@phdthesis{Kleineisel2024, author = {Kleineisel, Jonas}, title = {Variational networks in magnetic resonance imaging - Application to spiral cardiac MRI and investigations on image quality}, doi = {10.25972/OPUS-34737}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-347370}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2024}, abstract = {Acceleration is a central aim of clinical and technical research in magnetic resonance imaging (MRI) today, with the potential to increase robustness, accessibility and patient comfort, reduce cost, and enable entirely new kinds of examinations. A key component in this endeavor is image reconstruction, as most modern approaches build on advanced signal and image processing. Here, deep learning (DL)-based methods have recently shown considerable potential, with numerous publications demonstrating benefits for MRI reconstruction. However, these methods often come at the cost of an increased risk for subtle yet critical errors. Therefore, the aim of this thesis is to advance DL-based MRI reconstruction, while ensuring high quality and fidelity with measured data. A network architecture specifically suited for this purpose is the variational network (VN). To investigate the benefits these can bring to non-Cartesian cardiac imaging, the first part presents an application of VNs, which were specifically adapted to the reconstruction of accelerated spiral acquisitions. The proposed method is compared to a segmented exam, a U-Net and a compressed sensing (CS) model using qualitative and quantitative measures. While the U-Net performed poorly, the VN as well as the CS reconstruction showed good output quality. In functional cardiac imaging, the proposed real-time method with VN reconstruction substantially accelerates examinations over the gold-standard, from over 10 to just 1 minute. Clinical parameters agreed on average. Generally in MRI reconstruction, the assessment of image quality is complex, in particular for modern non-linear methods. Therefore, advanced techniques for precise evaluation of quality were subsequently demonstrated. With two distinct methods, resolution and amplification or suppression of noise are quantified locally in each pixel of a reconstruction. Using these, local maps of resolution and noise in parallel imaging (GRAPPA), CS, U-Net and VN reconstructions were determined for MR images of the brain. In the tested images, GRAPPA delivers uniform and ideal resolution, but amplifies noise noticeably. The other methods adapt their behavior to image structure, where different levels of local blurring were observed at edges compared to homogeneous areas, and noise was suppressed except at edges. Overall, VNs were found to combine a number of advantageous properties, including a good trade-off between resolution and noise, fast reconstruction times, and high overall image quality and fidelity of the produced output. Therefore, this network architecture seems highly promising for MRI reconstruction.}, subject = {Kernspintomografie}, language = {en} } @phdthesis{Dietrich2024, author = {Dietrich, Philipp}, title = {Traveling Wave Magnetic Particle Imaging: Visuelle Stenosequantifizierung und Perkutane Transluminale Angioplastie im Gef{\"a}ßmodell}, doi = {10.25972/OPUS-35251}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-352517}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2024}, abstract = {Magnetic Particle Imaging (MPI) ist ein innovatives tomographisches Bildgebungs­verfahren, mit dem Tracerpartikel {\"a}ußerst sensitiv und schnell mehrdimensional abgebildet werden k{\"o}nnen. Die Methode basiert auf der nichtlinearen Magnetisierungs­antwort superparamagnetischer Eisenoxidnanopartikel (SPION) in einem Messpunkt, welcher ein Messvolumen rastert. In vorliegender Arbeit wurde das sog. Traveling Wave MPI (TWMPI) Verfahren eingesetzt, wodurch im Vergleich zu konventionellen MPI-Scannern ein gr{\"o}ßeres Field of View (FOV) und eine geringere Latenz bis zur Bildanzeige erreicht werden konnte. TWMPI weist einige f{\"u}r medizinische Zwecke vielversprechende Eigenschaften auf: Es liefert zwei- und dreidimensionale Bildrekonstruktionen in Echtzeit mit hoher zeitlicher und r{\"a}umlicher Aufl{\"o}sung. Dabei ist die Bildgebung von Grund auf hintergrundfrei und erfordert keinerlei ionisierende Strahlung. Zudem ist die Technik {\"a}ußerst sensitiv und kann SPION-Tracer noch in mikromolaren Konzentrationen detektieren. Ziel dieser Arbeit war es daher zu untersuchen, inwiefern es mittels TWMPI m{\"o}glich ist, k{\"u}nstliche Stenosen im Gef{\"a}ßmodell visuell in Echtzeit darzustellen und quantitativ zu beurteilen sowie {\"u}berdies eine perkutane transluminale Angioplastie (PTA) im Gef{\"a}ßmodell unter TWMPI-Echtzeit-Bildgebung durchzuf{\"u}hren. Alle Experimente wurden in einem speziell angefertigten TWMPI-Scanner durchgef{\"u}hrt (JMU W{\"u}rzburg, Experimentelle Physik V (Biophysik), FOV: 65 x 29 x 29 mm³, Aufl{\"o}sung: ca. 1.5 - 2 mm). Die Lumen-Darstellungen erfolgten mittels des SPION-Tracers Ferucarbotran in einer Verd{\"u}nnung von 1 : 50 (entspr. 10 mmol [Fe]/l). Das PTA-Instrumentarium wurde mit eigens hergestelltem ferucarbotran­haltigem Lack (100 mmol [Fe]/l) markiert. F{\"u}r die verschiedenen Teilexperimente wurden den jeweiligen speziellen Anforderungen entsprechend mehrere Gef{\"a}ßmodelle handgefertigt. F{\"u}r die visuelle Stenosequantifizierung wurden f{\"u}nf starre Stenosephantome unterschiedlicher Stenosierung (0\%, 25\%, 50\%, 75\%, 100\%) aus Polyoxymethylen her­gestellt (l: 40 mm, ID: 8 mm). Die Gef{\"a}ßmodelle wurden mehrfach zentral im FOV platz­iert und das stenosierte Lumen mittels sog. Slice-Scanning Modus (SSM, Einzel­aufnahme inkl. 10 Mittelungen: 200 ms, Bildfrequenz: 5 Bilder pro Sekunde, Latenz: ca. 100 ms) als zweidimensionale Quasi-Projektionen abgebildet. Diese Aufnahmen (n = 80, 16 je Phantom) wurden mit einer ein­heitlichen Grauskalierung versehen und anschließend entsprechend den NASCET-Kriterien visuell ausgewertet. Alle achtzig Aufnahmen waren unabh{\"a}ngig vom Stenosegrad aufgrund einheitlicher Fensterung sowie konstanter Scannerparameter untereinander gut vergleichbar. Niedrig­gradige Stenosen konnten insgesamt genauer abgebildet werden als h{\"o}hergradige, was sich neben der subjektiven Bildqualit{\"a}t auch in geringeren Standardabweichungen zeigte (0\%: 3.70 \% ± 2.71, 25\%: 18.64 \% ± 1.84, 50\%: 52.82 \% ± 3.66, 75\%: 77.84 \% ± 14.77, 100\%: 100 \% ± 0). Mit zunehmendem Stenosegrad kam es vermehrt zu geometrischen Ver­zerrungen im Zentrum, sodass bei den 75\%-Stenosen eine breitere Streuung der Messwerte mit einer h{\"o}heren Standardabweichung von 14.77\% einherging. Leichte, randst{\"a}ndige Artefakte konnten bei allen Datens{\"a}tzen beobachtet werden. F{\"u}r die PTA wurden drei interaktive Gef{\"a}ßmodelle aus Polyvinylchlorid (l: 100 mm, ID: 8 mm) mit zu- und abf{\"u}hrendem Schlauchsystem entwickelt, welche mittels Kabelband von außen hochgradig eingeengt werden konnten. Analog zu einer konventionellen PTA mittels r{\"o}ntgenbasierter digitaler Subtraktionsangiographie (DSA), wurden alle erforder­lichen Arbeitsschritte (Gef{\"a}ßdarstellung, Drahtpassage, Ballonplatzierung, Angioplastie, Erfolgskontrolle) unter (TW)MPI-Echtzeit-Bildgebung (Framerate: 2 - 4 FPS, Latenz: ca. 100 ms) abgebildet bzw. durchgef{\"u}hrt. Im Rahmen der PTA war eine Echtzeit-Visualisierung der Stenose im Gef{\"a}ßmodell durch Tracer-Bolusgabe sowie die F{\"u}hrung des markierten Instrumentariums zum Zielort m{\"o}glich. Die Markierung der Instrumente hielt der Beanspruchung w{\"a}hrend der Prozedur stand und erm{\"o}glichte eine genaue Platzierung des Ballonkatheters. Die Stenose konnte mittels Angioplastie-Ballons unter Echtzeit-Darstellung gesprengt werden und der Interventionserfolg im Anschluss durch erneute Visualisierung des Lumens validiert werden. Insgesamt zeigt sich MPI somit als ad{\"a}quate Bildgebungstechnik f{\"u}r die beiden in der Fragestellung bzw. Zielsetzung definierten experimentellen Anwendungen. Stenosen im Gef{\"a}ßmodell konnten erfolgreich in Echtzeit visualisiert und bildmorphologisch nach NASCET-Kriterien quantifiziert werden. Ebenso war eine PTA im Gef{\"a}ßmodell unter TWMPI-Echtzeit-Bildgebung machbar. Diese Ergebnisse unter­streichen das grundlegende Potenzial von MPI f{\"u}r medizinische Zwecke. Um zu den bereits etablierten Bildgebungsmethoden aufzuschließen, ist jedoch weitere Forschung im Bereich der Scanner-Hard- und -Software sowie bez{\"u}glich SPION-Tracern n{\"o}tig.}, subject = {Medizinische Radiologie}, language = {de} } @phdthesis{Pannenbecker2024, author = {Pannenbecker, Pauline Luisa}, title = {Vergleich von Dual- und Single-Source Dual-Energy CT in der Diagnostik der akuten Lungenarterienembolie hinsichtlich Bildqualit{\"a}t und Strahlendosis}, doi = {10.25972/OPUS-35206}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-352064}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2024}, abstract = {Hintergrund: Die CT-Pulmonalisangiographie (CTPA) ist diagnostischer Goldstandard der Diagnostik der Lungenarterienembolie (LAE). Durch Dual-Energy CT (DECT) k{\"o}nnen mithilfe von Joddistributionskarten LAEs auf Segment- und Subsegmentebene besser detektiert werden. Neben der etablierten Dual-Source-Technik erm{\"o}glicht ein Split-Filter eine DECT-Akquisition mit Single-Source-Scannern. Ein solcher SF-DECT-Scanner sollte hinsichtlich der Bildqualit{\"a}t sowie der Strahlendosis mit einem etabliertem DS-DECT-Ger{\"a}t verglichen werden. Material und Methoden: Insgesamt wurden 135 Patienten eingeschlossen, die eine CTPA erhielten: 68 erhielten einen DS-DECT-Scan mit 90/Sn150 kV und 67 einen SF-DECT-Scan mit Au/Sn120 kV. F{\"u}r beide Protokolle wurden farbkodierte Joddistributionskarten erstellt. Die objektive (CT-Abschw{\"a}chung in relevanten Gef{\"a}ßen in HU, Signal-Rausch-Verh{\"a}ltnis (SNR), Kontrast-Rausch-Verh{\"a}ltnis (CNR), perfused blood volume (PBV)) und subjektive Bildqualit{\"a}t (2 Befunder (B), 5-Punkte-Likert-Skala) sowie Dosisparameter wurden erhoben und verglichen. Ergebnisse: Alle CTPAs waren von diagnostischer Qualit{\"a}t. Ihre subjektive Bildqualit{\"a}t wurde in 80,9/82,4\% (B1/B2) der DS-DECT und in 77,6/76,1\% der SF-DECT als exzellent oder gut bewertet. Die subjektive Bildqualit{\"a}t der Joddistributionskarten der SF-DECT wurde von beiden Befundern als schlechter beurteilt. Die HU-Werte der relevanten Gef{\"a}ße unterschieden sich nicht signifikant (p>0.05), SNR und CNR der SF-Gruppe waren in zentralen Gef{\"a}ßen jedoch h{\"o}her (p<0.05); die PBV-Werte der SF-Gruppe waren teils h{\"o}her (p<0.05). Alle erhobenen Dosisparameter waren in der SF-Gruppe h{\"o}her (p<0,05). Konklusion: In der diagnostischen Abkl{\"a}rung eines V.a. eine akute LAE erm{\"o}glicht der Einsatz eines Split-Filters an einem Single-Source-CT-Scanner eine Dual-Energy-Untersuchung. Dies geht im Vergleich zu etablierten DS-Scannern jedoch mit einer schlechteren Qualit{\"a}t der Joddistributionskarten und einer h{\"o}heren Strahlendosis einher.}, subject = {Lungenembolie}, language = {de} } @phdthesis{Laqua2024, author = {Laqua, Caroline}, title = {Association of myocardial tissue characteristics and functional outcome in biopsy-verified myocarditis assessed by cardiac magnetic resonance imaging}, doi = {10.25972/OPUS-36390}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-363903}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2024}, abstract = {The relation between LV function and cardiac MRI tissue characteristics in separate myocardial segments and their change over time has yet to be explored in myocarditis. Thus, our research aimed to investigate possible associations between global and regional myocardial T1 and T2 times and peak strain in patients with suspected myocarditis. From 2012 to 2015, 129 patients with clinically suspected myocarditis of the prospective, observational MyoRacer-Trial underwent systematic biventricular EMB at baseline and cardiac MRI at baseline and after three months as a follow-up. We divided the LV myocardium into 17 segments and estimated the segmental myocardial strain using FT. We registered T1 and T2 maps to the cine sequences and transferred the segmentations used for FT to ensure conformity of the myocardial segments. Multi-level multivariable linear mixed effects regression was applied to investigate the relation of segmental myocardial strain to relaxation times and their respective change from baseline to follow-up. We found a significant improvement in myocardial peak strain from baseline to follow-up (p < 0.001; all p-values given for likelihood ratio tests) and significant associations between higher T1 and T2 times and lower segmental myocardial peak strain (p ranging from < 0.001 to 0.049). E.g., regression coefficient (Reg. coef.) for segmental radial peak strain in short axis view (SRPS_SAX) and T1 time: -1.9, 95\% CI (-2.6;-1.2) \%/100 ms, p < 0.001. A decrease in T1 and T2 times from baseline to follow-up was also significantly related to a recovery of segmental peak strains (p ranging from < 0.001 to 0.050). E.g., Reg. coef. for SRPS_SAX per ΔT1: -1.8, 95\% CI (-2.5;-1.0) \%/100 ms, p < 0.001. Moreover, the higher the baseline T1 time, the more substantial the functional recovery from baseline to follow-up (p ranging from 0.004 to 0.042, e.g., for SRPS_SAX: Reg. coef. 1.3, 95\% CI (0.4;2.1) \%/100 ms, p 0.004). We did not find an effect modification by the presence of myocarditis in the EMB (p > 0.1). Our cross-sectional and longitudinal analyses provide evidence of dose-dependent correlations between T1 and T2 relaxation times and myocardial peak strain in patients with clinical presentation of myocarditis, regardless of the EMB result. Thus, assessing strain values and mapping relaxation times helps estimate the functional prognosis in patients with clinically suspected myocarditis.}, subject = {Myokarditis}, language = {en} } @phdthesis{Heuer2023, author = {Heuer, Anjana}, title = {Aktive Gefäßverschlusssysteme in der interventionellen Radiologie: Sicherheit und Effektivität des neuartigen Doppelclip-basierten Celt ACD® Systems}, doi = {10.25972/OPUS-30098}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300986}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2023}, abstract = {Mit steigender Nachfrage an minimal-invasiven Therapieoptionen w{\"a}chst auch das Interesse an innovativen Alternativen im Bereich des arteriellen Gef{\"a}ßverschlusses nach PVI. Ziel der vorliegenden Arbeit war es, die Effektivit{\"a}t und Sicherheit eines neu auf dem Markt befindlichen, Doppelclip-basierten aktiven VVS zu pr{\"u}fen. Eine hohe technische Erfolgsrate von 98,8 \% bei einer geringen Komplikationsrate von 3,6 \% wurde verzeichnet. Bei Anwesenheit der Komorbidit{\"a}ten Dm und CNI 5 zeigte sich eine signifikante Assoziation zu einem vermehrten Auftreten von Komplikationen. Ein nachgewiesener signifikanter Zusammenhang bestand zudem zwischen einem erh{\"o}hten Kalzifikationsgrad der Punktionsstelle bei Vorliegen einer pAVK und eines Dm. Eine erh{\"o}hte Gef{\"a}ßrigidit{\"a}t aufgrund von Komorbidit{\"a}ten und vaskul{\"a}ren Kalzifikationen, intrinsische Fremdk{\"o}rperreaktionen, vasoregulatorische Reaktionen oder Produktversagen bieten hypothetische Erkl{\"a}rungsans{\"a}tze f{\"u}r die einzelnen komplikativen F{\"a}lle. Die Nutzung des VVS in spezifischen, bisher nicht beschriebenen Situationen (Unterdimensionierung, Anwendung nach Gef{\"a}ßpunktionen mit Zugangsschleusen bis 9F, antegrade Punktionsrichtung, anspruchsvolle Eingriffe multimorbider Patienten mit komplexem vaskul{\"a}rem Status) erwies sich als suffizient. Zur Pr{\"a}vention schwerwiegender Komplikationen w{\"a}hrend zuk{\"u}nftiger Interventionen wurden die Empfehlung ausgesprochen, eine Durchleuchtungsaufnahme zur Lagekontrolle vor Implantation des proximalen Clips anzufertigen. Eine speziell f{\"u}r Gef{\"a}ßverschl{\"u}sse nach antegrader Punktion konzipierte Zugangsschleuse k{\"o}nnte das Abknicken von Zugangsschleusen bei VVS Applikation verhindern. Zusammenfassend kann das untersuchte aktive VVS mit einzigartigem Wirkmechanismus und spezifischen Design als effektiv und sicher angesehen werden.}, subject = {Gef{\"a}ßverschluss}, language = {de} } @phdthesis{Portmann2023, author = {Portmann, Johannes}, title = {Accelerated inversion recovery MRI of the myocardium using spiral acquisition}, doi = {10.25972/OPUS-30282}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-302822}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2023}, abstract = {This work deals with the acceleration of cardiovascular MRI for the assessment of functional information in steady-state contrast and for viability assessment during the inversion recovery of the magnetization. Two approaches are introduced and discussed in detail. MOCO-MAP uses an exponential model to recover dynamic image data, IR-CRISPI, with its low-rank plus sparse reconstruction, is related to compressed sensing. MOCO-MAP is a successor to model-based acceleration of parametermapping (MAP) for the application in the myocardial region. To this end, it was augmented with a motion correction (MOCO) step to allow exponential fitting the signal of a still object in temporal direction. Iteratively, this introduction of prior physical knowledge together with the enforcement of consistency with the measured data can be used to reconstruct an image series from distinctly shorter sampling time than the standard exam (< 3 s opposed to about 10 s). Results show feasibility of the method as well as detectability of delayed enhancement in the myocardium, but also significant discrepancies when imaging cardiac function and artifacts caused already by minor inaccuracy of the motion correction. IR-CRISPI was developed from CRISPI, which is a real-time protocol specifically designed for functional evaluation of image data in steady-state contrast. With a reconstruction based on the separate calculation of low-rank and sparse part, it employs a softer constraint than the strict exponential model, which was possible due to sufficient temporal sampling density via spiral acquisition. The low-rank plus sparse reconstruction is fit for the use on dynamic and on inversion recovery data. Thus, motion correction is rendered unnecessary with it. IR-CRISPI was equipped with noise suppression via spatial wavelet filtering. A study comprising 10 patients with cardiac disease show medical applicability. A comparison with performed traditional reference exams offer insight into diagnostic benefits. Especially regarding patients with difficulty to hold their breath, the real-time manner of the IR-CRISPI acquisition provides a valuable alternative and an increase in robustness. In conclusion, especially with IR-CRISPI in free breathing, a major acceleration of the cardiovascular MR exam could be realized. In an acquisition of less than 100 s, it not only includes the information of two traditional protocols (cine and LGE), which take up more than 9.6 min, but also allows adjustment of TI in retrospect and yields lower artifact level with similar image quality.}, subject = {Kernspintomografie}, language = {en} } @phdthesis{Laas2023, author = {Laas, Susanne Franziska}, title = {Stellenwert der kontrastmittelverst{\"a}rkten MRT bei traumatischen Verletzungen und posttraumatischen Ver{\"a}nderungen an der Hand}, doi = {10.25972/OPUS-29937}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-299370}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2023}, abstract = {Die vorliegende Arbeit hat zum Ziel, den Stellenwert von kontrastverst{\"a}rkten MR- Sequenzen in der bildgebenden Diagnostik von Hand und Fingern zu untersuchen. Denn trotz einer breiten empirischen Anwendung von gadoliniumhaltigen Kontrastmitteln im europ{\"a}ischen Raum besteht keine ausreichende wissenschaftliche Datengrundlage zur kontrastverst{\"a}rkten Hand-MRT nach einem Trauma. Zu diesem Zweck wurden zwischen Januar 2016 und August 2018 am Rh{\"o}n-Klinikum Campus Bad Neustadt 165 MRT-Untersuchungen von distalem Unterarm, Karpus, Metakarpus und/oder Fingern selektiert. Einschlusskriterien waren eine positive Traumaanamnese, standardisierte MRT-Sequenzen und das Fehlen von Kontraindikationen. Zur Definition eines diagnostischen Referenzstandards wurden alle F{\"a}lle vorab durch einen Senior-Investigator mit 36 Jahren Erfahrung in muskuloskelettaler Radiologie analysiert. F{\"u}r die Bildevaluation wurden aus jeder MRT-Untersuchung zwei Datens{\"a}tze erstellt, wobei der erste Datensatz nur die nativen Sequenzen (PD / T2 FSE fs und T1 FSE ) und der zweite Datensatz zus{\"a}tzlich zu eine kontrastverst{\"a}rkte Sequenz als T1 FSE fs nach Gadolinium-Applikation enthielt. Als Observer fungierten zwei radiologische Fach- bzw. Ober{\"a}rzte des Universit{\"a}tsklinikum W{\"u}rzburgs. In der vorliegenden Studie wurde ein diagnostisch relevantes Kontrastmittelenhancement an Patienten mit traumatischen Handverletzungen nachgewiesen. Der Kontrastmitteleffekt war mit subjektiven und objektiven Messgr{\"o}ßen statistisch signifikant bei L{\"a}sionen der Ligamente und an den ligament{\"a}hnlichen Insertionen des ulnaren TFCC-Abschnittes. Als Erkl{\"a}rung f{\"u}r das Kontrastmittelenhancement in der MRT dient in erster Linie die bereits fr{\"u}her beschriebene Hyper{\"a}mie, die posttraumatisch am Traumaort mit Ausgang von der Synovialis entsteht. Anhand der Studienergebnisse kann die Empfehlung ausgesprochen werden, in der MRT-Diagnostik von traumatischen L{\"a}sionen der Hand immer dann intraven{\"o}ses Kontrastmittel auf Gadolinium-Basis zu verabreichen, wenn am vermuteten L{\"a}sionsort der T2-Kontrast f{\"u}r eine sichere Diagnose unzureichend ist.}, subject = {Intraven{\"o}se Applikation}, language = {de} } @phdthesis{KlinnertVlachopoulou2023, author = {Klinnert Vlachopoulou, Cristina Maria}, title = {Comparison between Dual-Energy-CT perfusion imaging and perfusion-weighted SElf-gated Non-Contrast-Enhanced FUnctional MR imaging of the lung in patients with pulmonary artery embolism}, doi = {10.25972/OPUS-31303}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-313034}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2023}, abstract = {Pulmonary artery embolism (PE) is a common condition and an even more common clinical suspect. The computed tomography pulmonary angiogram (CTPA) is the main medical imaging tool used to diagnose a suspected case of PE. To gain a better impression of the effects of a PE on the perfusion and hence the gas exchange, a functional imaging method is beneficial. One approach for functional imaging using radiation exposure is the generation of color-coded iodine perfusion maps acquired by Dual-Energy Computed Tomography (DECT), which enable the detection of perfusion defects in the pulmonary parenchyma. In contrast to the existing approach of DECT with iodine color-coded maps, the SElf-gated Non-Contrast-Enhanced FUnctional Lung (SENCEFUL) MRI technique offers the possibility to interpret perfusion maps without any radiation exposure or application of contrast agents. The measurement in SENCEFUL MRI can be performed during conditions of free breathing and without electrocardiogram triggering. The purpose of this study was to determine whether PE can be diagnosed on the basis of visible perfusion defects in the perfusion maps of SENCEFUL MRI and in the iodine-coded maps of DECT and to compare the diagnostic performance of these methods. Both SENCEFUL-MRI and iodine distribution maps from DECT have been compared with the CTPA of ten patients with PE. Additionally, the functional images were compared with each other on a per-patient basis. The iodine perfusion maps of DECT had a sensitivity of 84.2 \% and specificity of 65.2 \% for the diagnosis of PE. The SENCEFUL technique in MRI showed a sensitivity of 78.9 \% and a specificity of 26.1 \%. When comparing the whole lung depicted in both series of functional images, the main perfusion defect location matched in four of ten patients (40 \%). In conclusion, this work found that DECT iodine maps have higher sensitivity and specificity in the diagnosis of pulmonary embolism compared with SENCEFUL MRI.}, subject = {Lungenembolie}, language = {en} } @phdthesis{Lucius2023, author = {Lucius, Leonie Johanna}, title = {Die endovaskul{\"a}re Therapie der malignen unteren Einflussstauung mit dem Sinus-XL® Stent}, doi = {10.25972/OPUS-32669}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-326691}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2023}, abstract = {Die interventionelle Radiologie hat sich in den letzten Jahrzehnten zunehmend auf palliativmedizinische sowie onkologische Bereiche ausgeweitet und kann durch minimal-invasive Therapieoptionen gerade in vulnerablen Patientenkollektiven attraktive Behandlungsm{\"o}glichkeiten zur Verf{\"u}gung stellen. Die tumorbedingte untere Einflussstauung ist ein seltenes Krankheitsbild und stellt eine schwere symptomatische Komplikation einer malignen Grunderkrankung dar. Dabei kommt es im Rahmen dieser Grunderkrankung durch die Prim{\"a}rtumormasse oder Metastasen zu extrinsischer Kompression der Vena cava inferior (VCI), Gef{\"a}ßinvasion oder Thrombusbildung. Ziel der Dissertationsarbeit ist es, den technischen und klinischen Erfolg der Sinus-XL ® Stentimplantation in die Vena cava inferior bei einer tumorbedingten unteren Einflussstauung zu untersuchen. Als technischer Erfolg wurde dabei die problemlose Stentimplantation mit anschließender Aufhebung der VCI-Stenose/Okklusion und Revaskularisation der VCI definiert. Bez{\"u}glich des klinischen Erfolges wurde der Frage nachgegangen, inwieweit die Stentimplantation die typischen Symptome einer unteren Einflussstauung ({\"O}deme der unteren Extremit{\"a}t, Aszites und Anasarka) lindern und bestenfalls eliminieren kann. In der vorliegenden Arbeit sind dazu retrospektiv die Daten von insgesamt 21 Patienten (11 Frauen, 10 M{\"a}nner) mit einem medianen Alter von 61 Jahren (19-92 Jahre), die zwischen Oktober 2010 und Januar 2021 aufgrund einer tumorbedingten unteren Einflussstauung mit einem Sinus-XL ® Stent endovaskul{\"a}r versorgt wurden, ausgewertet worden. Zur Quantifizierung der klinischen Symptomatik wurde f{\"u}r das jeweilige Symptom ein Scoring-System entwickelt bzw. modifiziert. Der technische Erfolg belief sich auf 100\% (21/21). Postinterventionell konnte zudem eine signifikante Reduktion des transstenotischen Druckgradienten (p = 0,008) und eine signifikante Aufweitung des Stenosendiameters (p < 0,001) erreicht werden. Die prim{\"a}re und prim{\"a}r-assistierte Stentoffenheit betrug 92,9 \% (13/14) und 100\% (14/14), die anatomische Stentoffenheit (< 50\% Restenose) belief sich auf 53,3 \% (8/15). Die Reinterventionsrate lag bei 4,8 \% (1/21). Schwerwiegende Komplikationen traten nicht auf. Der klinische Erfolg bez{\"u}glich der {\"O}deme der unteren Extremit{\"a}t belief sich auf 82,4 \% (14/17), 93,8 \% (15/16) sowie auf 85,7 \% (18/21) und zeigte in allen betrachteten Zeitintervallen eine signifikante Scorewertreduktion (p < 0,001). Das klinische Outcome bez{\"u}glich der {\"O}deme war bei k{\"u}rzeren Stenosen/Obstruktionen signifikant besser (p = 0,025). Bez{\"u}glich einer intrahepatischen Segmentbeteiligung, der transstenotischen Druckgradienten, der absoluten Gradientenreduktion sowie der {\"U}berlebenszeit nach der Intervention zeigten sich hingegen keine als klinisch relevant einzustufende Ergebnisse. Ein eindeutiger Effekt der Intervention auf die Symptome Anasarka und Aszites konnte nicht nachgewiesen werden. Diesbez{\"u}glich zeigten sich klinische Erfolgsraten von 42,9 \% (6/14) und 5,3 \% (1/19). Im postinterventionellen Verlauf konnten außerdem signifikante Reduktionen der pr{\"a}interventionellen Harnstoffwerte sowie des K{\"o}rpergewichtes der Patienten verzeichnet werden. Zusammenfassend zeigt die vorliegende Arbeit, dass die Sinus-XL ® Stentimplantation geeignet ist, eine tumorbedingte Vena cava inferior-Stenose/Obstruktion aufzuheben und eine Revaskularisation der VCI zu erreichen. Die klinischen Symptome einer unteren Einflussstauung - insbesondere bezogen auf die {\"O}deme der unteren Extremit{\"a}t und mit Einschr{\"a}nkungen bezogen auf die Symptome Aszites und Anasarka - k{\"o}nnen ebenfalls durch die Stentimplantation gelindert und teilweise sogar langanhaltend eliminiert werden. Die Sinus-XL ® Stentimplantation sollte daher stets als Therapieoption bei tumorbedingten unteren Einflussstauungen in Erw{\"a}gung gezogen werden. Nicht zuletzt stellt die Stentimplantation auch eine sichere und komplikationsarme Intervention dar. Weitere Studien, bestenfalls multizentrische Studien, sind jedoch notwendig, um die dargestellten Ergebnisse weiter zu untermauern.}, subject = {Vena cava inferior}, language = {de} } @phdthesis{Steingrueber2023, author = {Steingr{\"u}ber, Marcus}, title = {Die perkutane transluminale Zangenbiopsie bili{\"a}rer Strikturen: Eine neuartige Methode}, doi = {10.25972/OPUS-32172}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-321721}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2023}, abstract = {Das Ziel der Studie bestand darin, die Durchf{\"u}hrbarkeit, Effizienz und Sicherheit der perkutanen transluminalen Zangenbiopsie bei bili{\"a}ren Strikturen nach „Cross and push" Technik am Universit{\"a}tsklinikum W{\"u}rzburg zu evaluieren. Die Gewinnung der Zangenbiopsie bei den insgesamt 17 Patienten erfolgte an den baugleichen Angiographieeinheiten der interventionellen radiologischen Abteilung. Die Schaffung des bili{\"a}ren Zugangsweges wurde per Feinnadelpunktion oder {\"u}ber einen bereits einliegenden Drainagekatheter durchgef{\"u}hrt. Nach Vordirigieren einer armierten F{\"u}hrungsschleuse bis unmittelbar vor die Stenose wurden die Gewebeproben mittels Biopsiezange entnommen. Auf diese Weise sollte ein Abknicken des Instrumentariums durch die fibrotische Beschaffenheit der Striktur vermieden und so die Gewebegewinnung erleichtert werden. Im Anschluss folgten die PTCD-Neuanlage bzw. der Katheterwechsel sowie die histologische Auswertung der Zangenbiopsie. Die Dokumentation umfasste den technischen Erfolg, die Biopsieanzahl sowie -gr{\"o}ße, die Untersuchungs- und die Fluoroskopiezeit, das Dosisfl{\"a}chenprodukt, die Repr{\"a}sentativit{\"a}t der Biopsien und die Komplikationsrate. Die technische Erfolgsrate lag bei 100 \%. Bei zehn Patienten und Patientinnen (58,8 \%) wurde in der Zangenbiopsie ein Malignom best{\"a}tigt. Bei sieben Betroffenen (41,2 \%) ergab die Zangenbiopsie einen benignen Befund, wobei dieser in zwei F{\"a}llen (11,8 \%) falsch negativ war. Die Kriterien der Repr{\"a}sentativit{\"a}t wurden bei elf Patienten und Patientinnen (64,7 \%) erf{\"u}llt. Die mediane Biopsiezahl betrug 4 und die Biopsiegr{\"o}ße war 1 - 2 mm. Bei einer medianen Untersuchungszeit von 24 min bemaß sich die mediane Fluoroskopiezeit auf 7,6 min. Das mediane DAP f{\"u}r alle Interventionen betrug 2.593 μGym2. Zu einer Majorkomplikation kam es bei einer Patientin (5,9 \%). Bei der perkutanen transluminalen Zangenbiopsie nach „Cross and push" Technik handelt es sich um ein effektives und sicheres Verfahren zur histologischen Beurteilung bili{\"a}rer Strikturen mit einer moderaten Komplikationsrate. Die Anwendung sollte besonders bei proximalen Strikturen in Betracht gezogen werden, wenn die ERCP oder alternative Verfahren nicht erfolgreich waren und parallel eine Entlastung der Cholestase via PTCD intendiert oder bereits vorhanden ist. Zur weiteren Evaluation der Methode ist zuk{\"u}nftig die Betrachtung eines gr{\"o}ßeren Patientenkollektives n{\"o}tig. Um das Verfahren mit Alternativmethoden vergleichen zu k{\"o}nnen, bedarf es randomisierter kontrollierter Studien.}, language = {de} }