@article{LeistnerHolzgrabe2021, author = {Leistner, Adrian and Holzgrabe, Ulrike}, title = {Impurity Profiling of Baclofen Using Gradient HPLC-UV Method}, series = {Chromatographia}, volume = {84}, journal = {Chromatographia}, number = {10}, issn = {1612-1112}, doi = {10.1007/s10337-021-04079-y}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-268921}, pages = {927-935}, year = {2021}, abstract = {The GABA\(_{B}\) receptor agonist baclofen is a medication commonly used for the treatment of muscle spasticity. It is an amino acid and related to the neurotransmitter GABA. In this study, we developed a new, gradient high-performance liquid chromatography (HPLC) method for the impurity assessment of baclofen, which is appropriate for pharmacopoeial purposes. Since the impurities related to the synthesis pathway are acids, zwitterionic, or neutral, the method development is challenging. However, the separation of all components was achieved on a C18 stationary phase using a water-acetonitrile-trifluoroacetic acid gradient. A limit of detection (LOD) of at least 0.02\% was registered for all specified impurities. Additionally, CAD detection was performed to detect potential impurities lacking off a chromophore. The baclofen batches analyzed are far more pure than expected. All impurities were found below the specification limit, and thus, they can be regarded as unspecified. Moreover, the required runtime could be significantly reduced compared to the current USP or Ph. Eur. method.}, language = {en} } @phdthesis{Ilko2015, author = {Ilko, David}, title = {The use of charged aerosol detection for the analysis of excipients and active pharmaceutical ingredients}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-118377}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {The Corona® charged aerosol detector (CAD) is an aerosol-based detector first de-scribed by Dixon and Peterson in 2002. It is capable of detecting compounds inde-pendent from their physico-chemical properties presumed the analyte is sufficiently non-volatile. Consequently, the CAD is often applied to the analysis of substances that do not possess a suitable UV chromophore. Major drawbacks are however, the detector signal is non-linear and depending on the content of organic solvent in the mobile phase. This thesis tried to explore possible applications of the CAD for pharmaceutical analysis. Therefore, several substances from different compound classes were in-vestigated. Newly developed or existing methods were validated. Thus the perfor-mance of the CAD could be examined. Both assay and impurity determination were evaluated for their compliance with ICH Q2(R1) "Validation of Analytical Proce-dures" and the "Technical Guide for the Elaboration of Monographs". In the course of the establishment of reference substances at the EDQM, a generic screening method for the identification of organic and inorganic pharmaceutical counterions was needed. An HPLC-CAD method developed by Zhang et al. was therefore investigated for its suitability for pharmacopoeial purpose. Method valida-tion was performed. It was found that 23 ions could be separated and detected. Iden-tification was achieved via retention time of an authentic standard of the corre-sponding ions. Alternatively, peak assignment was performed by determination of the exact mass using TOF-MS. Ions could be quantified as impurities or for stoichi-ometric purpose. For the impurity control in topiramate, the performance characterstics of the CAD were compared to that of an ELSD. CAD was superior to ELSD in terms of repeata-bility, sensitivity and linearity. However, impurities could be quantified with satisfac-tory accuracy with both detectors. The application of the ELSD was not feasible due to non-reproducible spike peaks eluting after the principle peak in the chromatogram of the test solution. One of the impurities, topiramate impurity A (diacetonide), gave no or a vastly diminished signal in the ELSD and the CAD, respectively. It is evapo-rated during the detection process due to its relatively high vapor pressure. The re-sponse could be enhanced by a factor of nine via post-column addition of acetoni-trile and a lower nebulizer temperature. As the response of topiramate impurity A was still about thousand-fold lower than the response of all other impurities, its quantification was not feasible. Additionally, the HPLC-CAD was successfully vali-dated as an assay procedure for topiramate. There seems to be a great potential in the application of the CAD to the analysis of excipients as most compounds do not possess a suitable UV chromophore. Here, a simple and rapid HPLC-CAD method for the determination of polidocanol (PD) was developed. The method was successfully validated as a potential assay procedure for the Ph. Eur. as none is described in either of the two PD monographs. The same method was applied to the determination of the PD release from a pharmaceutical polymer matrix. A method for the determination of the fatty acid (FA) composition of polysorbate 80 (PS80) was developed and validated. Using the CAD and mass spectrometry, we were able to identify two new FAs in 16 batches from four manufacturers. All batch-es complied with pharmacopoeial specification. Furthermore, the overall composi-tion of the different PS80 species ("fingerprinting") and the peroxide content were determined. In addition to the chemical characterization, functionality related charac-teristics (FRCs) were determined. Correlations between chemical composition and FRCs were found. The validation data of the above mentioned methods suggests that the CAD repre-sents a viable detection technique for pharmaceutical analysis. The CAD was suffi-ciently sensitive for non-volatile analytes. Impurity control down to concentrations of 0.05 or 0.03\%, as demanded by ICH Q3A (R2), is achievable. However, the response of semi-volatile compounds may be drastically diminished. It could be confirmed that the response of the CAD is linear when the range does not exceed two orders of magnitude. Exceptions may be observed depending on the actual method setup. When the measuring range is sufficiently narrow, quantification can be done using single-point calibration which is common practice in pharmaceutical anlysis. Impuri-ties may also be quantified against a single calibration solution. However, correction factors may be needed and the accuracy is considerably lower compared to an as-say method. If a compound is to be quantified over a large concentration range, log-log transformation of the calibration curve is needed and a decreased accuracy has to be accepted.}, subject = {Analyse}, language = {en} }