@phdthesis{Eissler2021, author = {Eißler, Christoph Marcel}, title = {Assessment of the left ventricular systolic and diastolic function in rats using electrocardiogram-gated cardiac positron emission tomography}, doi = {10.25972/OPUS-21976}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-219765}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2021}, abstract = {DD is a cardiac disturbance, which has gained increasing importance in recent years due to its important role in different cardiac disease and cardiomyopathies including ischemic cardiomyopathy, arterial hypertension and diabetic cardiomyopathy. ECG-gated 18F-FDG PET is an imaging technique, that can distinguish between districts of myocardial viability and myocardial scars and further provides information of great interest on the efficacy of experimental approaches designed to improve the cardiac function and/or myocardial metabolism in experimental small animal models. However, ECG-gated 18F-FDG PET is a technique whose feasibility in the assessment of the LV diastolic function in small animals has not been a subject of study. In this thesis, the ability of the ECG-gated 18F-FDG PET for the assessment of both the systolic and diastolic function in eight control rats and in seven ZDF rats, which are an experimental animal model mimicking T2DM conditions and diabetic related complications in humans including DCM, has been investigated The ECG-gated 18F-FDG PET imaging was performed under hyperinsulinemic-euglycemic clamping and the data were stored in list mode files and retrospectively reconstructed. The systolic and diastolic parameters were achieved from the time/volume and the time/filling curve calculated from the software HFV. Additionally, the influence of the number of gates per cardiac cycle on the LV volumes and function parameters has been studied. Hyperinsulinemic-euglycemic clamp procedure and blood glucose measurement did confirm the development of a manifest diabetes in the ZDF rats at the timepoint of the experiments. Regarding the systolic parameters, no significant difference could be detected between the ZDF and ZL rats. The values for the CO were similar in both groups, which demonstrates a similar LV systolic function in the ZDF and the ZL rats at the age of 13 weeks. Values for the systolic parameters are in good line with previous PET, MRI and cardiac catheterization-based studies in diabetic rats. The main finding of this study was that by using in vivo ECG-gated 18F-FDG PET and the software HFV, reliable diastolic parameters could be calculated. Moreover, it was possible to detect the presence of a mild impaired diastolic filling in the ZDF rats in absence of any systolic alteration. This impaired diastolic function in an early stage of diabetes could also be detected by other investigators, who used echocardiography or cardiac catheterization. Therefore, this is the first study showing, that the assessment of the diastolic function in rats can be carried out by ECG-gated 18F-FDG PET imaging. In conclusion, additionally to calculating LV volumes and LV EF, ECG-gated 18F-FDG PET can evaluate the diastolic function of healthy and diabetic rats and is able to detect a DD in ZDF rats.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{WernerEisslerHayakawaetal.2018, author = {Werner, Rudolf A. and Eissler, Christoph and Hayakawa, Nobuyuki and Arias-Loza, Paula and Wakabayashi, Hiroshi and Javadi, Mehrbod S. and Chen, Xinyu and Shinaji, Tetsuya and Lapa, Constantin and Pelzer, Theo and Higuchi, Takahiro}, title = {Left Ventricular Diastolic Dysfunction in a Rat Model of Diabetic Cardiomyopathy using ECG-gated \(^{18}\)F-FDG PET}, series = {Scientific Reports}, volume = {8}, journal = {Scientific Reports}, number = {17631}, doi = {10.1038/s41598-018-35986-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-171765}, year = {2018}, abstract = {In diabetic cardiomyopathy, left ventricular (LV) diastolic dysfunction is one of the earliest signs of cardiac involvement prior to the definitive development of heart failure (HF). We aimed to explore the LV diastolic function using electrocardiography (ECG)-gated \(^{18}\)F-fluorodeoxyglucose positron emission tomography (\(^{18}\)F-FDG PET) imaging beyond the assessment of cardiac glucose utilization in a diabetic rat model. ECG-gated \(^{18}\)F-FDG PET imaging was performed in a rat model of type 2 diabetes (ZDF fa/fa) and ZL control rats at age of 13 weeks (n=6, respectively). Under hyperinsulinemic-euglycemic clamp to enhance cardiac activity, \(^{18}\)F-FDG was administered and subsequently, list-mode imaging using a dedicated small animal PET system with ECG signal recording was performed. List-mode data were sorted and reconstructed into tomographic images of 16 frames per cardiac cycle. Left ventricular functional parameters (systolic: LV ejection fraction (EF), heart rate (HR) vs. diastolic: peak filling rate (PFR)) were obtained using an automatic ventricular edge detection software. No significant difference in systolic function could be obtained (ZL controls vs. ZDF rats: LVEF, 62.5±4.2 vs. 59.4±4.5\%; HR: 331±35 vs. 309±24 bpm; n.s., respectively). On the contrary, ECG-gated PET imaging showed a mild but significant decrease of PFR in the diabetic rats (ZL controls vs. ZDF rats: 12.1±0.8 vs. 10.2±1 Enddiastolic Volume/sec, P<0.01). Investigating a diabetic rat model, ECG-gated \(^{18}\)F-FDG PET imaging detected LV diastolic dysfunction while systolic function was still preserved. This might open avenues for an early detection of HF onset in high-risk type 2 diabetes before cardiac symptoms become apparent.}, language = {en} } @article{WernerChenMayaetal.2018, author = {Werner, Rudolf A. and Chen, Xinyu and Maya, Yoshifumi and Eissler, Christoph and Hirano, Mitsuru and Nose, Naoko and Wakabayashi, Hiroshi and Lapa, Constantin and Javadi, Mehrbod S. and Higuchi, Takahiro}, title = {The Impact of Ageing on 11C-Hydroxyephedrine Uptake in the Rat Heart}, series = {Scientific Reports}, volume = {8}, journal = {Scientific Reports}, number = {11120}, issn = {2281-5872}, doi = {10.1038/s41598-018-29509-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-164826}, year = {2018}, abstract = {We aimed to explore the impact of ageing on 11C-Hydroxyephedrine (11C-HED) uptake in the healthy rat heart in a longitudinal setting. To investigate a potential cold mass effect, the influence of specific activity on cardiac 11C-HED uptake was evaluated: 11C-HED was synthesized by N-methylation of (-)-metaraminol as the free base (radiochemical purity >95\%) and a wide range of specific activities (0.2-141.9 GBq/μmol) were prepared. \(^{11}\)C-HED (48.7±9.7MBq, ranged 0.2-60.4μg/kg cold mass) was injected in healthy Wistar Rats. Dynamic 23-frame PET images were obtained over 30 min. Time activity curves were generated for the blood input function and myocardial tissue. Cardiac 11C-HED retention index (\%/min) was calculated as myocardial tissue activity at 20-30 min divided by the integral of the blood activity curves. Additionally, the impact of ageing on myocardial 11CHED uptake was investigated longitudinally by PET studies at different ages of healthy Wistar Rats. A dose-dependent reduction of cardiac 11C-HED uptake was observed: The estimated retention index as a marker of norepinephrine function decreased at a lower specific activity (higher amount of cold mass). This observed high affinity of 11C-HED to the neural norepinephrine transporter triggered a subsequent study: In a longitudinal setting, the 11C-HED retention index decreased with increasing age. An age-related decline of cardiac sympathetic innervation could be demonstrated. The herein observed cold mass effect might increase in succeeding scans and therefore, 11C-HED microPET studies should be planned with extreme caution if one single radiosynthesis is scheduled for multiple animals.}, subject = {Positronen-Emissions-Tomografie}, language = {en} }