@article{StreckForstervonHertzbergBoelchetal.2022, author = {Streck, Laura Elisa and Forster, Johannes and von Hertzberg-Boelch, Sebastian Philipp and Reichel, Thomas and Rudert, Maximilian and Rueckl, Kilian}, title = {The role of synovial fluid aspiration in shoulder joint infections}, series = {BMC Musculoskeletal Disorders}, volume = {23}, journal = {BMC Musculoskeletal Disorders}, doi = {10.1186/s12891-022-05285-x}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300795}, year = {2022}, abstract = {Background Joint aspiration with analysis of synovial fluid white blood cell count (WBC) and microbiological culture is a widely established aspect in the diagnosis of shoulder joint infections (SJI). In case of a two stage revision for SJI, joint aspiration before re-/implantation of a total shoulder arthroplasty (TSA) was used to rule out persistent infection for years but its value is under debate. Shoulder specific data on all aspects is rare. The current study aims to answer the following research questions: Does joint aspiration have an insufficient predictive value in the diagnosis of SJI in (1) initial workup and (2) before definite arthroplasty with polymethylmethacrylate (PMMA)-Spacer in place? Methods This retrospective evaluation investigates 35 patients that were treated for SJI with a two staged implantation of a TSA after debridement and implantation of an PMMA-Spacer. Joint aspirations were performed preoperatively (PA) and before re-/implantation of the prosthesis while spacer was in place (interstage aspiration, IA). Samples were taken for microbiological culture and analysis of WBC. Sensitivity and specificity were calculated with reference to intraoperative microbiological samples. Receiver Operating Characteristic (ROC), Area-Under-Curve analysis (AUC) and calculation of the Youden index were performed to find optimum cut-off for WBC. Results The sensitivity of microbiological cultures from PA was 58.3\% and the specificity was 88.9\%. The mean WBC was 27,800 leucocytes/mm3 (range 400-96,300). The maximum Youden index (0.857) was a cut-off of 2600 leucocytes/mm3 with a sensitivity of 85.7\% and a specificity of 100.0\%. The sensitivity and specificity of IA were 0.0\% and 88.5\%, respectively. Conclusions Preoperative aspiration is likely to miss Cutibacteria spp. and CoNS and cannot rule out infection for sure. However, we recommend it for its advantages of targeted antibiotic therapy in case of germ identification. Empiric antibiotic therapy should cover Cutibacteria and CoNS even if aspiration showed negative microbiological cultures. In contrast, the diagnostic value of interstage aspiration does not qualify for its routine use.}, language = {en} } @article{vonHertzbergBoelchLuedemannRudertetal.2022, author = {von Hertzberg-Boelch, Sebastian Philipp and Luedemann, Martin and Rudert, Maximilian and Steinert, Andre F.}, title = {PMMA bone cement: antibiotic elution and mechanical properties in the context of clinical use}, series = {Biomedicines}, volume = {10}, journal = {Biomedicines}, number = {8}, issn = {2227-9059}, doi = {10.3390/biomedicines10081830}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-281708}, year = {2022}, abstract = {This literature review discusses the use of antibiotic loaded polymethylmethacrylate bone cements in arthroplasty. The clinically relevant differences that have to be considered when antibiotic loaded bone cements (ALBC) are used either for long-term implant fixation or as spacers for the treatment of periprosthetic joint infections are outlined. In this context, in vitro findings for antibiotic elution and material properties are summarized and transferred to clinical use.}, language = {en} } @article{LuedemannJakuscheitEwaldetal.2021, author = {L{\"u}demann, Martin and Jakuscheit, Axel and Ewald, Andrea and Fr{\"u}hmann, Leena and H{\"o}lscher-Doht, Stefanie and Rudert, Maximilian and von Hertzberg-Boelch, Sebastian Philipp}, title = {Influence of Tranexamic Acid on Elution Characteristics and Compressive Strength of Antibiotic-Loaded PMMA-Bone Cement with Gentamicin}, series = {Materials}, volume = {14}, journal = {Materials}, number = {19}, issn = {1996-1944}, doi = {10.3390/ma14195639}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-246236}, year = {2021}, abstract = {Purpose: The topical application of tranexamic acid (TXA) into the joint space during total joint arthroplasty (TJA) with no increase of complications, has been widely reported. We investigated the influence of TXA on antibiotic release, activity of the released antibiotic against a clinical isolate of S. aureus, and compressive strength of a widely used commercially prepared gentamicin-loaded cement brand (PALACOS R + G). Method: 12 bone cement cylinders (diameter and height = 6 and 12 mm, respectively) were molded. After curing in air for at least 1 h, six of the cylinders were completely immersed in 5 mL of fetal calf serum (FCS) and the other six were completely immersed in a solution consisting of 4.9 mL of FCS and 0.1 mL (10 mg) of TXA. Gentamicin elution tests were performed over 7 d. Four hundred µL of the gentamicin eluate were taken every 24 h for the first 7 d without renewing the immersion fluid. The gentamicin concentration was determined in a clinical analyzer using a homogeny enzyme immuno-assay. The antimicrobial activity of the eluate, obtained after day 7, was tested. An agar diffusion test regime was used with Staphylococcus aureus. Bacteria were grown in a LB medium and plated on LB agar plates to get a bacterial lawn. Fifty µL of each eluate were pipetted on 12-mm diameter filter discs, which were placed in the middle of the agar gel. After 24 h of cultivation at 37 °C, the zone of inhibition (ZOI) for each specimen was measured. The compressive strength of the cements was determined per ISO 5833. Results: At each time point in the gentamicin release test, the difference in gentamicin concentration, obtained from specimens immersed in the FCS solution only and those immersed in the FCS + TXA solution was not significant (p = 0.055-0.522). The same trend was seen in each of the following parameters, after 7 d of immersion: (1) Cumulative gentamicin concentration (p < 0.297); (2) gentamicin activity against S. aureus (strongly visible); (3) ZOI size (mostly > 20 mm) (p = 0.631); and (4) compressive strength (p = 0.262). Conclusions: For the PALACOS R + G specimens, the addition of TXA to FCS does not produce significant decreases in gentamicin concentration, in the activity of the gentamicin eluate against a clinical isolate of S. aureus, the zone of inhibition of S. aureus, and in the compressive strength of the cement, after 7 d of immersion in the test solution.}, language = {en} } @article{vonHertzbergBoelchWagenbrennerArnholdtetal.2021, author = {von Hertzberg-Boelch, Sebastian Philipp and Wagenbrenner, Mike and Arnholdt, J{\"o}rg and Frenzel, Stephan and Holzapfel, Boris Michael and Rudert, Maximilian}, title = {Custom Made Monoflange Acetabular Components for the Treatment of Paprosky Type III Defects}, series = {Journal of Personalized Medicine}, volume = {11}, journal = {Journal of Personalized Medicine}, number = {4}, issn = {2075-4426}, doi = {10.3390/jpm11040283}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-236513}, year = {2021}, abstract = {Purpose: Patient-specific, flanged acetabular components are used for the treatment of Paprosky type III defects during revision total hip arthroplasty (THA). This monocentric retrospective cohort study analyzes the outcome of patients treated with custom made monoflanged acetabular components (CMACs) with intra- and extramedullary iliac fixation. Methods: 14 patients were included who underwent revision THA with CMACs for the treatment of Paprosky type III defects. Mechanism of THA failure was infection in 4 and aseptic loosening in 10 patients. Seven patients underwent no previous revision, the other seven patients underwent three or more previous revisions. Results: At a mean follow-up of 35.4 months (14-94), the revision rate of the implant was 28.3\%. Additionally, one perioperative dislocation and one superficial wound infection occurred. At one year postoperatively, we found a significant improvement of the Western Ontario and McMaster Universities Arthritis Index (WOMAC) score (p = 0.015). Postoperative radiographic analysis revealed good hip joint reconstruction with a mean leg length discrepancy of 3 mm (-8-20), a mean lateralization of the horizontal hip center of rotation of 8 mm (-8-35), and a mean proximalization of the vertical hip center of rotation of 6 mm (13-26). Radiolucency lines were present in 30\%. Conclusion: CMACs can be considered an option for the treatment of acetabular bone loss in revision THA. Iliac intra- and extramedullary fixation allows soft tissue-adjusted hip joint reconstruction and improves hip function. However, failure rates are high, with periprosthetic infection being the main threat to successful outcome.}, language = {en} }