@article{SauerGoltzGassenmaieretal.2014, author = {Sauer, Stephanie and Goltz, Jan P. and Gassenmaier, Tobias and Kunz, Andreas S. and Bley, Thorsten A. and Klein, Detlef and Petritsch, Bernhard}, title = {Partial Segmental Thrombosis of the Corpus Cavernosum (PSTCC) diagnosed by contrast-enhanced ultrasound: a case report}, series = {BMC Urology}, volume = {14}, journal = {BMC Urology}, number = {100}, doi = {10.1186/1471-2490-14-100}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-126495}, year = {2014}, abstract = {Background Partial segmental thrombosis of the corpus cavernosum (PSTCC) is a rare disease predominantly occurring in young men. Cardinal symptoms are pain and perineal swelling. Although several risk factors are described in the literature, the exact etiology of penile thrombosis remains unclear in most cases. MRI or ultrasound (US) is usually used for diagnosing this condition. Case presentation We report a case of penile thrombosis after left-sided varicocele ligature in a young patient. The diagnosis was established using contrast-enhanced ultrasound (CEUS) and was confirmed by contrast-enhanced magnetic resonance imaging (ceMRI). Successful conservative treatment consisted of systemic anticoagulation using low molecular weight heparin and acetylsalicylic acid. Conclusion PSTCC is a rare condition in young men and appears with massive pain and perineal swelling. In case of suspected PSTCC utilization of CEUS may be of diagnostic benefit.}, language = {en} } @article{SauerLiHollWiedenetal.2017, author = {Sauer, Alexander and Li, Mengxia and Holl-Wieden, Annette and Pabst, Thomas and Neubauer, Henning}, title = {Readout-segmented multi-shot diffusion-weighted MRI of the knee joint in patients with juvenile idiopathic arthritis}, series = {Pediatric Rheumatology}, volume = {15}, journal = {Pediatric Rheumatology}, number = {73}, doi = {10.1186/s12969-017-0203-z}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-158095}, year = {2017}, abstract = {Background: Diffusion-weighted MRI has been proposed as a new technique for imaging synovitis without intravenous contrast application. We investigated diagnostic utility of multi-shot readout-segmented diffusion-weighted MRI (multi-shot DWI) for synovial imaging of the knee joint in patients with juvenile idiopathic arthritis (JIA). Methods: Thirty-two consecutive patients with confirmed or suspected JIA (21 girls, median age 13 years) underwent routine 1.5 T MRI with contrast-enhanced T1w imaging (contrast-enhanced MRI) and with multi-shot DWI (RESOLVE, b-values 0-50 and 800 s/mm\(^2\)). Contrast-enhanced MRI, representing the diagnostic standard, and diffusion-weighted images at b = 800 s/mm\(^2\) were separately rated by three independent blinded readers at different levels of expertise for the presence and the degree of synovitis on a modified 5-item Likert scale along with the level of subjective diagnostic confidence. Results: Fourteen (44\%) patients had active synovitis and joint effusion, nine (28\%) patients showed mild synovial enhancement not qualifying for arthritis and another nine (28\%) patients had no synovial signal alterations on contrast-enhanced imaging. Ratings by the 1st reader on contrast-enhanced MRI and on DWI showed substantial agreement (κ = 0.74). Inter-observer-agreement was high for diagnosing, or ruling out, active arthritis of the knee joint on contrast-enhanced MRI and on DWI, showing full agreement between 1st and 2nd reader and disagreement in one case (3\%) between 1st and 3rd reader. In contrast, ratings in cases of absent vs. little synovial inflammation were markedly inconsistent on DWI. Diagnostic confidence was lower on DWI, compared to contrast-enhanced imaging. Conclusion: Multi-shot DWI of the knee joint is feasible in routine imaging and reliably diagnoses, or rules out, active arthritis of the knee joint in paediatric patients without the need of gadolinium-based i.v. contrast injection. Possibly due to "T2w shine-through" artifacts, DWI does not reliably differentiate non-inflamed joints from knee joints with mild synovial irritation.}, language = {en} } @phdthesis{Sahmer2007, author = {Sahmer, Peter}, title = {Scannereigene akustische Aktivierung - Eine neue Pulssequenz vereinfacht fMRT des auditiven Kortex}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-28083}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2007}, abstract = {Echo-planar Imaging (EPI) erzeugt durch schnell wechselnde Gradienten betr{\"a}chtliche Schallemissionen. Dies f{\"u}hrt nachgewiesenermaßen bei funktionellen Magnet-Resonanz-Tomographie- (fMRT-) Studien zu einer Aktivierung des auditiven Systems, insofern dieses beim jeweiligen Probanden in der Lage ist zu reagieren. Sowohl f{\"u}r auditive wie auch f{\"u}r nicht-auditive Untersuchungen wurden verschiedenste Anstrengungen unternommen, diese Interferenzen zu minimieren. Anstatt den L{\"a}rm des Scanners zu reduzieren oder die Transmission des Schalls zu behindern, war es nun das Ziel, eben diesen Schall zur Aktivierung des auditiven Kortex zu benutzen und diese mit fMRT-Untersuchungen nachzuweisen. Dieses geschieht schlicht durch das Auslassen von Read-Outs aus der Gradientenfolge der Pulssequenz. Diese Pulse sind die Hauptemissionsquellen von Schall des EPI, sie verursachen sowohl den Spitzenschallpegel als auch die Grundfrequenz, welche im umgekehrten Verh{\"a}ltnis zum Echo-Spacing steht. Durch eine Modell-gest{\"u}tzte Analyse wird gezeigt, dass das Auslassen von Read-Outs nach einem vordefinierten Schema verl{\"a}sslich dazu geeignet ist, eine h{\"a}modynamische Blood-Oxygenation-Level-Dependent- (BOLD-) Signalver{\"a}nderung im auditiven Kortex von normal h{\"o}renden Probanden (n=60) zu evozieren. Um den Nutzen der Technik beim auditiven fMRI zu zeigen, werden auf der Ebene der Einzelanalysen das traditionelle Family-Wise-Error-Rate- (FWER-) korrigierte Maximum Height Thresholding mit dem Spatial Mixture Modelling (SMM) verglichen. Mit Letzterem k{\"o}nnen so in 95 \% der F{\"a}lle eine ad{\"a}quate, bilaterale, auditive Aktivierung nachwiesen werden, wohingegen das FWER-basierte Voxel-Thresholding nur in 72 \% aller Probanden eine solche Aktivierung zeigt. Um die klinische Anwendbarkeit der Technik unter pathologischen Bedingungen zu demonstrieren, wird ein Fallbericht einer Patientin vorgestellt, die an einem schweren, beidseitigen Sensorineural Hearing Loss (SNHL) aufgrund bilateraler Large Vestibular Aqueducts (LVAs) leidet. Dabei wird eben diese Modifikation benutzt, um pr{\"a}operativ vor Cochlear Implantation (CI) zu zeigen, dass ein zentrales Resth{\"o}rverm{\"o}gen vorhanden ist. Da die Untersuchung v{\"o}llig unabh{\"a}ngig von der Compliance des Patienten und kein zus{\"a}tzliches Zubeh{\"o}r zum Scanner vonn{\"o}ten sind, eignet sie sich hervorragend zu auditiven Untersuchungen, um so schnell das H{\"o}rverm{\"o}gen zu pr{\"u}fen. Dabei funktioniert die Methode unabh{\"a}ngig von {\"a}ußerlichen Bedingungen: Bei h{\"o}rgesunden Probanden ebenso wie bei H{\"o}rgesch{\"a}digten, bei Kindern, Jugendlichen und Erwachsenen aller Altersstufen sowie unabh{\"a}ngig von einer Sedierung w{\"a}hrend der Untersuchung. Beide benutzten Scanner zeigten unabh{\"a}ngig vom Gradienten oder der verwendeten Spule ein gleiches Ergebnis.}, subject = {fMRT}, language = {de} } @phdthesis{Rueber2009, author = {R{\"u}ber, Matthias}, title = {Deterministische und probabilistische Traktographie mittels Diffusions Tensor Imaging unter aversiven Diffusionsbedingungen}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-39118}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2009}, abstract = {Die diffusionsgewichtete Magnetresonanztomographie (DW-MRT) ist ein fester Bestandteil der radiologischen Diagnostik des Zentralnervensystems (ZNS), und zwar nicht nur bei Schlaganf{\"a}llen sondern zunehmend auch bei Hirntumoren, Sch{\"a}delhirntraumata, demyelinisierenden, degenerativen sowie entz{\"u}ndlichen Erkrankungen. Diese Pathologien gehen in der Regel mit einer Ver{\"a}nderung der lokalen Diffusionsbedingungen einher, die eine regul{\"a}re Diffusionsbildgebung beeintr{\"a}chtigen. Durch die Bestimmung der Diffusionsparameter lassen sich mit Hilfe verschiedener mathematischer Verfahren Faserverbindungen visualisieren. Wie sich diese unterschiedlichen Methoden in Regionen mit aversiven Diffusionsbedingungen verhalten, konnte mit der Arbeit erstmals systematisch gezeigt werden. Hierzu wurden 29 Patientenuntersuchungen ausgewertet. Als Einschlusskriterium galt eine unilaterale, diffusionsrelevante L{\"a}sion mit Bezug zur Pyramidenbahn. Ausschlusskriterium war eine vollst{\"a}ndige Hemiparese als Zeichen einer vollst{\"a}ndigen Zerst{\"o}rung der relevanten Leitungsbahn. Im Einzelnen handelte es sich bei den untersuchten L{\"a}sionen um drei h{\"o}hergradige Astrozytome (WHO Grad III-IV), drei niedriggradige Astrozytome, acht Glioblastome, zwei Karzinommetastasen, zwei arterioven{\"o}se Malformationen und je eine entz{\"u}ndliche Parasitose, ein Oligodendrogliom, eine Gliomatose und ein Kavernom. Untersucht wurden zwei deterministische (einfaches und interpoliertes streamlining) und drei probabilistische Methoden (ohne crossing fibers; mit Berechnung von zwei Fasern pro Voxel und constrained/bayesian). L{\"a}sionen jeglicher Art verursachten signifikant mehr Fehlschl{\"a}ge bei deterministischer als bei probabilistischer Traktographie. In neun Untersuchungen bei einfacher und in acht Untersuchungen bei interpolierter Traktographie zeigten sich fasch negative Ergebnisse. Probabilistisches Traktographieren eliminiert nicht falsch negative Ergebnisse, reduziert sie jedoch unter den oben genannten aversiven Difussivit{\"a}tsbedingungen mit denen intraaxiale L{\"a}sionen einhergehen. Klinisches Wissen {\"u}ber die verbliebene Traktintegrit{\"a}t erm{\"o}glicht die Umwandlung der Traktographieergebnisse in Wahrscheinlichkeitswerte innerhalb eines Bayschen Modells. Außerdem ist nur unter Miteinbeziehung klinischer Informationen eine Traktographie nach dem constrained Modell m{\"o}glich. Obwohl die probabilistische Traktographie weniger anf{\"a}llig f{\"u}r falsch negative Ergebnisse ist als die deterministische, geht die erh{\"o}hte Sensitivit{\"a}t der Algorithmen auf Kosten der Spezifit{\"a}t. Dies zeigt sich in signifikant erh{\"o}hten bilateralen Traktvolumina und einem {\"u}berm{\"a}ßigen Unterschied der Traktvolumina von L{\"a}sionsseite zu kontralateraler Seite. Die probabilistisch, unconstrained durchgef{\"u}hrte Traktographie der Pyramidenbahn zeigte eine signifikant, durch die L{\"a}sion verursachte Volumenminderung des Traktes, w{\"a}hrend dies im constrained modellierten Fall durch die Daten nicht gezeigt werden konnte. Dies zeigt die Robustheit des Constrained Modells unter den aversiven klinischen Bedingungen einer intraaxialen L{\"a}sion ohne den Nachteil von erh{\"o}hten Fehltraktographien. Es kann konstatiert werden, dass sich die deterministischen Traktographieverfahren zur pr{\"a}operativen Orientierung vor neurochirurgischen Eingriffen eignen. Jedoch ist eine nicht zu untersch{\"a}tzende Anzahl von falsch negativen Ergebnissen zu ber{\"u}cksichtigen. In zweifelhaften F{\"a}llen sollte zus{\"a}tzlich eine Darstellung mittels probabilistischen Algorithmen, am besten mittels Constrained Modell durchgef{\"u}hrt werden.}, subject = {NMR-Tomographie}, language = {de} } @phdthesis{RungeHiemer2015, author = {Runge-Hiemer, Pamela}, title = {Elastographie (qualitativ und semiquantitativ) am Hals bei Kindern und Jugendlichen}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-135048}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {In unserer Studie kamen die neuen Verfahren qualitative und semiquantitative Elastographie zum Einsatz. Es sollte gezeigt werden, ob sie als Erg{\"a}nzung zu den herk{\"o}mmlichen sonographischen Verfahren die Diagnosestellung von Erkrankungen am Hals bei Kindern und Jugendlichen verbessern k{\"o}nnen. Bei der Untersuchung mittels semiquantitativer Elastographie konnten wir in unserer Studie beim Vergleich Schilddr{\"u}sen-Normalbefund und Hashimoto-Thyreoiditis einen signifikanten Unterschied der Scherwellengeschwindigkeiten nachweisen. Es zeigte sich, dass Patienten mit Hashimoto-Thyreoiditis signifikant h{\"o}here Scherwellengeschwindigkeiten aufweisen als Patienten mit Normalbefund. F{\"u}r die anderen untersuchten Schilddr{\"u}senerkrankungen, Struma diffusa und Struma nodosa und f{\"u}r die Erkrankungen der Lymphknoten, benigne Ver{\"a}nderung/Entz{\"u}ndung, maligne Ver{\"a}nderung und Abszess, ließ sich kein signifikanter Unterschied feststellen. Die Sensitivit{\"a}t und Spezifit{\"a}t konnte durch Einsatz des neuen Verfahrens der qualitativen Elastographie nicht gesteigert werden. W{\"a}hrend sich bei der Schilddr{\"u}sendiagnostik geringere Werte f{\"u}r Sensitivit{\"a}t und Spezifit{\"a}t im Vergleich zu den herk{\"o}mmlichen Verfahren zeigten, unterschieden sich die Werte bei der Lymphknotenuntersuchung Reader-abh{\"a}ngig. Bei der Schilddr{\"u}senuntersuchung lag die Bildqualit{\"a}t der konventionellen Sonographie {\"u}ber der der qualitativen Elastographie. Dagegen wurde bei der Lymphknotenuntersuchung die Bildqualit{\"a}t der Elastographiebilder h{\"o}her bewertet als jene der herk{\"o}mmlichen Verfahren. Insgesamt konnte in unserer Studie gezeigt werden, dass Patienten mit Hashimoto-Thyreoiditits signifikant h{\"o}here Scherwellengeschwindigkeiten im Schilddr{\"u}sengewebe aufweisen, als bei Normalbefund. In der Diagnostik von Schilddr{\"u}sen- und Lymphknotenerkrankungen konnte bez{\"u}glich des neuen Verfahrens der qualitativen Elastographie eine {\"U}berlegenheit gegen{\"u}ber der konventionellen Sonographie nicht nachgewiesen werden. Um die Ergebnisse unserer Studie abschließend bewerten zu k{\"o}nnen, w{\"a}re eine Validierung anhand einer gr{\"o}ßeren Patientengruppe n{\"o}tig.}, subject = {Elastographie}, language = {de} } @article{RufBeerKoestleretal.2019, author = {Ruf, Katharina and Beer, Meinrad and K{\"o}stler, Herbert and Weng, Andreas Max and Neubauer, Henning and Klein, Alexander and Platek, Kathleen and Roth, Kristina and Beneke, Ralph and Hebestreit, Helge}, title = {Size-adjusted muscle power and muscle metabolism in patients with cystic fibrosis are equal to healthy controls - a case control study}, series = {BMC Pulmonary Medicine}, volume = {19}, journal = {BMC Pulmonary Medicine}, doi = {10.1186/s12890-019-1039-8}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-200981}, pages = {269}, year = {2019}, abstract = {Background Skeletal muscle function dysfunction has been reported in patients with cystic fibrosis (CF). Studies so far showed inconclusive data whether reduced exercise capacity is related to intrinsic muscle dysfunction in CF. Methods Twenty patients with CF and 23 age-matched controls completed an incremental cardiopulmonary cycling test. Further, a Wingate anaerobic test to assess muscle power was performed. In addition, all participants completed an incremental knee-extension test with 31P magnetic resonance spectroscopy to assess muscle metabolism (inorganic phosphate (Pi) and phosphocreatinine (PCr) as well as intracellular pH). In the MRI, muscle cross-sectional area of the M. quadriceps (qCSA) was also measured. A subgroup of 15 participants (5 CF, 10 control) additionally completed a continuous high-intensity, high-frequency knee-extension exercise task during 31P magnetic resonance spectroscopy to assess muscle metabolism. Results Patients with CF showed a reduced exercise capacity in the incremental cardiopulmonary cycling test (VO2peak: CF 77.8 ± 16.2\%predicted (36.5 ± 7.4 ml/qCSA/min), control 100.6 ± 18.8\%predicted (49.1 ± 11.4 ml/qCSA/min); p < 0.001), and deficits in anaerobic capacity reflected by the Wingate test (peak power: CF 537 ± 180 W, control 727 ± 186 W; mean power: CF 378 ± 127 W, control 486 ± 126 W; power drop CF 12 ± 5 W, control 8 ± 4 W. all: p < 0.001). In the knee-extension task, patients with CF achieved a significantly lower workload (p < 0.05). However, in a linear model analysing maximal work load of the incremental knee-extension task and results of the Wingate test, respectively, only muscle size and height, but not disease status (CF or not) contributed to explaining variance. In line with this finding, no differences were found in muscle metabolism reflected by intracellular pH and the ratio of Pi/PCr at submaximal stages and peak exercise measured through MRI spectroscopy. Conclusions The lower absolute muscle power in patients with CF compared to controls is exclusively explained by the reduced muscle size in this study. No evidence was found for an intrinsic skeletal muscle dysfunction due to primary alterations of muscle metabolism.}, language = {en} } @phdthesis{Robrecht2007, author = {Robrecht, Julia}, title = {Diagnostik des Vesikoureteralen Reflux : In-vitro-Vergleich eines Ultraschallkontrastmittels der 1. mit einem der 2. Generation}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-22418}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2007}, abstract = {ZIEL: In den letzten Jahren ist die kontrastverst{\"a}rkte sonographische Refluxpr{\"u}fung, d.h. die Miktionsurosonographie (MUS), zunehmend zu einer Alternative gegen{\"u}ber der standardm{\"a}ßig eingesetzten Miktions-zysturethrographie (MCU) f{\"u}r die Diagnostik des vesikoureteralen Reflux (VUR) geworden. Eine der Einschr{\"a}nkungen sind jedoch die sehr hohen Kosten des Ultraschallkontrastmittels. Durch Entwicklung von neuen Ultraschallkontrastmitteln erhofft man sich aufgrund vergleichbarer Bildqualit{\"a}t in deutlich niedrigerer Dosis entsprechend eine Reduktion der Kosten zu erreichen. Thema dieser Studie ist eines dieser neuen Ultraschallkontrastmittel (SonoVue®) mit dem in der Routine verwendeten US-Kontrastmittel Levovist® in-vitro unter Betrachtung der f{\"u}r die Refluxdiagnostik relevanten physikalisch-chemischen Eigenschaften zu vergleichen. MATERIAL UND METHODEN: Der in-vitro Versuchsaufbau simulierte die in-vivo durchgef{\"u}hrte MUS. Verwendet wurden die Abbildungsmodalit{\"a}ten Fundamental und Harmonic Imaging (THI/ECI, Sonoline Elegra®, Siemens), letztere sowohl mit einem niedrigen als auch mit einem hohen Mechanical Index (MI). SonoVue® wurde in einer Konzentration von 0,25\%, 0,5\% und 1\%, Levovist in einer Konzentration von 5\% bezogen auf ein Gesamtvolumen in-vitro von 20ml getestet. Als Vergleichsparameter diente die in-vitro Kontrastdauer. Diese wurde definiert als der Zeitraum vom Beginn der Messung bis zu dem Zeitpunkt, an dem auf mehr als 50\% der Bildfl{\"a}che keine echogenen Mikrobl{\"a}schen mehr nachweisbar waren. ERGEBNISSE: Die {\"A}nderung der oben genannten Konzentrationen hatte keinen entscheidenden Einfluss auf die Kontrastdauer von SonoVue®. Dar{\"u}ber hinaus konnte beim Umschalten von THI low MI auf THI high MI die Kontrastdauer von SonoVue® signifikant verl{\"a}ngert werden. Betrachtet man die Abbildungsmodalit{\"a}t THI mit hohem MI, welche routinem{\"a}ßig bei Levovist® angewendet wird, so zeigte sich, dass die Kontrastdauer bei Levovist® in einer Konzentration von 5\% bei 1,1 Minuten lag, bei SonoVue® hingegen erhielten wir bei einer Konzentration von 1\% eine Kontrastdauer von 7,3 Minuten. Dies bedeutet, dass trotz Verwendung einer f{\"u}nffach geringeren Dosis bei SonoVue® sich die Kontrastdauer in-vitro um mehr als 80\% verl{\"a}ngerte. Dar{\"u}ber hinaus blieb die Kontrastdauer von SonoVue® {\"u}ber einen Zeitraum von 6 Stunden weitestgehend stabil, w{\"a}hrend bei Levovist® die Kontrastdauer schon nach 0,5 Stunden eine deutliche Reduktion zeigte. SCHLUSSFOLGERUNG: Es ist zu erwarten, dass SonoVue® auch bei intravesicalen Applikationen in einer deutlich niedrigeren Dosis (1\% des Blasenvolumens) verwendet werden kann und dass mehrere Untersuchungen {\"u}ber einen l{\"a}ngeren Zeitraum mit einer Flasche SonoVue® durchgef{\"u}hrt werden k{\"o}nnen. Somit w{\"u}rde eine Kostenreduktion erreicht werden.}, language = {de} } @article{RiedlKampfHeroldetal.2020, author = {Riedl, Katharina A. and Kampf, Thomas and Herold, Volker and Behr, Volker C. and Bauer, Wolfgang R.}, title = {Wall shear stress analysis using 17.6 Tesla MRI: A longitudinal study in ApoE\(^{-/-}\)mice with histological analysis}, series = {PLoS One}, volume = {15}, journal = {PLoS One}, number = {8}, doi = {10.1371/journal.pone.0238112}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-229318}, year = {2020}, abstract = {This longitudinal study was performed to evaluate the feasibility of detecting the interaction between wall shear stress (WSS) and plaque development. 20 ApoE\(^{-/-}\)mice were separated in 12 mice with Western Diet and 8 mice with Chow Diet. Magnetic resonance (MR) scans at 17.6 Tesla and histological analysis were performed after one week, eight and twelve weeks. Allin vivoMR measurements were acquired using a flow sensitive phase contrast method for determining vectorial flow. Histological sections were stained with Hematoxylin and Eosin, Elastica van Gieson and CD68 staining. Data analysis was performed using Ensight and a Matlab-based "Flow Tool". The body weight of ApoE\(^{-/-}\)mice increased significantly over 12 weeks. WSS values increased in the Western Diet group over the time period; in contrast, in the Chow Diet group the values decreased from the first to the second measurement point. Western Diet mice showed small plaque formations with elastin fragmentations after 8 weeks and big plaque formations after 12 weeks; Chow Diet mice showed a few elastin fragmentations after 8 weeks and small plaque formations after 12 weeks. Favored by high-fat diet, plaque formation results in higher values of WSS. With wall shear stress being a known predictor for atherosclerotic plaque development, ultra highfield MRI can serve as a tool for studying the causes and beginnings of atherosclerosis.}, language = {en} } @phdthesis{Richter2021, author = {Richter, Julian Alexander J{\"u}rgen}, title = {Wave-CAIPI for Accelerated Dynamic MRI of the Thorax}, doi = {10.25972/OPUS-23207}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-232071}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2021}, abstract = {In summary, the wave-CAIPI k-space trajectory presents an efficient sampling strategy for accelerated MR acquisitions. Using wave-CAIPI in parallel imaging reconstructions leads to a reduced noise level in the reconstructed images, compared to the Cartesian standard trajectory. This effect could be quantified by means of noise and SNR calculations. An SNR gain can be traded for a reduced scan time, i.e., additional undersampling, or for an enhanced image quality, keeping scan time constant. Acceleration of MR imaging is especially important in dynamic applications, since these examinations are inherently time-consuming. The impact of wave-CAIPI sampling on image quality and its potential for scan time reduction was investigated for two dynamic applications: self-gated dynamic 3D lung MRI during free breathing and cardiac 4D flow MRI. Dynamic 3D Lung MRI By employing wave-CAIPI sampling in self-gated, free-breathing dynamic 3D lung MRI for the purpose of radiotherapy treatment planning, the image quality of accelerated scans could be enhanced. Volunteer examinations were used to quantify image quality by means of similarity between accelerated and reference images. To this end, the normalized mutual information and the root-mean-square error were chosen as quantitative image similarity measures. The wave-CAIPI sampling was shown to exhibit superior quality, especially for short scan times. The values of the normalized mutual information were (10.2 +- 7.3)\% higher in the wave-CAIPI case -- the root-mean-square error was (18.9 +- 13.2)\% lower on average. SNR calculations suggest an average SNR benefit of around 14\% for the wave-CAIPI, compared to Cartesian sampling. Resolution of the lung in 8 breathing states can be achieved in only 2 minutes. By using the wave-CAIPI k-space trajectory, precise tumor delineation and assessment of respiration-induced displacement is facilitated. Cardiac 4D Flow MRI In 4D flow MRI, acceleration of the image acquisition is essential to incorporate the corresponding scan protocols into clinical routine. In this work, a retrospective 6-fold acceleration of the image acquisition was realized. Cartesian and wave-CAIPI 4D flow examinations of healthy volunteers were used to quantify uncertainties in flow parameters for the respective sampling schemes. By employing wave-CAIPI sampling, the estimated errors in flow parameters in 6-fold accelerated scans could be reduced by up to 55\%. Noise calculations showed that the noise level in 6-fold accelerated 4D flow acquisitions with wave-CAIPI is 43\% lower, compared to Cartesian sampling. Comparisons between Cartesian and wave-CAIPI 4D flow examinations with a prospective acceleration factor R=2 revealed small, but partly statistically significant discrepancies. Differences between 2-fold and 6-fold accelerated wave-CAIPI scans are comparable to the differences between Cartesian and wave-CAIPI examinations at R=2. Wave-CAIPI 4D flow acquisitions of the aorta could be performed with an average, simulated scan time of under 4 minutes, with reduced uncertainties in flow parameters. Important visualizations of hemodynamic flow patterns in the aorta were only slightly affected by undersampling in the wave-CAIPI case, whereas for Cartesian sampling, considerable discrepancies were observed.}, subject = {Magnetresonanztomographie}, language = {en} } @article{RichterWechWengetal.2020, author = {Richter, Julian A. J. and Wech, Tobias and Weng, Andreas M. and Stich, Manuel and Weick, Stefan and Breuer, Kathrin and Bley, Thorsten A. and K{\"o}stler, Herbert}, title = {Free-breathing self-gated 4D lung MRI using wave-CAIPI}, series = {Magnetic Resonance in Medicine}, volume = {84}, journal = {Magnetic Resonance in Medicine}, number = {6}, doi = {10.1002/mrm.28383}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-218075}, pages = {3223 -- 3233}, year = {2020}, abstract = {Purpose The aim of this study was to compare the wave-CAIPI (controlled aliasing in parallel imaging) trajectory to the Cartesian sampling for accelerated free-breathing 4D lung MRI. Methods The wave-CAIPI k-space trajectory was implemented in a respiratory self-gated 3D spoiled gradient echo pulse sequence. Trajectory correction applying the gradient system transfer function was used, and images were reconstructed using an iterative conjugate gradient SENSE (CG SENSE) algorithm. Five healthy volunteers and one patient with squamous cell carcinoma in the lung were examined on a clinical 3T scanner, using both sampling schemes. For quantitative comparison of wave-CAIPI and standard Cartesian imaging, the normalized mutual information and the RMS error between retrospectively accelerated acquisitions and their respective references were calculated. The SNR ratios were investigated in a phantom study. Results The obtained normalized mutual information values indicate a lower information loss due to acceleration for the wave-CAIPI approach. Average normalized mutual information values of the wave-CAIPI acquisitions were 10\% higher, compared with Cartesian sampling. Furthermore, the RMS error of the wave-CAIPI technique was lower by 19\% and the SNR was higher by 14\%. Especially for short acquisition times (down to 1 minute), the undersampled Cartesian images showed an increased artifact level, compared with wave-CAIPI. Conclusion The application of the wave-CAIPI technique to 4D lung MRI reduces undersampling artifacts, in comparison to a Cartesian acquisition of the same scan time. The benefit of wave-CAIPI sampling can therefore be traded for shorter examinations, or enhancing image quality of undersampled 4D lung acquisitions, keeping the scan time constant.}, language = {en} } @phdthesis{Richter2015, author = {Richter, Julia Babette Marianne}, title = {Vergleich der Wertigkeit von Magnetresonanz-Enterographie und farbkodierter Duplex-Sonographie bei chronisch entz{\"u}ndlichen Darmerkrankungen im Kindes- und Jugendlichenalter}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-140336}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2015}, abstract = {In der S3-Leitlinie „Diagnostik und Therapie des Morbus Crohn" von 2008 war lediglich die Sonographie als prim{\"a}r bildgebendes Verfahren verankert; der Einsatz der D{\"u}nndarm-MRT blieb optional und ohne feste Position im Diagnostik-Algorithmus der CED. Im Unterschied hierzu st{\"a}rkt die 2014 aktualisierte entsprechende S3-Leitlinie den Stellenwert der MRT als bildgebende Modalit{\"a}t. Weiterhin bestehen bleibt die Sonographie als prim{\"a}re Bildgebung; eine MRT soll jedoch ebenfalls erfolgen: zur Prim{\"a}rdiagnostik, zur Erkennung extraintestinaler Komplikationen und zur Beurteilung endoskopisch nicht einsehbarer Darmabschnitte. Dar{\"u}ber hinaus kann sie in Verlaufskontrollen angewendet werden, falls erforderlich. Da sich diese jungen Patienten bei langer Krankheitsdauer in der Regel einer hohen Zahl an Untersuchungen unterziehen, sollte die M{\"o}glichkeit, dies strahlenexpositionsfrei durchf{\"u}hren zu k{\"o}nnen, unbedingt gew{\"a}hrleistet werden. Andernfalls ist mit einer erh{\"o}hten Rate an Malignomen im sp{\"a}teren Lebensalter zu rechnen. Daraus ergibt sich die Bedeutung einer Korrelation von mittels Ultraschall wie MRT erhobenen Befunden bei kindlicher CED. Hierzu liegen bislang nur wenige Untersuchungen vor, die zumeist auf den additiven Wert der Sonographie zur MRT und/oder dem additiven Wert der MR-Perfusionsanalyse fokussieren. Der hier vorgestellte Ansatz einer direkten Korrelation der Parameter Wanddicke und Perfusionsmarker zwischen Sonographie und MRT sowie gegen{\"u}ber klinischen Aktivit{\"a}tsmarkern (shPCDAI) ist innovativ. F{\"u}r das MRT konnten wir eine signifikante Korrelation von Wanddicke und Signalintensit{\"a}tszunahme zwei Minuten nach Kontrastmittelgabe f{\"u}r das terminale Ileum, der Pr{\"a}dilektionsstelle des Morbus Crohn, nachweisen. Ein Zusammenhang zwischen Wanddicke und klinischem Aktivit{\"a}tsindex konnte nicht gezeigt werden, jedoch zwischen Signalintensit{\"a}tszunahme und short PCDAI. Die Perfusionsanalyse sollte daher unserer Ansicht nach bei MRT-Untersuchungen zur Beantwortung der Frage „aktive Entz{\"u}ndung" herangezogen werden. F{\"u}r die Sonographie konnten wir keinen Zusammenhang von Wanddicke und Perfusion, jedoch eine signifikante Korrelation von Wanddicke und short PCDAI nachweisen. Die Perfusion korrelierte wiederum nicht mit dem klinischen Aktivit{\"a}tsindex. Die morphologische Wanddickenanalyse sollte daher f{\"u}r Sonographie-Untersuchungen zur Beantwortung der Frage „aktive Entz{\"u}ndung" herangezogen werden. Bei der Korrelation der MRT- und Sonographie-Ergebnisse zeigte sich ein gutes {\"U}bereinstimmen der Daten der Darmwanddicken-Messungen, die h{\"o}chste Korrelation ergab sich im terminalen Ileum. Auch f{\"u}r Signalintensit{\"a}tszunahmen (MRT) und Perfusion (FKDS) zeigte sich ein gutes {\"U}bereinstimmen - mit Ausnahme des Rektosigmoids (sp{\"a}te KM-Phase). Die gr{\"o}ßte Korrelation war auch hier im terminalen Ileum zu finden. Dies belegt die gute Vergleichbarkeit beider Modalit{\"a}ten. Eine Korrelation von MRAIs - USAI - shPCDAI ließ sich nicht nachweisen. Dies k{\"o}nnte an einer divergenten Einsch{\"a}tzung der Erkrankungsaktivit{\"a}t, jedoch auch an der kleinen Fallzahl liegen. Zur Erstellung des shPCDAI waren die retrospektiv erhobenen Variablen teils nicht ausreichend. Hauptlimitation f{\"u}r den USAI war die - teils durch Darmgas{\"u}berlagerung bedingte - unvollst{\"a}ndige Dokumentation. Die St{\"a}rke des MRAI lag dagegen bei konstant vorliegenden Messungen in f{\"u}nf Darmabschnitten. Trotz dieser Limitationen belegt die vorliegende Arbeit die Gleichwertigkeit beider Methoden in der Beurteilung von Darmwanddicken und eine bessere Korrelation wie Aussagekraft der MRT bei der Perfusionsanalyse. Aktuelle Publikationen belegen die Bedeutung Diffusionsgewichteter-MR-Bildgebung bei der CED-Diagnostik. Die DWI wurde im Rahmen unserer Untersuchung nicht angewendet, wird aber in Zukunft als vielversprechender, additiver Baustein oder sogar Ersatz f{\"u}r die Kontrastmittelgabe (Perfusionsanalyse) f{\"u}r MRT bei CED zu evaluieren sein.}, subject = {Magnetresonanztomographie}, language = {de} } @phdthesis{Remmert2008, author = {Remmert, Haiko}, title = {Quantitative klinische kardiale MR-Spektroskopie - Optimierung und Anwendung bei Patienten mit akutem Myokardinfarkt im Rahmen einer umfassenden Analyse von Anatomie, Funktion und Metabolismus}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-35643}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2008}, abstract = {Die 31P-MRS ist aktuell die einzige verf{\"u}gbare nicht-invasive Methode mit der der Herzmetabolismus ohne radioaktive Tracer untersucht werden kann. MRS erm{\"o}glicht Einblicke in die Energetik der isch{\"a}mischen Herzkrankheit, des Herzinfarkts, der hypertrophen Kardiomyopathie oder auch der Herzklappenfehler. Ferner kann die Methode zur {\"U}berwachung des Therapieerfolgs o.g. Krankheiten genutzt werden. Gegenw{\"a}rtig wird die MR-Spektroskopie, aufgrund der geringen r{\"a}umlichen und zeitlichen Aufl{\"o}sung sowie der geringen Reproduzierbarkeit, jedoch nur in der Forschung angewendet. Die Einf{\"u}hrung von MRT-Sytemen h{\"o}herer Feldst{\"a}rke, z.B. 7 Tesla, wird vermutlich eine Optimierung der Aufl{\"o}sung und Reproduzierbarkeit erm{\"o}glichen und damit die 31P-MRS in die klinische Diagnostik integrieren k{\"o}nnen. Die vorliegende Arbeit befasst sich neben der methodischen Weiterentwicklung und Standardisierung der MRS mit einem direkten Vergleich MR-tomographischer (LE) und MR-spektroskopischer (AW-CSI) Techniken zur Detektion von Infarktfolgen. Hierbei konnte durch die simultane Anwendung von MRS und Late Enhancement, ein bereits in der klinischen Infarktdiagnostik etabliertes Verfahren, die Aussagekraft der MR-Spektroskopie in Bezug auf die Infarktlokalisation validiert werden. Ein wesentlicher Vorteil der MRS gegen{\"u}ber dem Late Enhancement besteht darin, dass bereits fr{\"u}hzeitig pathologische Ver{\"a}nderungen des Metabolismus in Arealen wie dem remote, stunned oder hibernating myocardium detektiert werden k{\"o}nnen. Letztere demarkieren sich nicht beim LE. Unter Etablierung eines Segmentationsalgorithmus konnten sehr niedrige Variabilit{\"a}ten bei dem verwendeten Quantifizierungsprogramm („SLOOP") erreicht werden. Zus{\"a}tzlich gelang es durch systematische Analysen die f{\"u}r die Auswertung der MRS ben{\"o}tigten Nachbearbeitungszeiten drastisch zu verk{\"u}rzen. Als klinische Anwendung erfolgte die Bestimmung des kardialen Metabolismus mittels akquisitionsgewichteter 31P-3D-CSI bei Patienten mit Hinterwandinfarkt. Damit konnten erstmalig spulenferne Myokardareale (Hinterwand) hinsichtlich Ver{\"a}nderungen im Metabolismus erfasst werden. Ver{\"a}nderte PCr/\&\#947;ATP-ratios wurden bei Infarktpatienten gegen{\"u}ber einem Kollektiv herzgesunder Probanden gefunden. Eine exakte Lokalisation der untersuchten Infarkte und damit eine Validierung der spektroskopischen Datenanalyse wurden durch den Vergleich mit den simultan aufgenommenen Late Enhancement Bildern m{\"o}glich. Damit er{\"o}ffnet sich in Verbindung mit zunehmend zur Verf{\"u}gung stehenden Hochfeldger{\"a}ten (3T und mehr) f{\"u}r die MRS der Weg zu einem wichtigen klinischen Diagnostikwerkzeug zur Bestimmung von Prognoseparametern bei kardialen Erkrankungen.}, subject = {NMR-Spektroskopie}, language = {de} } @phdthesis{ReissZimmermann2008, author = {Reiß-Zimmermann, Martin}, title = {Entwicklung und Erprobung eines standardisierten Auswerteverfahrens f{\"u}r die Bestimmung der Myokardperfusion mit der MRT}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-34560}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2008}, abstract = {Mit dem hier vorgestellten Untersuchungs- und Auswertealgorithmus konnte die Myokardperfusion weitgehend automatisiert semiquantitativ und quantitativ bestimmt werden. Daf{\"u}r wurden zun{\"a}chst die Bilddaten segmentiert und in Signalintensit{\"a}ts-Zeit-Kurven transferiert. Durch eine Basislinien- und Kontaminationskorrektur wurden Artefakte minimiert. Mit Anwendung des Parallel-Bildgebungs-Verfahrens Auto-SENSE konnte zus{\"a}tzlich eine Erh{\"o}hung der Schichtanzahl erreicht werden. Durch die angewendete Basislinienkorrektur konnten Inhomogenit{\"a}ten verringert werden, welche durch Verwendung einer Oberfl{\"a}chenspule methodenbedingt auftreten. Partialvolumeneffekte, die durch die Morphologie des Herzens insbesondere basis- und spitzennah auftraten, f{\"u}hrten durch eine Mischung aus KM-Anflutung im Myokard und Kontamination aus dem Ventrikellumen zu einer Beeinflussung der Perfusionsergebnisse. Durch die Verwendung der vorgestellten Kontaminationskorrektur konnten diese Artefakte erheblich minimiert werden. Die so errechneten Perfusionswerte korrelierten gut mit den in der Literatur angegebenen Daten, welche sowohl in tierexperimentellen als auch Probanden- und auch Patientenstudien mit unterschiedlichen Modalit{\"a}ten ermittelt wurden. Eine regionale Heterogenit{\"a}t konnte nicht signifikant nachgewiesen werden. Molekular-physiologische Untersuchungen legen zwar nahe, dass es diese Heterogenit{\"a}t gibt, die regionale Verteilung der Perfusion wird jedoch kontrovers und noch keinesfalls abschließend in der Literatur diskutiert. Durch Anwendung von Auto-SENSE konnte mit einer Erh{\"o}hung der Schichtanzahl bei gleichbleibender Schichtdicke das gesamte linksventrikul{\"a}re Myokard untersucht werden. Trotz verringertem SNR waren die Ergebnisse vergleichbar mit der konventionellen Turbo-FLASH-Technik. Ob das Potential der Parallelbildgebung f{\"u}r eine Abdeckung des gesamten Herzens oder f{\"u}r eine h{\"o}here Aufl{\"o}sung von 3-4 Schichten pro Untersuchungen genutzt werden soll, ist in der aktuellen Literatur noch Gegenstand der Diskussion. Die hochaufgel{\"o}sten Untersuchungen scheinen jedoch derzeit vorteilhafter aufgrund geringerer Partialvolumeneffekte sowie der besseren Beurteilbarkeit einer subendokardialen Zone und eines transmuralen Perfusionsgradienten. Die MR-Perfusionsbildgebung ist ein aktives und rasch wachsendes Gebiet innerhalb der kardialen Bildgebung mit großem Entwicklungspotential. Durch Einbindung in ein umfassendes Herz-MR-Untersuchungsprotokoll (z.B. Morphologie, Kinetik, evtl. MR-Koronarangiographie) ist in einem Untersuchungsgang eine umfassende Diagnostik bei Patienten mit Verdacht auf KHK m{\"o}glich.}, subject = {NMR-Tomographie}, language = {de} } @article{ReichelHerzelTabbakhetal.2021, author = {Reichel, Thomas and Herz, Stefan and el Tabbakh, Mohammed and Bley, Thorsten Alexander and Plumhoff, Piet and Rueckl, Kilian}, title = {Less than 9.5-mm coracohumeral distance on axial magnetic resonance imaging scans predicts for subscapularis tear}, series = {JSES International}, volume = {5}, journal = {JSES International}, number = {3}, doi = {10.1016/j.jseint.2021.01.014}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-259118}, pages = {424-429}, year = {2021}, abstract = {Background Diagnosis of subscapularis (SSC) tendon lesions on magnetic resonance imaging (MRI) can be challenging. A small coracohumeral distance (CHD) has been associated with SSC tears. This study was designed to define a specific threshold value for CHD to predict SSC tears on axial MRI scans. Methods This retrospective study included 172 shoulders of 168 patients who underwent arthroscopic surgery for rotator cuff tear or glenohumeral instability. Diagnostic arthroscopy confirmed an SSC tear in 62 cases (36.0\%, test group a), rotator cuff tear tears other than SSC in 71 cases (41.3\%, control group b) and glenohumeral instability without any rotator cuff tear in 39 cases (22.7\%, zero-sample group c). All patients had a preoperative MRI of the shoulder (1.5T or 3T). Minimum CHD was measured on axial fat-suppressed proton density-, T2-, or T1-weigthed sequences. Receiver operating characteristics analysis was used to determine the threshold value for CHD, and sensitivity and specificity were calculated. Results CHD measurement had a good interobserver reliability (Intraclass correlation coefficient 0.799). Mean CHD was highly significantly (P < .001) less for test group a (mean 7.3 mm, standard deviation ± 2.2) compared with control group b (mean 11.1 mm, standard deviation ± 2.3) or zero-sample group c (mean 13.6 mm, standard deviation ± 2.9). A threshold value of CHD <9.5 mm had a sensitivity of 83.6\% and a specificity of 83.9\% to predict SSC tears. Conclusion A CHD <9.5 mm on MRI is predictive of SSC lesions and a valuable tool to diagnose SSC tears.}, language = {en} } @phdthesis{Reguillo2004, author = {Reguillo, Francisco J. J.}, title = {Organfilter in der konventionellen R{\"o}ntgendiagnostik und ihre Bedeutung f{\"u}r den Strahlenschutz}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-24130}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2004}, abstract = {Die vorliegende Arbeit untersucht den Effekt von Organfiltern insbesondere auf die Dosis. Im Rahmen dieser Untersuchung wurde die Dosis in Form des Fl{\"a}chendosisproduktes (FDP) gemessen. Filter bewirken nicht nur eine Verbesserung der Objektdarstellung in den normalerweise zu stark geschw{\"a}rzten Randpartien, sondern auch eine Dosisreduktion, d.h. die Organfilter sind gut geeignet, den Strahlenschutz positiv zu beeinflussen. Dieser Effekt der Dosisreduktion war bei den Keilfiltern (Mittel- und Vorfuß sowie HWS) weniger deutlich als bei den f{\"u}r Sch{\"a}del und Schulter angewendeten Filtern.}, subject = {Strahlenschutz}, language = {de} } @article{RascheKumarGershneretal.2019, author = {Rasche, Leo and Kumar, Manoj and Gershner, Grant and Samant, Rohan and Van Hemert, Rudy and Heidemeier, Anke and Lapa, Constantin and Bley, Thorsten and Buck, Andreas and McDonald, James and Hillengass, Jens and Epstein, Joshua and Thanendrarajan, Sharmilan and Schinke, Carolina and van Rhee, Frits and Zangari, Maurizio and Barlogie, Bart and Davies, Faith E. and Morgan, Gareth J. and Weinhold, Niels}, title = {Lack of Spleen Signal on Diffusion Weighted MRI is associated with High Tumor Burden and Poor Prognosis in Multiple Myeloma: A Link to Extramedullary Hematopoiesis?}, series = {Theranostics}, volume = {9}, journal = {Theranostics}, number = {16}, doi = {10.7150/thno.33289}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-224982}, pages = {4756-4763}, year = {2019}, abstract = {Due to the low frequency of abnormalities affecting the spleen, this organ is often overlooked during radiological examinations. Here, we report on the unexpected finding, that the spleen signal on diffusion-weighted MRI (DW-MRI) is associated with clinical parameters in patients with plasma cell dyscrasias. Methods: We investigated the spleen signal on DW-MRI together with clinical and molecular parameters in 295 transplant-eligible newly diagnosed Multiple Myeloma (NDMM) patients and in 72 cases with monoclonal gammopathy of undetermined significance (MGUS). Results: Usually, the spleen is the abdominal organ with the highest intensities on DW-MRI. Yet, significant signal loss on DW-MRI images was seen in 71 of 295 (24\%) NDMM patients. This phenomenon was associated with the level of bone marrow plasmacytosis (P=1x10(-10)) and International Staging System 3 (P=0.0001) but not with gain(1q), and del(17p) or plasma cell gene signatures. The signal was preserved in 72 individuals with monoclonal gammopathy of undetermined significance and generally re-appeared in MM patients responding to treatment, suggesting that lack of signal reflects increased tumor burden. While absence of spleen signal in MM patients with high risk disease defined a subgroup with very poor outcome, re-appearance of the spleen signal after autologous stem cell transplantation was seen in patients with improved outcome. Our preliminary observation suggests that extramedullary hematopoiesis in the spleen is a factor that modifies the DW-MRI signal of this organ. Conclusions: The DW-MRI spleen signal is a promising marker for tumor load and provides prognostic information in MM.}, language = {en} } @phdthesis{Rapf2007, author = {Rapf, Katrin}, title = {Perfusionsuntersuchungen des Herzens nach Myokardinfarkt mittels Magnetresonanztomographie}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-27297}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2007}, abstract = {Das Hauptziel der vorliegenden Arbeit war es, eine genauere Erkenntnis {\"u}ber die derzeitigen M{\"o}glichkeiten der quantitativen Messung der myokardiale Perfusion im Hinblick auf die Beschreibung verschiedener myokardialer Infarkte mittels kardialer MRT zu gewinnen. Die Untersuchungen zur Perfusion im Infarktgebiet ergaben, dass ein visuell festgestellter subendokardialer Infarkt an Hand der Bestimmung der absoluten Perfusion nicht immer nachvollzogen werden konnte. Ein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der H{\"o}he der absoluten Perfusion im Infarktgebiet konnte nicht gezeigt werden. Die Untersuchungen zur Perfusion im Remote Myokard ergaben keinen Zusammenhang zwischen der Perfusion im Remote Myokard und dem transmuralen Ausmaß des no-reflow-Ph{\"a}nomens in der First Pass Perfusion. Auch korrelierte die Perfusion im Remote Myokard nicht mit dem Auftreten eines no-reflow Ph{\"a}nomens im Late Enhancement. Die Perfusion im Remote Myokard unterschied sich zwischen transmuralen und nicht-transmuralen Infarkten. Eine Hyperperfusion im Remote Myokard konnte erst ab einer Infarktausdehnung von 75\% im Late Enhancement beobachtet werden, w{\"a}hrend eine Hypoperfusion im Remote Myokard bei allen Infarktausdehnungen zwischen 0\% und 100\% auftrat. Die Untersuchungen zur Perfusion bei Vorliegen eines transmuralen Infarktes" ergaben eine signifikante Korrelation der Perfusionen in Infarktgebiet und Remote Myokard bei transmuralem Infarkten. Die Ergebnisse zur Messung der Perfusion in Abh{\"a}ngigkeit von der relativen Infarktgr{\"o}ße wiesen keinen Zusammenhang zwischen der Perfusion im Infarktgebiet und der relativen Infarktgr{\"o}ße auf. Ebenso konnte keine Beziehung zwischen der Perfusion im Remote Myokard und der relativen Infarktgr{\"o}ße dargelegt werden. Letztendlich wurde das Verhalten der quantitativen Perfusion im Infarktgebiet und im Remote Myokard in Abh{\"a}ngigkeit von der Zeit nach Infarktereignis untersucht. Dabei zeigte sich kein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Entwicklung der Perfusion im Infarktgebiet zwischen der Erst- und der Sp{\"a}tuntersuchung. Ebenso war kein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Entwicklung der Perfusion im Remote Myokard zwischen der Erst- und der Sp{\"a}tuntersuchung erkennbar. Die kardiale MRT ist aufgrund der gleichzeitigen Analyse von morphologischen, funktionellen, quantitativen und metabolischen Parametern in einem Untersuchungsgang ein erfolgversprechendes Bildgebungsverfahren der Zukunft, da sie nicht invasiv ist, ohne Einsatz von R{\"o}ntgenstrahlung auskommt und dabei eine gute r{\"a}umliche Aufl{\"o}sung bei hohem Gewebekontrast bietet. Studien zeigen, dass die Kombination von Stress-Perfusion und Late-Technik in einem MRT-Protokoll eine h{\"o}here Genauigkeit als die Verwendung der SPECT-Untersuchung in der klinischen Beurteilung von Koronargef{\"a}ßstenosen und im Nachweis subendokardialer Infarkte aufweist. 62 Allerdings erf{\"a}hrt die in vorliegender Arbeit verwendete Technik der Datenverarbeitung in dieser Form ohne Zweifel noch ihre Limitation im klinischen Alltag. Grunds{\"a}tzlich ist zu sagen, dass die Messung der absoluten Perfusion im Myokard mit der MRT des Herzens zurzeit sicherlich noch nicht ausgereift ist. Dennoch lassen die in dieser Arbeit vorgestellten Ergebnisse und die viel versprechende Weiterentwicklung in der magnetresonanztomographischen Bildgebung weit reichende und interessante M{\"o}glichkeiten erahnen.}, subject = {Perfusion}, language = {de} } @phdthesis{Rapf2007, author = {Rapf, Christian}, title = {Magnetresonanztomographische Untersuchungen des Herzens zur Differenzierung des "no-reflow" Ph{\"a}nomens nach Myokardinfarkt}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-25811}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2007}, abstract = {Ziel der vorliegenden Arbeit war es, einen genaueren Aufschluss {\"u}ber die Erfassung der mikrovaskul{\"a}ren Integrit{\"a}t von Myokardinfarkten nach erfolgreicher koronarer Revaskularisierung mittels kardialer MR-Bildgebungstechniken zu geben. Dazu wurde zuerst das Auftreten des „no-reflow" in der FPP und im LE sowie zu verschiedenen Zeitintervallen untersucht. Die Untersuchungen hierzu ergaben ein h{\"a}ufigeres Auftreten des „no-reflow" in den FPP-Untersuchungen und eine Abnahme des beobachtbaren „no-reflow", je sp{\"a}ter die Untersuchung nach Kontrastmittelgabe erfolgte. Zus{\"a}tzlich zeigte sich, dass das Auftreten eines „no-reflow" in der LE-Untersuchung immer mit einem Auftreten in der FPP einherging. Weiterhin wurden die Auswirkungen des Infarktausmaßes auf das „no-reflow" {\"u}berpr{\"u}ft. Bei den Untersuchungen wurde zwischen Infarktvolumen und transmuraler Infarktgr{\"o}ße unterschieden. Dabei zeigte sich, dass das Auftreten eines „no-reflow" in der FPP- und LE-Untersuchung besser mit dem relativen Infarktvolumen als mit dem transmuralen Infarktausmaß korrelierte. Infarkte mit einem relativen Volumen kleiner neun Prozent ließen kein „no-reflow" im LE beobachten, wobei bei einem Infarktvolumen > 15 \% ein „no-reflow" sowohl in der FPP- als auch in der LE-Untersuchung beobachtbar war. Die Untersuchungen zum transmuralen Infarktausmaß zeigten, dass ein „no-reflow" auch bei nicht transmuralen Infarkten auftrat. Daneben konnte beobachtet werden, dass auch transmurale Infarkte ohne „no-reflow" auftreten. Des Weiteren wurden die Auswirkungen eines beobachtbaren „no-reflow" auf die EF {\"u}berpr{\"u}ft. Die EF wurde hierzu 14 Tage und drei Monate nach Myokardinfarkt bestimmt und mit dem „no-reflow" in der FPP und im LE der Erstuntersuchung verglichen. Hierbei zeigten zum ersten Untersuchungszeitpunkt in der FPP-Untersuchung mehr als 50 \% der Infarkte sowohl bei einer EF < 55 \% als auch bei einer EF > 55 \% ein „no-reflow". Dagegen war in der LE-Untersuchung bei einer EF < 55 \% kein Unterschied bez{\"u}glich der Beobachtung eines „no-reflow" feststellbar, w{\"a}hrend bei einer EF > 55 \% {\"u}ber 70 \% der Infarkte kein „no-reflow" aufwiesen. In der „Untersuchung nach drei Monaten" zeigten in der FPP-Untersuchung bei einer EF < 55 \% knapp 75 \% der Infarkte ein „no-reflow", w{\"a}hrend es bei einer EF > 55 \% ungef{\"a}hr 25 \% waren. In der LE-Untersuchung war, {\"a}hnlich dem ersten Untersuchungszeitpunkt, bei einer EF < 55 \% kein wesentlicher Unterschied festzustellen, wohingegen bei einer EF > 55 \% {\"u}ber 75 \% der Infarkte kein beobachtbares „no-reflow" im LE zeigten. F{\"u}r die FPP- und LE-Untersuchung ergab sich bei beiden Untersuchungszeitpunkten kein statistischer signifikanter Unterschied bez{\"u}glich der EF der Patienten, die „no-reflow" zeigten, zu den Patienten, die kein „no-reflow" zeigten. Ohne Zweifel ist die kardiale MRT aufgrund des nichtinvasiven dreidimensionalen Charakters und des guten Gewebekontrastes ohne Einsatz von R{\"o}ntgenstrahlung ein viel versprechendes bildgebendes Verfahren der Zukunft. Der Vorteil der Anwendung dieses Verfahrens bei Patienten mit Myokardinfarkt ist die pr{\"a}zise Bewertung des transmuralen Ausmaßes der myokardialen Nekrose sowie des „no-reflow" und die gleichzeitige Erfassung der Herzfunktionsparameter. Der Stand der Erfassung und Bewertung des „no-reflow" in MRT-Bildern reicht jedoch zurzeit noch nicht f{\"u}r den Einsatz in der klinischen Routinediagnostik aus. Die in dieser Arbeit vorgestellten Ergebnisse sollen einen Beitrag f{\"u}r diese Weiterentwicklung leisten. F{\"u}r einen sp{\"a}teren Standard zur Erfassung der mikrovaskul{\"a}ren Integrit{\"a}t beim Akuten Koronarsyndrom sind jedoch weitere Studien n{\"o}tig. Hierbei w{\"a}ren genauere Untersuchungen zum Schweregrad des „no-reflow" sowie zum Auftreten zu verschiedenen Zeitpunkten sinnvoll. Außerdem sollten exaktere Aussagen {\"u}ber die Korrelation des Auftretens des „no-reflow" und den Herzfunktionsparametern erhoben werden. Es ist anzunehmen, dass sich durch eine Weiterentwicklung der kardialen MRT der Informationsgehalt in Zukunft stetig steigern wird und dadurch eine eindrucksvolle Erg{\"a}nzung der kardiologischen Differentialdiagnostik sein. Dabei k{\"o}nnte eine multimodale Akquisition der kardialen Makro- und Mikrozirkulation, pathologischer Gewebever{\"a}nderungen und myokardialer Funktionsst{\"o}rungen in einem Untersuchungsgang mit einem kurzen zeitlichen Aufwand erreicht werden. Durch Integration der MRT-Untersuchungen zum „no-reflow" in den klinischen Alltag k{\"o}nnte somit eine Bestimmung des individuellen Risikos sowie ein risikoadaptiertes Behandlungskonzept erreicht werden.}, subject = {NMR-Tomographie}, language = {de} } @phdthesis{Portmann2023, author = {Portmann, Johannes}, title = {Accelerated inversion recovery MRI of the myocardium using spiral acquisition}, doi = {10.25972/OPUS-30282}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-302822}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2023}, abstract = {This work deals with the acceleration of cardiovascular MRI for the assessment of functional information in steady-state contrast and for viability assessment during the inversion recovery of the magnetization. Two approaches are introduced and discussed in detail. MOCO-MAP uses an exponential model to recover dynamic image data, IR-CRISPI, with its low-rank plus sparse reconstruction, is related to compressed sensing. MOCO-MAP is a successor to model-based acceleration of parametermapping (MAP) for the application in the myocardial region. To this end, it was augmented with a motion correction (MOCO) step to allow exponential fitting the signal of a still object in temporal direction. Iteratively, this introduction of prior physical knowledge together with the enforcement of consistency with the measured data can be used to reconstruct an image series from distinctly shorter sampling time than the standard exam (< 3 s opposed to about 10 s). Results show feasibility of the method as well as detectability of delayed enhancement in the myocardium, but also significant discrepancies when imaging cardiac function and artifacts caused already by minor inaccuracy of the motion correction. IR-CRISPI was developed from CRISPI, which is a real-time protocol specifically designed for functional evaluation of image data in steady-state contrast. With a reconstruction based on the separate calculation of low-rank and sparse part, it employs a softer constraint than the strict exponential model, which was possible due to sufficient temporal sampling density via spiral acquisition. The low-rank plus sparse reconstruction is fit for the use on dynamic and on inversion recovery data. Thus, motion correction is rendered unnecessary with it. IR-CRISPI was equipped with noise suppression via spatial wavelet filtering. A study comprising 10 patients with cardiac disease show medical applicability. A comparison with performed traditional reference exams offer insight into diagnostic benefits. Especially regarding patients with difficulty to hold their breath, the real-time manner of the IR-CRISPI acquisition provides a valuable alternative and an increase in robustness. In conclusion, especially with IR-CRISPI in free breathing, a major acceleration of the cardiovascular MR exam could be realized. In an acquisition of less than 100 s, it not only includes the information of two traditional protocols (cine and LGE), which take up more than 9.6 min, but also allows adjustment of TI in retrospect and yields lower artifact level with similar image quality.}, subject = {Kernspintomografie}, language = {en} } @article{PietroGarciaHartmannReisslandetal.2022, author = {Pietro-Garcia, Christian and Hartmann, Oliver and Reissland, Michaela and Fischer, Thomas and Maier, Carina R. and Rosenfeldt, Mathias and Sch{\"u}lein-V{\"o}lk, Christina and Klann, Kevin and Kalb, Reinhard and Dikic, Ivan and M{\"u}nch, Christian and Diefenbacher, Markus E.}, title = {Inhibition of USP28 overcomes Cisplatin-resistance of squamous tumors by suppression of the Fanconi anemia pathway}, series = {Cell Death and Differentiation}, volume = {29}, journal = {Cell Death and Differentiation}, number = {3}, issn = {1476-5403}, doi = {10.1038/s41418-021-00875-z}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-273014}, pages = {568-584}, year = {2022}, abstract = {Squamous cell carcinomas (SCC) frequently have an exceptionally high mutational burden. As consequence, they rapidly develop resistance to platinum-based chemotherapy and overall survival is limited. Novel therapeutic strategies are therefore urgently required. SCC express ∆Np63, which regulates the Fanconi Anemia (FA) DNA-damage response in cancer cells, thereby contributing to chemotherapy-resistance. Here we report that the deubiquitylase USP28 is recruited to sites of DNA damage in cisplatin-treated cells. ATR phosphorylates USP28 and increases its enzymatic activity. This phosphorylation event is required to positively regulate the DNA damage repair in SCC by stabilizing ∆Np63. Knock-down or inhibition of USP28 by a specific inhibitor weakens the ability of SCC to cope with DNA damage during platin-based chemotherapy. Hence, our study presents a novel mechanism by which ∆Np63 expressing SCC can be targeted to overcome chemotherapy resistance. Limited treatment options and low response rates to chemotherapy are particularly common in patients with squamous cancer. The SCC specific transcription factor ∆Np63 enhances the expression of Fanconi Anemia genes, thereby contributing to recombinational DNA repair and Cisplatin resistance. Targeting the USP28-∆Np63 axis in SCC tones down this DNA damage response pathways, thereby sensitizing SCC cells to cisplatin treatment.}, language = {en} } @article{PetritschPannbeckerWengetal.2021, author = {Petritsch, Bernhard and Pannbecker, Pauline and Weng, Andreas M. and Grunz, Jan-Peter and Veldhoen, Simon and Bley, Thorsten A. and Kosmala, Aleksander}, title = {Split-filter dual-energy CT pulmonary angiography for the diagnosis of acute pulmonary embolism: a study on image quality and radiation dose}, series = {Quantitative Imaging in Medicine and Surgery}, volume = {11}, journal = {Quantitative Imaging in Medicine and Surgery}, number = {5}, doi = {10.21037/qims-20-740}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-231456}, pages = {1817-1827}, year = {2021}, abstract = {Background: Computed tomography (CT) pulmonary angiography is the diagnostic reference standard in suspected pulmonary embolism (PE). Favorable results for dual-energy CT (DECT) images have been reported for this condition. Nowadays, dual-energy data acquisition is feasible with different technical options, including a single-source split-filter approach. Therefore, the aim of this retrospective study was to investigate image quality and radiation dose of thoracic split-filter DECT in comparison to conventional single-energy CT in patients with suspected PE. Methods: A total of 110 CT pulmonary angiographies were accomplished either as standard single-energy CT with automatic tube voltage selection (ATVS) (n=58), or as split-filter DECT (n=52). Objective [pulmonary artery CT attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)] and subjective image quality [four-point Likert scale; three readers (R)] were compared among the two study groups. Size-specific dose estimates (SSDE), dose-length-product (DLP) and volume CT dose index (CTDIvol) were assessed for radiation dose analysis. Results: Split-filter DECT images yielded 67.7\% higher SNR (27.0 vs. 16.1; P<0.001) and 61.9\% higher CNR (22.5 vs. 13.9; P<0.001) over conventional single-energy images, whereas CT attenuation was significantly lower (344.5 vs. 428.2 HU; P=0.013). Subjective image quality was rated good or excellent in 93.0\%/98.3\%/77.6\% (R1/R2/R3) of the single-energy CT scans, and 84.6\%/82.7\%/80.8\% (R1/R2/R3) of the split-filter DECT scans. SSDE, DLP and CTDIvol were significantly lower for conventional single-energy CT compared to split-filter DECT (all P<0.05), which was associated with 26.7\% higher SSDE. Conclusions: In the diagnostic workup of acute PE, the split-filter allows for dual-energy data acquisition from single-source single-layer CT scanners. The existing opportunity to assess pulmonary "perfusion" based on analysis of iodine distribution maps is associated with higher radiation dose in terms of increased SSDE than conventional single-energy CT with ATVS. Moreover, a proportion of up to 3.8\% non-diagnostic examinations in the current reference standard test for PE is not negligible.}, language = {en} } @article{PetritschKoestlerGassenmaieretal.2016, author = {Petritsch, Bernhard and K{\"o}stler, Herbert and Gassenmaier, Tobias and Kunz, Andreas S and Bley, Thorsten A and Horn, Michael}, title = {An investigation into potential gender-specific differences in myocardial triglyceride content assessed by \(^{1}\)H-Magnetic Resonance Spectroscopy at 3Tesla}, series = {Journal of International Medical Research}, volume = {44}, journal = {Journal of International Medical Research}, number = {3}, doi = {10.1177/0300060515603884}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-168808}, pages = {585-591}, year = {2016}, abstract = {Objective: Over the past decade, myocardial triglyceride content has become an accepted biomarker for chronic metabolic and cardiac disease. The purpose of this study was to use proton (hydrogen 1)-magnetic resonance spectroscopy (\(^{1}\)H-MRS) at 3Tesla (3 T) field strength to assess potential gender-related differences in myocardial triglyceride content in healthy individuals. Methods: Cardiac MR imaging was performed to enable accurate voxel placement and obtain functional and morphological information. Double triggered (i.e., ECG and respiratory motion gating) \(^{1}\)H-MRS was used to quantify myocardial triglyceride levels for each gender. Two-sample t-test and Mann-Whitney U-test were used for statistical analyses. Results: In total, 40 healthy volunteers (22 male, 18 female; aged >18 years and age matched) were included in the study. Median myocardial triglyceride content was 0.28\% (interquartile range [IQR] 0.17-0.42\%) in male and 0.24\% (IQR 0.14-0.45\%) in female participants, and no statistically significant difference was observed between the genders. Furthermore, no gender-specific difference in ejection fraction was observed, although on average, male participants presented with a higher mean ± SD left ventricular mass (136.3 ± 25.2 g) than female participants (103.9 ± 16.1 g). Conclusions: The study showed that \(^{1}\)H-MRS is a capable, noninvasive tool for acquisition of myocardial triglyceride metabolites. Myocardial triglyceride concentration was shown to be unrelated to gender in this group of healthy volunteers.}, language = {en} } @article{PetritschGoltzHahnetal.2011, author = {Petritsch, Bernhard and Goltz, Jan Peter and Hahn, Dietbert and Wendel, Frank}, title = {Extensive craniocervical bone pneumatization}, series = {Diagnostic and Interventional Radiology}, volume = {17}, journal = {Diagnostic and Interventional Radiology}, number = {4}, doi = {10.4261/1305-3825.DIR.4299-11.2}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-139349}, pages = {308-310}, year = {2011}, abstract = {We report a case of extensive abnormal craniocervical bone pneumatization accidentally found in a patient without any history of trauma or surgery. The patient had only mild unspecific thoracic pain and bilateral paresthesia that did not correlate with computed tomography findings.}, language = {en} } @article{PetritschKosmalaWengetal.2019, author = {Petritsch, Berhard and Kosmala, Aleksander and Weng, Andreas Max and Bley, Thorsten Alexander}, title = {Tin-filtered 100kV ultra-low-dose CT of the paranasal sinus: initial clinical results}, series = {PLoS ONE}, volume = {14}, journal = {PLoS ONE}, number = {5}, doi = {10.1371/ journal.pone.0216295}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-204127}, pages = {e0216295}, year = {2019}, abstract = {Objectives To investigate the feasibility, diagnostic image quality and radiation dose of 3\(^{rd}\) generation dual-source computed tomography (CT) using a tin-filtered 100 kV protocol in patients with suspected acute inflammatory sinus disease. Methods We retrospectively evaluated 109 consecutive patients who underwent CT (Siemens SOMATOM Force, Erlangen, Germany) of the paranasal sinus with a new tin-filtered scanprotocol (Sn100 kV; tube current 35 mAs) using iterative reconstruction. Two readers independently assessed subjective image quality using a five-point Likert scale (1 = excellent, 5 = non-diagnostic). Inter-observer agreement was calculated and expressed as percentage of agreement. Noise was determined for calculation of signal-to-noise-ratio (SNR). Effective radiation dose (ED) was calculated from the dose-length-product (DLP). Results All examinations showed diagnostic image quality regarding evaluation of inflammatory sinus disease. On average, subjective general image quality was rated moderate (= 3) with a percentage of agreement between the observers of 81\%. The mean image noise was 14.3 HU. The calculated median SNR was 6.0 for intraorbital fat, and 3.6 for the vitreous body, respectively. The median DLP was 2.1 mGy*cm, resulting in a median ED of 0.012 mSv. Conclusions Taking the study limitations into account, ultra-low-dose tin-filtered CT of the paranasal sinus at a tube voltage of 100 kV utilizing an iterative reconstruction algorithm provides for reliable exclusion of suspected acute inflammatory sinus disease in 100\% of the cases.}, language = {en} } @article{PennigHoyerKrauskopfetal.2021, author = {Pennig, Lenhard and Hoyer, Ulrike Cornelia Isabel and Krauskopf, Alexandra and Shahzad, Rahil and J{\"u}nger, Stephanie T. and Thiele, Frank and Laukamp, Kai Roman and Grunz, Jan-Peter and Perkuhn, Michael and Schlamann, Marc and Kabbasch, Christoph and Borggrefe, Jan and Goertz, Lukas}, title = {Deep learning assistance increases the detection sensitivity of radiologists for secondary intracranial aneurysms in subarachnoid hemorrhage}, series = {Neuroradiology}, volume = {63}, journal = {Neuroradiology}, number = {12}, issn = {0028-3940}, doi = {10.1007/s00234-021-02697-9}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-308117}, pages = {1985-1994}, year = {2021}, abstract = {Purpose To evaluate whether a deep learning model (DLM) could increase the detection sensitivity of radiologists for intracranial aneurysms on CT angiography (CTA) in aneurysmal subarachnoid hemorrhage (aSAH). Methods Three different DLMs were trained on CTA datasets of 68 aSAH patients with 79 aneurysms with their outputs being combined applying ensemble learning (DLM-Ens). The DLM-Ens was evaluated on an independent test set of 104 aSAH patients with 126 aneuryms (mean volume 129.2 ± 185.4 mm3, 13.0\% at the posterior circulation), which were determined by two radiologists and one neurosurgeon in consensus using CTA and digital subtraction angiography scans. CTA scans of the test set were then presented to three blinded radiologists (reader 1: 13, reader 2: 4, and reader 3: 3 years of experience in diagnostic neuroradiology), who assessed them individually for aneurysms. Detection sensitivities for aneurysms of the readers with and without the assistance of the DLM were compared. Results In the test set, the detection sensitivity of the DLM-Ens (85.7\%) was comparable to the radiologists (reader 1: 91.2\%, reader 2: 86.5\%, and reader 3: 86.5\%; Fleiss κ of 0.502). DLM-assistance significantly increased the detection sensitivity (reader 1: 97.6\%, reader 2: 97.6\%,and reader 3: 96.0\%; overall P=.024; Fleiss κ of 0.878), especially for secondary aneurysms (88.2\% of the additional aneurysms provided by the DLM). Conclusion Deep learning significantly improved the detection sensitivity of radiologists for aneurysms in aSAH, especially for secondary aneurysms. It therefore represents a valuable adjunct for physicians to establish an accurate diagnosis in order to optimize patient treatment.}, language = {en} } @article{PatzerKunzHuflageetal.2023, author = {Patzer, Theresa Sophie and Kunz, Andreas Steven and Huflage, Henner and Luetkens, Karsten Sebastian and Conrads, Nora and Gruschwitz, Philipp and Pannenbecker, Pauline and Erg{\"u}n, S{\"u}leyman and Bley, Thorsten Alexander and Grunz, Jan-Peter}, title = {Quantitative and qualitative image quality assessment in shoulder examinations with a first-generation photon-counting detector CT}, series = {Scientific Reports}, volume = {13}, journal = {Scientific Reports}, doi = {10.1038/s41598-023-35367-2}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-357925}, year = {2023}, abstract = {Photon-counting detector (PCD) CT allows for ultra-high-resolution (UHR) examinations of the shoulder without requiring an additional post-patient comb filter to narrow the detector aperture. This study was designed to compare the PCD performance with a high-end energy-integrating detector (EID) CT. Sixteen cadaveric shoulders were examined with both scanners using dose-matched 120 kVp acquisition protocols (low-dose/full-dose: CTDI\(_{vol}\) = 5.0/10.0 mGy). Specimens were scanned in UHR mode with the PCD-CT, whereas EID-CT examinations were conducted in accordance with the clinical standard as "non-UHR". Reconstruction of EID data employed the sharpest kernel available for standard-resolution scans (ρ\(_{50}\) = 12.3 lp/cm), while PCD data were reconstructed with both a comparable kernel (11.8 lp/cm) and a sharper dedicated bone kernel (16.5 lp/cm). Six radiologists with 2-9 years of experience in musculoskeletal imaging rated image quality subjectively. Interrater agreement was analyzed by calculation of the intraclass correlation coefficient in a two-way random effects model. Quantitative analyses comprised noise recording and calculating signal-to-noise ratios based on attenuation measurements in bone and soft tissue. Subjective image quality was higher in UHR-PCD-CT than in EID-CT and non-UHR-PCD-CT datasets (all p < 0.001). While low-dose UHR-PCD-CT was considered superior to full-dose non-UHR studies on either scanner (all p < 0.001), ratings of low-dose non-UHR-PCD-CT and full-dose EID-CT examinations did not differ (p > 0.99). Interrater reliability was moderate, indicated by a single measures intraclass correlation coefficient of 0.66 (95\% confidence interval: 0.58-0.73; p < 0.001). Image noise was lowest and signal-to-noise ratios were highest in non-UHR-PCD-CT reconstructions at either dose level (p < 0.001). This investigation demonstrates that superior depiction of trabecular microstructure and considerable denoising can be realized without additional radiation dose by employing a PCD for shoulder CT imaging. Allowing for UHR scans without dose penalty, PCD-CT appears as a promising alternative to EID-CT for shoulder trauma assessment in clinical routine.}, language = {en} } @article{PatzerKunzHuflageetal.2023, author = {Patzer, Theresa Sophie and Kunz, Andreas Steven and Huflage, Henner and Conrads, Nora and Luetkens, Karsten Sebastian and Pannenbecker, Pauline and Paul, Mila Marie and Erg{\"u}n, S{\"u}leyman and Bley, Thorsten Alexander and Grunz, Jan-Peter}, title = {Ultrahigh-resolution photon-counting CT in cadaveric fracture models: spatial frequency is not everything}, series = {Diagnostics}, volume = {13}, journal = {Diagnostics}, number = {10}, issn = {2075-4418}, doi = {10.3390/diagnostics13101677}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-319281}, year = {2023}, abstract = {In this study, the impact of reconstruction sharpness on the visualization of the appendicular skeleton in ultrahigh-resolution (UHR) photon-counting detector (PCD) CT was investigated. Sixteen cadaveric extremities (eight fractured) were examined with a standardized 120 kVp scan protocol (CTDI\(_{vol}\) 10 mGy). Images were reconstructed with the sharpest non-UHR kernel (Br76) and all available UHR kernels (Br80 to Br96). Seven radiologists evaluated image quality and fracture assessability. Interrater agreement was assessed with the intraclass correlation coefficient. For quantitative comparisons, signal-to-noise-ratios (SNRs) were calculated. Subjective image quality was best for Br84 (median 1, interquartile range 1-3; p ≤ 0.003). Regarding fracture assessability, no significant difference was ascertained between Br76, Br80 and Br84 (p > 0.999), with inferior ratings for all sharper kernels (p < 0.001). Interrater agreement for image quality (0.795, 0.732-0.848; p < 0.001) and fracture assessability (0.880; 0.842-0.911; p < 0.001) was good. SNR was highest for Br76 (3.4, 3.0-3.9) with no significant difference to Br80 and Br84 (p > 0.999). Br76 and Br80 produced higher SNRs than all kernels sharper than Br84 (p ≤ 0.026). In conclusion, PCD-CT reconstructions with a moderate UHR kernel offer superior image quality for visualizing the appendicular skeleton. Fracture assessability benefits from sharp non-UHR and moderate UHR kernels, while ultra-sharp reconstructions incur augmented image noise.}, language = {en} } @phdthesis{Pannenbecker2024, author = {Pannenbecker, Pauline Luisa}, title = {Vergleich von Dual- und Single-Source Dual-Energy CT in der Diagnostik der akuten Lungenarterienembolie hinsichtlich Bildqualit{\"a}t und Strahlendosis}, doi = {10.25972/OPUS-35206}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-352064}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2024}, abstract = {Hintergrund: Die CT-Pulmonalisangiographie (CTPA) ist diagnostischer Goldstandard der Diagnostik der Lungenarterienembolie (LAE). Durch Dual-Energy CT (DECT) k{\"o}nnen mithilfe von Joddistributionskarten LAEs auf Segment- und Subsegmentebene besser detektiert werden. Neben der etablierten Dual-Source-Technik erm{\"o}glicht ein Split-Filter eine DECT-Akquisition mit Single-Source-Scannern. Ein solcher SF-DECT-Scanner sollte hinsichtlich der Bildqualit{\"a}t sowie der Strahlendosis mit einem etabliertem DS-DECT-Ger{\"a}t verglichen werden. Material und Methoden: Insgesamt wurden 135 Patienten eingeschlossen, die eine CTPA erhielten: 68 erhielten einen DS-DECT-Scan mit 90/Sn150 kV und 67 einen SF-DECT-Scan mit Au/Sn120 kV. F{\"u}r beide Protokolle wurden farbkodierte Joddistributionskarten erstellt. Die objektive (CT-Abschw{\"a}chung in relevanten Gef{\"a}ßen in HU, Signal-Rausch-Verh{\"a}ltnis (SNR), Kontrast-Rausch-Verh{\"a}ltnis (CNR), perfused blood volume (PBV)) und subjektive Bildqualit{\"a}t (2 Befunder (B), 5-Punkte-Likert-Skala) sowie Dosisparameter wurden erhoben und verglichen. Ergebnisse: Alle CTPAs waren von diagnostischer Qualit{\"a}t. Ihre subjektive Bildqualit{\"a}t wurde in 80,9/82,4\% (B1/B2) der DS-DECT und in 77,6/76,1\% der SF-DECT als exzellent oder gut bewertet. Die subjektive Bildqualit{\"a}t der Joddistributionskarten der SF-DECT wurde von beiden Befundern als schlechter beurteilt. Die HU-Werte der relevanten Gef{\"a}ße unterschieden sich nicht signifikant (p>0.05), SNR und CNR der SF-Gruppe waren in zentralen Gef{\"a}ßen jedoch h{\"o}her (p<0.05); die PBV-Werte der SF-Gruppe waren teils h{\"o}her (p<0.05). Alle erhobenen Dosisparameter waren in der SF-Gruppe h{\"o}her (p<0,05). Konklusion: In der diagnostischen Abkl{\"a}rung eines V.a. eine akute LAE erm{\"o}glicht der Einsatz eines Split-Filters an einem Single-Source-CT-Scanner eine Dual-Energy-Untersuchung. Dies geht im Vergleich zu etablierten DS-Scannern jedoch mit einer schlechteren Qualit{\"a}t der Joddistributionskarten und einer h{\"o}heren Strahlendosis einher.}, subject = {Lungenembolie}, language = {de} } @phdthesis{Oechsner2011, author = {Oechsner, Markus}, title = {Morphologische und funktionelle 1H-Magnetresonanztomographie der menschlichen Lunge bei 0.2 und 1.5 Tesla}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-66942}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2011}, abstract = {Das Ziel dieser Arbeit war es, Methoden und Techniken f{\"u}r die morphologische und funktionelle Bildgebung der menschlichen Lunge mittels Kernspintomographie bei Feldst{\"a}rken von 0,2 Tesla und 1,5 Tesla zu entwickeln und zu optimieren. Bei 0,2 Tesla wurde mittels der gemessenen Relaxationszeiten T1 und T2* eine 2D und eine 3D FLASH Sequenz zur Untersuchung der Lungenmorphologie optimiert. Sauerstoffgest{\"u}tzte Messungen der Relaxationszeiten T1 und T2* sowie eine SpinLabeling Sequenz liefern funktionelle Informationen {\"u}ber den Sauerstofftransfer und die Perfusion der Lungen. Bei 1,5 Tesla wurde die Lungenperfusion mittels MR-Kontrastmittel mit einer 2D und einer 3D Sequenz unter Verwendung der Pr{\"a}bolus Technik quantifiziert. Zudem wurden zwei MR-Navigationstechniken entwickelt, die es erm{\"o}glichen Lungenuntersuchungen unter freier Atmung durchzuf{\"u}hren und aus den Daten artefaktfreie Bilder zu rekonstruieren. Diese Techniken k{\"o}nnen in verschiedenste Sequenzen f{\"u}r die Lungenbildgebung implementiert werden, ohne dass die Messzeit dadurch signifikant verl{\"a}ngert wird.}, subject = {NMR-Bildgebung}, language = {de} } @article{OderUeceylerLiuetal.2016, author = {Oder, Daniel and {\"U}ceyler, Nurcan and Liu, Dan and Hu, Kai and Petritsch, Bernhard and Sommer, Claudia and Ertl, Georg and Wanner, Christoph and Nordbeck, Peter}, title = {Organ manifestations and long-term outcome of Fabry disease in patients with the GLA haplotype D313Y}, series = {BMJ Open}, volume = {6}, journal = {BMJ Open}, doi = {10.1136/bmjopen-2015-010422}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-161210}, pages = {e010422}, year = {2016}, abstract = {Objectives: The severity of Fabry disease is dependent on the type of mutation in the α-galactosidase A (AgalA) encoding gene (GLA). This study focused on the impact of the GLA haplotype D313Y on long-term organ involvement and function. Setting and participants: In this monocentric study, all participants presenting with the D313Y haplotype between 2001 and 2015 were comprehensively clinically investigated at baseline and during a 4-year follow-up if available. Five females and one male were included. Primary and secondary outcome measures: Cardiac, nephrological, neurological, laboratory and quality of life data. Results: AgalA enzyme activity in leucocytes (0.3±0.9 nmol/min/mg protein (mean±SD)) and serum lyso-Gb3 (0.6±0.3 ng/mL at baseline) were in normal range in all patients. Cardiac morphology and function were normal (left-ventricular (LV) ejection fraction 66±8\%; interventricular septum 7.7±1.4 mm; LV posterior wall 7.5±1.4 mm; normalised LV mass in MRI 52±9 g/m2; LV global longitudinal strain -21.6±1.9\%) and there were no signs of myocardial fibrosis in cardiac MRI. Cardiospecific biomarkers were also in normal range. Renal function was not impaired (estimated glomerular filtration rate MDRD 103±15 mL/min; serum-creatinine 0.75±0.07 mg/dL; cystatin-c 0.71±0.12 mg/L). One female patient (also carrying a Factor V Leiden mutation) had a transitory ischaemic attack. One patient showed white matter lesions in brain MRI, but none had Fabry-associated pain attacks, pain crises, evoked pain or permanent pain. Health-related quality of life analysis revealed a reduction in individual well-being. At long-term follow-up after 4 years, no significant change was seen in any parameter. Conclusions: The results of the current study suggest that the D313Y genotype does not lead to severe organ manifestations as seen in genotypes known to be causal for classical FD."}, language = {en} } @article{NordbeckBeerKoestleretal.2012, author = {Nordbeck, Peter and Beer, Meinrad and K{\"o}stler, Herbert and Ladd, Mark E. and Quick, Harald H. and Bauer, Wolfgang R. and Ritter, Oliver}, title = {Cardiac catheter ablation under real-time magnetic resonance guidance}, series = {European Heart Journal}, volume = {33}, journal = {European Heart Journal}, number = {15}, doi = {10.1093/eurheartj/ehs139}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-125638}, year = {2012}, abstract = {One of the main shortcomings of interventional electrophysiology (EP) is its inability to generate sufficient soft tissue contrast for intra-procedural visualization of the myocardium and the surrounding tissue, using conventional imaging techniques. Interventional cardiovascular magnetic resonance imaging (MRI) aims at bringing about significant improvements to the complex and decisive EP interventions far beyond the capabilities of currently available supportive imaging techniques used to surmount the drawbacks of fluoroscopy, as MRI not only allows of precise three-dimensional exposure of the cardiovascular morphology, but also proves to be a promising technique exclusively suitable for direct visualization of arrhythmogenic substrate and therapeutic effects. The major challenge posed by clinical …}, language = {en} } @article{NeufangAkhrifHerrmannetal.2016, author = {Neufang, S. and Akhrif, A. and Herrmann, C.G. and Drepper, C. and Homola, G.A. and Nowak, J. and Waider, J. and Schmitt, A.G. and Lesch, K.-P. and Romanos, M.}, title = {Serotonergic modulation of 'waiting impulsivity' is mediated by the impulsivity phenotype in humans}, series = {Translational Psychiatry}, journal = {Translational Psychiatry}, number = {6}, doi = {10.1038/tp.2016.210}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-164418}, pages = {e940}, year = {2016}, abstract = {In rodents, the five-choice serial reaction time task (5-CSRTT) has been established as a reliable measure of waiting impulsivity being defined as the ability to regulate a response in anticipation of reinforcement. Key brain structures are the nucleus accumbens (NAcc) and prefrontal regions (for example, pre- and infralimbic cortex), which are, together with other transmitters, modulated by serotonin. In this functional magnetic resonance imaging study, we examined 103 healthy males while performing the 5-CSRTT measuring brain activation in humans by means of a paradigm that has been widely applied in rodents. Subjects were genotyped for the tryptophan hydroxylase-2 (TPH2; G-703T; rs4570625) variant, an enzyme specific for brain serotonin synthesis. We addressed neural activation patterns of waiting impulsivity and the interaction between the NAcc and the ventromedial prefrontal cortex (vmPFC) using dynamic causal modeling. Genetic influence was examined via interaction analyses between the TPH2 genotype (GG homozygotes vs T allele carriers) and the degree of impulsivity as measured by the 5-CSRTT. We found that the driving input of the vmPFC was reduced in highly impulsive T allele carriers (reflecting a reduced top-down control) in combination with an enhanced response in the NAcc after correct target processing (reflecting an augmented response to monetary reward). Taken together, we found a high overlap of our findings with reports from animal studies in regard to the underlying cognitive processes, the brain regions associated with waiting impulsivity and the neural interplay between the NAcc and vmPFC. Therefore, we conclude that the 5-CSRTT is a promising tool for translational studies.}, language = {en} } @article{NeubauerWirthRufetal.2012, author = {Neubauer, Henning and Wirth, Clemens and Ruf, Katharina and Hebestreit, Helge and Beer, Meinrad}, title = {Acute Muscle Trauma due to Overexercise in an Otherwise Healthy Patient with Cystic Fibrosis}, series = {Case Reports in Pediatrics}, volume = {2012}, journal = {Case Reports in Pediatrics}, number = {527989}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-123967}, year = {2012}, abstract = {Cystic fibrosis (CF) is one of the most common inherited diseases and is caused by mutations in the CFTR gene. Although the pulmonary and gastrointestinal manifestations of the disease remain in the focus of treatment, recent studies have shown expression of the CFTR gene product in skeletal muscle cells and observed altered intramuscular \(Ca^{2+}\) release dynamics in CFTR-deficient animal models. Physical exercise is beneficial for maintaining fitness and well-being in CF patients and constitutes one aspect of modern multimodal treatment, which has considerably increased life span and reduced morbidity. We report on a case of acute muscle trauma resulting from excessive dumbbell exercise in a young adult with cystic fibrosis and describe clinical, laboratory and imaging characteristics of acute exercise-induced muscle injury.}, language = {en} } @article{NeubauerMorbachSchwarzetal.2011, author = {Neubauer, Henning and Morbach, Henner and Schwarz, Tobias and Wirth, Clemens and Girschick, Hermann and Beer, Meinrad}, title = {Popliteal Cysts in Paediatric Patients: Clinical Characteristics and Imaging Features on Ultrasound and MRI}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-68662}, year = {2011}, abstract = {Popliteal cysts, or Baker cysts, are considered rare in children and may exhibit particular features, as compared with adults. We studied data from80 paediatric patients with 55 Baker cysts, examined over a period of 7 years, and correlated clinical presentation with findings on ultrasonography and MRI. Prevalence of popliteal cysts was 57\% in arthritic knees, 58\% with hypermobility syndrome, and 28\% without risk factors. Only one patient had a trauma history and showed an ipsilateral cyst. Mean cyst volume was 3.4 mL; cysts were larger in boys. Patients with arthritis had echogenic cysts in 53\%. Cyst communication with the joint space was seen in 64\% on ultrasonography and 86\% on MRI. In conclusion, Baker cysts are a common finding in a clinically preselected paediatric population. Children with Baker cysts should be assessed for underlying arthritis and inherited joint hypermobility, while sporadic Baker cysts appear to be common, as well.}, subject = {Medizin}, language = {en} } @article{NeubauerEvangelistaMorbachetal.2012, author = {Neubauer, Henning and Evangelista, Laura and Morbach, Henner and Girschick, Hermann and Prelog, Martina and K{\"o}stler, Herbert and Hahn, Dietbert and Beer, Meinrad}, title = {Diffusion-weighted MRI of bone marrow oedema, soft tissue oedema and synovitis in paediatric patients: feasibility and initial experience}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-75521}, year = {2012}, abstract = {Background: MRI has become the mainstay of diagnostic imaging in paediatric rheumatology for lesion detection, differential diagnosis and therapy surveillance. MR imaging of synovitis, in particular, is indispensable for early diagnosis and follow-up in arthritis patients. We used diffusion-weighted MRI (DWI) as a new imaging modality in comparison to standard MRI sequences to study bone marrow oedema, soft-tissue oedema and synovitis in paediatric patients. Methods: A total of 52 patients (mean age 11 ± 5 years) with bone marrow oedema (n = 31), soft-tissue oedema (n = 20) and synovitis (n = 15) were examined with transversal diffusion-weighted single-shot echoplanar imaging in addition to standard MR sequences (T2W TIRM, T1W pre- and post-contrast). Diffusion-weighted images were used for lesion detection and apparent diffusion coefficient (ADC, unit × 10-3 mm2/s) values were measured with ROI technique on ADC maps. Results: In 50 of 52 patients, DWI delineated the lesion of interest corresponding to pathological signal increase on standard sequences. Mean ADC was 1.60 ± 0.14 (range 1.38 - 1.99) in osseous lesions, 1.72 ± 0.31 (range 1.43 - 2.56) in soft tissue oedema and 2.82 ± 0.24 (range 2.47 - 3.18) for joint effusion (ANOVA p<0.001). No significant difference in mean ADC was seen for inflammatory vs. non-inflammatory lesions. Relative signal intensity of oedema was similar for DWI and T2W TIRM. DWI visualised synovial restricted diffusion with a mean ADC of 2.12 ± 0.45 in 12 of 15 patients with synovitis. Conclusions: Diffusion-weighted MRI reliably visualises osseous and soft tissue oedema, as compared to standard sequences. DWI of synovitis is feasible in large joints and presents a novel approach to contrast-free imaging of synovitis. Whole-body DWI for chronic non-bacterial osteomyelitis should be evaluated in future studies.}, subject = {Medizin}, language = {en} } @article{NessBleySchmidtetal.2013, author = {Ness, Thomas and Bley, Thorsten A. and Schmidt, Wolfgang A. and Lamprecht, Peter}, title = {The Diagnosis and Treatment of Giant Cell Arteritis}, series = {Deutsches {\"A}rzteblatt International}, volume = {110}, journal = {Deutsches {\"A}rzteblatt International}, number = {21}, doi = {10.3238/arztebl.2013.0376}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-131676}, pages = {376-86}, year = {2013}, abstract = {Background: Giant cell arteritis (GCA) is the most common systemic vasculitis in persons aged 50 and above (incidence, 3.5 per 100 000 per year). It affects cranial arteries, the aorta, and arteries elsewhere in the body, e.g., in the limbs. Methods: We selectively review the pertinent literature, including guidelines and recommendations from Germany and abroad. Results: The typical symptoms of new-onset GCA are bi-temporal headaches, jaw claudiacation, scalp tenderness, visual disturbances, systemic symptoms such as fever and weight loss, and polymyalgia. The diagnostic assessment comprises laboratory testing (erythrocyte sedimentation rate, C-reactive protein), imaging studies (duplex sonography, high-resolution magnetic resonance imaging, positron-emission tomography), and temporal artery biopsy. The standard treatment is with corticosteroids (adverse effects: diabetes mellitus, osteoporosis, cataract, arterial hypertension). A meta-analysis of three randomized controlled trials led to a recommendation for treatment with methotrexate to lower the recurrence rate and spare steroids. Patients for whom methotrexate is contraindicated or who cannot tolerate the drug can be treated with azathioprine instead. Conclusion: Giant cell arteritis, if untreated, progresses to involve the aorta and its collateral branches, leading to various complications. Late diagnosis and treatment can have serious consequences, including irreversible loss of visual function.}, language = {en} } @article{MuellerKoehlerHendricksetal.2021, author = {M{\"u}ller, Sophie and K{\"o}hler, Franziska and Hendricks, Anne and Kastner, Carolin and B{\"o}rner, Kevin and Diers, Johannes and Lock, Johan F. and Petritsch, Bernhard and Germer, Christoph-Thomas and Wiegering, Armin}, title = {Brain metastases from colorectal cancer: a systematic review of the literature and meta-analysis to establish a guideline for daily treatment}, series = {Cancers}, volume = {13}, journal = {Cancers}, number = {4}, issn = {2072-6694}, doi = {10.3390/cancers13040900}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-228883}, year = {2021}, abstract = {Colorectal cancer (CRC) is the third most common malignancy worldwide. Most patients with metastatic CRC develop liver or lung metastases, while a minority suffer from brain metastases. There is little information available regarding the presentation, treatment, and overall survival of brain metastases (BM) from CRC. This systematic review and meta-analysis includes data collected from three major databases (PubMed, Cochrane, and Embase) based on the key words "brain", "metastas*", "tumor", "colorectal", "cancer", and "malignancy". In total, 1318 articles were identified in the search and 86 studies matched the inclusion criteria. The incidence of BM varied between 0.1\% and 11.5\%. Most patients developed metastases at other sites prior to developing BM. Lung metastases and KRAS mutations were described as risk factors for additional BM. Patients with BM suffered from various symptoms, but up to 96.8\% of BM patients were asymptomatic at the time of BM diagnosis. Median survival time ranged from 2 to 9.6 months, and overall survival (OS) increased up to 41.1 months in patients on a multimodal therapy regimen. Several factors including age, blood levels of carcinoembryonic antigen (CEA), multiple metastases sites, number of brain lesions, and presence of the KRAS mutation were predictors of OS. For BM diagnosis, MRI was considered to be state of the art. Treatment consisted of a combination of surgery, radiation, or systemic treatment.}, language = {en} } @phdthesis{Morche2005, author = {Morche, Susanne}, title = {Single-Voxel- versus Multi-Voxel-Protonen-MR-Spektroskopie bei verschiedenen intrakraniellen L{\"a}sionen}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-12635}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2005}, abstract = {Diese Arbeit untersucht die Fragestellung ob bei der Untersuchung von gesundem Hirngewebe und pathologischen,intrakraniellen L{\"a}sionen mittels Singelvoxel- versus Multivoxel-MR-Protonen-Spektroskopie signifikant unterschiedliche Ergebnisse bestehen. Untersucht wurden Hirntumoren der WHO-Grade 2 bis 4, Metastasen und fokal-entz{\"u}ndliche L{\"a}sionen. Zusammenfassend ist die Unterscheidung zwischen normalem und pathologisch ver{\"a}ndertem Hirngewebe am besten mit der Singelvoxel-Methode und Bildung der CHO/CRE-Ratio m{\"o}glich. Zur Differentialdiagnose und weiteren Malignit{\"a}tseinsch{\"a}tzung eignet sich die Bildung der CHO/NAA-Ratio mit Singelvoxel-Spektroskopie. Weiterhin ist die parallele Anwendung von Singel- und Multivoxel-Spektroskopie empfehlenswert.}, language = {de} } @article{MonteliusLjungbergHornetal.2012, author = {Montelius, Mikael and Ljungberg, Maria and Horn, Michael and Forssell-Aronsson, Eva}, title = {Tumour size measurement in a mouse model using high resolution MRI}, series = {BMC Medical Imaging}, volume = {12}, journal = {BMC Medical Imaging}, number = {12}, doi = {10.1186/1471-2342-12-12}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-124049}, year = {2012}, abstract = {Background Animal models are frequently used to assess new treatment methods in cancer research. MRI offers a non-invasive in vivo monitoring of tumour tissue and thus allows longitudinal measurements of treatment effects, without the need for large cohorts of animals. Tumour size is an important biomarker of the disease development, but to our knowledge, MRI based size measurements have not yet been verified for small tumours (10-2-10-1 g). The aim of this study was to assess the accuracy of MRI based tumour size measurements of small tumours on mice. Methods 2D and 3D T2-weighted RARE images of tumour bearing mice were acquired in vivo using a 7 T dedicated animal MR system. For the 3D images the acquired image resolution was varied. The images were exported to a PC workstation where the tumour mass was determined assuming a density of 1 g/cm3, using an in-house developed tool for segmentation and delineation. The resulting data were compared to the weight of the resected tumours after sacrifice of the animal using regression analysis. Results Strong correlations were demonstrated between MRI- and necropsy determined masses. In general, 3D acquisition was not a prerequisite for high accuracy. However, it was slightly more accurate than 2D when small (<0.2 g) tumours were assessed for inter- and intraobserver variation. In 3D images, the voxel sizes could be increased from 1603 μm3 to 2403 μm3 without affecting the results significantly, thus reducing acquisition time substantially. Conclusions 2D MRI was sufficient for accurate tumour size measurement, except for small tumours (<0.2 g) where 3D acquisition was necessary to reduce interobserver variation. Acquisition times between 15 and 50 minutes, depending on tumour size, were sufficient for accurate tumour volume measurement. Hence, it is possible to include further MR investigations of the tumour, such as tissue perfusion, diffusion or metabolic composition in the same MR session.}, language = {en} } @phdthesis{Moeller2005, author = {Moeller, Richard-Tobias}, title = {Vergleich von Miktionscystourethrographie und niedrig dosierter, kontrastverst{\"a}rkter Miktionsurosonographie mittels Harmonic Imaging zur Diagnostik des vesicoureteralen Refluxes bei Kindern}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-16744}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2005}, abstract = {Zielsetzung: Harmonic Imaging produziert Bilder mit hoher Orts- und Kontrastaufl{\"o}sung. Die Mikrobl{\"a}schen im verwendeten Kontrastmittel werden deutlich sichtbarer. Ziel dieser Studie war es, das diagnostische Potential der kontrastverst{\"a}rkten Miktionsurosonographie (MUS) mittels Harmonic Imaging bei reduzierter Kontrastmitteldosis mit der Miktionszystourethrographie (MCU) zu vergleichen. Material und Methodik: 55 Patienten (17 Jungen, 38 M{\"a}dchen; Durchschnittsalter 4 Jahre), die zur Refuxuntersuchung kamen, wurden f{\"u}r die Vergleichsstudie rekrutiert. Im Anschluß an einen Standard-Ultraschall des Harntraktes mit Harmonic Imaging (Sonoline Elegra, Siemens) folgte die Blasenkatheterisierung und die intravesikale Gabe des Ultraschallkontrastmittels Levovist® (300 mg/ml). Anstatt der bei MUS mit konventioneller Ultraschallmodalit{\"a}t verwendeten Menge - 10\% des Blasenvolumens - wurde jetzt nur 5\% Volumen des Kontrastmittels benutzt. Die Sonographie des Harntraktes wurde wiederholt und auch unter Miktion fortgef{\"u}hrt. Es schloss sich ein MCU an. Ergebnisse: Zur Evaluation standen insgesamt 114 Nieren-Ureter-Einheiten (NUE) zur Verf{\"u}gung. In 29 NUE wurde mit einer oder beiden Methoden ein vesikoureteraler Reflux (VUR) diagnostiziert. In 7 NUE wurde der Reflux nur mit Hilfe der MUS, in 3 NUE nur mittels MCU diagnostiziert. Beim Vergleich der MUS mit der Referenzmethode MCU waren die diagnostischen Ergebnisse folgendermaßen: 86,4\% Sensitivit{\"a}t, 92,4\% Spezifit{\"a}t, 73,1\% positiver Vorhersagewert und 96,6\% negativer Vorhersagewert. Der Korrelationskoeffizient zwischen den beiden Methoden betrug 0,741 (p<0,001). Schlußfolgerungen: MUS mit Harmonic Imaging und halbierter Kontrastmitteldosis ist in Bezug auf Ausschluß und Diagnose eines VUR mit der MCU vergleichbar. Die Reduktion der Kontrastmittelmenge schr{\"a}nkt die Aussagef{\"a}higkeit der MUS nicht ein, sondern erm{\"o}glicht bei gleichen Ergebnissen eine kosteng{\"u}nstigere Untersuchung.}, language = {de} } @article{MihatschBeissertPomperetal.2022, author = {Mihatsch, Patrick W. and Beissert, Matthias and Pomper, Martin G. and Bley, Thorsten A. and Seitz, Anna K. and K{\"u}bler, Hubert and Buck, Andreas K. and Rowe, Steven P. and Serfling, Sebastian E. and Hartrampf, Philipp E. and Werner, Rudolf A.}, title = {Changing threshold-based segmentation has no relevant impact on semi-quantification in the context of structured reporting for PSMA-PET/CT}, series = {Cancers}, volume = {14}, journal = {Cancers}, number = {2}, issn = {2072-6694}, doi = {10.3390/cancers14020270}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-254782}, year = {2022}, abstract = {Prostate-specific membrane antigen (PSMA)-directed positron emission tomography/computed tomography (PET/CT) is increasingly utilized for staging of men with prostate cancer (PC). To increase interpretive certainty, the standardized PSMA reporting and data system (RADS) has been proposed. Using PSMA-RADS, we characterized lesions in 18 patients imaged with \(^{18}\)F-PSMA-1007 PET/CT for primary staging and determined the stability of semi-quantitative parameters. Six hundred twenty-three lesions were categorized according to PSMA-RADS and manually segmented. In this context, PSMA-RADS-3A (soft-tissue) or -3B (bone) lesions are defined as being indeterminate for the presence of PC. For PMSA-RADS-4 and -5 lesions; however, PC is highly likely or almost certainly present [with further distinction based on absence (PSMA-RADS-4) or presence (PSMA-RADS-5) of correlative findings on CT]. Standardized uptake values (SUV\(_{max}\), SUV\(_{peak}\), SUV\(_{mean}\)) were recorded, and volumetric parameters [PSMA-derived tumor volume (PSMA-TV); total lesion PSMA (TL-PSMA)] were determined using different maximum intensity thresholds (MIT) (40 vs. 45 vs. 50\%). SUV\(_{max}\) was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories (p ≤ 0.0322). In particular, the clinically challenging PSMA-RADS-3A lesions showed significantly lower SUV\(_{max}\) and SUV\(_{peak}\) compared to the entire PSMA-RADS-4 or -5 cohort (p < 0.0001), while for PSMA-RADS-3B this only applies when compared to the entire PSMA-RADS-5 cohort (p < 0.0001), but not to the PSMA-RADS-4 cohort (SUV\(_{max}\), p = 0.07; SUV\(_{peak}\), p = 0.08). SUV\(_{mean}\) (p = 0.30) and TL-PSMA (p = 0.16) in PSMA-RADS-5 lesions were not influenced by changing the MIT, while PSMA-TV showed significant differences when comparing 40 vs. 50\% MIT (p = 0.0066), which was driven by lymph nodes (p = 0.0239), but not bone lesions (p = 0.15). SUV\(_{max}\) was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories in \(^{18}\)F-PSMA-1007 PET/CT. As such, the latter parameter may assist the interpreting molecular imaging specialist in assigning the correct PSMA-RADS score to sites of disease, thereby increasing diagnostic certainty. In addition, changes of the MIT in PSMA-RADS-5 lesions had no significant impact on SUV\(_{mean}\) and TL-PSMA in contrast to PSMA-TV.}, language = {en} } @phdthesis{Metschke2003, author = {Metschke, Michaela}, title = {Die Wertigkeit der statischen und dynamischen Kernspintomographie in der Beurteilung der Schulter vor und nach Rotatorenmanschetten-Rekonstruktion}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-8987}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2003}, abstract = {Rotatorenmanschettenrupturen stellen ein h{\"a}ufig auftretendes Krankheitsbild in der Bev{\"o}lkerungsgruppe der „{\"U}ber-40-J{\"a}hrigen" dar. Die f{\"u}hrenden Methoden in der Diagnostik der Rotatorenmanschette sind neben der klinischen Untersuchung die Kernspintomographie und die Sonographie. Die Aussagekraft beider Methoden wurde im Rahmen von Untersuchungen an pr{\"a}operativen und postoperativen Patienten verglichen. Die Ergebnisse zeigten eine ausgezeichnete Sensitivit{\"a}t (92,9\%) und Spezifit{\"a}t (84,2\%) der Sonographie in der Erkennung von Rupturen der Rotatorenmanschette, jedoch eine Abnahme der Sensitivit{\"a}t (71,4\%) bei Differenzierung der L{\"a}sionen in partielle und komplette Rupturen. Bei der Beurteilung der postoperativen Rotatorenmanschette blieben kleine L{\"a}sionen aufgrund der Inhomogenit{\"a}t des Echomusters unerkannt, gr{\"o}ßere Rerupturen wurden in allen F{\"a}llen diagnostiziert. Die Treffsicherheit der Kernspintomographie ergab eine Sensitivit{\"a}t von 78.6\% (64,3\% bei Differenzierung, s.o.), eine Spezifit{\"a}t von 89,5\%, wobei die Untersuchungen an einem Niederfeldger{\"a}t (0,2 Tesla) mit im Vergleich zu den in der Schulterdiagnostik standardm{\"a}ßig eingesetzten Kernspintomographen geringerer Aufl{\"o}sung und verminderter Bildqualit{\"a}t durchgef{\"u}hrt wurden. Innerhalb des ersten postoperativen Jahres erschweren Artefakte die Diagnostik der rekonstruierten Rotatorenmanschette, danach erweist sich die Kernspintomographie als ein {\"u}beraus spezifisches Verfahren, mit welchem auch kleine L{\"a}sionen dargestellt werden. Des Weiteren untersucht vorliegende Arbeit anhand von Patienten- und Probandenkollektiven mit rupturierten und intakten Rotatorenmanschetten, inwieweit sich bei unterschiedlichen Ausmaßen von Rotatorenmanschettenrupturen w{\"a}hrend einer passiven oder aktiven Abduktion des Armes eine {\"A}nderung der Biomechanik feststellen l{\"a}ßt. Bei Untersuchungen an einem offenen Kernspintomographen wurden erstmals Verh{\"a}ltnisse geschaffen, welche die aktive und passive Abduktion des Armes ohne und mit Belastung m{\"o}glichst realit{\"a}tsnah simulierten. Die Ergebnisse der dynamischen Untersuchung zeigen, daß Rupturen des M.supraspinatus alleine zu keiner signifikanten Ver{\"a}nderung des Bewegungsablaufs f{\"u}hren. Eine zus{\"a}tzliche Beteiligung des M.infraspinatus dagegen verursachte sowohl im pr{\"a}- als auch im postoperativen Kollektiv eine signifikante Verringerung des Subakromialraumes, bei zus{\"a}tzlicher Belastung in den jeweiligen Abduktionsstellungen zeigte sich keine weitere signifikante Translation. Dies verdeutlicht die Rolle des M.infraspinatus, dessen Funktionsdefizit ein permanentes H{\"o}hertreten des Humeruskopfes zur Folge hat. Anhand vorliegender Ergebnisse besteht kein Hinweis auf die Best{\"a}tigung der These, biomechanische Ver{\"a}nderungen w{\"u}rden zeitlich vor morphologischen Sehnenl{\"a}sionen auftreten. Sowohl in der pr{\"a}operativen Diagnostik als auch in der Beurteilung postoperativer Rotatorenmanschetten besitzt die Kernspintomographie einen herausragenden Stellenwert. Durch die dynamische Untersuchung konnte die oft vernachl{\"a}ssigte Bedeutung des M.infraspinatus hervorgehoben werden, dessen Rekonstruktion bzw. St{\"a}rkung anzustreben ist, bevor es zu einer weiteren St{\"o}rung der Biomechanik kommt. Die dynamische Kernspintomographie stellt somit eine wertvolle Methode zur Untersuchung physiologischer und pathologischer Bewegungsabl{\"a}ufe der Schulter dar.}, language = {de} } @phdthesis{Meinhardt2007, author = {Meinhardt, Alexander}, title = {MRT gesteuerte Punktionen an einem offenen 0,2T Kernspintomographen}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-28024}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2007}, abstract = {Es wurden insgesamt 70 Punktionen durchgef{\"u}hrt. Die Patienten waren zwischen 2 und 83 Jahre alt (Durchschnitt 56J.). Das Punktionssystem bestand aus einer Titan-Koaxialnadel und einer ferromagnetischen Punktionsnadel. Der Vorteil dieses Punktionssystems gegen{\"u}ber einem reinen Titansystem ist die h{\"o}here Qualit{\"a}t der Punktionszylinder. Ein Nachteil ist, dass die Punktion außerhalb des MRT-Systems erfolgen muss. Ewa 50\% der MRT-gesteuerten Punktionen entfielen auf die Leber. Knochenpunktionen wurden in 21\% der Punktionen durchgef{\"u}hrt. Hierzu wurde ein Knochenbiopsieset mit Bohrer benutzt. Die {\"u}brigen Punktionen verteilten sich auf Thorax, den Abdominalraum ohne Leber sowie den Kopf/Hals Bereich. Die technische Erfolgsrate lag bei 96\%, in drei F{\"a}llen war das gewonnene Material nicht repr{\"a}sentativ, die Sensitivit{\"a}t bestimmte sich mit 88\% bei einer Spezifit{\"a}t von 100\%. Diese Ergebnisse liegen in der Gr{\"o}ßenordnung CT- und Ultraschallgesteuerter Punktionen. Ber{\"u}cksichtigt werden muss in diesem Zusammenhang die Tatsache, dass die Indikation zu MRT-gesteuerten Punktionen sich in den meisten F{\"a}llen aus der fehlenden Visualisierung der Herdbefunde im CT bzw. der komplexen anatomische Lage ableitete. Hinsichtlich der Komplikationen sind die Ergebnisse vorliegender Studie mit denen CT gesteuerter Punktionen vergleichbar, hier liegt die in der Literatur beschriebene Komplikationsrate CT gesteuerter Punktionen zwischen 1\% und 3\%. In dem vorliegenden Kollektiv trat lediglich eine konservativ zu beherrschende Blutung bei einer mediastinalen Punktion auf. Vergleicht man die Anzahl richtig positiver Histologien mit denen falsch negativer hinsichtlich der Dauer der Intervention, der Visualisierbarkeit der L{\"a}sionen gegeben als der Kontrastunterschied der L{\"a}sion zum Umgebungsrauschen (Kontrast/Rausch Verh{\"a}ltnis) sowie hinsichtlich des Kriteriums einer Doppel- oder Einfachangulierung, so zeigten sich keine signifikanten Unterschiede, was erwartungsgem{\"a}ß in der geringen Anzahl falsch negativer Befunde begr{\"u}ndet ist. Urs{\"a}chlich f{\"u}r falsch negative Befunde waren vielmehr der geringe Durchmesser der L{\"a}sionen (4 Herdbefunde < 3 cm) sowie Punktionen im Randbereich maligner L{\"a}sionen (N=2).}, subject = {NMR-Tomographie}, language = {de} } @phdthesis{Mehling2007, author = {Mehling, Christina Adelheid}, title = {Schmerz- und Angsterleben bei Mammographie mit Fremd- und Eigenkompression}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-22997}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2007}, abstract = {Studien der letzten Jahre haben gezeigt, dass viele Frauen aufgrund von Schmerzen bzw. aufgrund der Angst vor Schmerzen w{\"a}hrend der Mammographie diese Kebsvorsorgeuntersuchung nicht wahrnahmen. Die vorliegende Arbeit sollte folgende Fragen kl{\"a}ren: Empfinden Frauen bei der Brustkompression w{\"a}hrend der Mammographie weniger Schmerzen wenn sie ihre Br{\"u}ste selbst komprimieren, als bei Kompression durch eine MTA? Sind Frauen nach Eigenkompression zufriedener mit der gesamten Mammographie, als Frauen mit Fremdkompression, und inwieweit wirkt sich diese Zufriedenheit auf die Bereitschaft aus, wieder eine Mammographie durchf{\"u}hren zu lassen? Durch diese Studie sollte ein neuer Wege aufgezeigt werden, Frauen die Mammographie so angenehm wie m{\"o}glich zu gestalten, um dadurch positiven Einfluss auf ihr Verhalten dieser wichtigen Vorsorgeuntersuchung gegen{\"u}ber nehmen zu k{\"o}nnen. Untersucht wurden 200 Patientinnen, die der radiologischen Abteilung der Frauenklinik der Universit{\"a}t W{\"u}rzburg zur Durchf{\"u}hrung einer Mammographie zugewiesen worden waren. Es erfolgte die Erhebung der generellen und situativen {\"A}ngstlichkeit mittels State-Trait-Angstinventar (STAI), sowie der individuellen Kontroll{\"u}berzeugungen mittels Fragebogen zur Erhebung von Kontroll{\"u}berzeugungen zu Krankheit und Gesundheit (KKG). Nach der Mammographie beantworteten die Frauen nochmals einen Fragebogen, der ihre Zufriedenheit mit der Mammographie, sowie die dabei empfundenen Schmerzen und die Bereitschaft in zwei Jahren wieder an einem Screening durch Mammographie teilzunehmen, erfasste. Die Ergebnisse der Arbeit lassen sich folgender Maßen zusammenfassen: Es zeigte sich eine Korrelation zwischen der situativen {\"A}ngstlichkeit und den bei der Untersuchung empfundenen Schmerzen. Außerdem zeigte sich, je geringer die situationsgebundene Angst der Frauen war, desto zufriedener waren sie auch mit der Untersuchung. Es konnte kein Zusammenhang zwischen der Kontroll{\"u}berzeugung und der Zufriedenheit mit der Mammographie nachweisen werden, weder bei Fremdkompression, noch bei Eigenkompression. Auch mit dem bei der Kompression empfundenen Schmerz konnte bei keiner Kontroll{\"u}berzeugung ein Zusammenhang hergestellt werden. Bez{\"u}glich der Kompression selbst wurde festgestellt, dass Patientinnen der Experimentalgruppe bei der Kompression mehr Kraft anwandten als Patientinnen der Kontrollgruppe und damit ihre Br{\"u}ste flacher komprimierten. Die Mehrheit beider Gruppen war mit der Mammographie zufrieden und gaben an, wieder an einer Mammographie in zwei Jahren teilnehmen zu wollen. Allerdings waren Frauen, die ihre Br{\"u}ste selber komprimierten generell zufriedener mit ihrer Untersuchung und empfanden weniger Schmerzen w{\"a}hrend der Kompression. Der Zusammenhang, dass Frauen eine erneute Teilnahme an einer Mammographie als umso wahrscheinlicher ansahen, je zufriedener sie mit der aktuellen Untersuchung waren, konnte ebenfalls best{\"a}tigt werden.}, language = {de} } @phdthesis{Manger2013, author = {Manger, Sabine}, title = {Der W{\"u}rzburger Schockraumalgorithmus beim polytraumatisierten Kind - eine retrospektive Analyse der Jahre 2004 bis 2009}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-94293}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2013}, abstract = {Seit M{\"a}rz 2004 ist im Zentrum f{\"u}r operative Medizin der Universit{\"a}tsklinik W{\"u}rzburg der Schockraum mit einem Somatom Sensation 16 der Firma Siemens, einem CT mit Sliding-Gantry in Betrieb. Auch schwer verletzte Kinder werden hier nach dem W{\"u}rzburger Schockraumalgorithmus behandelt. Insgesamt gibt es nur wenige Daten zur Anwendung von GK-CT bei Kindern. Die DGU beschreibt im TraumaRegister die Daten von zuletzt 266 Kliniken. Nur 5,1 \% dieser Daten stammen von Kindern unter 16 Jahren. Die Unterschiede zu Erwachsenen entstehen durch die geringere Erfahrung im Straßenverkehr, die kindliche Anatomie, die gr{\"o}ßere Gef{\"a}hrdung durch den hypovol{\"a}mischen Schock und die bessere Rekonvaleszenz von Kindern. Ebenso ist die radiologische Diagnostik durch das geringere K{\"o}rpervolumen und die h{\"o}here Strahlenempfindlichkeit der Kinder problematischer. Der Schockraumalgorithmus der Universit{\"a}tsklinik W{\"u}rzburg besteht aus der Reanimations-, CT- und Versorgungsphase. Die Indikation zur GK-CT wird nach dem Triage-Schema gestellt und ist auch bei polytraumatisierten Kindern Diagnostik der Wahl. Die Schwere der Verletzungen wird mit dem ISS bestimmt. In den Jahren 2004 bis 2009 wurden 72 Kinder mit Verdacht auf ein Polytrauma behandelt. Davon erhielten 57 (79,2\%) ein GK-CT, 15 (20,1 \%) erhielten eine organbezogene CT (CCT, Thorax, Abdomen). 15 (26,3 \%) der 57 Kinder mit GK-CT hatten retrospektiv kein Polytrauma (ISS < 16), wobei hier von einer Overtriage auszugehen ist. Die Kinder wurden haupts{\"a}chlich im Straßenverkehr und hier als Beifahrer eines PKWs verletzt, gefolgt von den Radfahrern und Fußg{\"a}ngern, die von einem PKW erfasst wurden. Ein Drittel der Patienten erlitt Sturzverletzungen aus bis zu f{\"u}nf Metern H{\"o}he. Die am h{\"a}ufigsten verletzte K{\"o}rperregion war mit 52,8 \% der Kopf, gefolgt vom Thorax, den Extremit{\"a}ten und 25 \% Gesichtsverletzungen. Dies ist durch die ung{\"u}nstigere K{\"o}rper-Kopf-Relation der Kinder erkl{\"a}rbar. Im Vergleich zu Erwachsenen ist bei Kindern vermehrt das Gesicht, der Hals und die untere Extremit{\"a}t verletzt, die Wirbels{\"a}ule war weniger betroffen. 82 \% der Kinder wurden maschinell beatmet, davon 65\% initial und 14\% in der ZNA. Es wird empfohlen, Kinder fr{\"u}hzeitig zu intubieren, was sich in der Intubationsrate von 82\% widerspiegelt. Eine Notfalloperation wurde in 38,9 \% der F{\"a}lle durchgef{\"u}hrt, wobei es sich haupts{\"a}chlich um Frakturrepositionen handelte, vor allem bei Kindern mit ISS < 16. Bei Kindern mit ISS ≥ 16 wurde in 8,8 \% der F{\"a}lle eine Kraniotomie durchgef{\"u}hrt. Insgesamt wurden 62 \% der Kinder operiert, wobei es sich auch bei den Operationen im Verlauf haupts{\"a}chlich um Frakturrepositionen handelte. 15 Kinder erhielten kein GK-CT als prim{\"a}re Diagnostik, obwohl dies retrospektiv gem{\"a}ß des Triage-Schemas indiziert gewesen w{\"a}re. Bei diesen Kindern wurden zus{\"a}tzlich zum CCT selektive CTs, R{\"o}ntgenaufnahmen und Abdomenultraschalluntersuchungen durchgef{\"u}hrt. Bei sechs Kindern wurde trotz initialer GK-CT eine therapierelevante Diagnose erst im Verlauf des Klinikaufenthalts gestellt. Dabei handelte es sich um eine Sch{\"a}delbasis-, eine Orbitaboden-, eine Klavikula-, eine Talusfraktur, ein Mesenterialarterieneinriss und eine Ileumruptur. Ein Kind verstarb, weil dessen Ileumruptur in der radiologischen Diagnostik nicht detektiert wurde und die Zeit bis zur Laparotomie verz{\"o}gerte. W{\"a}hrend des Krankenhausaufenthalts wurde zur Verlaufsdokumentation die R{\"o}ntgenuntersuchung, gefolgt von der Sonographie, am h{\"a}ufigsten angewendet. Die CT tritt hierbei in den Hintergrund, wobei die MRT h{\"a}ufiger durchgef{\"u}hrt wurde als bei der initialen Diagnostik. Die Strahlenbelastung des p{\"a}diatrischen Kollektivs ist im Kontext der schnellen Diagnoseerhebung therapierelevanter Verletzungen zu sehen. Bei der GK-CT ist mit einem durchschnittlichen DLP von 2268 mGy•cm, bei der CCT von 956 mGy•cm zu rechnen. Bei den R{\"o}ntgenuntersuchungen ein DFP von 4 cGy•cm2 bei Thoraxr{\"o}ntgenuntersuchungen und 11 cGy•cm2 bei anderen R{\"o}ntgenuntersuchungen. Zur korrekten Einordnung der Strahlendosis sind genauere Richtwerte f{\"u}r Kinder und genauere Protokolle n{\"o}tig. Die GK-CT ist Methode der Wahl bei polytraumatisierten Kindern und wird nur in seltenen F{\"a}llen von der FAST oder der R{\"o}ntgenuntersuchung ersetzt. Trotz der GK-CT k{\"o}nnen nicht alle therapierelevanten Diagnosen gestellt werden. Insgesamt verbrachten die Kinder durchschnittlich 17 Tage im Krankenhaus und sieben Tage auf der Intensivstation. 77,8 \% konnten danach nach Hause entlassen werden, sieben Kinder mussten nach dem Krankenhausaufenthalt in eine Rehabilitationsklinik verlegt werden. Die Letalit{\"a}t der Kinder ist mit 10,5\% (n=6) im Vergleich zu den Erwachsenen mit 13,5 \% und anderen Studien mit einer p{\"a}diatrischen Letalit{\"a}t mit durchschnittlich 18 \% geringer. Vier Kinder verstarben an schwerem SHT, ein Kind in Folge seines schweren Thoraxtraumas und ein Kind entwickelte eine Sepsis in Folge einer in der radiologischen Diagnostik nicht detektierbaren Ileumruptur. Die radiologische Diagnostik des kindlichen Polytraumas hat sich durch das MSCT in den letzten Jahren stark gewandelt. Die geringe Letalit{\"a}t unseres Patientenkollektivs ist ein deutlicher Hinweis auf die Effizienz des W{\"u}rzburger Schockraumalgorithmus auch beim p{\"a}diatrischen Polytrauma.}, subject = {Polytrauma}, language = {de} } @phdthesis{Maier2003, author = {Maier, Stefanie}, title = {Flußgeschwindigkeitsmessungen an Schlauchmodellen : Einfluß eines Echosignalverst{\"a}rkers auf die Meßergebnisse von drei verschiedenen Farbduplexger{\"a}ten}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-8852}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2003}, abstract = {Die farbkodierte Duplexsonographie (FKDS) hat sich als nichtinvasive Methode zur Darstellung des Blutflußes innerhalb von Gef{\"a}ßen sowie von Gef{\"a}ßver{\"a}nderungen etabliert. W{\"a}hrend gute Ergebnisse der Farbduplexsonographie in großen Gef{\"a}ßen {\"u}ber 0,51 mm vorliegen, konnte in einer Modellstudie an kleinen Gef{\"a}ßen unter 0,51 mm festgestellt werden, daß die FKDS in kleineren Gef{\"a}ßen systematisch zu niedrig mißt. Mit Hilfe des gepr{\"u}ften Echosignalverst{\"a}rkers kann dieser systematische Fehler nicht behoben werden. Der Einsatz des Echosignalverst{\"a}rkers bewirkt grunds{\"a}tzlich nur eine geringe Zunahme der gemessenen Flußgeschwindigkeit. Dies ist unabh{\"a}ngig von dem Ger{\"a}tetyp und der Schlauchgr{\"o}ße. Der maximale Effekt wird nach 10 bis 60 Sekunden erreicht. Die Messungen der drei Farbdopplerger{\"a}te QAD 1 (Firma Philips/Quantum), SONOLINE Elegra (Firma Siemens) und HDI 3000 (Firma Philips/ATL) unterscheiden sich in ihrer Auswertung signifikant. Die Ursache der großen Messdifferenzen unter den Ger{\"a}te ist endg{\"u}ltig nicht gekl{\"a}rt. Wahrscheinlich liegt die Ursache in der internen Signalverarbeitung der Farbduplexger{\"a}te.}, language = {de} } @phdthesis{Machann2008, author = {Machann, Wolfram}, title = {MRT nach Myokardinfarkt - Wandfunktionsanalyse und metabolische Bildgebung}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-28457}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2008}, abstract = {Die kardiale MRT konnte in dieser Arbeit f{\"u}r die Infarktdiagnostik und Therapiekontrolle erfolgreich eingesetzt werden. Auf Grund einer Vielzahl von Sequenztechniken, dem Vorteil der Nichtinvasivit{\"a}t und dem Fehlen von ionisierenden Strahlen hat sich die MRT zu einem wichtigen Diagnostikwerkzeug zur Bestimmung von Prognoseparametern bei kardialen Erkrankungen entwickelt.}, subject = {NMR-Tomographie}, language = {de} } @article{LuetkensGrunzKunzetal.2023, author = {Luetkens, Karsten Sebastian and Grunz, Jan-Peter and Kunz, Andreas Steven and Huflage, Henner and Weißenberger, Manuel and Hartung, Viktor and Patzer, Theresa Sophie and Gruschwitz, Philipp and Erg{\"u}n, S{\"u}leyman and Bley, Thorsten Alexander and Feldle, Philipp}, title = {Ultra-high-resolution photon-counting detector CT arthrography of the ankle: a feasibility study}, series = {Diagnostics}, volume = {13}, journal = {Diagnostics}, number = {13}, issn = {2075-4418}, doi = {10.3390/diagnostics13132201}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-362622}, year = {2023}, abstract = {This study was designed to investigate the image quality of ultra-high-resolution ankle arthrography employing a photon-counting detector CT. Bilateral arthrograms were acquired in four cadaveric specimens with full-dose (10 mGy) and low-dose (3 mGy) scan protocols. Three convolution kernels with different spatial frequencies were utilized for image reconstruction (ρ\(_{50}\); Br98: 39.0, Br84: 22.6, Br76: 16.5 lp/cm). Seven radiologists subjectively assessed the image quality regarding the depiction of bone, hyaline cartilage, and ligaments. An additional quantitative assessment comprised the measurement of noise and the computation of contrast-to-noise ratios (CNR). While an optimal depiction of bone tissue was achieved with the ultra-sharp Br98 kernel (S ≤ 0.043), the visualization of cartilage improved with lower modulation transfer functions at each dose level (p ≤ 0.014). The interrater reliability ranged from good to excellent for all assessed tissues (intraclass correlation coefficient ≥ 0.805). The noise levels in subcutaneous fat decreased with reduced spatial frequency (p \< 0.001). Notably, the low-dose Br76 matched the CNR of the full-dose Br84 (p 0.999) and superseded Br98 (p \< 0.001) in all tissues. Based on the reported results, a photon-counting detector CT arthrography of the ankle with an ultra-high-resolution collimation offers stellar image quality and tissue assessability, improving the evaluation of miniscule anatomical structures. While bone depiction was superior in combination with an ultra-sharp convolution kernel, soft tissue evaluation benefited from employing a lower spatial frequency.}, language = {en} } @article{LuetkensErguenHuflageetal.2021, author = {Luetkens, Karsten Sebastian and Erg{\"u}n, S{\"u}leyman and Huflage, Henner and Kunz, Andreas Steven and Gietzen, Carsten Herbert and Conrads, Nora and Pennig, Lenhard and Goertz, Lukas and Bley, Thorsten Alexander and Gassenmaier, Tobias and Grunz, Jan-Peter}, title = {Dose reduction potential in cone-beam CT imaging of upper extremity joints with a twin robotic x-ray system}, series = {Scientific Reports}, volume = {11}, journal = {Scientific Reports}, number = {1}, doi = {10.1038/s41598-021-99748-1}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-270429}, year = {2021}, abstract = {Cone-beam computed tomography is a powerful tool for 3D imaging of the appendicular skeleton, facilitating detailed visualization of bone microarchitecture. This study evaluated various combinations of acquisition and reconstruction parameters for the cone-beam CT mode of a twin robotic x-ray system in cadaveric wrist and elbow scans, aiming to define the best possible trade-off between image quality and radiation dose. Images were acquired with different combinations of tube voltage and tube current-time product, resulting in five scan protocols with varying volume CT dose indices: full-dose (FD; 17.4 mGy), low-dose (LD; 4.5 mGy), ultra-low-dose (ULD; 1.15 mGy), modulated low-dose (mLD; 0.6 mGy) and modulated ultra-low-dose (mULD; 0.29 mGy). Each set of projection data was reconstructed with three convolution kernels (very sharp [Ur77], sharp [Br69], intermediate [Br62]). Five radiologists subjectively assessed the image quality of cortical bone, cancellous bone and soft tissue using seven-point scales. Irrespective of the reconstruction kernel, overall image quality of every FD, LD and ULD scan was deemed suitable for diagnostic use in contrast to mLD (very sharp/sharp/intermediate: 60/55/70\%) and mULD (0/3/5\%). Superior depiction of cortical and cancellous bone was achieved in FD\(_{Ur77}\) and LD\(_{Ur77}\) examinations (p < 0.001) with LD\(_{Ur77}\) scans also providing favorable bone visualization compared to FD\(_{Br69}\) and FD\(_{Br62}\) (p < 0.001). Fleiss' kappa was 0.618 (0.594-0.641; p < 0.001), indicating substantial interrater reliability. In this study, we demonstrate that considerable dose reduction can be realized while maintaining diagnostic image quality in upper extremity joint scans with the cone-beam CT mode of a twin robotic x-ray system. Application of sharper convolution kernels for image reconstruction facilitates superior display of bone microarchitecture.}, language = {en} } @phdthesis{Lucius2023, author = {Lucius, Leonie Johanna}, title = {Die endovaskul{\"a}re Therapie der malignen unteren Einflussstauung mit dem Sinus-XL® Stent}, doi = {10.25972/OPUS-32669}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-326691}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2023}, abstract = {Die interventionelle Radiologie hat sich in den letzten Jahrzehnten zunehmend auf palliativmedizinische sowie onkologische Bereiche ausgeweitet und kann durch minimal-invasive Therapieoptionen gerade in vulnerablen Patientenkollektiven attraktive Behandlungsm{\"o}glichkeiten zur Verf{\"u}gung stellen. Die tumorbedingte untere Einflussstauung ist ein seltenes Krankheitsbild und stellt eine schwere symptomatische Komplikation einer malignen Grunderkrankung dar. Dabei kommt es im Rahmen dieser Grunderkrankung durch die Prim{\"a}rtumormasse oder Metastasen zu extrinsischer Kompression der Vena cava inferior (VCI), Gef{\"a}ßinvasion oder Thrombusbildung. Ziel der Dissertationsarbeit ist es, den technischen und klinischen Erfolg der Sinus-XL ® Stentimplantation in die Vena cava inferior bei einer tumorbedingten unteren Einflussstauung zu untersuchen. Als technischer Erfolg wurde dabei die problemlose Stentimplantation mit anschließender Aufhebung der VCI-Stenose/Okklusion und Revaskularisation der VCI definiert. Bez{\"u}glich des klinischen Erfolges wurde der Frage nachgegangen, inwieweit die Stentimplantation die typischen Symptome einer unteren Einflussstauung ({\"O}deme der unteren Extremit{\"a}t, Aszites und Anasarka) lindern und bestenfalls eliminieren kann. In der vorliegenden Arbeit sind dazu retrospektiv die Daten von insgesamt 21 Patienten (11 Frauen, 10 M{\"a}nner) mit einem medianen Alter von 61 Jahren (19-92 Jahre), die zwischen Oktober 2010 und Januar 2021 aufgrund einer tumorbedingten unteren Einflussstauung mit einem Sinus-XL ® Stent endovaskul{\"a}r versorgt wurden, ausgewertet worden. Zur Quantifizierung der klinischen Symptomatik wurde f{\"u}r das jeweilige Symptom ein Scoring-System entwickelt bzw. modifiziert. Der technische Erfolg belief sich auf 100\% (21/21). Postinterventionell konnte zudem eine signifikante Reduktion des transstenotischen Druckgradienten (p = 0,008) und eine signifikante Aufweitung des Stenosendiameters (p < 0,001) erreicht werden. Die prim{\"a}re und prim{\"a}r-assistierte Stentoffenheit betrug 92,9 \% (13/14) und 100\% (14/14), die anatomische Stentoffenheit (< 50\% Restenose) belief sich auf 53,3 \% (8/15). Die Reinterventionsrate lag bei 4,8 \% (1/21). Schwerwiegende Komplikationen traten nicht auf. Der klinische Erfolg bez{\"u}glich der {\"O}deme der unteren Extremit{\"a}t belief sich auf 82,4 \% (14/17), 93,8 \% (15/16) sowie auf 85,7 \% (18/21) und zeigte in allen betrachteten Zeitintervallen eine signifikante Scorewertreduktion (p < 0,001). Das klinische Outcome bez{\"u}glich der {\"O}deme war bei k{\"u}rzeren Stenosen/Obstruktionen signifikant besser (p = 0,025). Bez{\"u}glich einer intrahepatischen Segmentbeteiligung, der transstenotischen Druckgradienten, der absoluten Gradientenreduktion sowie der {\"U}berlebenszeit nach der Intervention zeigten sich hingegen keine als klinisch relevant einzustufende Ergebnisse. Ein eindeutiger Effekt der Intervention auf die Symptome Anasarka und Aszites konnte nicht nachgewiesen werden. Diesbez{\"u}glich zeigten sich klinische Erfolgsraten von 42,9 \% (6/14) und 5,3 \% (1/19). Im postinterventionellen Verlauf konnten außerdem signifikante Reduktionen der pr{\"a}interventionellen Harnstoffwerte sowie des K{\"o}rpergewichtes der Patienten verzeichnet werden. Zusammenfassend zeigt die vorliegende Arbeit, dass die Sinus-XL ® Stentimplantation geeignet ist, eine tumorbedingte Vena cava inferior-Stenose/Obstruktion aufzuheben und eine Revaskularisation der VCI zu erreichen. Die klinischen Symptome einer unteren Einflussstauung - insbesondere bezogen auf die {\"O}deme der unteren Extremit{\"a}t und mit Einschr{\"a}nkungen bezogen auf die Symptome Aszites und Anasarka - k{\"o}nnen ebenfalls durch die Stentimplantation gelindert und teilweise sogar langanhaltend eliminiert werden. Die Sinus-XL ® Stentimplantation sollte daher stets als Therapieoption bei tumorbedingten unteren Einflussstauungen in Erw{\"a}gung gezogen werden. Nicht zuletzt stellt die Stentimplantation auch eine sichere und komplikationsarme Intervention dar. Weitere Studien, bestenfalls multizentrische Studien, sind jedoch notwendig, um die dargestellten Ergebnisse weiter zu untermauern.}, subject = {Vena cava inferior}, language = {de} }