@inproceedings{WernerMarcusSheikhbahaeietal.2018, author = {Werner, Rudolf A. and Marcus, Charles and Sheikhbahaei, Sara and Higuchi, Takahiro and Solnes, Lilja B. and Rowe, Steven P. and Buck, Andreas K. and Lapa, Constantin and Javadi, Mehrbod S.}, title = {Diagnostic Accuracy of Visual Assessment of an Initial DaT-Scan in Comparison to a Fully Automatic Semiquantitative Method}, series = {Journal of Nuclear Medicine}, volume = {59}, booktitle = {Journal of Nuclear Medicine}, number = {Supplement No. 1}, issn = {0161-5505}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-162208}, pages = {626}, year = {2018}, abstract = {No abstract available.}, subject = {Parkinson-Krankheit}, language = {en} } @inproceedings{WernerMarcusSheikhbahaeietal.2018, author = {Werner, Rudolf A. and Marcus, Charles and Sheikhbahaei, Sara and Higuchi, Takahiro and Solnes, Lilja B. and Rowe, Steven P. and Buck, Andreas K. and Lapa, Constantin and Javadi, Mehrbod S.}, title = {The Impact of Ageing on Dopamine Transporter Imaging}, series = {Journal of Nuclear Medicine}, volume = {59}, booktitle = {Journal of Nuclear Medicine}, number = {Supplement No 1}, issn = {0161-5505}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-162213}, pages = {1646}, year = {2018}, abstract = {No abstract available.}, subject = {Parkinson-Krankheit}, language = {en} } @unpublished{WernerIlhanLehneretal.2018, author = {Werner, Rudolf A. and Ilhan, Harun and Lehner, Sebastian and Papp, L{\´a}szl{\´o} and Zs{\´o}t{\´e}r, Norbert and Schatka, Imke and Muegge, Dirk O. and Javadi, Mehrbod S. and Higuchi, Takahiro and Buck, Andreas K. and Bartenstein, Peter and Bengel, Frank and Essler, Markus and Lapa, Constantin and Bundschuh, Ralph A.}, title = {Pre-therapy Somatostatin-Receptor-Based Heterogeneity Predicts Overall Survival in Pancreatic Neuroendocrine Tumor Patients Undergoing Peptide Receptor Radionuclide Therapy}, series = {Molecular Imaging and Biology}, journal = {Molecular Imaging and Biology}, issn = {1536-1632}, doi = {https://doi.org/10.1007/s11307-018-1252-5}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-164624}, year = {2018}, abstract = {Purpose: Early identification of aggressive disease could improve decision-support in pancreatic neuroendocrine tumor (pNET) patients prior to peptide receptor radionuclide therapy (PRRT). The prognostic value of intratumoral textural features (TF) determined by baseline somatostatin receptor (SSTR)-PET before PRRT was analyzed. Procedures: 31 patients with G1/G2 pNET were enrolled (G2, n=23/31). Prior to PRRT with [\(^{177}\)Lu]DOTATATE (mean, 3.6 cycles), baseline SSTR-PET/CT was performed. By segmentation of 162 (median per patient, 5) metastases, intratumoral TF were computed. The impact of conventional PET parameters (SUV\(_{mean/max}\)), imaging-based TF as well as clinical parameters (Ki67, CgA) for prediction of both progression-free (PFS) and overall survival (OS) after PRRT was evaluated. Results: Within a median follow-up of 3.7y, tumor progression was detected in 21 patients (median, 1.5y) and 13/31 deceased (median, 1.9y). In ROC analysis, the TF Entropy, reflecting derangement on a voxel-by-voxel level, demonstrated predictive capability for OS (cutoff=6.7, AUC=0.71, p=0.02). Of note, increasing Entropy could predict a longer survival (>6.7, OS=2.5y, 17/31), whereas less voxel-based derangement portended inferior outcome (<6.7, OS=1.9y, 14/31). These findings were supported in a G2 subanalysis (>6.9, OS=2.8y, 9/23 vs. <6.9, OS=1.9y, 14/23). Kaplan-Meier analysis revealed a significant distinction between high- and low-risk groups using Entropy (n=31, p<0.05). For those patients below the ROC-derived threshold, the relative risk of death after PRRT was 2.73 (n=31, p=0.04). Ki67 was negatively associated with PFS (p=0.002); however, SUVmean/max failed in prognostication (n.s.). Conclusions: In contrast to conventional PET parameters, assessment of intratumoral heterogeneity demonstrated superior prognostic performance in pNET patients undergoing PRRT. This novel PET-based strategy of outcome prediction prior to PRRT might be useful for patient risk stratification.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @inproceedings{WernerHiguchiMueggeetal.2017, author = {Werner, Rudolf and Higuchi, Takahiro and Muegge, Dirk and Javadi, Mehrbod S. and M{\"a}rkl, Bruno and Aulmann, Christoph and Buck, Andreas K. and Fassnacht, Martin and Lapa, Constantin and Kreissl, Michael C.}, title = {Predictive value of FDG-PET in patients with advanced medullary thyroid cancer undergoing vandetanib treatment}, series = {Journal of Nuclear Medicine}, volume = {58}, booktitle = {Journal of Nuclear Medicine}, number = {no. supplement 1}, issn = {0161-5505}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-161147}, pages = {169}, year = {2017}, abstract = {Introduction: The prognosis of medullary thyroid carcinoma (MTC) is poor using common chemotherapeutic approaches. However, during the last years encouraging results of recently introduced tyrosine kinase inhibitors (TKI) such as vandetanib have been published. In this study we aimed to correlate the results of \(^{18}\)F-fluorodeoxyglucose ([\(^{18}\)F]FDG) positron emission tomography (PET) imaging with treatment outcome. Methods: Eighteen patients after thyroidectomy with recurrent/advanced MTC lesions receiving vandetanib (300 mg orally/day) could be analysed. A baseline \(^{18}\)F-FDG PET prior to and a follow-up \(^{18}\)F-FDG PET 3 months after TKI initiation were performed. During follow-up, tumor progression was assessed every 3 months including computed tomography according to RECIST. Progression-free survival (PFS) was correlated with the maximum standardized uptake value of \(^{18}\)F-FDG in lymph nodes (SUV(LN)max) or visceral metastases (SUV(MTS)max) as well as with clinical parameters using ROC analysis. Results: Within median 3.6 years of follow-up, 9 patients showed disease progression at median 8.5 months after TKI initiation. An elevated glucose consumption assessed by baseline \(^{18}\)F-FDG PET (SUV(LN)max > 7.25) could predict a shorter PFS (2 y) with an accuracy of 76.5\% (SUV(LN)max <7.25, 4.3 y; p=0.03). Accordingly, preserved tumor metabolism in the follow-up PET (SUV(MTS)max >2.7) also demonstrated an unfavorable prognosis (accuracy, 85.7\%). On the other hand, none of the clinical parameters reached significance in response prediction. Conclusions: In patients with advanced and progressive MTC, tumors with higher metabolic activity at baseline are more aggressive and more prone to progression as reflected by a shorter PFS; they should be monitored more closely. Preserved glucose consumption 3 months after treatment initiation was also related to poorer prognosis.}, language = {en} } @unpublished{WernerBundschuhBundschuhetal.2019, author = {Werner, Rudolf A. and Bundschuh, Ralph A. and Bundschuh, Lena and Fanti, Stefano and Javadi, Mehrbod S. and Higuchi, Takahiro and Weich, A. and Pienta, Kenneth J. and Buck, Andreas K. and Pomper, Martin G. and Gorin, Michael A. and Herrmann, Ken and Lapa, Constantin and Rowe, Steven P.}, title = {Novel Structured Reporting Systems for Theranostic Radiotracers}, series = {Journal of Nuclear Medicine}, journal = {Journal of Nuclear Medicine}, issn = {0161-5505}, doi = {10.2967/jnumed.118.223537}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-174629}, year = {2019}, abstract = {Standardized reporting is more and more routinely implemented in clinical practice and such structured reports have a major impact on a large variety of medical fields, e.g. laboratory medicine, pathology, and, recently, radiology. Notably, the field of nuclear medicine is constantly evolving, as novel radiotracers for numerous clinical applications are developed. Thus, framework systems for standardized reporting in this field may a) increase clinical acceptance of new radiotracers, b) allow for inter- and intra-center comparisons for quality assurance, and c) may be used in (global) multi-center studies to ensure comparable results and enable efficient data abstraction. In the last two years, several standardized framework systems for positron emission tomography (PET) radiotracers with potential theranostic applications have been proposed. These include systems for prostate-specific membrane antigen (PSMA)-targeted PET agents for the diagnosis and treatment of prostate cancer (PCa) and somatostatin receptor (SSTR)-targeted PET agents for the diagnosis and treatment of neuroendocrine neoplasias. In the present review, those standardized framework systems for PSMA- and SSTR-targeted PET will be briefly introduced followed by an overview of their advantages and limitations. In addition, potential applications will be defined, approaches to validate such concepts will be proposed, and future perspectives will be discussed.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @unpublished{WernerBundschuhBundschuhetal.2018, author = {Werner, Rudolf A. and Bundschuh, Ralph A. and Bundschuh, Lena and Javadi, Mehrbod S. and Leal, Jeffrey P. and Higuchi, Takahiro and Pienta, Kenneth J. and Buck, Andreas K. and Pomper, Martin G. and Gorin, Michael A. and Lapa, Constantin and Rowe, Steven P.}, title = {Interobserver Agreement for the Standardized Reporting System PSMA-RADS 1.0 on \(^{18}\)F-DCFPyL PET/CT Imaging}, series = {Journal of Nuclear Medicine}, journal = {Journal of Nuclear Medicine}, issn = {0161-5505}, doi = {10.2967/jnumed.118.217588}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-167788}, year = {2018}, abstract = {Objectives: Recently, the standardized reporting and data system for prostate-specific membrane antigen (PSMA)-targeted positron emission tomography (PET) imaging studies, termed PSMA-RADS version 1.0, was introduced. We aimed to determine the interobserver agreement for applying PSMA-RADS to imaging interpretation of 18F-DCFPyL PET examinations in a prospective setting mimicking the typical clinical work-flow at a prostate cancer referral center. Methods: Four readers (two experienced readers (ER, > 3 years of PSMA-targeted PET interpretation experience) and two inexperienced readers (IR, < 1 year of experience)), who had all read the initial publication on PSMA-RADS 1.0, assessed 50 18F-DCFPyL PET/computed tomography (CT) studies independently. Per scan, a maximum of 5 target lesions were selected by the observers and a PSMA-RADS score for every target lesion was recorded. No specific pre-existing conditions were placed on the selection of the target lesions, although PSMA-RADS 1.0 suggests that readers focus on the most highly avid or largest lesions. An overall scan impression based on PSMA-RADS was indicated and interobserver agreement rates on a target lesion-based, on an organ-based, and on an overall PSMA-RADS score-based level were computed. Results: The number of target lesions identified by each observer were as follows: ER 1, 123; ER 2, 134; IR 1, 123; and IR 2, 120. Among those selected target lesions, 125 were chosen by at least two individual observers (all four readers selected the same target lesion in 58/125 (46.4\%) instances, three readers in 40/125 (32\%) and two observers in 27/125 (21.6\%) instances). The interobserver agreement for PSMA-RADS scoring among identical target lesions was good (intraclass correlation coefficient (ICC) for four, three and two identical target lesions, ≥0.60, respectively). For lymph nodes, an excellent interobserver agreement was derived (ICC=0.79). The interobserver agreement for an overall scan impression based on PSMA-RADS was also excellent (ICC=0.84), with a significant difference for ER (ICC=0.97) vs. IR (ICC=0.74, P=0.005). Conclusions: PSMA-RADS demonstrates a high concordance rate in this study, even among readers with different levels of experience. This suggests that PSMA-RADS can be effectively used for communication with clinicians and can be implemented in the collection of data for large prospective trials.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{WernerWeichHiguchietal.2017, author = {Werner, Rudolf A. and Weich, Alexander and Higuchi, Takahiro and Schmid, Jan S. and Schirbel, Andreas and Lassmann, Michael and Wild, Vanessa and Rudelius, Martina and Kudlich, Theodor and Herrmann, Ken and Scheurlen, Michael and Buck, Andreas K. and Kropf, Saskia and Wester, Hans-J{\"u}rgen and Lapa, Constantin}, title = {Imaging of Chemokine Receptor 4 Expression in Neuroendocrine Tumors - a Triple Tracer Comparative Approach}, series = {Theranostics}, volume = {7}, journal = {Theranostics}, number = {6}, doi = {10.7150/thno.18754}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-158008}, pages = {1489-1498}, year = {2017}, abstract = {C-X-C motif chemokine receptor 4 (CXCR4) and somatostatin receptors (SSTR) are overexpressed in gastro-entero-pancreatic neuroendocrine tumors (GEP-NET). In this study, we aimed to elucidate the feasibility of non-invasive CXCR4 positron emission tomography/computed tomography (PET/CT) imaging in GEP-NET patients using [\(^{68}\)Ga]Pentixafor in comparison to \(^{68}\)Ga-DOTA-D-Phe-Tyr3-octreotide ([\(^{68}\)Ga]DOTATOC) and \(^{18}\)F-fluorodeoxyglucose ([\(^{18}\)F]FDG). Twelve patients with histologically proven GEP-NET (3xG1, 4xG2, 5xG3) underwent [\(^{68}\)Ga]DOTATOC, [\(^{18}\)F]FDG, and [\(^{68}\)Ga]Pentixafor PET/CT for staging and planning of the therapeutic management. Scans were analyzed on a patient as well as on a lesion basis and compared to immunohistochemical staining patterns of CXCR4 and somatostatin receptors SSTR2a and SSTR5. [\(^{68}\)Ga]Pentixafor visualized tumor lesions in 6/12 subjects, whereas [\(^{18}\)F]FDG revealed sites of disease in 10/12 and [\(^{68}\)Ga]DOTATOC in 11/12 patients, respectively. Regarding sensitivity, SSTR-directed PET was the superior imaging modality in all G1 and G2 NET. CXCR4-directed PET was negative in all G1 NET. In contrast, 50\% of G2 and 80\% of G3 patients exhibited [\(^{68}\)Ga]Pentixafor-positive tumor lesions. Whereas CXCR4 seems to play only a limited role in detecting well-differentiated NET, increasing receptor expression could be non-invasively observed with increasing tumor grade. Thus, [\(^{68}\)Ga]Pentixafor PET/CT might serve as non-invasive read-out for evaluating the possibility of CXCR4-directed endoradiotherapy in advanced dedifferentiated SSTR-negative tumors.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{WernerBeykanHiguchietal.2016, author = {Werner, Rudolf A. and Beykan, Seval and Higuchi, Takahiro and L{\"u}ckerath, Katharina and Weich, Alexander and Scheurlen, Michael and Bluemel, Christina and Herrmann, Ken and Buck, Andreas K. and Lassmann, Michael and Lapa, Constantin and H{\"a}nscheid, Heribert}, title = {The impact of \(^{177}\)Lu-octreotide therapy on \(^{99m}\)Tc-MAG3 clearance is not predictive for late nephropathy}, series = {Oncotarget}, volume = {7}, journal = {Oncotarget}, number = {27}, doi = {10.18632/oncotarget.9775}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-177318}, pages = {41233-41241}, year = {2016}, abstract = {Peptide Receptor Radionuclide Therapy (PRRT) for the treatment of neuroendocrine tumors may lead to kidney deterioration. This study aimed to evaluate the suitability of \(^{99m}\)Tc-mercaptoacetyltriglycine (\(^{99m}\)Tc-MAG3) clearance for the early detection of PRRT-induced changes on tubular extraction (TE). TE rate (TER) was measured prior to 128 PRRT cycles (7.6±0.4 GBq \(^{177}\)Lu-octreotate/octreotide each) in 32 patients. TER reduction during PRRT was corrected for age-related decrease and analyzed for the potential to predict loss of glomerular filtration (GF). The GF rate (GFR) as measure for renal function was derived from serum creatinine. The mean TER was 234 ± 53 ml/min/1.73 m² before PRRT (baseline) and 221 ± 45 ml/min/1.73 m² after a median follow-up of 370 days. The age-corrected decrease (mean: -3\%, range: -27\% to +19\%) did not reach significance (p=0.09) but significantly correlated with the baseline TER (Spearman p=-0.62, p<0.001). Patients with low baseline TER showed an improved TER after PRRT, high decreases were only observed in individuals with high baseline TER. Pre-therapeutic TER data were inferior to plasma creatinine-derived GFR estimates in predicting late nephropathy. TER assessed by \(^{99m}\)Tc-MAG3­clearance prior to and during PRRT is not suitable as early predictor of renal injury and an increased risk for late nephropathy.}, language = {en} } @article{WeichWernerBucketal.2021, author = {Weich, Alexander and Werner, Rudolf A. and Buck, Andreas K. and Hartrampf, Philipp E. and Serfling, Sebastian E. and Scheurlen, Michael and Wester, Hans-J{\"u}rgen and Meining, Alexander and Kircher, Stefan and Higuchi, Takahiro and Pomper, Martin G. and Rowe, Steven P. and Lapa, Constantin and Kircher, Malte}, title = {CXCR4-Directed PET/CT in Patients with Newly Diagnosed Neuroendocrine Carcinomas}, series = {Diagnostics}, volume = {11}, journal = {Diagnostics}, number = {4}, issn = {2075-4418}, doi = {10.3390/diagnostics11040605}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-234231}, year = {2021}, abstract = {We aimed to elucidate the diagnostic potential of the C-X-C motif chemokine receptor 4 (CXCR4)-directed positron emission tomography (PET) tracer \(^{68}\)Ga-Pentixafor in patients with poorly differentiated neuroendocrine carcinomas (NEC), relative to the established reference standard \(^{18}\)F-FDG PET/computed tomography (CT). In our database, we retrospectively identified 11 treatment-na{\"i}ve patients with histologically proven NEC, who underwent \(^{18}\)F-FDG and CXCR4-directed PET/CT for staging and therapy planning. The images were analyzed on a per-patient and per-lesion basis and compared to immunohistochemical staining (IHC) of CXCR4 from PET-guided biopsies. \(^{68}\)Ga-Pentixafor visualized tumor lesions in 10/11 subjects, while \(^{18}\)F-FDG revealed sites of disease in all 11 patients. Although weak to moderate CXCR4 expression could be corroborated by IHC in 10/11 cases, \(^{18}\)F-FDG PET/CT detected significantly more tumor lesions (102 vs. 42; total lesions, n = 107; p < 0.001). Semi-quantitative analysis revealed markedly higher 18F-FDG uptake as compared to \(^{68}\)Ga-Pentixafor (maximum and mean standardized uptake values (SUV) and tumor-to-background ratios (TBR) of cancerous lesions, SUVmax: 12.8 ± 9.8 vs. 5.2 ± 3.7; SUVmean: 7.4 ± 5.4 vs. 3.1 ± 3.2, p < 0.001; and, TBR 7.2 ± 7.9 vs. 3.4 ± 3.0, p < 0.001). Non-invasive imaging of CXCR4 expression in NEC is inferior to the reference standard \(^{18}\)F-FDG PET/CT.}, language = {en} } @article{KosmalaSerflingDreheretal.2022, author = {Kosmala, Aleksander and Serfling, Sebastian E. and Dreher, Niklas and Lindner, Thomas and Schirbel, Andreas and Lapa, Constantin and Higuchi, Takahiro and Buck, Andreas K. and Weich, Alexander and Werner, Rudolf A.}, title = {Associations between normal organs and tumor burden in patients imaged with fibroblast activation protein inhibitor-directed positron emission tomography}, series = {Cancers}, volume = {14}, journal = {Cancers}, number = {11}, issn = {2072-6694}, doi = {10.3390/cancers14112609}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-275154}, year = {2022}, abstract = {(1) Background: We aimed to quantitatively investigate [\(^{68}\)Ga]Ga-FAPI-04 uptake in normal organs and to assess a relationship with the extent of FAPI-avid tumor burden. (2) Methods: In this single-center retrospective analysis, thirty-four patients with solid cancers underwent a total of 40 [\(^{68}\)Ga]Ga-FAPI-04 PET/CT scans. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were established by placing volumes of interest (VOIs) in the heart, liver, spleen, pancreas, kidneys, and bone marrow. Total tumor burden was determined by manual segmentation of tumor lesions with increased uptake. For tumor burden, quantitative assessment included maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA = TV × SUV\(_{mean}\)). Associations between uptake in normal organs and tumor burden were investigated by applying Spearman's rank correlation coefficient. (3) Results: Median SUV\(_{mean}\) values were 2.15 in the pancreas (range, 1.05-9.91), 1.42 in the right (range, 0.57-3.06) and 1.41 in the left kidney (range, 0.73-2.97), 1.2 in the heart (range, 0.46-2.59), 0.86 in the spleen (range, 0.55-1.58), 0.65 in the liver (range, 0.31-2.11), and 0.57 in the bone marrow (range, 0.26-0.94). We observed a trend towards significance for uptake in the myocardium and tumor-derived SUV\(_{max}\) (ρ = 0.29, p = 0.07) and TV (ρ = -0.30, p = 0.06). No significant correlation was achieved for any of the other organs: SUV\(_{max}\) (ρ ≤ 0.1, p ≥ 0.42), TV (ρ ≤ 0.11, p ≥ 0.43), and FTA (ρ ≤ 0.14, p ≥ 0.38). In a sub-analysis exclusively investigating patients with high tumor burden, significant correlations of myocardial uptake with tumor SUV\(_{max}\) (ρ = 0.44; p = 0.03) and tumor-derived FTA with liver uptake (ρ = 0.47; p = 0.02) were recorded. (4) Conclusions: In this proof-of-concept study, quantification of [\(^{68}\)Ga]Ga-FAPI-04 PET showed no significant correlation between normal organs and tumor burden, except for a trend in the myocardium. Those preliminary findings may trigger future studies to determine possible implications for treatment with radioactive FAP-targeted drugs, as higher tumor load or uptake may not lead to decreased doses in the majority of normal organs.}, language = {en} } @article{WernerSheikhbahaeiJonesetal.2017, author = {Werner, Rudolf A. and Sheikhbahaei, Sara and Jones, Krystyna M. and Javadi, Mehrbod S. and Solnes, Lilja B. and Ross, Ashley E. and Allaf, Mohamad E. and Pienta, Kenneth J. and Lapa, Constantin and Buck, Andreas K. and Higuchi, Takahiro and Pomper, Martin G. and Gorin, Micheal A. and Rowe, Steven P.}, title = {Patterns of uptake of prostate-specific membrane antigen (PSMA)-targeted \(^{18}\)F-DCFPyL in peripheral ganglia}, series = {Annals of Nuclear Medicine}, volume = {31}, journal = {Annals of Nuclear Medicine}, number = {9}, issn = {0914-7187}, doi = {10.1007/s12149-017-1201-4}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-166971}, pages = {696-702}, year = {2017}, abstract = {Objective: Radiotracers targeting prostate-specific membrane antigen (PSMA) have increasingly been recognized as showing uptake in a number of normal structures, anatomic variants, and non-prostate-cancer pathologies. We aimed to explore the frequency and degree of uptake in peripheral ganglia in patients undergoing PET with the PSMA-targeted agent \(^{18}\)F-DCFPyL. Methods: A total of 98 patients who underwent \(^{18}\)F-DCFPyL PET/CT imaging were retrospectively analyzed. This included 76 men with prostate cancer (PCa) and 22 patients with renal cell carcinoma (RCC; 13 men, 9 women). Scans were evaluated for uptake in the cervical, stellate, celiac, lumbar and sacral ganglia. Maximum standardized uptake value corrected to body weight (SUV\(_{max}\)), and maximum standardized uptake value corrected to lean body mass (SUL\(_{max}\)) were recorded for all ganglia with visible uptake above background. Ganglia-to-background ratios were calculated by dividing the SUV\(_{max}\) and SUL\(_{max}\) values by the mean uptake in the ascending aorta (Aortamean) and the right gluteus muscle (Gluteusmean). Results: Overall, 95 of 98 (96.9\%) patients demonstrated uptake in at least one of the evaluated peripheral ganglia. With regard to the PCa cohort, the most frequent sites of radiotracer accumulation were lumbar ganglia (55/76, 72.4\%), followed by the cervical ganglia (51/76, 67.1\%). Bilateral uptake was found in the majority of cases [lumbar 44/55 (80\%) and cervical 30/51 (58.8\%)]. Additionally, discernible radiotracer uptake was recorded in 50/76 (65.8\%) of the analyzed stellate ganglia and in 45/76 (59.2\%) of the celiac ganglia, whereas only 5/76 (6.6\%) of the sacral ganglia demonstrated \(^{18}\)F-DCFPyL accumulation. Similar findings were observed for patients with RCC, with the most frequent locations of radiotracer uptake in both the lumbar (20/22, 90.9\%) and cervical ganglia (19/ 22, 86.4\%). No laterality preference was found in mean PSMA-ligand uptake for either the PCa or RCC cohorts. Conclusion: As PSMA-targeted agents become more widely disseminated, the patterns of uptake in structures that are not directly relevant to patients' cancers must be understood. This is the first systematic evaluation of the uptake of \(^{18}\)F-DCFPyL in ganglia demonstrating a general trend with a descending frequency of radiotracer accumulation in lumbar, cervical, stellate, celiac, and sacral ganglia. The underlying biology that leads to variability of PSMA-targeted radiotracers in peripheral ganglia is not currently understood, but may provide opportunities for future research.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @unpublished{WernerAndreeJavadietal.2018, author = {Werner, Rudolf A. and Andree, Christian and Javadi, Mehrbod S. and Lapa, Constantin and Buck, Andreas K. and Higuchi, Takahiro and Pomper, Martin G. and Gorin, Michael A. and Rowe, Steven P. and Pienta, Kenneth J.}, title = {A Voice From the Past: Re-Discovering the Virchow Node with PSMA-targeted \(^{18}\)F-DCFPyL PET Imaging}, series = {Urology - The Gold Journal}, journal = {Urology - The Gold Journal}, issn = {0090-4295}, doi = {10.1016/j.urology.2018.03.030}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-161103}, year = {2018}, abstract = {No abstract available.}, subject = {Virchow Node}, language = {en} } @article{WernerAndreeJavadietal.2018, author = {Werner, Rudolf A. and Andree, Christian and Javadi, Mehrbod S. and Lapa, Constantin and Buck, Andreas K. and Higuchi, Takahiro and Pomper, Martin G. and Gorin, Michael A. and Rowe, Steven P. and Pienta, Kenneth J.}, title = {A Voice From the Past: Re-Discovering the Virchow Node with PSMA-targeted \(^{18}\)F-DCFPyL PET Imaging}, series = {Urology - The Gold Journal}, volume = {117}, journal = {Urology - The Gold Journal}, issn = {0090-4295}, doi = {10.1016/j.urology.2018.03.030}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-164632}, pages = {18-21}, year = {2018}, abstract = {No abstract available.}, language = {en} } @article{EisslerWernerAriasLozaetal.2021, author = {Eissler, Cristoph and Werner, Rudolf A. and Arias-Loza, Paula and Nose, Naoko and Chen, Xinyu and Pomper, Martin G. and Rowe, Steven P. and Lapa, Constantin and Buck, Andreas K. and Higuchi, Takahiro}, title = {The number of frames on ECG-gated \(^{18}\)F-FDG small animal PET has a significant impact on LV systolic and diastolic functional parameters}, series = {Molecular Imaging}, volume = {2021}, journal = {Molecular Imaging}, doi = {10.1155/2021/4629459}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-265778}, year = {2021}, abstract = {Objectives. This study is aimed at investigating the impact of frame numbers in preclinical electrocardiogram- (ECG-) gated \(^{18}\)F-fluorodeoxyglucose (\(^{18}\)F-FDG) positron emission tomography (PET) on systolic and diastolic left ventricular (LV) parameters in rats. Methods. \(^{18}\)F-FDG PET imaging using a dedicated small animal PET system with list mode data acquisition and continuous ECG recording was performed in diabetic and control rats. The list-mode data was sorted and reconstructed with different numbers of frames (4, 8, 12, and 16) per cardiac cycle into tomographic images. Using an automatic ventricular edge detection software, left ventricular (LV) functional parameters, including ejection fraction (EF), end-diastolic (EDV), and end-systolic volume (ESV), were calculated. Diastolic variables (time to peak filling (TPF), first third mean filling rate (1/3 FR), and peak filling rate (PFR)) were also assessed. Results. Significant differences in multiple parameters were observed among the reconstructions with different frames per cardiac cycle. EDV significantly increased by numbers of frames (353.8 \& PLUSMN; 57.7 mu l*, 380.8 \& PLUSMN; 57.2 mu l*, 398.0 \& PLUSMN; 63.1 mu l*, and 444.8 \& PLUSMN; 75.3 mu l at 4, 8, 12, and 16 frames, respectively; *P < 0.0001 vs. 16 frames), while systolic (EF) and diastolic (TPF, 1/3 FR and PFR) parameters were not significantly different between 12 and 16 frames. In addition, significant differences between diabetic and control animals in 1/3 FR and PFR in 16 frames per cardiac cycle were observed (P < 0.005), but not for 4, 8, and 12 frames. Conclusions. Using ECG-gated PET in rats, measurements of cardiac function are significantly affected by the frames per cardiac cycle. Therefore, if you are going to compare those functional parameters, a consistent number of frames should be used.}, language = {en} } @article{WernerIlhanLehneretal.2018, author = {Werner, Rudolf A. and Ilhan, Harun and Lehner, Sebastian and Papp, L{\´a}szl{\´o} and Zs{\´o}t{\´e}r, Norbert and Schatka, Imke and Muegge, Dirk O. and Javadi, Mehrbod S. and Higuchi, Takahiro and Buck, Andreas K. and Bartenstein, Peter and Bengel, Frank and Essler, Markus and Lapa, Constantin and Bundschuh, Ralph A.}, title = {Pre-therapy Somatostatin-Receptor-Based Heterogeneity Predicts Overall Survival in Pancreatic Neuroendocrine Tumor Patients Undergoing Peptide Receptor Radionuclide Therapy}, series = {Molecular Imaging and Biology}, journal = {Molecular Imaging and Biology}, issn = {1536-1632}, doi = {10.1007/s11307-018-1252-5}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-167168}, year = {2018}, abstract = {Purpose: Early identification of aggressive disease could improve decision-support in pancreatic neuroendocrine tumor (pNET) patients prior to peptide receptor radionuclide therapy (PRRT). The prognostic value of intratumoral textural features (TF) determined by baseline somatostatin receptor (SSTR)-PET before PRRT was analyzed. Procedures: 31 patients with G1/G2 pNET were enrolled (G2, n=23/31). Prior to PRRT with [\(^{177}\)Lu]DOTATATE (mean, 3.6 cycles), baseline SSTR-PET/CT was performed. By segmentation of 162 (median per patient, 5) metastases, intratumoral TF were computed. The impact of conventional PET parameters (SUV\(_{mean/max}\)), imaging-based TF as well as clinical parameters (Ki67, CgA) for prediction of both progression-free (PFS) and overall survival (OS) after PRRT was evaluated. Results: Within a median follow-up of 3.7y, tumor progression was detected in 21 patients (median, 1.5y) and 13/31 deceased (median, 1.9y). In ROC analysis, the TF Entropy, reflecting derangement on a voxel-by-voxel level, demonstrated predictive capability for OS (cutoff=6.7, AUC=0.71, p=0.02). Of note, increasing Entropy could predict a longer survival (>6.7, OS=2.5y, 17/31), whereas less voxel-based derangement portended inferior outcome (<6.7, OS=1.9y, 14/31). These findings were supported in a G2 subanalysis (>6.9, OS=2.8y, 9/23 vs. <6.9, OS=1.9y, 14/23). Kaplan-Meier analysis revealed a significant distinction between high- and low-risk groups using Entropy (n=31, p<0.05). For those patients below the ROC-derived threshold, the relative risk of death after PRRT was 2.73 (n=31, p=0.04). Ki67 was negatively associated with PFS (p=0.002); however, SUVmean/max failed in prognostication (n.s.). Conclusions: In contrast to conventional PET parameters, assessment of intratumoral heterogeneity demonstrated superior prognostic performance in pNET patients undergoing PRRT. This novel PET-based strategy of outcome prediction prior to PRRT might be useful for patient risk stratification.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{WernerBundschuhBundschuhetal.2018, author = {Werner, Rudolf A. and Bundschuh, Ralph A. and Bundschuh, Lena and Javadi, Mehrbod S. and Higuchi, Takahiro and Weich, Alexander and Sheikhbahaei, Sara and Pienta, Kenneth J. and Buck, Andreas K. and Pomper, Martin G. and Gorin, Michael A. and Lapa, Constantin and Rowe, Steven P.}, title = {MI-RADS: Molecular Imaging Reporting and Data Systems - A Generalizable Framework for Targeted Radiotracers with Theranostic Implications}, series = {Annals of Nuclear Medicine}, journal = {Annals of Nuclear Medicine}, issn = {0914-7187}, doi = {10.1007/s12149-018-1291-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-166995}, year = {2018}, abstract = {Both prostate-specific membrane antigen (PSMA)- and somatostatin receptor (SSTR)-targeted positron emission tomography (PET) imaging agents for staging and restaging of prostate carcinoma or neuroendocrine tumors, respectively, are seeing rapidly expanding use. In addition to diagnostic applications, both classes of radiotracers can be used to triage patients for theranostic endoradiotherapy. While interpreting PSMA- or SSTR-targeted PET/computed tomography (CT) scans, the reader has to be aware of certain pitfalls. Adding to the complexity of the interpretation of those imaging agents, both normal biodistribution, and also false-positive and -negative findings differ between PSMA- and SSTR-targeted PET radiotracers. Herein summarized under the umbrella term molecular imaging reporting and data systems (MI-RADS), two novel RADS classifications for PSMA- and SSTR-targeted PET imaging are described (PSMA- and SSTR-RADS). Both framework systems may contribute to increase the level of a reader's confidence and to navigate the imaging interpreter through indeterminate lesions, so that appropriate workup for equivocal findings can be pursued. Notably, PSMA- and SSTR-RADS are structured in a reciprocal fashion, i.e. if the reader is familiar with one system, the other system can readily be applied as well. In the present review we will discuss the most common pitfalls on PSMA- and SSTR-targeted PET/CT, briefly introduce PSMA- and SSTR-RADS, and define a future role of the umbrella framework MI-RADS compared to other harmonization systems.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{WernerBundschuhHiguchietal.2018, author = {Werner, Rudolf A. and Bundschuh, Ralph A. and Higuchi, Takahiro and Javadi, Mehrbod S. and Rowe, Steven P. and Zs{\´o}t{\´e}r, Norbert and Kroiss, Matthias and Fassnacht, Martin and Buck, Andreas K. and Kreissl, Michael C. and Lapa, Constantin}, title = {Volumetric and Texture Analysis of Pretherapeutic \(^{18}\)F-FDG PET can Predict Overall Survival in Medullary Thyroid Cancer Patients Treated with Vandetanib}, series = {Endocrine}, journal = {Endocrine}, issn = {1355-008X}, doi = {10.1007/s12020-018-1749-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-167910}, year = {2018}, abstract = {Purpose: The metabolically most active lesion in 2-deoxy-2-(\(^{18}\)F)fluoro-D-glucose (\(^{18}\)F-FDG) PET/CT can predict progression-free survival (PFS) in patients with medullary thyroid carcinoma (MTC) starting treatment with the tyrosine kinase inhibitor (TKI) vandetanib. However, this metric failed in overall survival (OS) prediction. In the present proof of concept study, we aimed to explore the prognostic value of intratumoral textural features (TF) as well as volumetric parameters (total lesion glycolysis, TLG) derived by pre-therapeutic \(^{18}\)F-FDG PET. Methods: Eighteen patients with progressive MTC underwent baseline \(^{18}\)F-FDG PET/CT prior to and 3 months after vandetanib initiation. By manual segmentation of the tumor burden at baseline and follow-up PET, intratumoral TF and TLG were computed. The ability of TLG, imaging-based TF, and clinical parameters (including age, tumor marker doubling times, prior therapies and RET (rearranged during transfection) mutational status) for prediction of both PFS and OS were evaluated. Results: The TF Complexity and the volumetric parameter TLG obtained at baseline prior to TKI initiation successfully differentiated between low- and high-risk patients. Complexity allocated 10/18 patients to the high-risk group with an OS of 3.3y (vs. low-risk group, OS=5.3y, 8/18, AUC=0.78, P=0.03). Baseline TLG designated 11/18 patients to the high-risk group (OS=3.5y vs. low-risk group, OS=5y, 7/18, AUC=0.83, P=0.005). The Hazard Ratio for cancer-related death was 6.1 for Complexity (TLG, 9.5). Among investigated clinical parameters, the age at initiation of TKI treatment reached significance for PFS prediction (P=0.02, OS, n.s.). Conclusions: The TF Complexity and the volumetric parameter TLG are both independent parameters for OS prediction.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{WernerWeichKircheretal.2018, author = {Werner, Rudolf A. and Weich, Alexander and Kircher, Malte and Solnes, Lilja B. and Javadi, Mehrbod S. and Higuchi, Takahiro and Buck, Andreas K. and Pomper, Martin G. and Rowe, Steven and Lapa, Constantin}, title = {The theranostic promise for neuroendocrine tumors in the late 2010s - Where do we stand, where do we go?}, series = {Theranostics}, volume = {8}, journal = {Theranostics}, number = {22}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-170264}, pages = {6088-6100}, year = {2018}, abstract = {More than 25 years after the first peptide receptor radionuclide therapy (PRRT), the concept of somatostatin receptor (SSTR)-directed imaging and therapy for neuroendocrine tumors (NET) is seeing rapidly increasing use. To maximize the full potential of its theranostic promise, efforts in recent years have expanded recommendations in current guidelines and included the evaluation of novel theranostic radiotracers for imaging and treatment of NET. Moreover, the introduction of standardized reporting framework systems may harmonize PET reading, address pitfalls in interpreting SSTR-PET/CT scans and guide the treating physician in selecting PRRT candidates. Notably, the concept of PRRT has also been applied beyond oncology, e.g. for treatment of inflammatory conditions like sarcoidosis. Future perspectives may include the efficacy evaluation of PRRT compared to other common treatment options for NET, novel strategies for closer monitoring of potential side effects, the introduction of novel radiotracers with beneficial pharmacodynamic and kinetic properties or the use of supervised machine learning approaches for outcome prediction. This article reviews how the SSTR-directed theranostic concept is currently applied and also reflects on recent developments that hold promise for the future of theranostics in this context.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{WernerKircherHiguchietal.2019, author = {Werner, Rudolf A. and Kircher, Stefan and Higuchi, Takahiro and Kircher, Malte and Schirbel, Andreas and Wester, Hans-J{\"u}rgen and Buck, Andreas K. and Pomper, Martin G. and Rowe, Steven P. and Lapa, Constantin}, title = {CXCR4-directed imaging in solid tumors}, series = {Frontiers in Oncology}, volume = {9}, journal = {Frontiers in Oncology}, number = {770}, issn = {2234-943X}, doi = {10.3389/fonc.2019.00770}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-195678}, year = {2019}, abstract = {Despite histological evidence in various solid tumor entities, available experience with CXCR4-directed diagnostics and endoradiotherapy mainly focuses on hematologic diseases. With the goal of expanding the application of CXCR4 theranostics to solid tumors, we aimed to elucidate the feasibility of CXCR4-targeted imaging in a variety of such neoplasms. Methods: Nineteen patients with newly diagnosed, treatment-na{\"i}ve solid tumors including pancreatic adenocarcinoma or neuroendocrine tumor, cholangiocarcinoma, hepatocellular carcinoma, renal cell carcinoma, ovarian cancer, and prostate cancer underwent [\(^{68}\)Ga]Pentixafor PET/CT. CXCR4-mediated uptake was assessed both visually and semi-quantitatively by evaluation of maximum standardized uptake values (SUV\(_{max}\)) of both primary tumors and metastases. With physiologic liver uptake as reference, tumor-to-background ratios (TBR) were calculated. [\(^{68}\)Ga]Pentixafor findings were further compared to immunohistochemistry and [\(^{18}\)F]FDG PET/CT. Results: On [\(^{68}\)Ga]Pentixafor PET/CT, 10/19 (52.6\%) primary tumors were visually detectable with a median SUVmax of 5.4 (range, 1.7-16.0) and a median TBR of 2.6 (range, 0.8-7.4), respectively. The highest level of radiotracer uptake was identified in a patient with cholangiocarcinoma (SUVmax, 16.0; TBR, 7.4). The relatively low uptake on [\(^{68}\)Ga]Pentixafor was also noted in metastases, exhibiting a median SUVmax of 4.5 (range, 2.3-8.8; TBR, 1.7; range, 1.0-4.1). A good correlation between uptake on [\(^{68}\)Ga]Pentixafor and histological derived CXCR4 expression was noted (R = 0.62, P < 0.05). In the 3 patients in whom [\(^{18}\)F]FDG PET/CT was available, [\(^{68}\)Ga]Pentixafor exhibited lower uptake in all lesions. Conclusions: In this cohort of newly diagnosed, treatment-na{\"i}ve patients with solid malignancies, CXCR4 expression as detected by [\(^{68}\)Ga]Pentixafor-PET/CT and immunohistochemistry was rather moderate. Thus, CXCR4-directed imaging may not play a major role in the management of solid tumors in the majority of patients.}, language = {en} } @article{WernerDerlinLapaetal.2020, author = {Werner, Rudolf A. and Derlin, Thorsten and Lapa, Constantin and Sheikbahaei, Sara and Higuchi, Takahiro and Giesel, Frederik L. and Behr, Spencer and Drzezga, Alexander and Kimura, Hiroyuki and Buck, Andreas K. and Bengel, Frank M. and Pomper, Martin G. and Gorin, Michael A. and Rowe, Steven P.}, title = {\(^{18}\)F-labeled, PSMA-targeted radiotracers: leveraging the advantages of radiofluorination for prostate cancer molecular imaging}, series = {Theranostics}, volume = {10}, journal = {Theranostics}, number = {1}, issn = {1838-7640}, doi = {10.7150/thno.37894}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-202559}, pages = {1-16}, year = {2020}, abstract = {Prostate-specific membrane antigen (PSMA)-targeted PET imaging for prostate cancer with \(^{68}\)Ga-labeled compounds has rapidly become adopted as part of routine clinical care in many parts of the world. However, recent years have witnessed the start of a shift from \(^{68}\)Ga- to \(^{18}\)F-labeled PSMA-targeted compounds. The latter imaging agents have several key advantages, which may lay the groundwork for an even more widespread adoption into the clinic. First, facilitated delivery from distant suppliers expands the availability of PET radiopharmaceuticals in smaller hospitals operating a PET center but lacking the patient volume to justify an onsite \(^{68}\)Ge/\(^{68}\)Ga generator. Thus, such an approach meets the increasing demand for PSMA-targeted PET imaging in areas with lower population density and may even lead to cost-savings compared to in-house production. Moreover, \(^{18}\)F-labeled radiotracers have a higher positron yield and lower positron energy, which in turn decreases image noise, improves contrast resolution, and maximizes the likelihood of detecting subtle lesions. In addition, the longer half-life of 110 min allows for improved delayed imaging protocols and flexibility in study design, which may further increase diagnostic accuracy. Moreover, such compounds can be distributed to sites which are not allowed to produce radiotracers on-site due to regulatory issues or to centers without access to a cyclotron. In light of these advantageous characteristics, \(^{18}\)F-labeled PSMA-targeted PET radiotracers may play an important role in both optimizing this transformative imaging modality and making it widely available. We have aimed to provide a concise overview of emerging \(^{18}\)F-labeled PSMA-targeted radiotracers undergoing active clinical development. Given the wide array of available radiotracers, comparative studies are needed to firmly establish the role of the available \(^{18}\)F-labeled compounds in the field of molecular PCa imaging, preferably in different clinical scenarios.}, language = {en} }