@article{WeidemannMaierStoerketal.2016, author = {Weidemann, Frank and Maier, Sebastian K. G. and St{\"o}rk, Stefan and Brunner, Thomas and Liu, Dan and Hu, Kai and Seydelmann, Nora and Schneider, Andreas and Becher, Jan and Canan-K{\"u}hl, Sima and Blaschke, Daniela and Bijnens, Bart and Ertl, Georg and Wanner, Christoph and Nordbeck, Peter}, title = {Usefulness of an implantable loop recorder to detect clinically relevant arrhythmias in patients with advanced fabry cardiomyopathy}, series = {The American Journal of Cardiology}, volume = {118}, journal = {The American Journal of Cardiology}, number = {2}, doi = {10.1016/j.amjcard.2016.04.033}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-188093}, pages = {264-274}, year = {2016}, abstract = {Patients with genetic cardiomyopathy that involves myocardial hypertrophy often develop clinically relevant arrhythmias that increase the risk of sudden death. Consequently, guidelines for medical device therapy were established for hypertrophic cardiomyopathy, but not for conditions with only anecdotal evidence of arrhythmias, like Fabry cardiomyopathy. Patients with Fabry cardiomyopathy progressively develop myocardial fibrosis, and sudden cardiac death occurs regularly. Because 24-hour Holier electrocardiograms (ECGs) might not detect clinically important arrhythmias, we tested an implanted loop recorder for continuous heart rhythm surveillance and determined its impact on therapy. This prospective study included 16 patients (12 men) with advanced Fabry cardiomyopathy, relevant hypertrophy, and replacement fibrosis in "loco typico." No patients previously exhibited clinically relevant arrhythmias on Holier ECGs. Patients received an implantable loop recorder and were prospectively followed with telemedicine for a median of 1.2 years (range 0.3 to 2.0 years). The primary end point was a clinically meaningful event, which required a therapy change, captured with the loop recorder. Patients submitted data regularly (14 +/- 11 times per month). During follow-up, 21 events were detected (including 4 asystole, i.e., ECG pauses >= 3 seconds) and 7 bradycardia events; 5 episodes of intermittent atrial fibrillation (>3 minutes) and 5 episodes of ventricular tachycardia (3 sustained and 2 nonsustained). Subsequently, as defined in the primary end point, 15 events leaded to a change of therapy. These patients required therapy with a pacemaker or cardioverter defibrillator implantation and/or anticoagulation therapy for atrial fibrillation. In conclusion, clinically relevant arrhythmias that require further device and/or medical therapy are often missed with Holier ECGs in patients with advanced stage Fabry cardiomyopathy, but they can be detected by telemonitoring with an implantable loop recorder.}, language = {en} } @article{LendersWeidemannKurschatetal.2016, author = {Lenders, Malte and Weidemann, Frank and Kurschat, Christine and Canaan-K{\"u}hl, Sima and Duning, Thomas and Stypmann, J{\"o}rg and Schmitz, Boris and Reiermann, Stefanie and Kr{\"a}mer, Johannes and Blaschke, Daniela and Wanner, Christoph and Brand, Stefan-Martin and Brand, Eva}, title = {Alpha-Galactosidase A p.A143T, a non-Fabry disease-causing variant}, series = {Orphanet Journal of Rare Diseases}, volume = {11}, journal = {Orphanet Journal of Rare Diseases}, number = {54}, doi = {10.1186/s13023-016-0441-z}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-166559}, year = {2016}, abstract = {Background Fabry disease (FD) is an X-linked multisystemic disorder with a heterogeneous phenotype. Especially atypical or late-onset type 2 phenotypes present a therapeutical dilemma. Methods To determine the clinical impact of the alpha-Galactosidase A (GLA) p.A143T/ c.427G > A variation, we retrospectively analyzed 25 p.A143T patients in comparison to 58 FD patients with other missense mutations. Results p.A143T patients suffering from stroke/ transient ischemic attacks had slightly decreased residual GLA activities, and/or increased lyso-Gb3 levels, suspecting FD. However, most male p.A143T patients presented with significant residual GLA activity (~50 \% of reference), which was associated with normal lyso-Gb3 levels. Additionally, p.A143T patients showed less severe FD-typical symptoms and absent FD-typical renal and cardiac involvement in comparison to FD patients with other missense mutations. Two tested female p.A143T patients with stroke/TIA did not show skewed X chromosome inactivation. No accumulation of neurologic events in family members of p.A143T patients with stroke/transient ischemic attacks was observed. Conclusions We conclude that GLA p.A143T seems to be most likely a neutral variant or a possible modifier instead of a disease-causing mutation. Therefore, we suggest that p.A143T patients with stroke/transient ischemic attacks of unknown etiology should be further evaluated, since the diagnosis of FD is not probable and subsequent ERT or chaperone treatment should not be an unreflected option.}, language = {en} }