@article{BuderLapaKreissletal.2014, author = {Buder, Kristina and Lapa, Constantin and Kreissl, Michael C. and Schirbel, Andreas and Herrmann, Ken and Schnack, Alexander and Br{\"o}cker, Eva-Bettina and Goebeler, Matthias and Buck, Andreas K. and Becker, J{\"u}rgen C.}, title = {"Somatostatin receptor expression in Merkel cell carcinoma as target for molecular imaging"}, doi = {10.1186/1471-2407-14-268}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-110326}, year = {2014}, abstract = {Background Merkel cell carcinoma (MCC) is a rare cutaneous neoplasm with increasing incidence, aggressive behavior and poor prognosis. Somatostatin receptors (SSTR) are expressed in MCC and represent a potential target for both imaging and treatment. Methods To non-invasively assess SSTR expression in MCC using PET and the radiotracers [68Ga]DOTA-D-Phe1-Tyr3-octreotide (DOTATOC) or -octreotate (DOTATATE) as surrogate for tumor burden. In 24 patients with histologically proven MCC SSTR-PET was performed and compared to results of computed tomography (CT). Results SSTR-PET detected primary and metastatic MCC lesions. On a patient-based analysis, sensitivity of SSTR-PET was 73\% for nodal metastases, 100\% for bone, and 67\% for soft-tissue metastases, respectively. Notably, brain metastases were initially detected by SSTR-PET in 2 patients, whereas liver and lung metastases were diagnosed exclusively by CT. SSTR-PET showed concordance to CT results in 20 out of 24 patients. Four patients (17\%) were up-staged due to SSTR-PET and patient management was changed in 3 patients (13\%). Conclusion SSTR-PET showed high sensitivity for imaging bone, soft tissue and brain metastases, and particularly in combination with CT had a significant impact on clinical stage and patient management.}, language = {en} } @article{ZhouDierksKertelsetal.2020, author = {Zhou, Xiang and Dierks, Alexander and Kertels, Olivia and Kircher, Malte and Schirbel, Andreas and Samnick, Samuel and Buck, Andreas K. and Knorz, Sebastian and B{\"o}ckle, David and Scheller, Lukas and Messerschmidt, Janin and Barakat, Mohammad and Kort{\"u}m, K. Martin and Rasche, Leo and Einsele, Hermann and Lapa, Constantin}, title = {18F-FDG, 11C-Methionine, and 68Ga-Pentixafor PET/CT in patients with smoldering multiple myeloma: imaging pattern and clinical features}, series = {Cancers}, volume = {12}, journal = {Cancers}, number = {8}, issn = {2072-6694}, doi = {10.3390/cancers12082333}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-211240}, year = {2020}, abstract = {This study aimed to explore the correlation between imaging patterns and clinical features in patients with smoldering multiple myeloma (SMM) who simultaneously underwent 18F-FDG, 11C-Methionine, and 68Ga-Pentixafor positron emission tomography/computed tomography (PET/CT). We retrieved and analyzed clinical characteristics and PET imaging data of 10 patients with SMM. We found a significant correlation between bone marrow (BM) plasma cell (PC) infiltration and mean standardized uptake values (SUV\(_{mean}\)) of lumbar vertebrae L2-L4 on 11C-Methionine PET/CT scans (r = 0.676, p = 0.031) and 68Ga-Pentixafor PET/CT scans (r = 0.839, p = 0.002). However, there was no significant correlation between BM involvement and SUV\(_{mean}\) of lumbar vertebrae L2-L4 on 18F-FDG PET/CT scans (r = 0.558, p = 0.093). Similarly, mean target-to-background ratios (TBR\(_{mean}\)) of lumbar vertebrae L2-L4 also correlated with bone marrow plasma cell (BMPC) infiltration in 11C-Methionine PET/CT (r = 0.789, p = 0.007) and 68Ga-Pentixafor PET/CT (r = 0.724, p = 0.018) PET/CT. In contrast, we did not observe a significant correlation between BMPC infiltration rate and TBR\(_{mean}\) in 18F-FDG PET/CT (r = 0.355, p = 0.313). Additionally, on 11C-Methionine PET/CT scans, we found a significant correlation between BMPC infiltration and TBR\(_{max}\) of lumbar vertebrae L2-L4 (r = 0.642, p = 0.045). In conclusion, 11C-Methionine and 68Ga-Pentixafor PET/CT demonstrate higher sensitivity than 18F-FDG PET/CT in detecting BM involvement in SMM.}, language = {en} } @article{JanssenHoffmannKannoetal.2020, author = {Janssen, Jan P. and Hoffmann, Jan V. and Kanno, Takayuki and Nose, Naoko and Grunz, Jan-Peter and Onoguchi, Masahisa and Chen, Xinyu and Lapa, Constantin and Buck, Andreas K. and Higuchi, Takahiro}, title = {Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging}, series = {Scientific Reports}, volume = {10}, journal = {Scientific Reports}, doi = {10.1038/s41598-020-75696-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-230616}, year = {2020}, abstract = {We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available \(^{99m}\)Tc-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with \(^{99m}\)Tc-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with similar to 100 MBq [\(^{99m}\)TcTc-MIBI or similar to 150 MBq [\(^{99m}\)Tc]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1="very poor" to 5="very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5\%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time.}, language = {en} } @article{MihatschBeissertPomperetal.2022, author = {Mihatsch, Patrick W. and Beissert, Matthias and Pomper, Martin G. and Bley, Thorsten A. and Seitz, Anna K. and K{\"u}bler, Hubert and Buck, Andreas K. and Rowe, Steven P. and Serfling, Sebastian E. and Hartrampf, Philipp E. and Werner, Rudolf A.}, title = {Changing threshold-based segmentation has no relevant impact on semi-quantification in the context of structured reporting for PSMA-PET/CT}, series = {Cancers}, volume = {14}, journal = {Cancers}, number = {2}, issn = {2072-6694}, doi = {10.3390/cancers14020270}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-254782}, year = {2022}, abstract = {Prostate-specific membrane antigen (PSMA)-directed positron emission tomography/computed tomography (PET/CT) is increasingly utilized for staging of men with prostate cancer (PC). To increase interpretive certainty, the standardized PSMA reporting and data system (RADS) has been proposed. Using PSMA-RADS, we characterized lesions in 18 patients imaged with \(^{18}\)F-PSMA-1007 PET/CT for primary staging and determined the stability of semi-quantitative parameters. Six hundred twenty-three lesions were categorized according to PSMA-RADS and manually segmented. In this context, PSMA-RADS-3A (soft-tissue) or -3B (bone) lesions are defined as being indeterminate for the presence of PC. For PMSA-RADS-4 and -5 lesions; however, PC is highly likely or almost certainly present [with further distinction based on absence (PSMA-RADS-4) or presence (PSMA-RADS-5) of correlative findings on CT]. Standardized uptake values (SUV\(_{max}\), SUV\(_{peak}\), SUV\(_{mean}\)) were recorded, and volumetric parameters [PSMA-derived tumor volume (PSMA-TV); total lesion PSMA (TL-PSMA)] were determined using different maximum intensity thresholds (MIT) (40 vs. 45 vs. 50\%). SUV\(_{max}\) was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories (p ≤ 0.0322). In particular, the clinically challenging PSMA-RADS-3A lesions showed significantly lower SUV\(_{max}\) and SUV\(_{peak}\) compared to the entire PSMA-RADS-4 or -5 cohort (p < 0.0001), while for PSMA-RADS-3B this only applies when compared to the entire PSMA-RADS-5 cohort (p < 0.0001), but not to the PSMA-RADS-4 cohort (SUV\(_{max}\), p = 0.07; SUV\(_{peak}\), p = 0.08). SUV\(_{mean}\) (p = 0.30) and TL-PSMA (p = 0.16) in PSMA-RADS-5 lesions were not influenced by changing the MIT, while PSMA-TV showed significant differences when comparing 40 vs. 50\% MIT (p = 0.0066), which was driven by lymph nodes (p = 0.0239), but not bone lesions (p = 0.15). SUV\(_{max}\) was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories in \(^{18}\)F-PSMA-1007 PET/CT. As such, the latter parameter may assist the interpreting molecular imaging specialist in assigning the correct PSMA-RADS score to sites of disease, thereby increasing diagnostic certainty. In addition, changes of the MIT in PSMA-RADS-5 lesions had no significant impact on SUV\(_{mean}\) and TL-PSMA in contrast to PSMA-TV.}, language = {en} } @article{BluemelLinkeHerrmannetal.2016, author = {Bluemel, Christina and Linke, Fraenze and Herrmann, Ken and Simunovic, Iva and Eiber, Matthias and Kestler, Christian and Buck, Andreas K. and Schirbel, Andreas and Bley, Thorsten A. and Wester, Hans-Juergen and Vergho, Daniel and Becker, Axel}, title = {Impact of \(^{68}\)Ga-PSMA PET/CT on salvage radiotherapy planning in patients with prostate cancer and persisting PSA values or biochemical relapse after prostatectomy}, series = {EJNMMI Research}, volume = {6}, journal = {EJNMMI Research}, number = {78}, doi = {10.1186/s13550-016-0233-4}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-147798}, year = {2016}, abstract = {Background Salvage radiotherapy (SRT) is clinically established in prostate cancer (PC) patients with PSA persistence or biochemical relapse (BCR) after prior radical surgery. PET/CT imaging prior to SRT may be performed to localize disease recurrence. The recently introduced \(^{68}\)Ga-PSMA outperforms other PET tracers for detection of recurrence and is therefore expected also to impact radiation planning. Forty-five patients with PSA persistence (16 pts) or BCR (29 pts) after prior prostatectomy, scheduled to undergo SRT of the prostate bed, underwent \(^{68}\)Ga-PSMA PET/CT. The median PSA level was 0.67 ng/ml. The impact of \(^{68}\)Ga-PSMA PET/CT on the treatment decision was assessed. Patients with oligometastatic (≤5 lesions) PC underwent radiotherapy (RT), with the extent of the RT area and dose escalation being based on PET positivity. Results Suspicious lesions were detected in 24/45 (53.3 \%) patients. In 62.5 \% of patients, lesions were only detected by 68Ga-PSMA PET. Treatment was changed in 19/45 (42.2 \%) patients, e.g., extending SRT to metastases (9/19), administering dose escalation in patients with morphological local recurrence (6/19), or replacing SRT by systemic therapy (2/19). 38/45 (84.4 \%) followed the treatment recommendation, with data on clinical follow-up being available in 21 patients treated with SRT. All but one showed biochemical response (mean PSA decline 78 ± 19 \%) within a mean follow-up of 8.12 ± 5.23 months. Conclusions \(^{68}\)Ga-PSMA PET/CT impacts treatment planning in more than 40 \% of patients scheduled to undergo SRT. Future prospective studies are needed to confirm this significant therapeutic impact on patients prior to SRT.}, language = {en} } @article{HoffmannJanssenKannoetal.2020, author = {Hoffmann, Jan V. and Janssen, Jan P. and Kanno, Takayuki and Shibutani, Takayuki and Onoguchi, Masahisa and Lapa, Constantin and Grunz, Jan-Peter and Buck, Andreas K. and Higuchi, Takahiro}, title = {Performance evaluation of fifth-generation ultra-high-resolution SPECT system with two stationary detectors and multi-pinhole imaging}, series = {EJNMMI Physics}, volume = {7}, journal = {EJNMMI Physics}, doi = {10.1186/s40658-020-00335-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-230361}, year = {2020}, abstract = {Background Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. These systems benefit from less labour-intensive maintenance and quality control as fewer prone parts are moving, higher accuracy for focused scans and maintaining high resolution with increased sensitivity due to focused pinholes on the field of view. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT\(^+\)). Methods The new U-SPECT5-E with two stationary detectors was used for acquiring data with \(^{99m}\)Tc-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT\(^+\) for comparison. Results Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT\(^+\). In the visually analysed sections of the reconstructed mini Derenzo phantoms, rods as small as 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M) were resolved. Uniformity for maximum resolution recorded 40.7\% (XUHR-M), 29.1\% (GP-M, U-SPECT5-E), 16.3\% (GP-M, U-SPECT\(^+\)) and 23.0\% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60 to 1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR. Conclusions While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup.}, language = {en} } @article{HartrampfPetritschBucketal.2020, author = {Hartrampf, Philipp E. and Petritsch, Bernhard and Buck, Andreas K. and Serfling, Sebastian E.}, title = {Pitfalls in PSMA-PET/CT: Intensive bone-marrow uptake in a case with polycythaemia vera}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {48}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, issn = {1619-7070}, doi = {10.1007/s00259-020-05072-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-235608}, pages = {1669-1670}, year = {2020}, abstract = {No abstract available.}, language = {en} } @article{LinzBrandsKertelsetal.2021, author = {Linz, Christian and Brands, Roman C. and Kertels, Olivia and Dierks, Alexander and Brumberg, Joachim and Gerhard-Hartmann, Elena and Hartmann, Stefan and Schirbel, Andreas and Serfling, Sebastian and Zhi, Yingjun and Buck, Andreas K. and K{\"u}bler, Alexander and Hohm, Julian and Lapa, Constantin and Kircher, Malte}, title = {Targeting fibroblast activation protein in newly diagnosed squamous cell carcinoma of the oral cavity - initial experience and comparison to [\(^{18}\)F]FDG PET/CT and MRI}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {48}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {12}, issn = {1619-7070}, doi = {10.1007/s00259-021-05422-z}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-307246}, pages = {3951-3960}, year = {2021}, abstract = {Purpose While [\(^{18}\)F]-fluorodeoxyglucose ([\(^{18}\)F]FDG) is the standard for positron emission tomography/computed tomography (PET/CT) imaging of oral squamous cell carcinoma (OSCC), diagnostic specificity is hampered by uptake in inflammatory cells such as neutrophils or macrophages. Recently, molecular imaging probes targeting fibroblast activation protein α (FAP), which is overexpressed in a variety of cancer-associated fibroblasts, have become available and might constitute a feasible alternative to FDG PET/CT. Methods Ten consecutive, treatment-na{\"i}ve patients (8 males, 2 females; mean age, 62 ± 9 years) with biopsy-proven OSCC underwent both whole-body [\(^{18}\)F]FDG and [\(^{68}\)Ga]FAPI-04 (FAP-directed) PET/CT for primary staging prior to tumor resection and cervical lymph node dissection. Detection of the primary tumor, as well as the presence and number of lymph node and distant metastases was analysed. Intensity of tracer accumulation was assessed by means of maximum (SUV\(_{max}\)) and peak (SUV\(_{peak}\) standardized uptake values. Histological work-up including immunohistochemical staining for FAP served as standard of reference. Results [\(^{18}\)F]FDG and FAP-directed PET/CT detected all primary tumors with a SUVmax of 25.5 ± 13.2 (FDG) and 20.5 ± 6.4 (FAP-directed) and a SUVpeak of 16.1 ± 10.3 ([\(^{18}\)F]FDG) and 13.8 ± 3.9 (FAP-directed), respectively. Regarding cervical lymph node metastases, FAP-directed PET/CT demonstrated comparable sensitivity (81.3\% vs. 87.5\%; P = 0.32) and specificity (93.3\% vs. 81.3\%; P = 0.16) to [\(^{18}\)F]FDG PET/CT. FAP expression on the cell surface of cancer-associated fibroblasts in both primary lesions as well as lymph nodes metastases was confirmed in all samples. Conclusion FAP-directed PET/CT in OSCC seems feasible. Future research to investigate its potential to improve patient staging is highly warranted.}, language = {en} } @article{ZhouDierksKertelsetal.2020, author = {Zhou, Xiang and Dierks, Alexander and Kertels, Olivia and Samnick, Samuel and Kircher, Malte and Buck, Andreas K. and Haertle, Larissa and Knorz, Sebastian and B{\"o}ckle, David and Scheller, Lukas and Messerschmidt, Janin and Barakat, Mohammad and Truger, Marietta and Haferlach, Claudia and Einsele, Hermann and Rasche, Leo and Kort{\"u}m, K. Martin and Lapa, Constantin}, title = {The link between cytogenetics/genomics and imaging patterns of relapse and progression in patients with relapsed/refractory multiple myeloma: a pilot study utilizing 18F-FDG PET/CT}, series = {Cancers}, volume = {12}, journal = {Cancers}, number = {9}, issn = {2072-6694}, doi = {10.3390/cancers12092399}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-211157}, year = {2020}, abstract = {Utilizing 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT), we performed this pilot study to evaluate the link between cytogenetic/genomic markers and imaging patterns in relapsed/refractory (RR) multiple myeloma (MM). We retrospectively analyzed data of 24 patients with RRMM who were treated at our institution between November 2018 and February 2020. At the last relapse/progression, patients had been treated with a median of three (range 1-10) lines of therapy. Six (25\%) patients showed FDG avid extramedullary disease without adjacency to bone. We observed significantly higher maximum standardized uptake values (SUV\(_{max}\)) in patients harboring del(17p) compared with those without del(17p) (p = 0.025). Moreover, a high SUV\(_{max}\) of >15 indicated significantly shortened progression-free survival (PFS) (p = 0.01) and overall survival (OS) (p = 0.0002). One female patient exhibited biallelic TP53 alteration, i.e., deletion and mutation, in whom an extremely high SUV\(_{max}\) of 37.88 was observed. In summary, this pilot study suggested a link between del(17p)/TP53 alteration and high SUV\(_{max}\) on 18F-FDG PET/CT in RRMM patients. Further investigations are highly warranted at this point.}, language = {en} } @article{FroehlichSerflingHiguchietal.2021, author = {Fr{\"o}hlich, Matthias and Serfling, Sebastian and Higuchi, Takahiro and Pomper, Martin G. and Rowe, Steven P. and Schmalzing, Marc and Tony, Hans-Peter and Gernert, Michael and Strunz, Patrick-Pascal and Portegys, Jan and Schwaneck, Eva-Christina and Gadeholt, Ottar and Weich, Alexander and Buck, Andreas K. and Bley, Thorsten A. and Guggenberger, Konstanze V. and Werner, Rudolf A.}, title = {Whole-Body [\(^{18}\)F]FDG PET/CT Can Alter Diagnosis in Patients with Suspected Rheumatic Disease}, series = {Diagnostics}, volume = {11}, journal = {Diagnostics}, number = {11}, issn = {2075-4418}, doi = {10.3390/diagnostics11112073}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-250227}, year = {2021}, abstract = {The 2-deoxy-d-[\(^{18}\)F]fluoro-D-glucose (FDG) positron emission tomography/computed tomography (PET/CT) is widely utilized to assess the vascular and articular inflammatory burden of patients with a suspected diagnosis of rheumatic disease. We aimed to elucidate the impact of [\(^{18}\)F]FDG PET/CT on change in initially suspected diagnosis in patients at the time of the scan. Thirty-four patients, who had undergone [\(^{18}\)F]FDG PET/CT, were enrolled and the initially suspected diagnosis prior to [18F]FDG PET/CT was compared to the final diagnosis. In addition, a semi-quantitative analysis including vessel wall-to-liver (VLR) and joint-to-liver (JLR) ratios was also conducted. Prior to [\(^{18}\)F]FDG PET/CT, 22/34 (64.7\%) of patients did not have an established diagnosis, whereas in 7/34 (20.6\%), polymyalgia rheumatica (PMR) was suspected, and in 5/34 (14.7\%), giant cell arteritis (GCA) was suspected by the referring rheumatologists. After [\(^{18}\)F]FDG PET/CT, the diagnosis was GCA in 19/34 (55.9\%), combined GCA and PMR (GCA + PMR) in 9/34 (26.5\%) and PMR in the remaining 6/34 (17.6\%). As such, [\(^{18}\)F]FDG PET/CT altered suspected diagnosis in 28/34 (82.4\%), including in all unclear cases. VLR of patients whose final diagnosis was GCA tended to be significantly higher when compared to VLR in PMR (GCA, 1.01 ± 0.08 (95\%CI, 0.95-1.1) vs. PMR, 0.92 ± 0.1 (95\%CI, 0.85-0.99), p = 0.07), but not when compared to PMR + GCA (1.04 ± 0.14 (95\%CI, 0.95-1.13), p = 1). JLR of individuals finally diagnosed with PMR (0.94 ± 0.16, (95\%CI, 0.83-1.06)), however, was significantly increased relative to JLR in GCA (0.58 ± 0.04 (95\%CI, 0.55-0.61)) and GCA + PMR (0.64 ± 0.09 (95\%CI, 0.57-0.71); p < 0.0001, respectively). In individuals with a suspected diagnosis of rheumatic disease, an inflammatory-directed [\(^{18}\)F]FDG PET/CT can alter diagnosis in the majority of the cases, particularly in subjects who were referred because of diagnostic uncertainty. Semi-quantitative assessment may be helpful in establishing a final diagnosis of PMR, supporting the notion that a quantitative whole-body read-out may be useful in unclear cases.}, language = {en} }