@article{AugustinWolfschmidtElsaesseretal.2022, author = {Augustin, Anne Marie and Wolfschmidt, Franziska and Els{\"a}sser, Thilo and Sauer, Alexander and Dierks, Alexander and Bley, Thorsten Alexander and Kickuth, Ralph}, title = {Color-coded summation images for the evaluation of blood flow in endovascular aortic dissection fenestration}, series = {BMC Medical Imaging}, volume = {22}, journal = {BMC Medical Imaging}, number = {1}, doi = {10.1186/s12880-022-00744-2}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-301107}, year = {2022}, abstract = {Background To analyze the benefit of color-coded summation images in the assessment of target lumen perfusion in patients with aortic dissection and malperfusion syndrome before and after fluoroscopy-guided aortic fenestration. Methods Between December 2011 and April 2020 25 patients with Stanford type A (n = 13) or type B dissection (n = 12) and malperfusion syndromes were treated with fluoroscopy-guided fenestration of the dissection flap using a re-entry catheter. The procedure was technically successful in 100\% of the cases and included additional iliofemoral stent implantation in four patients. Intraprocedural systolic blood pressure measurements for gradient evaluation were performed in 19 cases. Post-processed color-coded DSA images were obtained from all DSA series before and following fenestration. Differences in time to peak (dTTP) values in the compromised aortic lumen and transluminal systolic blood pressure gradients were analyzed retrospectively. Correlation analysis between dTTP and changes in blood pressure gradients was performed. Results Mean TTP prior to dissection flap fenestration was 6.85 ± 1.35 s. After fenestration, mean TTP decreased significantly to 4.96 ± 0.94 s (p < 0.001). Available systolic blood pressure gradients between the true and the false lumen were reduced by a median of 4.0 mmHg following fenestration (p = 0.031), with significant reductions in Stanford type B dissections (p = 0.013) and minor reductions in type A dissections (p = 0.530). A moderate correlation with no statistical significance was found between dTTP and the difference in systolic blood pressure (r = 0.226; p = 0.351). Conclusions Hemodynamic parameters obtained from color-coded DSA confirmed a significant reduction of TTP values in the aortic target lumen in terms of an improved perfusion in the compromised aortic region. Color-coded DSA might thus be a suitable complementary tool in the assessment of complex vascular patterns prevailing in aortic dissections, especially when blood pressure measurements are not conclusive or feasible.}, language = {en} } @article{AugustinWelschBleyetal.2021, author = {Augustin, Anne Marie and Welsch, Stefan and Bley, Thorsten Alexander and Lopau, Kai and Kickuth, Ralph}, title = {Color-coded summation images in the evaluation of renal artery stenosis before and after percutaneous transluminal angioplasty}, series = {BMC Medical Imaging}, volume = {21}, journal = {BMC Medical Imaging}, number = {1}, doi = {10.1186/s12880-020-00540-w}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-259086}, pages = {21}, year = {2021}, abstract = {Background: Endovascular therapy is the gold standard in patients with hemodynamic relevant renal artery stenosis (RAS) resistant to medical therapy. The severity grading of the stenosis as well as the result assessment after endovascular approach is predominantly based on visible estimations of the anatomic appearance. We aim to investigate the application of color-coded DSA parameters to gain hemodynamic information during endovascular renal artery interventions and for the assessment of the procedures technical success. Methods: We retrospectively evaluated 32 patients who underwent endovascular renal artery revascularization and applied color-coded summation imaging on selected monochromatic DSA images. The differences in time to peak (dTTP) of contrast enhancement in predefined anatomical measuring points were analyzed. Furthermore, differences in systolic blood pressure values (SBP) and serum creatinine were obtained. The value of underlying diabetes mellitus as a predictor for clinical outcome was assessed. Correlation analysis between the patients gender as well as the presence of diabetes mellitus and dTTP was performed. Results: Endovascular revascularization resulted in statistically significant improvement in 4/7 regions of interest. Highly significant improvement of perfusion in terms of shortened TTP values could be found at the segmental artery level and in the intrastenotical segment (p<0.001), significant improvement prestenotical and in the apical renal parenchyma (p<0.05). In the other anatomic regions, differences revealed not to be significant. Differences between SBP and serum creatinine levels before and after the procedure were significant (p=0.004 and 0.0004). Patients ' gender as well as the presence of diabetes mellitus did not reveal to be predictors for the clinical success of the procedure. Furthermore, diabetes and gender did not show relevant correlation with dTTP in the parenchymal measuring points. Conclusions: The supplementary use of color-coding DSA and the data gained from parametric images may provide helpful information in the evaluation of the procedures ' technical success. The segmental artery might be a particularly suitable vascular territory for analyzing differences in blood flow characteristics. Further studies with larger cohorts are needed to further confirm the diagnostic value of this technique.}, language = {en} } @article{AugustinLuciusThurneretal.2022, author = {Augustin, Anne Marie and Lucius, Leonie Johanna and Thurner, Annette and Kickuth, Ralph}, title = {Malignant obstruction of the inferior vena cava: clinical experience with the self-expanding Sinus-XL stent system}, series = {Abdominal Radiology}, volume = {47}, journal = {Abdominal Radiology}, number = {10}, doi = {10.1007/s00261-022-03587-1}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324951}, pages = {3604-3614}, year = {2022}, abstract = {Purpose To evaluate the technical and clinical outcome of Sinus-XL stent placement in patients with malignant obstruction syndrome of the inferior vena cava. Methods Between October 2010 and January 2021, 21 patients with different malignant primary disease causing inferior vena cava obstruction were treated with Sinus-XL stent implantation. Procedural data, technical and clinical outcome parameters were retrospectively analyzed. Results Technical success was 100\%. Analysis of available manometry data revealed a significant reduction of the mean translesional pressure gradient following the procedure (p = 0.008). Reintervention rate was 4.8\% (1/21). The available follow-up imaging studies showed primary and primary-assisted stent patency rates of 93\% (13/14) and 100\% (14/14), respectively. Major complications did not occur. The clinical success regarding lower extremity edema was 82.4\% (14/17) for the first and 85.7\% (18/21) for the last follow-up. Longer lengths of IVC obstruction were associated with reduced clinical improvement after the procedure (p = 0.025). Improvement of intraprocedural manometry results and lower extremity edema revealed only minor correlation. Ascites and anasarca were not significantly positively affected by the procedure. Conclusion Sinus-XL stent placement in patients with malignant inferior vena cava obstruction showed high technical success and low complication rates. Regarding the clinical outcome, significant symptom improvement could be achieved in lower extremity edema, whereas ascites and anasarca lacked satisfying symptom relief. Based on our results, this procedure should be considered as a suitable therapy in a palliative care setting for patients with advanced malignant disease.}, language = {en} }