@article{GilbertKleinWengetal.2017, author = {Gilbert, Fabian and Klein, Detlef and Weng, Andreas Max and K{\"o}stler, Herbert and Schmitz, Benedikt and Schmalzl, Jonas and B{\"o}hm, Dirk}, title = {Supraspinatus muscle elasticity measured with real time shear wave ultrasound elastography correlates with MRI spectroscopic measured amount of fatty degeneration}, series = {BMC Muscoskeletal Disorders}, volume = {18}, journal = {BMC Muscoskeletal Disorders}, number = {549}, doi = {10.1186/s12891-017-1911-8}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-159378}, year = {2017}, abstract = {Background: Fatty Degeneration (FD) of the rotator cuff muscles influences functional and anatomical outcome after rotator cuff repair. The MRI based estimation of fatty degeneration is the gold standard. There is some evidence that Ultrasound elastography (EUS) can detect local differences of tissue stiffness in muscles and tendons. Shear-wave elastography (SWE) was evaluated to determine the extent to which shear wave velocity was associated with measures of fatty degeneration. MRI-spectroscopic fat measurement was used as a reference to quantify the amount of fat in the muscle belly. Methods: Forty-two patients underwent SWE of the supraspinatus muscles at its thickest diameter. After ultrasound evaluation an MRI-spectroscopic fat measurement of the supraspinatus muscle was performed using the SPLASH-technique. A gel filled capsule was used to locate the measured area in the MRI. The values of shear wave velocity (SWV) measured with SWE and spectroscopic fat measurement were correlated statistically using Pearson's correlation test. Results: Correlation of the fat amount measured with MRI-spectroscopy and the SWV measured with SWE was ρ =0.82. Spectroscopic measured fat ratio of the supraspinatus muscle ranged from 0\% to 77.41\% and SWV from 1.59 m/s to 5.32 m/s. In 4 patients no sufficient SWE could be performed, these individuals showed a larger diameter of the overlying soft tissue. SWV measured with SWE showed a good correlation with MRI spectroscopic fat amount of the supraspinatus muscle. Conclusion: These preliminary data suggest that SWE may be a sufficient tool in detecting and estimating the amount of fatty degeneration in the supraspinatus muscle in real time. Large overlying soft tissue may be a limitation in performing sufficient EUS.}, language = {en} } @article{JobsVontheinKoenigetal.2020, author = {Jobs, Alexander and Vonthein, Reinhard and K{\"o}nig, Inke R. and Sch{\"a}fer, Jane and Nauck, Matthias and Haag, Svenja and Fichera, Carlo Federico and Stiermaier, Thomas and Ledwoch, Jakob and Schneider, Alisa and Valentova, Miroslava and von Haehling, Stephan and St{\"o}rk, Stefan and Westermann, Dirk and Lenz, Tobias and Arnold, Natalie and Edelmann, Frank and Seppelt, Philipp and Felix, Stephan and Lutz, Matthias and Hedwig, Felix and Borggrefe, Martin and Scherer, Clemens and Desch, Steffen and Thiele, Holger}, title = {Inferior vena cava ultrasound in acute decompensated heart failure: design rationale of the CAVA-ADHF-DZHK10 trial}, series = {ESC Heart Failure}, volume = {7}, journal = {ESC Heart Failure}, number = {3}, doi = {10.1002/ehf2.12598}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-212692}, pages = {973 -- 983}, year = {2020}, abstract = {Aims Treating patients with acute decompensated heart failure (ADHF) presenting with volume overload is a common task. However, optimal guidance of decongesting therapy and treatment targets are not well defined. The inferior vena cava (IVC) diameter and its collapsibility can be used to estimate right atrial pressure, which is a measure of right-sided haemodynamic congestion. The CAVA-ADHF-DZHK10 trial is designed to test the hypothesis that ultrasound assessment of the IVC in addition to clinical assessment improves decongestion as compared with clinical assessment alone. Methods and results CAVA-ADHF-DZHK10 is a randomized, controlled, patient-blinded, multicentre, parallel-group trial randomly assigning 388 patients with ADHF to either decongesting therapy guided by ultrasound assessment of the IVC in addition to clinical assessment or clinical assessment alone. IVC ultrasound will be performed daily between baseline and hospital discharge in all patients. However, ultrasound results will only be reported to treating physicians in the intervention group. Treatment target is relief of congestion-related signs and symptoms in both groups with the additional goal to reduce the IVC diameter ≤21 mm and increase IVC collapsibility >50\% in the intervention group. The primary endpoint is change in N-terminal pro-brain natriuretic peptide from baseline to hospital discharge. Secondary endpoints evaluate feasibility, efficacy of decongestion on other scales, and the impact of the intervention on clinical endpoints. Conclusions CAVA-ADHF-DZHK10 will investigate whether IVC ultrasound supplementing clinical assessment improves decongestion in patients admitted for ADHF.}, language = {en} } @phdthesis{Schmid2012, author = {Schmid, Benedikt}, title = {Relation between cerebral arterio-venous transit time and neuropsychological performance in patients with vascular dementia}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-71234}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2012}, abstract = {Dementia, or any form of degenerative cognitive decline, is one of the major problems in present, and even more will be in future medicine. With Alzheimer's disease (AD) being the most prevalent, Vascular Dementia is the second most entity of dementing processes in the elderly. As diagnostic criteria are still imprecise and in many cases do not embrace early stages of the disease, recent studies have proposed more detailed classifications of the newly created condition Vascular Cognitive Impairment (VCI). Of all conditions subsumed under this term, subcortical small-vessel alterations are the most common cause for cognitive decline. The diagnosis of dementia / cognitive impairment is presently often made in late stages of the disease, when therapeutical options are poor. Thus, early detection of changes of the subcortical small vessels is desirable, when there is still time to identify and aggressively treat risk factors and underlying conditions like diabetes, hyper- or hypotension, and hyperlipidemia. This study aimed to evaluate whether cTT correlates to cognitive dysfunction, i.e. if cTT is fit as an early diagnostic tool for VCI. The study cohort included 38 patients from the Neurological Clinic of the W{\"u}rzburg University hospital admitted due to diagnoses other than dementia or stroke. As a result of this study it turned out that cTT is certainly capable of fulfilling the task to easily and effectively detect and evaluate possible microvascular lesions of the brain with respect to the actual clinical relevance for the patient. When compared to the other proposed diagnostic tools, neuropsychological testing and MRI, the advantages of cTT are obvious: its measurement is a low-cost and quick procedure which would spare both patients and examiners a long neuropsychological exam or complement it. cTT is safe to assess as the only possible risks derive from the use of the contrast agent, which are rare and easily manageable. It has also proven to be more accurate in showing the extent of cognitive impairment than MRI. Finally, it is widely available. The only prerequisite is an ultrasound machine capable of transcranial color-coded duplex sonography. No cost-intensive procedures like MRI are needed. So, with neuropsychological testing remaining the gold standard, cTT here proved to be a reliable alternative which is more time- and cost-effective than MRI.}, subject = {Demenz}, language = {en} } @article{SteinWollschlaegerKreienbergetal.2016, author = {Stein, Roland Gregor and Wollschl{\"a}ger, Daniel and Kreienberg, Rolf and Janni, Wolfgang and Wischnewsky, Manfred and Diessner, Joachim and St{\"u}ber, Tanja and Bartmann, Catharina and Krockenberger, Mathias and Wischhusen, J{\"o}rg and W{\"o}ckel, Achim and Blettner, Maria and Schwentner, Lukas}, title = {The impact of breast cancer biological subtyping on tumor size assessment by ultrasound and mammography - a retrospective multicenter cohort study of 6543 primary breast cancer patients}, series = {BMC Cancer}, volume = {16}, journal = {BMC Cancer}, number = {549}, doi = {10.1186/s12885-016-2426-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-161050}, year = {2016}, abstract = {Background Mammography and ultrasound are the gold standard imaging techniques for preoperative assessment and for monitoring the efficacy of neoadjuvant chemotherapy in breast cancer. Maximum accuracy in predicting pathological tumor size non-invasively is critical for individualized therapy and surgical planning. We therefore aimed to assess the accuracy of tumor size measurement by ultrasound and mammography in a multicentered health services research study. Methods We retrospectively analyzed data from 6543 patients with unifocal, unilateral primary breast cancer. The maximum tumor diameter was measured by ultrasound and/or mammographic imaging. All measurements were compared to final tumor diameter determined by postoperative histopathological examination. We compared the precision of each imaging method across different patient subgroups as well as the method-specific accuracy in each patient subgroup. Results Overall, the correlation with histology was 0.61 for mammography and 0.60 for ultrasound. Both correlations were higher in pT2 cancers than in pT1 and pT3. Ultrasound as well as mammography revealed a significantly higher correlation with histology in invasive ductal compared to lobular cancers (p < 0.01). For invasive lobular cancers, the mammography showed better correlation with histology than ultrasound (p = 0.01), whereas there was no such advantage for invasive ductal cancers. Ultrasound was significantly superior for HR negative cancers (p < 0.001). HER2/neu positive cancers were also more precisely assessed by ultrasound (p < 0.001). The size of HER2/neu negative cancers could be more accurately predicted by mammography (p < 0.001). Conclusion This multicentered health services research approach demonstrates that predicting tumor size by mammography and ultrasound provides accurate results. Biological tumor features do, however, affect the diagnostic precision.}, language = {en} }