@article{SchuhmannKraftBieberetal.2019, author = {Schuhmann, Michael K. and Kraft, Peter and Bieber, Michael and Kollikowski, Alexander M. and Schulze, Harald and Nieswandt, Bernhard and Pham, Mirko and Stegner, David and Stoll, Guido}, title = {Targeting platelet GPVI plus rt-PA administration but not α2β1-mediated collagen binding protects against ischemic brain damage in mice}, series = {International Journal of Molecular Science}, volume = {20}, journal = {International Journal of Molecular Science}, number = {8}, issn = {1422-0067}, doi = {10.3390/ijms20082019}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-201700}, year = {2019}, abstract = {Platelet collagen interactions at sites of vascular injuries predominantly involve glycoprotein VI (GPVI) and the integrin α2β1. Both proteins are primarily expressed on platelets and megakaryocytes whereas GPVI expression is also shown on endothelial and integrin α2β1 expression on epithelial cells. We recently showed that depletion of GPVI improves stroke outcome without increasing the risk of cerebral hemorrhage. Genetic variants associated with higher platelet surface integrin α2 (ITGA2) receptor levels have frequently been found to correlate with an increased risk of ischemic stroke in patients. However until now, no preclinical stroke study has addressed whether platelet integrin α2β1 contributes to the pathophysiology of ischemia/reperfusion (I/R) injury. Focal cerebral ischemia was induced in C57BL/6 and Itga2\(^{-/-}\) mice by a 60 min transient middle cerebral artery occlusion (tMCAO). Additionally, wild-type animals were pretreated with anti-GPVI antibody (JAQ1) or Fab fragments of a function blocking antibody against integrin α2β1 (LEN/B). In anti-GPVI treated animals, intravenous (IV) recombinant tissue plasminogen activator (rt-PA) treatment was applied immediately prior to reperfusion. Stroke outcome, including infarct size and neurological scoring was determined on day 1 after tMCAO. We demonstrate that targeting the integrin α2β1 (pharmacologic; genetic) did neither reduce stroke size nor improve functional outcome on day 1 after tMCAO. In contrast, depletion of platelet GPVI prior to stroke was safe and effective, even when combined with rt-PA treatment. Our results underscore that GPVI, but not ITGA2, is a promising and safe target in the setting of ischemic stroke.}, language = {en} } @article{ElhfnawyHeuschmannPhametal.2019, author = {Elhfnawy, Ahmed Mohamed and Heuschmann, Peter U. and Pham, Mirko and Volkmann, Jens and Fluri, Felix}, title = {Stenosis length and degree interact with the risk of cerebrovascular events related to internal carotid artery stenosis}, series = {Frontiers in Neurology}, volume = {10}, journal = {Frontiers in Neurology}, number = {317}, issn = {1664-2295}, doi = {10.3389/fneur.2019.00317}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-196225}, year = {2019}, abstract = {Background and Purpose: Internal carotid artery stenosis (ICAS)≥70\% is a leading cause of ischemic cerebrovascular events (ICVEs). However, a considerable percentage of stroke survivors with symptomatic ICAS (sICAS) have <70\% stenosis with a vulnerable plaque. Whether the length of ICAS is associated with high risk of ICVEs is poorly investigated. Our main aim was to investigate the relation between the length of ICAS and the development of ICVEs. Methods: In a retrospective cross-sectional study, we identified 95 arteries with sICAS and another 64 with asymptomatic internal carotid artery stenosis (aICAS) among 121 patients with ICVEs. The degree and length of ICAS as well as plaque echolucency were assessed on ultrasound scans. Results: A statistically significant inverse correlation between the ultrasound-measured length and degree of ICAS was detected for sICAS≥70\% (Spearman correlation coefficient ρ = -0.57, p < 0.001, n = 51) but neither for sICAS<70\% (ρ = 0.15, p = 0.45, n = 27) nor for aICAS (ρ = 0.07, p = 0.64, n = 54). The median (IQR) length for sICAS<70\% and ≥70\% was 17 (15-20) and 15 (12-19) mm (p = 0.06), respectively, while that for sICAS<90\% and sICAS 90\% was 18 (15-21) and 13 (10-16) mm, respectively (p < 0.001). Among patients with ICAS <70\%, a cut-off length of ≥16 mm was found for sICAS rather than aICAS with a sensitivity and specificity of 74.1\% and 51.1\%, respectively. Irrespective of the stenotic degree, plaques of the sICAS compared to aICAS were significantly more often echolucent (43.2 vs. 24.6\%, p = 0.02). Conclusion: We found a statistically insignificant tendency for the ultrasound-measured length of sICAS<70\% to be longer than that of sICAS≥70\%. Moreover, the ultrasound-measured length of sICAS<90\% was significantly longer than that of sICAS 90\%. Among patients with sICAS≥70\%, the degree and length of stenosis were inversely correlated. Larger studies are needed before a clinical implication can be drawn from these results.}, language = {en} }