@article{KoepingShehataDielerSchneideretal.2018, author = {K{\"o}ping, Maria and Shehata-Dieler, Wafaa and Schneider, Dieter and Cebulla, Mario and Oder, Daniel and M{\"u}ntze, Jonas and Nordbeck, Peter and Wanner, Christoph and Hagen, Rudolf and Schraven, Sebastian P.}, title = {Characterization of vertigo and hearing loss in patients with Fabry disease}, series = {Orphanet Journal of Rare Diseases}, volume = {13}, journal = {Orphanet Journal of Rare Diseases}, doi = {10.1186/s13023-018-0882-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-222818}, year = {2018}, abstract = {Background Fabry Disease (FD) is an X-linked hereditary lysosomal storage disorder which leads to a multisystemic intralysosomal accumulation of globotriaosylceramid (Gb3). Besides prominent renal and cardiac organ involvement, patients commonly complain about vestibulocochlear symptoms like high-frequency hearing loss, tinnitus and vertigo. However, comprehensive data especially on vertigo remain scarce. The aim of this study was to examine the prevalence and characteristics of vertigo and hearing loss in patients with FD, depending on renal and cardiac parameters and get hints about the site and the pattern of the lesions. Methods Single-center study with 57 FD patients. Every patient underwent an oto-rhino-laryngological examination as well as videonystagmography and vestibular evoked myogenic potentials (VEMPs) and audiological measurements using pure tone audiometry and auditory brainstem response audiometry (ABR). Renal function was measured by eGFR, cardiac impairment was graduated by NYHA class. Results More than one out of three patients (35.1\%) complained about hearing loss, 54.4\% about vertigo and 28.1\% about both symptom. In 74\% a sensorineural hearing loss of at least 25 dB was found, ABR could exclude any retrocochlear lesion. Caloric testing showed abnormal values in 71.9\%, VEMPs were pathological in 68\%. A correlation between the side or the shape of hearing loss and pathological vestibular testing could not be revealed. Conclusions Hearing loss and vertigo show a high prevalence in FD. While hearing loss seems due to a cochlear lesion, peripheral vestibular as well as central nervous pathologies cause vertigo. Thus, both the site of lesion and the pathophysiological patterns seem to differ.}, language = {en} } @article{KoepingShehataDielerCebullaetal.2017, author = {K{\"o}ping, Maria and Shehata-Dieler, Wafaa and Cebulla, Mario and Rak, Kristen and Oder, Daniel and M{\"u}ntze, Jonas and Nordbeck, Peter and Wanner, Christoph and Hagen, Rudolf and Schraven, Sebastian}, title = {Cardiac and renal dysfunction is associated with progressive hearing loss in patients with Fabry disease}, series = {PLoS ONE}, volume = {12}, journal = {PLoS ONE}, number = {11}, doi = {10.1371/journal.pone.0188103}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-169961}, pages = {e0188103}, year = {2017}, abstract = {Background Fabry disease (FD) is an X-linked recessive hereditary lysosomal storage disorder which results in the accumulation of globotriaosylceramid (Gb3) in tissues of kidney and heart as well as central and peripheral nervous system. Besides prominent renal and cardiac organ involvement, cochlear symptoms like high-frequency hearing loss and tinnitus are frequently found with yet no comprehensive data available in the literature. Objective To examine hearing loss in patients with FD depending on cardiac and renal function. Material and methods Single-center study with 68 FD patients enrolled between 2012 and 2016 at the Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery of the University of W{\"u}rzburg. Every subject underwent an oto-rhino-laryngological examination as well as behavioral, electrophysiological and electroacoustical audiological testing. High-frequency thresholds were evaluated by using a modified PTA\(_{6}\) (0.5, 1, 2, 4, 6, 8) and HF-PTA (6, 8 kHz). Renal function was measured by eGFR, cardiac impairment was graduated by NYHA class. Results Sensorineural hearing loss was detected in 58.8\% of the cohort, which occurred typically in sudden episodes and affected especially high frequencies. Hearing loss is asymmetric, beginning unilaterally and affecting the contralateral ear later. Tinnitus was reported by 41.2\%. Renal and cardiac impairment influenced the severity of hearing loss (p < 0.05). Conclusions High frequency hearing loss is a common problem in patients with FD. Although not life-threatening, it can seriously reduce quality of life and should be taken into account in diagnosis and therapy. Optimized extensive hearing assessment including higher frequency thresholds should be used.}, language = {en} } @article{HerrmannMuellerGraffKaulitzetal.2022, author = {Herrmann, David P. and M{\"u}ller-Graff, Franz-Tassilo and Kaulitz, Stefan and Cebulla, Mario and Kurz, Anja and Hagen, Rudolf and Neun, Tilmann and Rak, Kristen}, title = {Application of intentional facial nerve stimulation during cochlear implantation as an electrophysiological tool to estimate the intracochlear electrode position}, series = {Scientific Reports}, volume = {12}, journal = {Scientific Reports}, number = {1}, doi = {10.1038/s41598-022-17732-9}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300197}, year = {2022}, abstract = {This proof of concept describes the use of evoked electromyographic (EMG) activation of the facial nerve for intraoperative monitoring of the electrode insertion during cochlear implantation (CI). Intraoperative EMG measurements from the facial nerve were conducted in nine patients undergoing CI implantation. Electric current pulses were emitted from contacts on the CI array during and immediately after electrode insertion. For control, the results of EMG measurements were compared to postoperative flat panel volume computed tomography scans with secondary reconstruction (fpVCT\(_{SECO}\)). During insertion, the EMG response evoked by the electrical stimulation from the CI was growing with the stimulating contact approaching the facial nerve and declined with increasing distance. After full insertion, contacts on the apical half of the CI array stimulated higher EMG responses compared with those on the basal half. Comparison with postoperative imaging demonstrated that electrode contacts stimulating high EMG responses had the shortest distances to the facial nerve. It could be demonstrated that electrically evoked EMG activation of the facial nerve can be used to monitor the progress during CI electrode insertion and to control the intracochlear electrode position after full insertion.}, language = {en} }