@article{UrlaubKaiserScherf‐Claveletal.2021, author = {Urlaub, Jonas and Kaiser, Reinhard P. and Scherf-Clavel, Oliver and Bolm, Carsten and Holzgrabe, Ulrike}, title = {Investigation of isomerization of dexibuprofen in a ball mill using chiral capillary electrophoresis}, series = {Electrophoresis}, volume = {42}, journal = {Electrophoresis}, number = {17-18}, doi = {10.1002/elps.202000307}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-225852}, pages = {1790 -- 1799}, year = {2021}, abstract = {Besides the racemate, the S-enantiomer of ibuprofen (Ibu) is used for the treatment of inflammation and pain. Since the configurational stability of S-Ibu in solid state is of interest, it was studied by means of ball milling experiments. For the evaluation of the enantiomeric composition, a chiral CE method was developed and validated according to the ICH guideline Q2(R1). The addition of Mg\(^{2+}\), Ca\(^{2+}\), or Zn\(^{2+}\) ions to the background electrolyte (BGE) was found to improve Ibu enantioresolution. Chiral separation of Ibu enantiomers was achieved on a 60.2 cm (50.0 cm effective length) x 75 μm fused-silica capillary using a background electrolyte (BGE) composed of 50 mM sodium acetate, 10 mM magnesium acetate tetrahydrate, and 35 mM heptakis-(2,3,6-tri-O-methyl)-β-cyclodextrin (TM-β-CD) as chiral selector. The quantification of R-Ibu in the mixture was performed using the normalization procedure. Linearity was evaluated in the range of 0.68-5.49\% R-Ibu (R\(^{2}\) = 0.999), recovery was found to range between 97 and 103\%, the RSD of intra- and interday precision below 2.5\%, and the limit of quantification for R- in S-Ibu was calculated to be 0.21\% (extrapolated) and 0.15\% (dilution of racemic ibuprofen), respectively. Isomerization of S-Ibu was observed under basic conditions by applying long milling times and high milling frequencies.}, language = {en} } @phdthesis{Urlaub2021, author = {Urlaub, Jonas}, title = {Development of analytical methods for the quality assessment of mineral oil based excipients and mechanochemically stressed active pharmaceutical ingredients}, doi = {10.25972/OPUS-24346}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-243465}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2021}, abstract = {For the quality assurance of substances for pharmaceutical use, a variety of analytical techniques are available to address specific analytical problems. In this field of application, liquid chromatography (LC) stands out as the gold standard in the pharmaceutical industry. Various detectors can be employed, which are e.g. based on UV/Vis spectroscopy for the examination of molecules with a chromophore, or mass spectrometry (MS) for structural elucidation of analytes. For the separation of enantiomers, the use of capillary electrophoresis (CE) may be more favorable due to the high separation efficiency and easy-to-use and comparatively inexpensive chiral selectors, in contrast to chiral columns for LC, which are usually very expensive and limited to a restricted number of analytes. For structure elucidation in impurity profiling, one- and multidimensional 1H NMR spectroscopy is a valuable tool as long as the analyte molecule has got nuclei that can be detected, which applies for the magnitude of organic pharmaceutical substances. For the evaluation of the amount of mineral oil aromatic hydrocarbons (MOAH) in various paraffin samples from different suppliers, a straightforward method based on 1H NMR spectroscopy was elaborated. The MOAH/MOSH ratio was used to indicate the amount of MOAH of paraffins and to evaluate the extent of refining. In addition, a representative paraffin sample was measured without sample solvent at high temperatures (about 340 K) to avoid the interfering residual solvent signals in the spectral regions of interest. The results of both methods were in good accordance. Moreover, the 1H NMR results were complemented with the UV measurements from the purity testing of paraffins according to the DAB 8. Correlations of the NMR and UV spectroscopic data indicated a linear relationship of both methods for the determination of MOAH in paraffins. Finally, the 1H NMR data was evaluated by principal component analysis (PCA) to explore differences within the paraffin samples and the spectral regions in the 1H NMR spectrum which are responsible for the formation of groups. It could be found that most variation is due to the MOSH of the paraffins. The PCA model was capable of differentiating between soft, liquid and solid paraffins on the one hand and between natural and synthetic liquid paraffins on the other hand. The impurity profiling of L-ascorbic acid 2-phosphate magnesium (A2PMg) was performed by means of one- and two-dimensional NMR spectroscopy. Several ethylated impurities could be detected, which were likely to be formed during synthesis of A2PMg. The structures of two of the ethylated impurities were identified as ascorbic acid 2-phosphate ethyl ester and ethanol, (residual solvent from synthesis). NMR spectroscopic studies of the fractions obtained from preparative HPLC of A2PMg revealed two additional impurities, which were identified as phosphorylated derivatives of ascorbic acid, ascorbic acid 3,5-phosphate and ascorbic acid 5-phosphate. Solid state mechanochemistry as an alternative approach for stress testing was applied on the drug substances S-Ibuprofen (Ibu) and Clopidogrel (CLP) using a ball mill, in order to study their degradation profile: First, the isomerization of S-Ibu was investigated, which was stressed in the solid state applying several milling frequencies and durations under basic, acidic and neutral conditions. For the separation of Ibu enantiomers, a chiral CE method was developed and validated according to ICH Q2(R1). It was found that S-Ibu is overall very stable to isomerization; it shows minor conversion into the R-enantiomer under basic environment applying long milling times and high frequencies. Last, the degradation profile of clopidogrel hydrogen sulfate (CLP) was investigated, which was stressed in the solid state under various oxidative conditions. An already existing HPLC-UV method was adjusted to sufficiently separate the degradation products, which were characterized by means of UV and MS/(MS) detection. Most of the degradation products identified were already reported to result from conventional CLP stress tests. The degradation profile of CLP was mainly influenced by the material of the milling jar and the type of catalyst used.}, subject = {HPLC}, language = {en} }