@article{BliziotisKluijtmansTinneveltetal.2022, author = {Bliziotis, Nikolaos G. and Kluijtmans, Leo A. J. and Tinnevelt, Gerjen H. and Reel, Parminder and Reel, Smarti and Langton, Katharina and Robledo, Mercedes and Pamporaki, Christina and Pecori, Alessio and Van Kralingen, Josie and Tetti, Martina and Engelke, Udo F. H. and Erlic, Zoran and Engel, Jasper and Deutschbein, Timo and N{\"o}lting, Svenja and Prejbisz, Aleksander and Richter, Susan and Adamski, Jerzy and Januszewicz, Andrzej and Ceccato, Filippo and Scaroni, Carla and Dennedy, Michael C. and Williams, Tracy A. and Lenzini, Livia and Gimenez-Roqueplo, Anne-Paule and Davies, Eleanor and Fassnacht, Martin and Remde, Hanna and Eisenhofer, Graeme and Beuschlein, Felix and Kroiss, Matthias and Jefferson, Emily and Zennaro, Maria-Christina and Wevers, Ron A. and Jansen, Jeroen J. and Deinum, Jaap and Timmers, Henri J. L. M.}, title = {Preanalytical pitfalls in untargeted plasma nuclear magnetic resonance metabolomics of endocrine hypertension}, series = {Metabolites}, volume = {12}, journal = {Metabolites}, number = {8}, issn = {2218-1989}, doi = {10.3390/metabo12080679}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-282930}, year = {2022}, abstract = {Despite considerable morbidity and mortality, numerous cases of endocrine hypertension (EHT) forms, including primary aldosteronism (PA), pheochromocytoma and functional paraganglioma (PPGL), and Cushing's syndrome (CS), remain undetected. We aimed to establish signatures for the different forms of EHT, investigate potentially confounding effects and establish unbiased disease biomarkers. Plasma samples were obtained from 13 biobanks across seven countries and analyzed using untargeted NMR metabolomics. We compared unstratified samples of 106 PHT patients to 231 EHT patients, including 104 PA, 94 PPGL and 33 CS patients. Spectra were subjected to a multivariate statistical comparison of PHT to EHT forms and the associated signatures were obtained. Three approaches were applied to investigate and correct confounding effects. Though we found signatures that could separate PHT from EHT forms, there were also key similarities with the signatures of sample center of origin and sample age. The study design restricted the applicability of the corrections employed. With the samples that were available, no biomarkers for PHT vs. EHT could be identified. The complexity of the confounding effects, evidenced by their robustness to correction approaches, highlighted the need for a consensus on how to deal with variabilities probably attributed to preanalytical factors in retrospective, multicenter metabolomics studies.}, language = {en} } @article{SherifHeroldVoelkeretal.2015, author = {Sherif, Mohammad A. and Herold, Joerg and Voelker, Wolfram and Maniuc, Octavian and Ertl, Georg and Praast, Christian and Braun-Dullaeus, Ruediger Christian}, title = {Feasibility of a new method using two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation; a case-control study}, series = {BMC Cardiovascular Disorders}, volume = {15}, journal = {BMC Cardiovascular Disorders}, number = {78}, doi = {10.1186/s12872-015-0072-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-148328}, year = {2015}, abstract = {Background: Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we validated a new method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus prior to TAVI. Methods: We analysed 124 patients who underwent successful TAVI using a self-expandable prosthesis, divided equally into two groups; in the study group we used the cross sectional short axis 2D-TEE for measurement of the aortic annulus and in the control group we used the long axis 2D-TEE. Results: Both groups were comparable regarding the clinical parameters. On the other hand, patients in the study group had less left ventricular ejection fraction (38.9 \% versus 45.6 \%, p = 0.01). The aortic valve annulus was, although not statistically significant, smaller in the study group (21.58 versus 23.28 mm, p = 0.25). Post procedural quantification of the aortic regurgitation revealed that only one patient in both groups had severe aortic regurgitation (AR), in this patient the valve was implanted deep. The incidence of significant AR was higher in the control group (29.0 \% versus 12.9 \%, p = 0.027). Conclusions: Sizing of the aortic valve annulus using cross-sectional 2D-TEE offers a safe and plausible method for patients undergoing TAVI using the self-expandable prosthesis and is significantly superior to using long axis 2D-TEE.}, language = {en} } @article{SherifInceManiucetal.2015, author = {Sherif, Mohammad A. and Ince, H{\"u}seyin and Maniuc, Octavian and Reiter, Therese and Voelker, Wolfram and Ertl, Georg and {\"O}ner, Alper}, title = {Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation}, series = {BMC Cardiovascular Disorders}, volume = {15}, journal = {BMC Cardiovascular Disorders}, number = {181}, doi = {10.1186/s12872-015-0181-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-136002}, year = {2015}, abstract = {Background: Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we examined the accuracy of a novel method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus. Methods: We evaluated the theoretical impact of the measurement of the annulus diameter and area using the circumcircle of a triangle method on the decision to perform the procedure and choice of the prosthesis size. Results: Sixty-three consecutive patients were scheduled for TAVI. Mean age was 82 +/- 4 years, and 25 patients (55.6 \%) were female. Mean aortic annulus diameter was 20.3 +/- 2.2 mm assessed by TEE on the mid-esophageal long-axis view and 23.9 +/- 2.3 mm using CT (p < 0.001). There was a tendency for the TEE derived areas using the new method to be higher (p < 0.001). The TEE measurements were on average 42.33 mm(2) higher than the CT measurements without an evidence of a systematic over-or under-sizing (p = 1.00). Agreement between TEE and CT chosen valve sizes was good overall (kappa = 0.67 and weighted kappa = 0.71). For patients who turned out to have no AR, the two methods agreed in 84.6 \% of patients. Conclusions: CT remanis the gold standard in sizing of the aortic valve annulus. Nevertheless, sizing of the aortic valve annulus using TEE derived area may be helpful. The impact of integration of this method in the algorithm of aortic annulus sizing on the outcome of patients undergoing TAVI should be examined in future studies.}, language = {en} }