@article{WernerSolnesJavadietal.2018, author = {Werner, Rudolf and Solnes, Lilja and Javadi, Mehrbod and Weich, Alexander and Gorin, Michael and Pienta, Kenneth and Higuchi, Takahiro and Buck, Andreas and Pomper, Martin and Rowe, Steven and Lapa, Constantin}, title = {SSTR-RADS Version 1.0 as a Reporting System for SSTR-PET Imaging and Selection of Potential PRRT Candidates: A Proposed Standardization Framework}, series = {Journal of Nuclear Medicine}, journal = {Journal of Nuclear Medicine}, issn = {0161-5505}, doi = {10.2967/jnumed.117.206631}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-161298}, year = {2018}, abstract = {Reliable standards and criteria for somatostatin receptor (SSTR) positron emission tomography (PET) are still lacking. We herein propose a structured reporting system on a 5-point scale for SSTR-PET imaging, titled SSTR-RADS version 1.0, which might serve as a standardized assessment for both diagnosis and treatment planning in neuroendocrine tumors (NET). SSTR-RADS could guide the imaging specialist in interpreting SSTR-PET scans, facilitate communication with the referring clinician so that appropriate work-up for equivocal findings is pursued, and serve as a reliable tool for patient selection for planned Peptide Receptor Radionuclide Therapy.}, subject = {Standardisierung}, language = {en} } @inproceedings{SchlosserJarschelDuellietal.2010, author = {Schlosser, Daniel and Jarschel, Michael and Duelli, Michael and Hoßfeld, Tobias and Hoffmann, Klaus and Hoffmann, Marco and Morper, Hans Jochen and Jurca, Dan and Khan, Ashiq}, title = {A Use Case Driven Approach to Network Virtualization}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-55611}, year = {2010}, abstract = {In today's Internet, services are very different in their requirements on the underlying transport network. In the future, this diversity will increase and it will be more difficult to accommodate all services in a single network. A possible approach to cope with this diversity within future networks is the introduction of support for running isolated networks for different services on top of a single shared physical substrate. This would also enable easy network management and ensure an economically sound operation. End-customers will readily adopt this approach as it enables new and innovative services without being expensive. In order to arrive at a concept that enables this kind of network, it needs to be designed around and constantly checked against realistic use cases. In this contribution, we present three use cases for future networks. We describe functional blocks of a virtual network architecture, which are necessary to support these use cases within the network. Furthermore, we discuss the interfaces needed between the functional blocks and consider standardization issues that arise in order to achieve a global consistent control and management structure of virtual networks.}, subject = {Virtualisierung}, language = {en} } @phdthesis{Mehls2002, author = {Mehls, Hagen}, title = {Versuch einer Standardisierung der Exhalatkondensation}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-5892}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2002}, abstract = {Versuch einer Standardisierung der Exhalationskondensation Die Atemkondensatmessung ist eine ein nichtinvasives Verfahren zur Sammlung von Material aus den unteren Atemwegen, welches in den letzten Jahren immer mehr Beachtung gefunden hat. Mit dieser Methode k{\"o}nnen nicht fl{\"u}chtige Subastanzen wie Entz{\"u}ndungsmediatoren, DNA-Sequenzen oder Tumormarker analysiert werden. Die Sammlung von Atemkonsat wird durch ein spezielles konstruiertes Rohr (Eco Screen, Firma J{\"a}ger, W{\"u}rzburg, Deutschland), in dem die exhalierte Luft gefroren wird, m{\"o}glich. Das Ziel der Studie war herauszufinden, ob sich das Volumen oder die Proteinmenge des Atemkondendats durch die Inhalation von Kochsalz (3 \%) steigern l{\"a}ßt und ob sich die gemessenen Werte von Rauchern und Nichtrauchern unterscheiden. Es wurden Kondensatproben von 30 gesunden Probanden {\"u}ber verschiedene Zeitr{\"a}ume (5 bis 15 min) gemessen, im ersten Duchgang ohne, im zweiten Durchgang mit Kochsalzinhalation. Wir fanden eine eine strenge Korrelation der Atemzeit (und dem geatmeten Volumen) mit dem gemessenen Atemkondensatvolumen (r = 0,99, p = 0,0004). Nach der Inhalation von Kochsalz fand sich keine signifikante Steigerung der Kondensatmenge. In einer zweiten Versuchsreihe wurde {\"u}ber einen Zeitraum von 15 Minuten das Kondensat von 10 Rauchern und 20 Nichtrauchern an 3 aufeinanderfolgenden Tagen bez{\"u}glich Volumen und Proteinmenge gemessen. Hier fand sich kein signifikanter Unterschied zwischen Rauchern und Nichtrauchern, eine Korrelation zwischen Kondensatvolumen und Proteinmenge fand sich ebenfalls nicht. Die Tag-zu-Tag-Variabilit{\"a}t war nicht signifikant. Wir schlußfolgern, daß das Atemkondensatvolumen von der Atemzeit und dem hierbei geatmeten Luftvolumen abh{\"a}ngt, es ist nicht notwendig vor Beginn der Messung zur Steigerung der Probenmenge Kochsalz zu inhalieren. Rauchen hat keinen Einfluß auf das Kondensatvolumen und die Proteinmenge des Atemkondensats.}, language = {de} }