@inproceedings{WernerChenLapaetal.2017, author = {Werner, Rudolf and Chen, Xinyu and Lapa, Constantin and Robinson, Simon and Higuchi, Takahiro}, title = {Intracellular behavior of the novel sympathetic nerve agent \(^{18}\)F-LMI1195}, series = {Journal of Nuclear Cardiology}, volume = {24}, booktitle = {Journal of Nuclear Cardiology}, number = {4 Supplement (2017) Aug}, issn = {1071-3581}, doi = {10.1007/s12350-017-0984-y}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-161137}, pages = {1461-1496}, year = {2017}, abstract = {No abstract available.}, subject = {Herz}, language = {en} } @unpublished{WernerBundschuhBundschuhetal.2018, author = {Werner, Rudolf A. and Bundschuh, Ralph A. and Bundschuh, Lena and Javadi, Mehrbod S. and Leal, Jeffrey P. and Higuchi, Takahiro and Pienta, Kenneth J. and Buck, Andreas K. and Pomper, Martin G. and Gorin, Michael A. and Lapa, Constantin and Rowe, Steven P.}, title = {Interobserver Agreement for the Standardized Reporting System PSMA-RADS 1.0 on \(^{18}\)F-DCFPyL PET/CT Imaging}, series = {Journal of Nuclear Medicine}, journal = {Journal of Nuclear Medicine}, issn = {0161-5505}, doi = {10.2967/jnumed.118.217588}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-167788}, year = {2018}, abstract = {Objectives: Recently, the standardized reporting and data system for prostate-specific membrane antigen (PSMA)-targeted positron emission tomography (PET) imaging studies, termed PSMA-RADS version 1.0, was introduced. We aimed to determine the interobserver agreement for applying PSMA-RADS to imaging interpretation of 18F-DCFPyL PET examinations in a prospective setting mimicking the typical clinical work-flow at a prostate cancer referral center. Methods: Four readers (two experienced readers (ER, > 3 years of PSMA-targeted PET interpretation experience) and two inexperienced readers (IR, < 1 year of experience)), who had all read the initial publication on PSMA-RADS 1.0, assessed 50 18F-DCFPyL PET/computed tomography (CT) studies independently. Per scan, a maximum of 5 target lesions were selected by the observers and a PSMA-RADS score for every target lesion was recorded. No specific pre-existing conditions were placed on the selection of the target lesions, although PSMA-RADS 1.0 suggests that readers focus on the most highly avid or largest lesions. An overall scan impression based on PSMA-RADS was indicated and interobserver agreement rates on a target lesion-based, on an organ-based, and on an overall PSMA-RADS score-based level were computed. Results: The number of target lesions identified by each observer were as follows: ER 1, 123; ER 2, 134; IR 1, 123; and IR 2, 120. Among those selected target lesions, 125 were chosen by at least two individual observers (all four readers selected the same target lesion in 58/125 (46.4\%) instances, three readers in 40/125 (32\%) and two observers in 27/125 (21.6\%) instances). The interobserver agreement for PSMA-RADS scoring among identical target lesions was good (intraclass correlation coefficient (ICC) for four, three and two identical target lesions, ≥0.60, respectively). For lymph nodes, an excellent interobserver agreement was derived (ICC=0.79). The interobserver agreement for an overall scan impression based on PSMA-RADS was also excellent (ICC=0.84), with a significant difference for ER (ICC=0.97) vs. IR (ICC=0.74, P=0.005). Conclusions: PSMA-RADS demonstrates a high concordance rate in this study, even among readers with different levels of experience. This suggests that PSMA-RADS can be effectively used for communication with clinicians and can be implemented in the collection of data for large prospective trials.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{SerflingLapaDreheretal.2022, author = {Serfling, Sebastian E. and Lapa, Constantin and Dreher, Niklas and Hartrampf, Philipp E. and Rowe, Steven P. and Higuchi, Takahiro and Schirbel, Andreas and Weich, Alexander and Hahner, Stefanie and Fassnacht, Martin and Buck, Andreas K. and Werner, Rudolf A.}, title = {Impact of tumor burden on normal organ distribution in patients imaged with CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT}, series = {Molecular Imaging and Biology}, volume = {24}, journal = {Molecular Imaging and Biology}, number = {4}, doi = {10.1007/s11307-022-01717-1}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324622}, pages = {659-665}, year = {2022}, abstract = {Background CXCR4-directed positron emission tomography/computed tomography (PET/CT) has been used as a diagnostic tool in patients with solid tumors. We aimed to determine a potential correlation between tumor burden and radiotracer accumulation in normal organs. Methods Ninety patients with histologically proven solid cancers underwent CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT. Volumes of interest (VOIs) were placed in normal organs (heart, liver, spleen, bone marrow, and kidneys) and tumor lesions. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were determined. For CXCR4-positive tumor burden, maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA, defined as SUV\(_{mean}\) x TV), were calculated. We used a Spearman's rank correlation coefficient (ρ) to derive correlative indices between normal organ uptake and tumor burden. Results Median SUV\(_{mean}\) in unaffected organs was 5.2 for the spleen (range, 2.44 - 10.55), 3.27 for the kidneys (range, 1.52 - 17.4), followed by bone marrow (1.76, range, 0.84 - 3.98), heart (1.66, range, 0.88 - 2.89), and liver (1.28, range, 0.73 - 2.45). No significant correlation between SUV\(_{max}\) in tumor lesions (ρ ≤ 0.189, P ≥ 0.07), TV (ρ ≥ -0.204, P ≥ 0.06) or FTA (ρ ≥ -0.142, P ≥ 0.18) with the investigated organs was found. Conclusions In patients with solid tumors imaged with [\(^{68}\)Ga]Ga-PentixaFor PET/CT, no relevant tumor sink effect was noted. This observation may be of relevance for therapies with radioactive and non-radioactive CXCR4-directed drugs, as with increasing tumor burden, the dose to normal organs may remain unchanged.}, language = {en} } @article{IsraelRiehlButtetal.2023, author = {Israel, Ina and Riehl, Gabriele and Butt, Elke and Buck, Andreas K. and Samnick, Samuel}, title = {Gallium-68-labeled KISS1-54 peptide for mapping KISS1 receptor via PET: initial evaluation in human tumor cell lines and in tumor-bearing mice}, series = {Pharmaceuticals}, volume = {17}, journal = {Pharmaceuticals}, number = {1}, issn = {1424-8247}, doi = {10.3390/ph17010044}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-355898}, year = {2023}, abstract = {Kisspeptins (KPs, KISS1) and their receptor (KISS1R) play a pivotal role as metastasis suppressor for many cancers. Low or lost KP expression is associated with higher tumor grade, increased metastatic potential, and poor prognosis. Therefore, KP expression has prognostic relevance and correlates with invasiveness in cancers. Furthermore, KISS1R represents a very promising target for molecular imaging and therapy for KISS1R-expressing tumors. The goal of this study was to evaluate the developed KISS1-54 derivative, [\(^{68}\)Ga]KISS1-54, as a PET-imaging probe for KISS1R-expressing tumors. The NODAGA-KISS1-54 peptide was labeled by Gallium-68, and the stability of the resulting [\(^{68}\)Ga]KISS1-54 evaluated in injection solution and human serum, followed by an examination in different KISS1R-expressing tumor cell lines, including HepG2, HeLa, MDA-MB-231, MCF7, LNCap, SK-BR-3, and HCT116. Finally, [\(^{68}\)Ga]KISS1-54 was tested in LNCap- and MDA-MB-231-bearing mice, using µ-PET, assessing its potential as an imaging probe for PET. [\(^{68}\)Ga]KISS1-54 was obtained in a 77 ± 7\% radiochemical yield and at a >99\% purity. The [\(^{68}\)Ga]KISS1-54 cell uptake amounted to 0.6-4.4\% per 100,000 cells. Moreover, the accumulation of [\(^{68}\)Ga]KISS1-54 was effectively inhibited by nonradioactive KISS1-54. In [\(^{68}\)Ga]KISS1-54-PET, KISS1R-positive LNCap-tumors were clearly visualized as compared to MDA-MB-231-tumor implant with predominantly intracellular KISS1R expression. Our first results suggest that [\(^{68}\)Ga]KISS1-54 is a promising candidate for a radiotracer for targeting KISS1R-expressing tumors via PET.}, language = {en} } @article{WernerWakabyashiChenetal.2018, author = {Werner, Rudolf and Wakabyashi, Hiroshi and Chen, Xinyu and Hirano, Mitsuru and Shinaji, Tetsuya and Lapa, Constantin and Rowe, Steven and Javadi, Mehrbod and Higuchi, Takahiro}, title = {Functional renal imaging with \(^{18}\)F-FDS PET in rat models of renal disorders}, series = {Journal of Nuclear Medicine}, journal = {Journal of Nuclear Medicine}, issn = {0161-5505}, doi = {10.2967/jnumed.117.203828}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-161279}, year = {2018}, abstract = {Background: Precise regional quantitative assessment of renal function is limited with conventional \(^{99m}\)Tc-labeled renal radiotracers. A recent study reported that the positron emission tomography (PET) radiotracer 2-deoxy-2-(\(^{18}\)F-fluorosorbitol (\(^{18}\)F-FDS) has ideal pharmacokinetics for functional renal imaging. Furthermore, (\(^{18}\)F-FDS is available via simple reduction from routinely used 2-deoxy-2-(\(^{18}\)F-fluoro-D-glucose ((\(^{18}\)F-FDG). We aimed to further investigate the potential of (\(^{18}\)F-FDS PET as a functional renal imaging agent using rat models of kidney diseases. Methods: Two different rat models of renal impairment were investigated: Glycerol induced acute renal failure (ARF) by intramuscular administration of glycerol in hind legs and unilateral ureteral obstruction (UUO) by ligation of the left ureter. 24h after these treatments, dynamic 30 min 18F-FDS PET data were acquired using a dedicated small animal PET system. Urine 18F-FDS radioactivity 30 min after radiotracer injection was measured together with co-injected \(^{99m}\)Tc-diethylenetriaminepentaacetic acid (\(^{99m}\)Tc-DTPA) urine activity. Results: Dynamic PET imaging demonstrated rapid (\(^{18}\)F-FDS accumulation in the renal cortex and rapid radiotracer excretion via kidneys in control healthy rats. On the other hand, significantly delayed renal radiotracer uptake (continuous slow uptake) was observed in ARF rats and UUO-treated kidneys. Measured urine radiotracer concentrations of (\(^{18}\)F-FDS and \(^{99m}\)Tc-DTPA were well correlated (R=0.84, P<0.05). Conclusions: (\(^{18}\)F-FDS PET demonstrated favorable kinetics for functional renal imaging in rat models of kidney diseases. Advantages of high spatiotemporal resolution of PET imaging and simple tracer production could potentially complement or replace conventional renal scintigraphy in select cases and significantly improve the diagnostic performance of renal functional imaging.}, subject = {Nierenfunktionsst{\"o}rung}, language = {en} } @phdthesis{Schadt2022, author = {Schadt, Fabian}, title = {Entwicklung und erste Validierung eines innovativen Analysen-Tools f{\"u}r pr{\"a}klinische Bewertungen von PET-Radiopharmazeutika zur \(in\) \(vivo\) Untersuchungen neurologischer Erkrankungen}, doi = {10.25972/OPUS-24749}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-247499}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2022}, abstract = {Die pr{\"a}klinische Forschung stellt den ersten wichtigen Meilenstein in der Kl{\"a}rung und Untersuchung klinisch-relevanter Erkrankungen dar. Dar{\"u}ber hinaus unterst{\"u}tzt die pr{\"a}klinische Forschung erheblich die Entwicklung von Therapien. Die Kleintier-Positronenemissionstomographie (µ-PET) spielt dabei eine wichtige Rolle, da sie in der Lage ist, funktionelle, physiologische und biochemische Prozesse in vivo darzustellen und zu quantifizieren. Trotz diverser etablierter PET-Datenauswertungs-Programme bleibt die Analyse von in vivo akquirierten Bilddaten aufgrund der Vielzahl an medizinischen Fragestellungen, der Komplexit{\"a}t der Krankheitsbilder, sowie der Etablierung neuer Radiotracer weiterhin eine große Herausforderung in der Medizin. Ziel dieser Doktorarbeit ist es daher, ein geeignetes, brauchbares Auswertungstool f{\"u}r eine einfache und effiziente Analyse von akquirierten µ-PET-Daten zu entwickeln und zu etablieren, welches das Spektrum bereits vorhandener Programme erweitert. Das entwickelte nuklearmedizinische Datenverarbeitungs-Analyseprogramm (engl. nuclear medicine data processing analysis tool, NU_DPA) wurde in Matlab implementiert und anhand dreier pr{\"a}klinischer Versuchs- bzw. Testreihen erprobt und etabliert. Bei den Datenreihen handelt es sich um µ-PET-Datens{\"a}tze verschiedener Schlaganfall-Rattenhirnmodelle unter Verwendung folgender Radiotracer. Zum einen die im Gehirn homogen akkumulierende 2-[18F]Fluor-2-desoxy-glukose ([18F]FDG) zum anderen das spezifisch an P-Selektin anreichernde [68Ga]Fucoidan. Das NU_DPA umfasst die automatische Selektion des Zielvolumens (volume-of-interest, VOI) aus dem vollst{\"a}ndigen PET-Bild und die anschließende Ausrichtung des VOI mit Hilfe eines PET-Templates (gemittelter PET-Datensatz). Dieses PET Template wird aus den eigenen akquirierten PET-Daten erstellt. Durch das Einbinden eines geeigneten anatomischen MRT-Atlas' (anpassbar) k{\"o}nnen die ausgerichteten PET-Daten einzelnen, Atlas-spezifischen Teilregionen zugeordnet werden. Eine solche Subklassifikation des VOI erlaubt eine genauere Betrachtung und Auswertung der Radiotracer-Akkumulation. Des Weiteren bietet NU_DPA die M{\"o}glichkeit einer semiquantitativen Auswertung der PET-Bilddaten anhand von drei unterschiedlichen Parametern, der normalisierten Aktivit{\"a}t, dem Standardized Uptake Value und der Uptake Ratio. Durch die Matlab-integrierten Statistik-Algorithmen ist zus{\"a}tzlich eine M{\"o}glichkeit der statistischen Auswertung der zuvor berechneten Parameter gegeben. Das NU_DPA-Programm stellt somit ein semi-automatisiertes Datenauswertungs-Programm dar, das sowohl die Registrierung als auch die semiquantitative Auswertung von PET-Bilddaten innerhalb einer Versuchsreihe erm{\"o}glicht und bereits erfolgreich f{\"u}r die Radiotracer [18F]FDG und [68Ga]Fucoidan in Tiermodellen getestet wurde. Nach derzeitigem Kenntnisstand ist kein Datenauswertungs-Programm bekannt, das PET-Bilddaten unter Verwendung des hinzugef{\"u}gten Atlas' semi-automatisiert analysieren kann und potenziell f{\"u}r homogene und Target-spezifisch akkumulierende Radiotracer geeignet ist.}, subject = {PET}, language = {de} } @phdthesis{Becker2010, author = {Becker, Kilian}, title = {Entwicklung eines 3D-Ganzk{\"o}rper-Ultraschalls an Kleintieren f{\"u}r morphologische Bildgebung, Volumetrie und Bildfusion mit PET}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-55916}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2010}, abstract = {Einleitung: Ultraschall wird seit mehr als 50 Jahren in der Medizin eingesetzt und ist mittlerweile ein unverzichtbares diagnostisches Verfahren, es erlaubt eine nicht-invasive Darstellung der Morphologie und Funktion von Organen in Echtzeit. In der Kleintierbildgebung dominieren bisher zur morphologischen Bildgebung Computertomographie (CT) und Magnetresonanztomographie (MRT). Daher wurde in der vorliegenden Arbeit die Idee entwickelt, die morphologischen Informationen des 3D-Ultraschalls (3D-US) f{\"u}r Untersuchungen an Kleintieren zu verwenden, außerdem sollten Methoden zur multimodalen Bildgebung und Bildfusion von 3D-US und Kleintier-Positronenemissionstomographie (PET) entwickelt werden. Der Vorteil des Ultraschalls gegen{\"u}ber dem Kleintier-CT liegt in der fehlenden Strahlenbelastung und der guten Verf{\"u}gbarkeit, was besonders f{\"u}r Verlaufsstudien von Interesse ist. Methoden und Ergebnisse: Zur Bildoptimierung wurde ein Fadenphantom entwickelt, welches aufgrund der feinen Strukturen die qualitative als auch quantitative Bestimmung der Aufl{\"o}sung erm{\"o}glicht. Die Vorarbeiten am Fadenphantom konnten exzellent die Probleme des 3D-Ultraschalls mit der achsenabh{\"a}ngigen Aufl{\"o}sung zeigen und erm{\"o}glichten eine schnelle Beurteilung der Bildqualit{\"a}t. Hier bestehen Einsatzm{\"o}glichkeiten in der Bewertung verschiedener Ultraschallger{\"a}te bez{\"u}glich der Tauglichkeit f{\"u}r 3D-Datenaquisition. Zur reproduzierbaren Lagerung von M{\"a}usen wurde eine Schallkopff{\"u}hrung ein sowohl f{\"u}r 3D-US als auch Kleintier-PET kompatibler Tierhalter entwickelt. Die Maus lag zur Untersuchung im angew{\"a}rmten Wasserbad auf dem Tierhalter fixiert, mit Inhalationsan{\"a}sthesie und Sauerstoff {\"u}ber eine Atemmaske versorgt. Der Zeitaufwand f{\"u}r eine 3D-US-Untersuchung betrug f{\"u}r die Akquisition etwa eine Minute. Die generierten Ultraschalldatens{\"a}tze waren von guter Qualit{\"a}t, Strukturen wie Leber, Nieren, Blase, Wirbels{\"a}ule und Lunge konnten selbst bei kleinen M{\"a}usen von unter 20 Gramm K{\"o}rpergewicht gut dargestellt werden. Zur Validierung des 3D-Ultraschalls wurde das Volumen verschiedener Organe und Tumore bestimmt und mit dem Goldstandard verglichen. Um die Koregistrierung mit der Kleintier-PET zu erm{\"o}glichen, wurden auf dem Tierhalter drei „fiducial markers" angebracht, die Position und Orientierung eindeutig definieren. Die Kleintier-PET-Untersuchungen wurden nach standardisierten Protokollen durchgef{\"u}hrt. Die anschließende Bildfusion erfolgte mittels der frei verf{\"u}gbaren Software "Amide". Diskussion: Mit dem in dieser Arbeit beschriebenen Verfahren ist eine standardisierte Gewinnung von 3D-US-Datens{\"a}tzen an Kleintieren m{\"o}glich; zus{\"a}tzlich konnte die Machbarkeit der Bildfusion mit PET-Datens{\"a}tzen gezeigt werden. Der Einsatz des 3D-Ultraschalls in longitudinalen Studien, zum Beispiel zur Beurteilung der Tumorprogression, ist vorstellbar. Die Zuverl{\"a}ssigkeit der volumetrischen Berechnungen ist f{\"u}r gr{\"o}ßere Organvolumina gut, bei kleineren Volumina besteht noch Optimierungsbedarf. Weitere Verbesserungen k{\"o}nnten durch den Einsatz von speziellen Schallk{\"o}pfen und h{\"o}heren Schallfrequenzen erzielt werden.}, subject = {Ultraschalldiagnostik}, language = {de} } @phdthesis{Omert2017, author = {Omert, Leilah Marie-Luise}, title = {Einfluss systemischer Therapie auf die funktionelle Bildgebung des Multiplen Myeloms}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-154793}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2017}, abstract = {Das Multiple Myelom (MM) ist eine maligne h{\"a}matologische Erkrankung, die trotz großer Fortschritte in der Therapie immer noch eine schlechte Prognose hat. Bisher ist es nicht m{\"o}glich, mit einem bildgebenden Verfahren alle Fragen der Diagnostik, der Stadieneinteilung, des Therapiemonitorings und der Evaluation der Prognose des Multiplen Myeloms zu kl{\"a}ren. Da es sich beim Multiplen Myelom aber um eine stark heterogene Erkrankung handelt, die eine fr{\"u}hzeitige individuelle Therapie erfordert, ist es unbedingt n{\"o}tig Verfahren zu entwickeln, die eine spezifische Charakterisierung der Erkrankung bei jedem einzelnen Patienten erm{\"o}glichen. In der vorliegenden Arbeit wurden die MM-Zelllinien INA-6, MM.1S und OPM-2 mit dem Proteasominhibitor MLN9708 behandelt. Behandelte und unbehandelte Zellen wurden mit dem Standardtracer 2-[18F]-Fluoro-2-Desoxy-D-Glukose (18F-FDG) oder dem in der Anwendung beim Multiplen Myelom neuen Aminos{\"a}uretracer [11C]-Methionin (11C-MET) inkubiert und die Aufnahme der Tracer zu bestimmten Zeitpunkten gemessen. Des Weiteren wurde die Auspr{\"a}gung biologischer Merkmale der MM-Pathogenese bei behandelten und unbehandelten Zellen untersucht. Anschließend wurde ermittelt, ob ein Zusammenhang zwischen der H{\"o}he der Traceraufnahme und der Auspr{\"a}gung biologischer Merkmale der MM-Pathogenese bei behandelten und unbehandelten Zellen besteht. Hierdurch soll gekl{\"a}rt werden, ob 11C-MET besser zur Diagnostik, dem Therapiemonitoring und der Evaluation der Prognose des Multiplen Myeloms geeignet ist als der Standardtracer 18F-FDG. Es zeigte sich eine signifikant h{\"o}here 11C-MET-Aufnahme sowohl unbehandelter als auch behandelter Zellen im Vergleich zu 18F-FDG. Außerdem war eine Unterscheidung zwischen behandelten und unbehandelten Zellen mit 11C-MET besser m{\"o}glich als mit 18F-FDG. Zwischen Traceraufnahme und biologischen Merkmalen der MM-Pathogenese, wie Proliferation, Expression von intrazellul{\"a}ren Leichtketten, CXCR4 und CD138, ergaben sich f{\"u}r behandelte und unbehandelte Zellen variable Zusammenh{\"a}nge. Die Ergebnisse legen nahe, dass 11C-MET besser zur Diagnostik und zum Therapiemonitoring des Multiplen Myeloms geeignet ist als der Standardtracer 18F-FDG. Ob 11C-MET auch zur Stadieneinteilung und zur Evaluation der Prognose des Multiplen Myeloms besser geeignet ist als 18F-FDG, muss in weiteren Studien untersucht werden.}, subject = {Multiples Myelom}, language = {de} } @phdthesis{Herterich2023, author = {Herterich, Theresia Margarete Barbara}, title = {Die Wertigkeit der PET/CT in der Detektion zervikaler Lymphknotenmetastasen beim oralen Plattenepithelkarzinom}, doi = {10.25972/OPUS-31402}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-314021}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2023}, abstract = {Das orale Plattenepithelkarzinom z{\"a}hlt zu den h{\"a}ufigen Krebserkrankungen in Deutschland. Das Vorhandensein von zervikalen Lymphknotenmetastasen ist dabei einer der wichtigsten prognostischen Faktoren. F{\"u}r die Therapieplanung ist eine zuverl{\"a}ssige pr{\"a}operative Diagnostik unerl{\"a}sslich. Etablierte bildgebende Stagingverfahren (Sonographie, MRT, CT) orientieren sich allein an morphologischen Kriterien. Die PET/CT verspricht durch die Kombination funktioneller und morphologischer Verfahren die Detektion lymphoregion{\"a}rer Metastasen. Ein weiterer Vorteil scheint der Nachweis simultaner Zweitmalignome und Fernmetastasen zu sein. 135 Patienten mit einem prim{\"a}ren oralen Plattenepithelkarzinom erhielten im Rahmen der pr{\"a}operativen Staginguntersuchungen eine PET/CT-Untersuchung. Untersucht wurde der korrekte Nachweis (Sensitivit{\"a}t) bzw. Ausschluss (Spezifit{\"a}t) zervikaler Lymphknotenmetastasen sowie die Detektion (Trefferquote) von simultanen Zweitmalignomen durch die PET/CT. Die PET/CT zeigte eine Sensitivit{\"a}t von 82,9 \% und eine Spezifit{\"a}t von 84 \%. Simultane Zweitmalignome wurden mit einer Trefferquote von 62,5 \% durch die PET/CT erkannt. Das diagnostische Potenzial konnte in unserer Studie best{\"a}tigt werden. Vergleichende Studien zu den etablierten bildgebenden Verfahren w{\"a}ren w{\"u}nschenswert.}, subject = {Emissions-Computertomographie}, language = {de} } @article{SchadtIsraelSamnick2021, author = {Schadt, Fabian and Israel, Ina and Samnick, Samuel}, title = {Development and Validation of a Semi-Automated, Preclinical, MRI-Template Based PET Image Data Analysis Tool for Rodents}, series = {Frontiers in Neuroinformatics}, volume = {15}, journal = {Frontiers in Neuroinformatics}, issn = {1662-5196}, doi = {10.3389/fninf.2021.639643}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-240289}, year = {2021}, abstract = {AimIn PET imaging, the different types of radiotracers and accumulations, as well as the diversity of disease patterns, make the analysis of molecular imaging data acquired in vivo challenging. Here, we evaluate and validate a semi-automated MRI template-based data analysis tool that allows preclinical PET images to be aligned to a self-created PET template. Based on the user-defined volume-of-interest (VOI), image data can then be evaluated using three different semi-quantitative parameters: normalized activity, standardized uptake value, and uptake ratio. Materials and MethodsThe nuclear medicine Data Processing Analysis tool (NU_DPA) was implemented in Matlab. Testing and validation of the tool was performed using two types of radiotracers in different kinds of stroke-related brain diseases in rat models. The radiotracers used are 2-[\(^{18}\)F]fluoro-2-deoxyglucose ([\(^{18}\)F]FDG), a metabol\(^{68}\)Ga]Ga-Fucoidan, a target-selective radioligand specifically binding to p-selectin. After manual image import, the NU_DPA tool automatically creates an averaged PET template out of the acquired PET images, to which all PET images are then aligned onto. The added MRI template-based information, resized to the lower PET resolution, defines the VOI and also allows a precise subdivision of the VOI into individual sub-regions. The aligned PET images can then be evaluated semi-quantitatively for all regions defined in the MRI atlas. In addition, a statistical analysis and evaluation of the semi-quantitative parameters can then be performed in the NU_DPA tool. ResultsUsing ischemic stroke data in Wistar rats as an example, the statistical analysis of the tool should be demonstrated. In this [\(^{18}\)F]FDG-PET experiment, three different experimental states were compared: healthy control state, ischemic stroke without electrical stimulation, ischemic stroke with electrical stimulation. Thereby, statistical data evaluation using the NU_DPA tool showed that the glucose metabolism in a photothrombotic lesion can be influenced by electrical stimulation. ConclusionOur NU_DPA tool allows a very flexible data evaluation of small animal PET data in vivo including statistical data evaluation. Using the radiotracers [\(^{18}\)F]FDG and [\(^{68}\)Ga]Ga-Fucoidan, it was shown that the semi-automatic MRI-template based data analysis of the NU_DPA tool is potentially suitable for both metabolic radiotracers as well as target-selective radiotracers.}, language = {en} } @article{LapaHerrmannSchirbeletal.2017, author = {Lapa, Constantin and Herrmann, Ken and Schirbel, Andreas and H{\"a}nscheid, Heribert and L{\"u}ckerath, Katharina and Schottelius, Margret and Kircher, Malte and Werner, Rudolf A. and Schreder, Martin and Samnick, Samuel and Kropf, Saskia and Knop, Stefan and Buck, Andreas K. and Einsele, Hermann and Wester, Hans-Juergen and Kort{\"u}m, K. Martin}, title = {CXCR4-directed endoradiotherapy induces high response rates in extramedullary relapsed multiple myeloma}, series = {Theranostics}, volume = {7}, journal = {Theranostics}, number = {6}, doi = {10.7150/thno.19050}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-172095}, pages = {1589-1597}, year = {2017}, abstract = {C-X-C-motif chemokine receptor 4 (CXCR4) is a key factor for tumor growth and metastasis in several types of human cancer. We have recently reported promising first-in-man experience with CXCR4-directed endoradiotherapy (ERT) in multiple myeloma (MM). Eight heavily pretreated MM patients underwent a total of 10 ERT cycles (7 patients with 1 cycle and a single patient with 3 cycles). ERT was administered in combination with chemotherapy and autologous stem cell support. End points were occurrence and timing of adverse events, progression-free and overall survival. ERT was overall well tolerated without any unexpected acute adverse events or changes in vital signs. With absorbed tumor doses >30-70 Gy in intra- or extramedullary lesions, significant anti-myeloma activity was observed with 1 patient achieving complete remission and 5/8 partial remission. Directly after ERT major infectious complications were seen in one patient who died from sepsis 22 days after ERT, another patient with high tumor burden experienced lethal tumor lysis syndrome. Median progression-free survival was 54 days (range, 13-175), median overall survival was 223 days (range, 13-313). During follow-up (6 patients available), one patient died from infectious complications, 2/8 from disease progression, the remaining 3/8 patients are still alive. CXCR4-directed ERT was well-tolerated and exerted anti-myeloma activity even at very advanced stage MM with presence of extramedullary disease. Further assessment of this novel treatment option is highly warranted.}, language = {en} } @article{UeceylerBuchholzKewenigetal.2020, author = {{\"U}{\c{c}}eyler, Nurcan and Buchholz, Hans-Georg and Kewenig, Susanne and Ament, Stephan-Johann and Birklein, Frank and Schreckenberger, Mathias and Sommer, Claudia}, title = {Cortical Binding Potential of Opioid Receptors in Patients With Fibromyalgia Syndrome and Reduced Systemic Interleukin-4 Levels - A Pilot Study}, series = {Frontiers in Neuroscience}, volume = {14}, journal = {Frontiers in Neuroscience}, issn = {1662-453X}, doi = {10.3389/fnins.2020.00512}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-204457}, year = {2020}, abstract = {Objective: We investigated cerebral opioid receptor binding potential in patients with fibromyalgia syndrome (FMS) using positron-emission-tomography (PET) and correlated our results with patients' systemic interleukin-4 (IL-4) gene expression. Methods: In this pilot study, seven FMS patients (1 man, 6 women) agreed to participate in experimental PET scans. All patients underwent neurological examination, were investigated with questionnaires for pain, depression, and FMS symptoms. Additionally, blood for IL-4 gene expression analysis was withdrawn at two time points with a median latency of 1.3 years. Patients were investigated in a PET scanner using the opioid receptor ligand F-18-fluoro-ethyl-diprenorphine ([18F]FEDPN) and results were compared with laboratory normative values. Results: Neurological examination was normal in all FMS patients. Reduced opioid receptor binding was found in mid cingulate cortex compared to healthy controls (p < 0.005). Interestingly, three patients with high systemic IL-4 gene expression had increased opioid receptor binding in the fronto-basal cortex compared to those with low IL-4 gene expression (p < 0.005). Conclusion: Our data give further evidence for a reduction in cortical opioid receptor availability in FMS patients as another potential central nervous system contributor to pain in FMS.}, language = {en} } @phdthesis{Richter2014, author = {Richter, Dominik}, title = {Compressed Sensing zur Filterung und Reduktion der Rekonstruktionszeit in der Positronen-Emissions-Tomographie}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-106569}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2014}, abstract = {Durch die Verwendung radioaktiver Substanzen mit ihrer sch{\"a}digenden Wirkung auf den menschlichen K{\"o}rper besteht in der Positronen-Emissions-Tomographie (PET) ein fortw{\"a}hrendes Interesse an der Reduktion der applizierten Dosis bei gleichbleibender Qualit{\"a}t der Ergebnisse. Zus{\"a}tzlich ist im Hinblick auf die Wirtschaftlichkeit der Systeme eine Reduktion sowohl der Akquisitions- als auch der Rekonstruktionszeit erstrebenswert. In dieser Arbeit werden zwei M{\"o}glichkeiten vorgestellt, diese Ziele durch den Einsatz von Compressed Sensing (CS) zu erreichen. Neben der Entwicklung neuartiger Rekonstruktionsalgorithmen k{\"o}nnen Filtertechniken eingesetzt werden, um eine qualitative Verbesserung rekonstruierter Bilder zu erzielen. Der Vorteil eines Filters besteht unter anderem darin, dass diese retrospektiv angewandt werden k{\"o}nnen. Es ist folglich m{\"o}glich, die Qualit{\"a}t eines Bildes zu {\"u}berpr{\"u}fen und lediglich im Bedarfsfall einen Filter einzusetzen. Die Technik des CS war in den letzten Jahren Gegenstand zahlreicher Forschungsarbeiten im Bereich der Bildgebung, insbesondere in der Magnetresonanztomographie und der Computertomographie (CT). Mit CS k{\"o}nnten bildgebende Verfahren wie die CT oder die PET mit weniger Messungen durchgef{\"u}hrt werden, wodurch sich die Messzeit und die Strahlenexposition reduziert. In der molekularen Bildgebung mit der PET ist CS jedoch weitgehend unbekannt. Im ersten Teil dieser Dissertation wird eine Methode vorgestellt, welche CS als Filtertechnik in der PET einsetzt. Den Ausgangspunkt stellt ein vollst{\"a}ndiger, analytisch rekonstruierter Datensatz dar. Dieser wird mit einer Reihe unterschiedlicher Abtastmuster retrospektiv unterabgetastet und jeweils erneut, unter Verwendung von CS rekonstruiert. Im rauschfreien Fall w{\"u}rde CS stets das Originalbild liefern. Das {\"u}berlagerte Rauschen f{\"u}hrt jedoch zu Artefakten und einer Verschlechterung des Ergebnisses. CS kann nun einerseits das Rauschen vermindern. Andererseits ist es durch die Mittelung mehrerer unterschiedlicher Rekonstruktionen m{\"o}glich, die Artefakte zu reduzieren. Auf diesem Weg kann die Bildqualit{\"a}t signifikant verbessert werden. Es konnte gezeigt werden, dass die Technik sowohl f{\"u}r 2D, als auch f{\"u}r 3D Datens{\"a}tze verwendet werden kann. Die gr{\"o}ßten qualitativen Verbesserungen werden erzielt, wenn der Datensatz lediglich aus wenigen Ereignissen besteht. In diesem Fall ist die Bildqualit{\"a}t der analytischen Rekonstruktionen extrem schlecht, die Verbesserung durch die Filtertechnik mit CS und die damit verbundene Erh{\"o}hung des Signal-Rausch-Verh{\"a}ltnisses jedoch am gr{\"o}ßten. Bei diesen Datens{\"a}tzen k{\"o}nnen die Ergebnisse iterativer Rekonstruktionen {\"u}bertroffen werden. In der Praxis w{\"a}re damit ein Einsatz speziell bei dynamischen oder getriggerten Aufnahmen denkbar. In beiden F{\"a}llen basieren die Rekonstruktionen nicht selten auf wenigen Ereignissen. Die resultierenden Bilder sind h{\"a}ufig von schlechter Qualit{\"a}t, womit eine Verbesserung durch Filterung sinnvoll ist. Der zweite Teil dieser Arbeit besch{\"a}ftigt sich mit der Rohdaten-basierten Triggerung am Kleintier-PET sowie mit dem Einsatz von CS zur Reduktion der Rekonstruktionszeit. Fr{\"u}here Ver{\"o}ffentlichungen zeigten bereits die Anwendbarkeit Rohdaten-basierter Triggermethoden bei humanen Datens{\"a}tzen. Im Hinblick auf eine pr{\"a}klinische Anwendung, speziell bei Datens{\"a}tzen mit dem Fokus auf M{\"a}useherzen, existieren jedoch nur wenige Studien. In dieser Arbeit wird gezeigt, dass die segmentierte Methode des Massenschwerpunkts (COMseg) eine Technik darstellt, welche die kardiale Triggerung sowohl bei Datens{\"a}tzen von Ratten, als auch von M{\"a}usen erlaubt. Ein nicht zu untersch{\"a}tzender Nachteil der COMseg besteht darin, dass vor deren Anwendung die List-Mode Datei in kleine Zeitframes unterteilt und in Sinogramme sortiert werden muss. Auf jedes Sinogramm wird im Anschluss ein Rebinning Algorithmus angewandt. Dies stellt einen enormen Zeitaufwand dar, wodurch sich eine Anwendung bei gr{\"o}ßeren Studien in der Praxis als schwierig erweist. Ziel der Triggermethoden ist die Gewinnung eines Triggersignals, durch welches beispielsweise der Herzschlag in mehrere Phasen aufgeteilt werden kann. Das Triggersignal hat f{\"u}r gew{\"o}hnlich eine d{\"u}nnbesetzte Repr{\"a}sentation im Frequenzraum. Dieses Vorwissen erm{\"o}glicht den Einsatz von CS. Anstelle des vollst{\"a}ndigen Datensatzes wurde lediglich ein Teil der Daten in kleine Zeitframes sortiert und mit der COMseg ausgewertet. Aus diesem unterabgetasteten Datensatz wird mit Hilfe von CS das vollst{\"a}ndige Triggersignal rekonstruiert. Die St{\"a}rke der Unterabtastung entspricht in etwa dem Faktor der Reduktion der Rekonstruktionszeit. Auf diesem Weg ist es m{\"o}glich, eine signifikante Beschleunigung zu erzielen. Die Anwendung dieser Technik ist jedoch nicht auf die COMseg beschr{\"a}nkt. Prinzipiell kann das Verfahren bei allen Methoden der Rohdaten-basierten Triggerung angewandt werden, welche es erlauben, die Abtastpunkte des Signals separat zu berechnen. Damit werden Algorithmen interessant, deren Einsatz aufgrund aufw{\"a}ndiger Berechnungen bislang in der Praxis nicht sinnvoll war. Zusammenfassend legen die in dieser Arbeit vorgestellten Daten nahe, dass CS ein neuartiges Werkzeug in der PET darstellen k{\"o}nnte, mit welchem eine Filterung von Bildern sowie eine Reduktion der Rekonstruktionszeit m{\"o}glich ist.}, subject = {Komprimierte Abtastung}, language = {de} } @article{IsraelOhsiekAlMomanietal.2016, author = {Israel, Ina and Ohsiek, Andrea and Al-Momani, Ehab and Albert-Weissenberger, Christiane and Stetter, Christian and Mencl, Stine and Buck, Andreas K. and Kleinschnitz, Christoph and Samnick, Samuel and Sir{\´e}n, Anna-Leena}, title = {Combined [\(^{18}\)F]DPA-714 micro-positron emission tomography and autoradiography imaging of microglia activation after closed head injury in mice}, series = {Journal of Neuroinflammation}, volume = {13}, journal = {Journal of Neuroinflammation}, number = {140}, doi = {10.1186/s12974-016-0604-9}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-146606}, year = {2016}, abstract = {Background Traumatic brain injury (TBI) is a major cause of death and disability. Neuroinflammation contributes to acute damage after TBI and modulates long-term evolution of degenerative and regenerative responses to injury. The aim of the present study was to evaluate the relationship of microglia activation to trauma severity, brain energy metabolism, and cellular reactions to injury in a mouse closed head injury model using combined in vivo PET imaging, ex vivo autoradiography, and immunohistochemistry. Methods A weight-drop closed head injury model was used to produce a mixed diffuse and focal TBI or a purely diffuse mild TBI (mTBI) in C57BL6 mice. Lesion severity was determined by evaluating histological damage and functional outcome using a standardized neuroscore (NSS), gliosis, and axonal injury by immunohistochemistry. Repeated intra-individual in vivo μPET imaging with the specific 18-kDa translocator protein (TSPO) radioligand [\(^{18}\)F]DPA-714 was performed on day 1, 7, and 16 and [\(^{18}\)F]FDG-μPET imaging for energy metabolism on days 2-5 after trauma using freshly synthesized radiotracers. Immediately after [\(^{18}\)F]DPA-714-μPET imaging on days 7 and 16, cellular identity of the [\(^{18}\)F]DPA-714 uptake was confirmed by exposing freshly cut cryosections to film autoradiography and successive immunostaining with antibodies against the microglia/macrophage marker IBA-1. Results Functional outcome correlated with focal brain lesions, gliosis, and axonal injury. [\(^{18}\)F]DPA-714-μPET showed increased radiotracer uptake in focal brain lesions on days 7 and 16 after TBI and correlated with reduced cerebral [\(^{18}\)F]FDG uptake on days 2-5, with functional outcome and number of IBA-1 positive cells on day 7. In autoradiography, [\(^{18}\)F]DPA-714 uptake co-localized with areas of IBA1-positive staining and correlated strongly with both NSS and the number of IBA1-positive cells, gliosis, and axonal injury. After mTBI, numbers of IBA-1 positive cells with microglial morphology increased in both brain hemispheres; however, uptake of [\(^{18}\)F]DPA-714 was not increased in autoradiography or in μPET imaging. Conclusions [\(^{18}\)F]DPA-714 uptake in μPET/autoradiography correlates with trauma severity, brain metabolic deficits, and microglia activation after closed head TBI.}, language = {en} } @article{GriebschKernHansenetal.2022, author = {Griebsch, Nora-Isabell and Kern, Johanna and Hansen, Jonas and Rullmann, Michael and Luthardt, Julia and Helfmeyer, Stephanie and Dekorsy, Franziska J. and Soeder, Marvin and Hankir, Mohammed K. and Zientek, Franziska and Becker, Georg-Alexander and Patt, Marianne and Meyer, Philipp M. and Dietrich, Arne and Bl{\"u}her, Matthias and Ding, Yu-Shin and Hilbert, Anja and Sabri, Osama and Hesse, Swen}, title = {Central serotonin/noradrenaline transporter availability and treatment success in patients with obesity}, series = {Brain Sciences}, volume = {12}, journal = {Brain Sciences}, number = {11}, issn = {2076-3425}, doi = {10.3390/brainsci12111437}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-290294}, year = {2022}, abstract = {Serotonin (5-hydroxytryptamine, 5-HT) as well as noradrenaline (NA) are key modulators of various fundamental brain functions including the control of appetite. While manipulations that alter brain serotoninergic signaling clearly affect body weight, studies implicating 5-HT transporters and NA transporters (5-HTT and NAT, respectively) as a main drug treatment target for human obesity have not been conclusive. The aim of this positron emission tomography (PET) study was to investigate how these central transporters are associated with changes of body weight after 6 months of dietary intervention or Roux-en-Y gastric bypass (RYGB) surgery in order to assess whether 5-HTT as well as NAT availability can predict weight loss and consequently treatment success. The study population consisted of two study cohorts using either the 5-HTT-selective radiotracer [\(^{11}\)C]DASB to measure 5-HTT availability or the NAT-selective radiotracer [\(^{11}\)C]MRB to assess NAT availability. Each group included non-obesity healthy participants, patients with severe obesity (body mass index, BMI, >35 kg/m\(^2\)) following a conservative dietary program (diet) and patients undergoing RYGB surgery within a 6-month follow-up. Overall, changes in BMI were not associated with changes of both 5-HTT and NAT availability, while 5-HTT availability in the dorsal raphe nucleus (DRN) prior to intervention was associated with substantial BMI reduction after RYGB surgery and inversely related with modest BMI reduction after diet. Taken together, the data of our study indicate that 5-HTT and NAT are involved in the pathomechanism of obesity and have the potential to serve as predictors of treatment outcomes.}, language = {en} } @inproceedings{WernerHayakawaAriasLozaetal.2017, author = {Werner, Rudolf and Hayakawa, Nobuyuki and Arias-Loza, Paula-Anah and Wakabayashi, Hiroshi and Shinaji, Tetsuya and Lapa, Constantin and Pelzer, Theo and Higuchi, Takahiro}, title = {Bildgebung der fr{\"u}hen linksventrikul{\"a}ren Dysfunktion mit ECG-gated F-18-FDG PET in einem Diabetes-Ratten-Modell}, series = {Nuklearmedizin}, volume = {56}, booktitle = {Nuklearmedizin}, number = {2}, publisher = {Schattauer Verlag}, issn = {0029-5566}, doi = {10.3413/Nukmed-0880-17-02}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-161396}, pages = {Abstract Nr.: V119}, year = {2017}, abstract = {Einleitung: Die linksventrikul{\"a}re diastolische Dysfunktion (LVDD) ist bei Diabetikern noch vor Entwicklung einer klinisch apparenten Herzinsuffizienz eines der ersten Anzeichen einer kardialen Beteiligung. Daher soll in dieser Studie untersucht werden, ob die LVDD mit ECG-gated F-18-FDG PET in einem Diabetes-Rattenmodell dargestellt werden kann. Methodik: Es wurden F-18-FDG PET Scans in einem Typ-2-Diabetes Rattenmodell (ZDF fa/fa, n=6) und in ZL Kontrollen (n=6) vorgenommen (Alter, jeweils 13 Wochen). Unter Hyperinsulinemic-Euglycemic Clamp-Technik wurden 37 MBq 18F-FDG {\"u}ber die Schwanzvene appliziert. 15-35 Minuten nach Tracergabe wurden mittels eines Kleintier-PET-Scanners sowie unter EKG-Ableitung PET Scans angefertigt (16 frames/cardiac cycle). Die linksventrikul{\"a}re Ejektionsfraktion (EF) und die Peak F{\"u}llrate (PFR) wurden mittels einer geeigneten Software (Heart Function View) gemessen, wobei die Software an die Gr{\"o}ße des Rattenherzes angepasst wurde. Ergebnisse: Im Alter von 13 Wochen entwickeln ZDF Diabetes-Ratten eine im Vergleich zu Kontrolltieren eine signifikante myokardiale Hypertrophie, best{\"a}tigt durch post-mortem Analyse des Herzgewichtes (994±78mg vs. 871±44mg in ZDF Diabetes-Ratten vs. ZL Kontrollen, p<0.01). ECG-gated PET zeigte eine signifikante Abnahme der LV diastolischen PFR (10.4±0.5 vs. 11.8±0.4 EDV/sec in ZDF Diabetes-Ratten vs. ZL Kontrollen, p<0.001), jedoch zeigte sich kein signifikanter Unterschied zwischen LVEF und der Herzfrequenz in den untersuchten ZDF Diabetes-Ratten und Kontrollen (LVEF: 60.0±4.5 vs. 63.7±4.1\%, n.s. und HR: 305±25 vs. 323±24 bpm, n.s.). Schlussfolgerung: Im Diabetes-Ratten-Modell kann unter Verwendung eines ECG-gated FDG-PET Protokolls die diastolische Dysfunktion als Parameter der fr{\"u}hen diabetischen Kardiomyopathie nachgewiesen werden.}, subject = {Positronen-Emissions-Tomografie}, language = {de} } @article{KosmalaSerflingDreheretal.2022, author = {Kosmala, Aleksander and Serfling, Sebastian E. and Dreher, Niklas and Lindner, Thomas and Schirbel, Andreas and Lapa, Constantin and Higuchi, Takahiro and Buck, Andreas K. and Weich, Alexander and Werner, Rudolf A.}, title = {Associations between normal organs and tumor burden in patients imaged with fibroblast activation protein inhibitor-directed positron emission tomography}, series = {Cancers}, volume = {14}, journal = {Cancers}, number = {11}, issn = {2072-6694}, doi = {10.3390/cancers14112609}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-275154}, year = {2022}, abstract = {(1) Background: We aimed to quantitatively investigate [\(^{68}\)Ga]Ga-FAPI-04 uptake in normal organs and to assess a relationship with the extent of FAPI-avid tumor burden. (2) Methods: In this single-center retrospective analysis, thirty-four patients with solid cancers underwent a total of 40 [\(^{68}\)Ga]Ga-FAPI-04 PET/CT scans. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were established by placing volumes of interest (VOIs) in the heart, liver, spleen, pancreas, kidneys, and bone marrow. Total tumor burden was determined by manual segmentation of tumor lesions with increased uptake. For tumor burden, quantitative assessment included maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA = TV × SUV\(_{mean}\)). Associations between uptake in normal organs and tumor burden were investigated by applying Spearman's rank correlation coefficient. (3) Results: Median SUV\(_{mean}\) values were 2.15 in the pancreas (range, 1.05-9.91), 1.42 in the right (range, 0.57-3.06) and 1.41 in the left kidney (range, 0.73-2.97), 1.2 in the heart (range, 0.46-2.59), 0.86 in the spleen (range, 0.55-1.58), 0.65 in the liver (range, 0.31-2.11), and 0.57 in the bone marrow (range, 0.26-0.94). We observed a trend towards significance for uptake in the myocardium and tumor-derived SUV\(_{max}\) (ρ = 0.29, p = 0.07) and TV (ρ = -0.30, p = 0.06). No significant correlation was achieved for any of the other organs: SUV\(_{max}\) (ρ ≤ 0.1, p ≥ 0.42), TV (ρ ≤ 0.11, p ≥ 0.43), and FTA (ρ ≤ 0.14, p ≥ 0.38). In a sub-analysis exclusively investigating patients with high tumor burden, significant correlations of myocardial uptake with tumor SUV\(_{max}\) (ρ = 0.44; p = 0.03) and tumor-derived FTA with liver uptake (ρ = 0.47; p = 0.02) were recorded. (4) Conclusions: In this proof-of-concept study, quantification of [\(^{68}\)Ga]Ga-FAPI-04 PET showed no significant correlation between normal organs and tumor burden, except for a trend in the myocardium. Those preliminary findings may trigger future studies to determine possible implications for treatment with radioactive FAP-targeted drugs, as higher tumor load or uptake may not lead to decreased doses in the majority of normal organs.}, language = {en} } @article{VermaKehrerHesseretal.2020, author = {Verma, Shwetabh and Kehrer, Tobias and Hesser, J{\"u}rgen and Arba Mosquera, Samuel}, title = {Analysis of Impact of Humidity and Temperature on Excimer Laser Ablation of Polyethylene Terephthalate, Polymethylmethacrylate, and Porcine Corneal Tissue}, series = {Lasers in Surgery and Medicine}, volume = {52}, journal = {Lasers in Surgery and Medicine}, number = {7}, doi = {10.1002/lsm.23190}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-213395}, pages = {627 -- 638}, year = {2020}, abstract = {Background and Objectives To analyze the impact of humidity and temperature on excimer laser ablation of polyethylene terephthalate (PET), polymethylmethacrylate (PMMA) and porcine corneal tissue, and an ablation model to compensate for the temperature and humidity changes on ablation efficiency. Study Design/Materials and Methods The study was conducted using an AMARIS 1050RS (Schwind eye-tech-solutions) placed inside a climate chamber at ACTS. Ablations were performed on PET, PMMA, and porcine cornea. The impact of a wide range of temperature (~18°C to ~30°C) and relative humidity (~25\% to ~80\%) on laser ablation outcomes was tested using nine climate test settings. For porcine eyes, change in defocus was calculated from the difference of post-ablation to pre-ablation average keratometry readings. Laser scanning deflectometry was performed to measure refractive change achieved in PMMA. Multiple linear regression was performed using the least square method with predictive factors: temperature, relative humidity, time stamp. Influence of climate settings was modeled for pulse energy, pulse fluence, ablation efficiency on PMMA and porcine cornea tissue. Results Temperature changes did not affect laser pulse energy, pulse fluence (PET), and ablation efficiency (on PMMA or porcine corneal tissue) significantly. Changes in relative humidity were critical and significantly affected laser pulse energy, high fluence and low fluence. The opposite trend was observed between the ablation performance on PMMA and porcine cornea. Conclusions The proposed well-fitting multi-linear model can be utilized for compensation of temperature and humidity changes on ablation efficiency. Based on this model, a working window for optimum operation has been found (temperature 18°C to 28°C and relative humidity 25\% to 65\%) for a maximum deviation of ±2.5\% in ablation efficiency in PMMA and porcine corneal tissue.}, language = {en} } @unpublished{WernerAndreeJavadietal.2018, author = {Werner, Rudolf A. and Andree, Christian and Javadi, Mehrbod S. and Lapa, Constantin and Buck, Andreas K. and Higuchi, Takahiro and Pomper, Martin G. and Gorin, Michael A. and Rowe, Steven P. and Pienta, Kenneth J.}, title = {A Voice From the Past: Re-Discovering the Virchow Node with PSMA-targeted \(^{18}\)F-DCFPyL PET Imaging}, series = {Urology - The Gold Journal}, journal = {Urology - The Gold Journal}, issn = {0090-4295}, doi = {10.1016/j.urology.2018.03.030}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-161103}, year = {2018}, abstract = {No abstract available.}, subject = {Virchow Node}, language = {en} } @article{WernerAndreeJavadietal.2018, author = {Werner, Rudolf A. and Andree, Christian and Javadi, Mehrbod S. and Lapa, Constantin and Buck, Andreas K. and Higuchi, Takahiro and Pomper, Martin G. and Gorin, Michael A. and Rowe, Steven P. and Pienta, Kenneth J.}, title = {A Voice From the Past: Re-Discovering the Virchow Node with PSMA-targeted \(^{18}\)F-DCFPyL PET Imaging}, series = {Urology - The Gold Journal}, volume = {117}, journal = {Urology - The Gold Journal}, issn = {0090-4295}, doi = {10.1016/j.urology.2018.03.030}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-164632}, pages = {18-21}, year = {2018}, abstract = {No abstract available.}, language = {en} }