@article{WernerChenRoweetal.2018, author = {Werner, Rudolf A. and Chen, Xinyu and Rowe, Steven P. and Lapa, Constantin and Javadi, Mehrbod S. and Higuchi, Takahiro}, title = {Moving into the Next Era of PET Myocardial Perfusion Imaging - Introduction of Novel \(^{18}\)F-labeled Tracers}, series = {The International Journal of Cardiovascular Imaging}, journal = {The International Journal of Cardiovascular Imaging}, issn = {1569-5794}, doi = {10.1007/s10554-018-1469-z}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-169134}, year = {2018}, abstract = {The heart failure (HF) epidemic continues to rise with coronary artery disease (CAD) as one of its main causes. Novel concepts for risk stratification to guide the referring cardiologist towards revascularization procedures are of significant value. Myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) agents has demonstrated high accuracy for the detection of clinically relevant stenoses. With positron emission tomography (PET) becoming more widely available, mainly due to its diagnostic performance in oncology, perfusion imaging with that modality is more practical than in the past and overcomes existing limitations of SPECT MPI. Advantages of PET include more reliable quantification of absolute myocardial blood flow, the routine use of computed tomography for attenuation correction, a higher spatiotemporal resolution and a higher count sensitivity. Current PET radiotracers such as rubidium-82 (half-life, 76 sec), oxygen-15 water (2 min) or nitrogen-13 ammonia (10 min) are labeled with radionuclides with very short half-lives, necessitating that stress imaging is performed under pharmacological vasodilator stress instead of exercise testing. However, with the introduction of novel 18F-labeled MPI PET radiotracers (half-life, 110 min), the intrinsic advantages of PET can be combined with exercise testing. Additional advantages of those radiotracers include, but are not limited to: potentially improved cost-effectiveness due to the use of pre-existing delivery systems and superior imaging qualities, mainly due to the shortest positron range among available PET MPI probes. In the present review, widely used PET MPI radiotracers will be reviewed and potential novel 18F-labeled perfusion radiotracers will be discussed.}, subject = {Positronenemissionstomografie}, language = {en} } @article{WernerEisslerHayakawaetal.2018, author = {Werner, Rudolf A. and Eissler, Christoph and Hayakawa, Nobuyuki and Arias-Loza, Paula and Wakabayashi, Hiroshi and Javadi, Mehrbod S. and Chen, Xinyu and Shinaji, Tetsuya and Lapa, Constantin and Pelzer, Theo and Higuchi, Takahiro}, title = {Left Ventricular Diastolic Dysfunction in a Rat Model of Diabetic Cardiomyopathy using ECG-gated \(^{18}\)F-FDG PET}, series = {Scientific Reports}, volume = {8}, journal = {Scientific Reports}, number = {17631}, doi = {10.1038/s41598-018-35986-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-171765}, year = {2018}, abstract = {In diabetic cardiomyopathy, left ventricular (LV) diastolic dysfunction is one of the earliest signs of cardiac involvement prior to the definitive development of heart failure (HF). We aimed to explore the LV diastolic function using electrocardiography (ECG)-gated \(^{18}\)F-fluorodeoxyglucose positron emission tomography (\(^{18}\)F-FDG PET) imaging beyond the assessment of cardiac glucose utilization in a diabetic rat model. ECG-gated \(^{18}\)F-FDG PET imaging was performed in a rat model of type 2 diabetes (ZDF fa/fa) and ZL control rats at age of 13 weeks (n=6, respectively). Under hyperinsulinemic-euglycemic clamp to enhance cardiac activity, \(^{18}\)F-FDG was administered and subsequently, list-mode imaging using a dedicated small animal PET system with ECG signal recording was performed. List-mode data were sorted and reconstructed into tomographic images of 16 frames per cardiac cycle. Left ventricular functional parameters (systolic: LV ejection fraction (EF), heart rate (HR) vs. diastolic: peak filling rate (PFR)) were obtained using an automatic ventricular edge detection software. No significant difference in systolic function could be obtained (ZL controls vs. ZDF rats: LVEF, 62.5±4.2 vs. 59.4±4.5\%; HR: 331±35 vs. 309±24 bpm; n.s., respectively). On the contrary, ECG-gated PET imaging showed a mild but significant decrease of PFR in the diabetic rats (ZL controls vs. ZDF rats: 12.1±0.8 vs. 10.2±1 Enddiastolic Volume/sec, P<0.01). Investigating a diabetic rat model, ECG-gated \(^{18}\)F-FDG PET imaging detected LV diastolic dysfunction while systolic function was still preserved. This might open avenues for an early detection of HF onset in high-risk type 2 diabetes before cardiac symptoms become apparent.}, language = {en} } @article{Menke2019, author = {Menke, Andreas}, title = {Is the HPA axis as target for depression outdated, or is there a new hope?}, series = {Frontiers in Psychiatry}, volume = {10}, journal = {Frontiers in Psychiatry}, number = {101}, issn = {1664-0640}, doi = {10.3389/fpsyt.2019.00101}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-195780}, year = {2019}, abstract = {Major depressive disorder (MDD) is a very common stress-related mental disorder that carries a huge burden for affected patients and the society. It is associated with a high mortality that derives from suicidality and the development of serious medical conditions such as heart diseases, diabetes, and stroke. Although a range of effective antidepressants are available, more than 50\% of the patients do not respond to the first treatment they are prescribed and around 30\% fail to respond even after several treatment attempts. The heterogeneous condition of MDD, the lack of biomarkers matching patients with the right treatments and the situation that almost all available drugs are only targeting the serotonin, norepinephrine, or dopamine signaling, without regulating other potentially dysregulated systems may explain the insufficient treatment status. The hypothalamic-pituitary-adrenal (HPA) axis is one of these other systems, there is numerous and robust evidence that it is implicated in MDD and other stress-related conditions, but up to date there is no specific drug targeting HPA axis components that is approved and no test that is routinely used in the clinical setting identifying patients for such a specific treatment. Is there still hope after these many years for a breakthrough of agents targeting the HPA axis? This review will cover tests detecting altered HPA axis function and the specific treatment options such as glucocorticoid receptor (GR) antagonists, corticotropin-releasing hormone 1 (CRH1) receptor antagonists, tryptophan 2,3-dioxygenase (TDO) inhibitors and FK506 binding protein 5 (FKBP5) receptor antagonists.}, language = {en} } @article{LippertFassnachtRonchi2022, author = {Lippert, Juliane and Fassnacht, Martin and Ronchi, Cristina L.}, title = {The role of molecular profiling in adrenocortical carcinoma}, series = {Clinical Endocrinology}, volume = {97}, journal = {Clinical Endocrinology}, number = {4}, doi = {10.1111/cen.14629}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-258382}, pages = {460-472}, year = {2022}, abstract = {Adrenocortical carcinoma (ACC) is a rare, aggressive cancer with still partially unknown pathogenesis, heterogenous clinical behaviour and no effective treatment for advanced stages. Therefore, there is an urgent clinical unmet need for better prognostication strategies, innovative therapies and significant improvement of the management of the individual patients. In this review, we summarize available studies on molecular prognostic markers and markers predictive of response to standard therapies as well as newly proposed drug targets in sporadic ACC. We include in vitro studies and available clinical trials, focusing on alterations at the DNA, RNA and epigenetic levels. We also discuss the potential of biomarkers to be implemented in a clinical routine workflow for improved ACC patient care.}, language = {en} } @article{SolimandoKrebsBittrichetal.2022, author = {Solimando, Antonio Giovanni and Krebs, Markus and Bittrich, Max and Einsele, Hermann}, title = {The urgent need for precision medicine in cancer and its microenvironment: the paradigmatic case of multiple myeloma}, series = {Journal of Clinical Medicine}, volume = {11}, journal = {Journal of Clinical Medicine}, number = {18}, issn = {2077-0383}, doi = {10.3390/jcm11185461}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-288164}, year = {2022}, abstract = {No abstract available}, language = {en} } @article{FriedrichSchneiderBuerkleinetal.2023, author = {Friedrich, Maximilian U. and Schneider, Erich and Buerklein, Miriam and Taeger, Johannes and Hartig, Johannes and Volkmann, Jens and Peach, Robert and Zeller, Daniel}, title = {Smartphone video nystagmography using convolutional neural networks: ConVNG}, series = {Journal of Neurology}, volume = {270}, journal = {Journal of Neurology}, number = {5}, doi = {10.1007/s00415-022-11493-1}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324526}, pages = {2518-2530}, year = {2023}, abstract = {Background Eye movement abnormalities are commonplace in neurological disorders. However, unaided eye movement assessments lack granularity. Although videooculography (VOG) improves diagnostic accuracy, resource intensiveness precludes its broad use. To bridge this care gap, we here validate a framework for smartphone video-based nystagmography capitalizing on recent computer vision advances. Methods A convolutional neural network was fine-tuned for pupil tracking using > 550 annotated frames: ConVNG. In a cross-sectional approach, slow-phase velocity of optokinetic nystagmus was calculated in 10 subjects using ConVNG and VOG. Equivalence of accuracy and precision was assessed using the "two one-sample t-test" (TOST) and Bayesian interval-null approaches. ConVNG was systematically compared to OpenFace and MediaPipe as computer vision (CV) benchmarks for gaze estimation. Results ConVNG tracking accuracy reached 9-15\% of an average pupil diameter. In a fully independent clinical video dataset, ConVNG robustly detected pupil keypoints (median prediction confidence 0.85). SPV measurement accuracy was equivalent to VOG (TOST p < 0.017; Bayes factors (BF) > 24). ConVNG, but not MediaPipe, achieved equivalence to VOG in all SPV calculations. Median precision was 0.30°/s for ConVNG, 0.7°/s for MediaPipe and 0.12°/s for VOG. ConVNG precision was significantly higher than MediaPipe in vertical planes, but both algorithms' precision was inferior to VOG. Conclusions ConVNG enables offline smartphone video nystagmography with an accuracy comparable to VOG and significantly higher precision than MediaPipe, a benchmark computer vision application for gaze estimation. This serves as a blueprint for highly accessible tools with potential to accelerate progress toward precise and personalized Medicine.}, language = {en} }