@article{BaumbachHoertererOppeltetal.2022, author = {Baumbach, Sebastian Felix and H{\"o}rterer, Hubert and Oppelt, Sonja and Szeimies, Ulrike and Polzer, Hans and Walther, Markus}, title = {Do pre-operative radiologic assessment predict postoperative outcomes in patients with insertional Achilles tendinopathy?: a retrospective database study}, series = {Archives of Orthopaedic and Trauma Surgery}, volume = {142}, journal = {Archives of Orthopaedic and Trauma Surgery}, number = {11}, issn = {1434-3916}, doi = {10.1007/s00402-021-03897-x}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-307963}, pages = {3045-3052}, year = {2022}, abstract = {Introduction Diagnosis and treatment of insertional tendinopathy of the Achilles tendon (IAT) remains a challenge. The aim of this study was to assess the influence of pre-operative radiological pathologies on the patient-reported outcomes following open debridement of all pathologies for IAT. Materials and methods In this IRB-approved retrospective correlation and comparative study, patients with pre-operative imaging were identified from the authors' retrospective IAT database comprising of 118 patients. All were treated by a standardized surgical treatment strategy utilizing a midline, transachillary approach and debridement of all pathologies. A total of fifteen radiologic parameters were measured on radiographs (RX) and MRI. The patient-reported outcomes were assessed using the Victorian Institute of Sport Assessment-Achilles questionnaire (VISA-A-G) and the general health questionnaire SF-12 at a minimum follow-up of 12 months. The data are presented as mean ± SD (95\% CI). Results 88 patients (74.6\%) with an average age of 50 ± 12 (47-52) years were included. Radiographs were available in 68 patients and MRI in 53. The mean follow-up was 3.8 ± 1.9 (3.4-4.3) years. The overall VISA-A-G was 81 ± 22 (77-86), the SF-12 PCS 54 ± 7 (52-55), and the SF-12 MCS 52 ± 9 (50-54) points. None of the assessed radiological parameters had a significant influence on the patient-reported outcome following surgical treatment for IAT. Conclusion In this retrospective correlation study, no significant association was found between preoperative radiographic and MRI radiologic parameters for IAT and postoperative patient-reported outcomes (VISA-A-G and SF-12).}, language = {en} } @article{JordanHufnagelMcDonoghetal.2022, author = {Jordan, Martin C. and Hufnagel, Lukas and McDonogh, Miriam and Paul, Mila M. and Schmalzl, Jonas and Kupczyk, Eva and Jansen, Hendrik and Heilig, Philipp and Meffert, Rainer H. and Hoelscher-Doht, Stefanie}, title = {Surgical fixation of calcaneal beak fractures — biomechanical analysis of different osteosynthesis techniques}, series = {Frontiers in Bioengineering and Biotechnology}, volume = {10}, journal = {Frontiers in Bioengineering and Biotechnology}, issn = {2296-4185}, doi = {10.3389/fbioe.2022.896790}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-282792}, year = {2022}, abstract = {The calcaneal beak fracture is a rare avulsion fracture of the tuber calcanei characterized by a solid bony fragment at the Achilles tendon insertion. Treatment usually requires osteosynthesis. However, lack of biomechanical understanding of the ideal fixation technique persists. A beak fracture was simulated in synthetic bones and assigned to five different groups of fixation: A) 6.5-mm partial threaded cannulated screws, B) 4.0-mm partial threaded cannulated screws, C) 5.0-mm headless cannulated compression screws, D) 2.3-mm locking plate, and E) 2.8-mm locking plate. Different traction force levels were applied through an Achilles tendon surrogate in a material-testing machine on all stabilized synthetic bones. Outcome measures were peak-to-peak displacement, total displacement, plastic deformation, stiffness, visual-fracture-line displacement, and mode of implant failure. The 2.3- and 2.8-mm plating groups showed a high drop-out rate at 100 N tension force and failed under higher tension levels of 200 N. The fracture fixation using 4.0-mm partial threaded screws showed a significantly higher repair strength and was able to withhold cyclic loading up to 300 N. The lowest peak-to-peak displacement and the highest load-to-failure and stiffness were provided by fracture fixation using 6.5-mm partial threaded cannulated screws or 5.0-mm headless cannulated compression screws. As anticipated, large 6.5-mm screw diameters provide the best biomechanical fixation. Surprisingly, the 5.0-mm headless cannulated compression screws yield reliable stability despite the absent screw head and washer. When such large screws cannot be applied, 4.0-mm screws also allow reasonable fixation strength. Plate fixation should be implemented with precaution and in combination with a restrictive postoperative motion protocol. Finally, clinical cases about the surgical application and recovery are included.}, language = {en} }