@article{WimmerRandauDemletal.2013, author = {Wimmer, Matthias D. and Randau, Thomas M. and Deml, Moritz C. and Ascherl, Rudolf and Forst, Raimund and Gravius, Nadine and Wirtz, Dieter and Gravius, Sascha}, title = {Impaction grafting in the femur in cementless modular revision total hip arthroplasty: a descriptive outcome analysis of 243 cases with the MRP-TITAN revision implant}, series = {BMC Musculoskeletal Disorders}, volume = {14}, journal = {BMC Musculoskeletal Disorders}, number = {19}, issn = {1471-2474}, doi = {10.1186/1471-2474-14-19}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-122061}, year = {2013}, abstract = {Background: We present a descriptive and retrospective analysis of revision total hip arthroplasties (THA) using the MRP-TITAN stem (Peter Brehm, Weisendorf, GER) with distal diaphyseal fixation and metaphyseal defect augmentation. Our hypothesis was that the metaphyseal defect augmentation (Impaction Bone Grafting) improves the stem survival. Methods: We retrospectively analyzed the aggregated and anonymized data of 243 femoral stem revisions. 68 patients with 70 implants (28.8\%) received an allograft augmentation for metaphyseal defects; 165 patients with 173 implants (71.2\%) did not, and served as controls. The mean follow-up was 4.4 +/- 1.8 years (range, 2.1-9.6 years). There were no significant differences (p > 0.05) between the study and control group regarding age, body mass index (BMI), femoral defects (types I-III as described by Paprosky), and preoperative Harris Hip Score (HHS). Postoperative clinical function was evaluated using the HHS. Postoperative radiologic examination evaluated implant stability, axial implant migration, signs of implant loosening, periprosthetic radiolucencies, as well as bone regeneration and resorption. Results: There were comparable rates of intraoperative and postoperative complications in the study and control groups (p > 0.05). Clinical function, expressed as the increase in the postoperative HHS over the preoperative score, showed significantly greater improvement in the group with Impaction Bone Grafting (35.6 +/- 14.3 vs. 30.8 +/- 15.8; p <= 0.05). The study group showed better outcome especially for larger defects (types II C and III as described by Paprosky) and stem diameters >= 17 mm. The two groups did not show significant differences in the rate of aseptic loosening (1.4\% vs. 2.9\%) and the rate of revisions (8.6\% vs. 11\%). The Kaplan-Meier survival for the MRP-TITAN stem in both groups together was 93.8\% after 8.8 years. [Study group 95.7\% after 8.54 years; control group 93.1\% after 8.7 years]. Radiologic evaluation showed no significant change in axial implant migration (4.3\% vs. 9.3\%; p = 0.19) but a significant reduction in proximal stress shielding (5.7\% vs. 17.9\%; p < 0.05) in the study group. Periprosthetic radiolucencies were detected in 5.7\% of the study group and in 9.8\% of the control group (p = 0.30). Radiolucencies in the proximal zones 1 and 7 according to Gruen occurred significantly more often in the control group without allograft augmentation (p = 0.05). Conclusion: We present the largest analysis of the impaction grafting technique in combination with cementless distal diaphyseal stem fixation published so far. Our data provides initial evidence of improved bone regeneration after graft augmentation of metaphyseal bone defects. The data suggests that proximal metaphyseal graft augmentation is beneficial for large metaphyseal bone defects (Paprosky types IIC and III) and stem diameters of 17 mm and above. Due to the limitations of a retrospective and descriptive study the level of evidence remains low and prospective trials should be conducted.}, language = {en} } @article{WirtzGraviusAscherletal.2014, author = {Wirtz, Dieter C. and Gravius, Sascha and Ascherl, Rudolf and Thorweihe, Miguel and Forst, Raimund and Noeth, Ulrich and Maus, Uwe M. and Wimmer, Matthias D. and Zeiler, Guenther and Deml, Moritz C.}, title = {Uncemented femoral revision arthroplasty using a modular tapered, fluted titanium stem 5-to 16-year results of 163 cases}, series = {Acta Orthopaedica}, volume = {85}, journal = {Acta Orthopaedica}, number = {6}, issn = {1745-3674}, doi = {10.3109/17453674.2014.958809}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-114555}, pages = {562 - 569}, year = {2014}, abstract = {Background and purpose - Due to the relative lack of reports on the medium- to long-term clinical and radiographic results of modular femoral cementless revision, we conducted this study to evaluate the medium- to long-term results of uncemented femoral stem revisions using the modular MRP-TITAN stem with distal diaphyseal fixation in a consecutive patient series. Patients and methods - We retrospectively analyzed 163 femoral stem revisions performed between 1993 and 2001 with a mean follow-up of 10 (5-16) years. Clinical assessment included the Harris hip score (HHS) with reference to comorbidities and femoral defect sizes classified by Charnley and Paprosky. Intraoperative and postoperative complications were analyzed and the failure rate of the MRP stem for any reason was examined. Results - Mean HHS improved up to the last follow-up (37 (SD 24) vs. 79 (SD 19); p < 0.001). 99 cases (61\%) had extensive bone defects (Paprosky IIB-III). Radiographic evaluation showed stable stem anchorage in 151 cases (93\%) at the last follow-up. 10 implants (6\%) failed for various reasons. Neither a breakage of a stem nor loosening of the morse taper junction was recorded. Kaplan-Meier survival analysis revealed a 10-year survival probability of 97\% (95\% CI: 95-100). Interpretation - This is one of the largest medium- to longterm analyses of cementless modular revision stems with distal diaphyseal anchorage. The modular MRP-TITAN was reliable, with a Kaplan-Meier survival probability of 97\% at 10 years.}, language = {en} } @phdthesis{Haacke2009, author = {Haacke, Christian}, title = {Die multifunktionelle Gef{\"a}ßprothese - Weiterentwicklung und Optimierung}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-36584}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2009}, abstract = {Einleitung M{\"u}ssen im Verlauf einer kardiovaskul{\"a}ren Erkrankung gesch{\"a}digte Gef{\"a}ßabschnitte ersetzt werden, stehen den Gef{\"a}ßchirurgen neben organischen Eigen- oder Fremdmaterial haupts{\"a}chlich die Kunststoffe Polytetraflourethylen (PTFE) und Polyethylen-terephtalat (PET, Polyester, Dacron®) zum Gef{\"a}ßersatz zur Verf{\"u}gung. Im Zusammenhang mit diesen k{\"u}nstlichen Ersatzmaterialien kommt es allerdings h{\"a}ufig zu Komplikationen. Diese sind besonders nach Rekonstruktion kleiner Gef{\"a}ße durch die Thrombogenit{\"a}t ihrer Oberfl{\"a}chen und eine {\"u}bersteigerte Intimahyperplasie bedingt. Urs{\"a}chlich f{\"u}r einen Misserfolg k{\"o}nnen außerdem eine ungen{\"u}gende Dichtigkeit und eine Infektion des Gef{\"a}ßersatzes sein. Diese Arbeit besch{\"a}ftigt sich mit der Weiterentwicklung einer "multifunktionellen" Silikon-beschichteten und Medikamenten-freisetzenden Gef{\"a}ßprothese, bei der die Oberfl{\"a}cheneigenschaften optimiert wurden. Material und Methoden Herstellung der Prothesen: Gewirkte Polyesterprothesen wurden maschinell mit Silikon beschichtet. Mit Hilfe einer neuen Beschichtungsmaschine wurden die Prothesen zus{\"a}tzlich von innen mit Silikon betropft. Durch einen nass-chemischen Prozess wurden in einem zweiten Schritt verschiedene Stoffe kovalent an die Oberfl{\"a}che des Silikons gebunden (Polyvinylpyrrolidon, Polyvinylalkohol, Phosphorylcholin, eine amphotere Oberfl{\"a}che, Silber und die Kombination von Silber und PVA). Außerdem wurde das Medikament Paclitaxel (Taxol®) in die Silikonmatrix eingebracht. Untersuchung der Eigenschaften: Es wurde die Dichtigkeit nach Beschichtung und zus{\"a}tzlich der Wasserverlust nach Einstich mit Kan{\"u}len und Venenverweilkan{\"u}len untersucht und mit dem herk{\"o}mmlicher Prothesen verglichen (eine PTFE -, eine mit Kollagen beschichtete und eine 3-schichtige PTFE-Polymer - Prothese (Rapidax)). Zus{\"a}tzlich wurden die antiinfekti{\"o}sen Eigenschaften der verschiedenen Oberfl{\"a}chen (Silber, amphotere Oberfl{\"a}che, Kollagen- und Silikon-beschichtete Polyesterprothesen) auf den Prothesen, der Einfluss der an die Prothese gebundenen Molek{\"u}le auf die Thrombogenit{\"a}t und die Elution von Paclitaxel, einem Medikament zur Unterdr{\"u}ckung der Intimahyperplasie, untersucht. Ergebnisse Herstellung der Prothesen. Die Umstellung des Beschichtungsvorgangs mit einer 3. Beschichtung von innen konnte realisiert werden. Untersuchung der Eigenschaften: Dichtigkeit: Bei der Untersuchung des Wasserverlustss nach Einstich von Kan{\"u}len und Venenverweilkan{\"u}len zeigten sich die geringsten Verlustraten bei der Rapidax®-Prothese und die h{\"o}chsten bei der PTFE-Prothese. Die Silikon-beschichtete und die herk{\"o}mmliche PET-Prothese erzielten insgesamt {\"a}hnliche Ergebnisse Oberfl{\"a}chenthrombogenit{\"a}t: Durch die Beschichtung mit Silikon konnte im Vergleich zur reinen Polyesterprothese und gegen{\"u}ber den herk{\"o}mmlichen Prothesen (Dacron®-Gelatine und PTFE) in allen Versuchen eine geringere Gerinnungsaktivierung f{\"u}r die Silikonprothese festgestellt werden. Die zus{\"a}tzliche Oberfl{\"a}chenmodifizierung von Silikon- und Silberprothesen mit PVA erbrachte niedrigere Gerinnungswerte als die alleinigen Oberfl{\"a}chen. Die antiinfekti{\"o}se Oberfl{\"a}che: Die mit Silber modifizierte Silikon-beschichtete Prothese konnte das bakterielle Wachstum komplett inhibieren. Die amphotere Oberfl{\"a}che hingegen konnte das bakterielle Wachstum im Vergleich zur reinen Silikonoberfl{\"a}che nur leicht hemmen. Medikamentenelution: Paclitaxel konnte im Kreislaufmodell und auch im statischen Versuchsaufbau {\"u}ber einen Zeitraum von bis zu 21 Tagen im Humanalbumin nachgewiesen werden. Diskussion Durch die Beschichtung mit Silikon wird eine prim{\"a}re Dichtigkeit erreicht. Außerdem konnten nun die Prothesen durch die Umstellung des Herstellungsverfahrens in besserer Qualit{\"a}t und schneller hergestellt werden. Es konnte nachgewiesen werden, dass die Eigenschaften der einzelnen Molek{\"u}le in der Kombinationsprothese erhalten bleiben: so konnte die Thrombogenit{\"a}t der antiinfekti{\"o}sen Silberprothese durch das PVA aufgehoben werden. Die Elution des Paclitaxels war unabh{\"a}ngig von der Oberfl{\"a}chenbeschichtung. Alternativ k{\"o}nnen auch andere Molek{\"u}le und Medikamente verwendet werden. Ziel ist nun die Testung dieser Prothese zun{\"a}chst im Tierversuch und auf lange Sicht in einer klinischen Studie. Insbesondere bietet sich eine vergleichende Studie mit herk{\"o}mmlichen Prothesen im Dialyseeinsatz an, da die Silikonprothese hinsichtlich der Dichtigkeit besonders bei Venenverweilkan{\"u}len mittleren Durchmessers gegen{\"u}ber PTFE- und einer Polyester-Prothese {\"u}berzeugen konnte.}, subject = {Silicone}, language = {de} }