@phdthesis{Wagner2008, author = {Wagner, Silvia}, title = {Identifizierung von Biomarkern mittels LC-MS-basiertem Metabonomics - Merkapturs{\"a}uren als Indikatoren f{\"u}r die Bildung toxischer Intermediate}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-35760}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2008}, abstract = {Metabonomics bildet das Ende der Omics-Kaskade und stellt eine top-down-Strategie zur Erfassung und Interpretation des Metaboloms, d. h. der Gesamtheit aller niedermolekularen Metaboliten in einem intakten Organismus, dar. Ziel der Technik ist es, mittels geeigneter ungerichteter Screeningverfahren in nicht-invasiv zu gewinnenden biologischen Proben wie Urin oder Blut charakteristische Metabolitenprofile zu bestimmen. Im Kontext des Metabonomics wurde in Anlehnung an den Geno- bzw. Ph{\"a}notyp hierf{\"u}r der Begriff „Metabotyp" gepr{\"a}gt. Durch biostatistische Methoden, die auf Mustererkennung (pattern recognition) basieren, k{\"o}nnen Signaturen gegen{\"u}bergestellt und auf diesem Weg gruppenspezifische Metaboliten, d. h. Biomarker bzw. Metabolitenmuster, extrahiert werden. Metabonomics kann folglich als Fusion klassischer bioanalytischer und biostatistischer Verfahren aufgefasst werden. Seit der Einf{\"u}hrung im Jahr 1999 hat sich das Konzept des Metabonomics in mehrere Richtungen weiterentwickelt. So gab es Bestrebungen, die Technik, die urspr{\"u}nglich zur Pr{\"a}diktion von toxischen Effekten bei der Arzneistoffentwicklung etabliert wurde, auf Fragestellungen zu {\"u}bertragen, die den Menschen im Mittelpunkt haben. Neben pr{\"a}klinischen Anwendungen verfolgt man mit Metabonomics zunehmend das Ziel, einer personalisierten Medizin und Ern{\"a}hrung einen Schritt n{\"a}her zu kommen. Da sich die urspr{\"u}nglich eingesetzte NMR-Technik als zu unempfindlich und die resultierenden Metabolitenprofile als zu anf{\"a}llig gegen{\"u}ber biologischen und analytischen Einflussgr{\"o}ßen (Confoundern) erwiesen haben, wurde parallel auf sensitivere Verfahren wie die Massenspektrometrie gesetzt. Insbesondere die Kopplung mit der Hochdruckfl{\"u}ssigchromatographie erwies sich hierbei f{\"u}r das Metabolitenscreening als geeignet. Schnell wurde allerdings klar, dass aus den klassischen full scan/TOF-Methoden Datens{\"a}tze resultierten, die h{\"a}ufig zu komplex waren, um mit nachgeschalteten chemometrischen Verfahren die „Spreu vom Weizen trennen" zu k{\"o}nnen. Da sich Metabolitendatenbanken bisher noch im Aufbau befinden, ist die Identifizierung der Marker mit zus{\"a}tzlichen Schwierigkeiten verbunden und bedarf aufw{\"a}ndiger analytischer Verfahren. Eine Strategie stellt daher die Beschr{\"a}nkung auf ein Metabolitensubset dar. Indem man sich auf Metabolitenklassen fokussiert, die einen Bezug zum untersuchten Mechanismus haben, k{\"o}nnen die Erfolgsaussichten bei der Identifizierung charakteristischer Biomarker deutlich erh{\"o}ht werden. Aufgrund zahlreicher exogener und endogener Faktoren (Arzneistoffe, Industriechemikalien, Nahrungsbestandteile, Tabakrauchbestandteile, Produkte der Lipidperoxidation etc.) ist der menschliche Organismus stets einer Vielzahl an elektrophilen Verbindungen ausgesetzt. Oxidative Sch{\"a}digungen an Strukturen wie der DNA, Proteinen und Lipiden werden mit einer Reihe von Krankheitsbildern in Zusammenhang gebracht, darunter Parkinson, Alzheimer, Krebs und Volkskrankheiten wie Arteriosklerose, Allergien und koronare Herzerkrankungen. Mit dem Glutathionsystem verf{\"u}gt der K{\"o}rper {\"u}ber einen wirksamen Detoxifizierungsmechanismus. Das Tripeptid Glutathion reagiert als Nukleophil mit den exogen oder endogen gebildeten elektrophilen Intermediaten. Endprodukte sind Merkapturs{\"a}uren (N-Acetyl-L-Cystein-Addukte) bzw. deren Sulfoxide, die in erster Linie mit dem Urin ausgeschieden werden. Folglich besteht zwischen diesen Merkapturs{\"a}urederivaten und der elektrophilen Belastung eines Organismus ein direkter Zusammenhang. Vor diesem Hintergrund war es das Ziel der Arbeit, einen nicht-invasiven Metabonomicsansatz zur Anwendung am Menschen zu entwickeln. Durch die Fokussierung des Metabolitenscreenings auf die Effekt-, Dosis- und Suszeptibilit{\"a}tsmarkerklasse der Merkapturs{\"a}uren sollten hierbei die Erfolgsaussichten im Hinblick auf die Identifizierung potentieller Biomarker f{\"u}r diverse toxikologische sowie medizinische Endpunkte erh{\"o}ht werden.}, subject = {Metabolom}, language = {de} } @phdthesis{Simon2006, author = {Simon, Karoline}, title = {Development and Evaluation of a Generic HPLC-Tandem MS Screening Method for the Detection of Potential Biomarkers for Reactive Intermediates}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-21916}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2006}, abstract = {Conjugation of reactive intermediates of drugs with proteins or DNA may result in toxic effects such as hepatotoxicity, agranulocytosis, allergies, tumors, etc. From 1975 to 1999, 2.9\% of drugs were withdrawn from the market due to such severe adverse drug reactions. Thus, formation of chemically reactive intermediates is a widely discussed problem in drug development processes. Early detection of potentially toxic compounds is required for drug discovery and drug development. Conjugation of such electrophilic compounds with glutathione (GSH) is one of the most important detoxifying reactions in vivo. Processing of these GSH-conjugates ultimately leads to the formation of renally cleared mercapturic acids, which may also be oxidized to sulfoxides. Thus, mercapturic acids may be generated and detected in vitro and non-invasively in vivo in urine to assess the reactivity of a compound in early stages of drug development processes. Therefore, the aim of this work was to develop and evaluate a HPLC-MS/MS screening method for simple and rapid detection and characterization of known and unknown mercapturic acids and application of the method to several different matrices. Based on the common constant neutral loss (CNL) of 129 Da of all mercapturic acids tested (in negative ion mode), a CNL survey scan was performed using a linear ion trap instrument and was combined with two enhanced product ion (EPI) scans with different collision energies to characterize the detected signals. The CNL resulted from the cleavage between the sulfur and the carbon atom in the N-acetyl-L-cysteine moiety. After optimization of the experimental parameters, the detection limits of the reference substances in rat urine ranged from 0.3 to 15.5 pmol on column (i.e. 20 ng/ml to 800 ng/ml). For in vitro evaluation of the method, the model compounds acetaminophen, diclofenac, bifonazole, clozapine, troglitazone, carbamazepine, and bisphenol A were screened for formation of reactive intermediates and, hence, detection of the corresponding mercapturic acids. To determine possible species- and tissue-specific toxicities, the model compounds were incubated with stimulated neutrophils and with liver microsomes from rats and humans. Species-specific differences were observed in incubations of acetaminophen and diclofenac with rat and human hepatic microsomes. Tissue-specific differences in biotransformation of the model compounds in incubations with human neutrophils and human liver microsomes were observed for diclofenac, carbamazepine, clozapine, and bifonazole. The developed HPLC-MS/MS method was also evaluated in vivo by analysis of rat and human urine. Drug-related mercapturic acids were detected in urine of rats orally treated with acetaminophen (20 mg/kg and 640 mg/kg b.w.) or diclofenac (10 mg/kg and 20 mg/kg b.w.). Human urine samples were analyzed before and after oral administration of a clinically used dose of 500 mg and 50 mg of acetaminophen. Besides detection of the mercapturic acid of N-acetylbenzoquinoneimine (AAP-MA), a second mercapturic acid with m/z 327 occurred dose-dependently in rat and human urine samples after administration of acetaminophen. Further investigations on identification of this metabolite using authentic compounds and comparing their MS/MS mass spectra demonstrated oxidation of AAP-MA to stereoisomeric sulfoxides in vivo. For diclofenac, a novel mercapturic acid with m/z 441 was detected in rat urine samples that was identical to a metabolite obtained in incubations with human neutrophils before. The in vivo formation of this diclofenac metabolite is described here for the first time. In addition, three endogenously formed mercapturic acids were detected and identified. In conclusion, the results of the in vitro and in vivo evaluation demonstrate the advantages of the rapid and generic HPLC-MS/MS screening method for the detection of mercapturic acids, that can be obtained with a minimum of sample preparation and a high throughput in diverse matrices.}, subject = {Acetylcysteinderivate}, language = {en} }