Mohamed I.}, title = {New spectrofluorimetric methods for determination of melatonin in the presence of N-{2-[1-({3-[2-(acetylamino)ethyl]-5-methoxy-1H-indol-2-yl}methyl)-5-methoxy-1H-indol-3-yl]ethyl} acetamide: a contaminant in commercial melatonin preparations}, series = {Chemistry Central Journal}, volume = {6}, journal = {Chemistry Central Journal}, number = {36}, doi = {10.1186/1752-153X-6-36}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-134606}, year = {2012}, abstract = {Background: Melatonin (MLT) has many health implications, therefore it is of valuable importance to develop specific analytical methods for determination of MLT in the presence of its main contaminant, N-{2-[1-({3-[2(acetylamino)ethyl]-5-methoxy-1H-indol-2-yl}methyl)-5-methoxy-1H-indol-3-yl]ethyl}acetamide (10). For development of these analytical methods, compound 10 had to be prepared in an adequate amount. Results: Compound 10 was synthesized in six steps starting from 5-methoxyindole-2-carboxylic acid (1). Analytical performance of the proposed spectrofluorimetric methods was statistically validated with respect to linearity, accuracy, precision and specificity. The proposed methods were successfully applied for the assay of MLT in laboratory prepared mixtures containing up to 60 \% of compound 10 and in commercial MLT tablets with recoveries not less than 99.00 \%. No interference was observed from common pharmaceutical additives and the results were favorably compared with those obtained by a reference method. Conclusions: This work describes simple, sensitive, and reliable second derivative spectrofluorimetric method in addition to two multivariate calibration methods, principal component regression (PCR) and partial least square (PLS), for the determination of MLT in the presence of compound 10.}, language = {en} } @article{DarwishAttia2012, author = {Darwish, Hany W. and Attia, Mohamed I.}, title = {New spectrofluorimetric methods for determination of melatonin in the presence of N-{2-[1-({3-[2-(acetylamino)ethyl]-5-methoxy-1H-indol-2-yl}methyl)-5-methoxy-1H-indol-3-yl]- ethyl}acetamide: a contaminant in commercial melatonin preparations}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-78234}, year = {2012}, abstract = {Background: Melatonin (MLT) has many health implications, therefore it is of valuable importance to develop specific analytical methods for determination of MLT in the presence of its main contaminant, N-{2-[1-({3-[2-(acetylamino)ethyl]-5-methoxy-1H-indol-2-yl}methyl)-5-methoxy-1H-indol-3-yl]ethyl}acetamide (10). For development of these analytical methods, compound 10 had to be prepared in an adequate amount. Results: Compound 10 was synthesized in six steps starting from 5-methoxyindole-2-carboxylic acid (1). Analytical performance of the proposed spectrofluorimetric methods was statistically validated with respect to linearity, accuracy, precision and specificity. The proposed methods were successfully applied for the assay of MLT in laboratory prepared mixtures containing up to 60 \% of compound 10 and in commercial MLT tablets with recoveries not less than 99.00 \%. No interference was observed from common pharmaceutical additives and the results were favorably compared with those obtained by a reference method. Conclusions: This work describes simple, sensitive, and reliable second derivative spectrofluorimetric method in addition to two multivariate calibration methods, principal component regression (PCR) and partial least square (PLS), for the determination of MLT in the presence of compound 10.}, subject = {Chemie}, language = {en} }