@phdthesis{JakobRodamer2014, author = {Jakob-Rodamer, Verena}, title = {Development and validation of LC-MS/MS methods to determine PK/PD parameters of anti-infectives}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-109215}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2014}, abstract = {In the present thesis the development and validation of bioanalytical LC-MS/MS methods for the quantification of erythromycin A, erythromycin ethylsuccinate, roxithromycin, clarithromycin, 14 hydroxy clarithromycin, flucloxacillin, piperacillin and moxifloxacin in human plasma and human urine (piperacillin) is introduced. All methods were applied to analyze human plasma and urine samples from clinical trials and therefore, have been validated according to international guidelines. The methods were reliable in these studies and fulfilled all regulatory requirements known at the time of the study conduct. Moreover, the validation data of the macrolides were compared on three different mass spectrometers (API III Plus, API 3000™, API 5000™). The new innovations in the ion source (horizontal versus vertical electrospray), the ionpath (skimmer, QJet) and the diameter of the orifice resulted in better sensitivity and a larger linearity range for the majority of the analytes. Sensitivity was improved up to a factor of 12 (for clarithromycin) between API III Plus to API 3000™ and up to a factor of 8 (for erythromycin and roxithromycin) between API 3000™ and API 5000™, keeping the accuracy and precision data at about the same level. The high sensitivity was a benefit for example for the flucloxacillin study, because concentrations from all subject samples were detectable up to approximately eight half-lives, i.e. no concentrations needed to be reported below the quantification limit. Also the linearity range were extended from two orders of magnitude to up to four orders of magnitude, which increases the likelihood to allow to analyze all samples from a pharmacokinetic study in the same run. This is especially useful if a large concentration range needs to be analysed, for example, if the method shall be applied in an ascending dose study. Then, all low concentrations from the beginning of the study can be determined, as well as all high concentrations, without the need to dilute and analyse single samples repeatedly. The pharmacokinetic data were compared to previously reported literature data and correlated graphically with MIC values of popular microorganisms which might be a starting point for further PK/PD investigations. The PK/PD theory is a very helpful tool for prediction of the efficacy of given drugs against certain micro-organisms. Depending on the pharmacodynamic processes, e. g. the mode of action, three classes of drugs have been identified. In the same way this applies to adverse effects, which need to be minimised by reducing plasma concentrations. These coherences are not well-investigated, yet, and are not discussed further in this thesis. Still, a lot of research has to be done in this interdisciplinary field to minimise uncertainty in single values, like an AUC/MIC. These include: Improve accuracy and precision of bioanalytical methods determining total and free concentration data in biological matrices for calculation of AUC and Cmax These parameters are related to the MIC in pharmacodynamic considerations. Since the determination of the MIC often underlies significant variations and also differences between microbiological laboratories, the determination of concentrations of anti-infectives is particular important, being achievable by scientific exact techniques. Finally, from the volume of distribution of antibiotics can be used to derive information about intracellular concentrations and effectivity of antiinfectives.}, subject = {Antimikrobieller Wirkstoff}, language = {en} } @phdthesis{Urlaub2021, author = {Urlaub, Jonas}, title = {Development of analytical methods for the quality assessment of mineral oil based excipients and mechanochemically stressed active pharmaceutical ingredients}, doi = {10.25972/OPUS-24346}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-243465}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2021}, abstract = {For the quality assurance of substances for pharmaceutical use, a variety of analytical techniques are available to address specific analytical problems. In this field of application, liquid chromatography (LC) stands out as the gold standard in the pharmaceutical industry. Various detectors can be employed, which are e.g. based on UV/Vis spectroscopy for the examination of molecules with a chromophore, or mass spectrometry (MS) for structural elucidation of analytes. For the separation of enantiomers, the use of capillary electrophoresis (CE) may be more favorable due to the high separation efficiency and easy-to-use and comparatively inexpensive chiral selectors, in contrast to chiral columns for LC, which are usually very expensive and limited to a restricted number of analytes. For structure elucidation in impurity profiling, one- and multidimensional 1H NMR spectroscopy is a valuable tool as long as the analyte molecule has got nuclei that can be detected, which applies for the magnitude of organic pharmaceutical substances. For the evaluation of the amount of mineral oil aromatic hydrocarbons (MOAH) in various paraffin samples from different suppliers, a straightforward method based on 1H NMR spectroscopy was elaborated. The MOAH/MOSH ratio was used to indicate the amount of MOAH of paraffins and to evaluate the extent of refining. In addition, a representative paraffin sample was measured without sample solvent at high temperatures (about 340 K) to avoid the interfering residual solvent signals in the spectral regions of interest. The results of both methods were in good accordance. Moreover, the 1H NMR results were complemented with the UV measurements from the purity testing of paraffins according to the DAB 8. Correlations of the NMR and UV spectroscopic data indicated a linear relationship of both methods for the determination of MOAH in paraffins. Finally, the 1H NMR data was evaluated by principal component analysis (PCA) to explore differences within the paraffin samples and the spectral regions in the 1H NMR spectrum which are responsible for the formation of groups. It could be found that most variation is due to the MOSH of the paraffins. The PCA model was capable of differentiating between soft, liquid and solid paraffins on the one hand and between natural and synthetic liquid paraffins on the other hand. The impurity profiling of L-ascorbic acid 2-phosphate magnesium (A2PMg) was performed by means of one- and two-dimensional NMR spectroscopy. Several ethylated impurities could be detected, which were likely to be formed during synthesis of A2PMg. The structures of two of the ethylated impurities were identified as ascorbic acid 2-phosphate ethyl ester and ethanol, (residual solvent from synthesis). NMR spectroscopic studies of the fractions obtained from preparative HPLC of A2PMg revealed two additional impurities, which were identified as phosphorylated derivatives of ascorbic acid, ascorbic acid 3,5-phosphate and ascorbic acid 5-phosphate. Solid state mechanochemistry as an alternative approach for stress testing was applied on the drug substances S-Ibuprofen (Ibu) and Clopidogrel (CLP) using a ball mill, in order to study their degradation profile: First, the isomerization of S-Ibu was investigated, which was stressed in the solid state applying several milling frequencies and durations under basic, acidic and neutral conditions. For the separation of Ibu enantiomers, a chiral CE method was developed and validated according to ICH Q2(R1). It was found that S-Ibu is overall very stable to isomerization; it shows minor conversion into the R-enantiomer under basic environment applying long milling times and high frequencies. Last, the degradation profile of clopidogrel hydrogen sulfate (CLP) was investigated, which was stressed in the solid state under various oxidative conditions. An already existing HPLC-UV method was adjusted to sufficiently separate the degradation products, which were characterized by means of UV and MS/(MS) detection. Most of the degradation products identified were already reported to result from conventional CLP stress tests. The degradation profile of CLP was mainly influenced by the material of the milling jar and the type of catalyst used.}, subject = {HPLC}, language = {en} }