@article{GuckenbergerHawkinsFlentjeetal.2012, author = {Guckenberger, Matthias and Hawkins, Maria and Flentje, Michael and Sweeney, Reinhart A.}, title = {Fractionated radiosurgery for painful spinal metastases: DOSIS - a phase II trial}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-75853}, year = {2012}, abstract = {Background One third of all cancer patients will develop bone metastases and the vertebral column is involved in approximately 70 \% of these patients. Conventional radiotherapy with of 1-10 fractions and total doses of 8-30 Gy is the current standard for painful vertebral metastases; however, the median pain response is short with 3-6 months and local tumor control is limited with these rather low irradiation doses. Recent advances in radiotherapy technology - intensity modulated radiotherapy for generation of highly conformal dose distributions and image-guidance for precise treatment delivery - have made dose-escalated radiosurgery of spinal metastases possible and early results of pain and local tumor control are promising. The current study will investigate efficacy and safety of radiosurgery for painful vertebral metastases and three characteristics will distinguish this study. 1) A prognostic score for overall survival will be used for selection of patients with longer life expectancy to allow for analysis of long-term efficacy and safety. 2) Fractionated radiosurgery will be performed with the number of treatment fractions adjusted to either good (10 fractions) or intermediate (5 fractions) life expectancy. Fractionation will allow inclusion of tumors immediately abutting the spinal cord due to higher biological effective doses at the tumor - spinal cord interface compared to single fraction treatment. 3) Dose intensification will be performed in the involved parts of the vertebrae only, while uninvolved parts are treated with conventional doses using the simultaneous integrated boost concept. Methods / Design It is the study hypothesis that hypo-fractionated image-guided radiosurgery significantly improves pain relief compared to historic data of conventionally fractionated radiotherapy. Primary endpoint is pain response 3 months after radiosurgery, which is defined as pain reduction of ≥2 points at the treated vertebral site on the 0 to 10 Visual Analogue Scale. 60 patients will be included into this two-centre phase II trial. Conclusions Results of this study will refine the methods of patient selection, target volume definition, treatment planning and delivery as well as quality assurance for radiosurgery. It is the intention of this study to form the basis for a future randomized controlled trial comparing conventional radiotherapy with fractionated radiosurgery for palliation of painful vertebral metastases. Trial registration ClinicalTrials.gov Identifier: NCT01594892}, subject = {Medizin}, language = {en} } @article{DjuzenovaElsnerKatzeretal.2013, author = {Djuzenova, Cholpon S. and Elsner, Ines and Katzer, Astrid and Worschech, Eike and Distel, Luitpold V. and Flentje, Michael and Polat, B{\"u}lent}, title = {Radiosensitivity in breast cancer assessed by the histone γ-H2AX and 53BP1 foci}, series = {Radiation Oncology}, journal = {Radiation Oncology}, doi = {10.1186/1748-717X-8-98}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-96110}, year = {2013}, abstract = {Background High expression of constitutive histone γ-H2AX, a sensitive marker of DNA damage, might be indicative of defective DNA repair pathway or genomic instability. 53BP1 (p53-binding protein 1) is a conserved checkpoint protein with properties of a DNA double-strand breaks sensor. This study explores the relationship between the clinical radiosensitivity of tumor patients and the expression/induction of γ-H2AX and 53BP1 in vitro. Methods Using immunostaining, we assessed spontaneous and radiation-induced foci of γ-H2AX and 53 BP1 in peripheral blood mononuclear cells derived from unselected breast cancer (BC) patients (n=57) undergoing radiotherapy (RT). Cells from apparently healthy donors (n=12) served as references. Results Non-irradiated cells from controls and unselected BC patients exhibited similar baseline levels of DNA damage assessed by γ-H2AX and 53BP1 foci. At the same time, the γ-H2AX assay of in vitro irradiated cells revealed significant differences between the control group and the group of unselected BC patients with respect to the initial (0.5 Gy, 30 min) and residual (2 Gy, 24 h post-radiation) DNA damage. The numbers of 53BP1 foci analyzed in 35 BC patients were significantly higher than in controls only in case of residual DNA damage. A weak correlation was found between residual foci of both proteins tested. In addition, cells from cancer patients with an adverse acute skin reaction (grade 3) to RT showed significantly increased radiation-induced γ-H2AX foci and their protracted disappearance compared to the group of BC patients with normal skin reaction (grade 0-1). The mean number of γ-H2AX foci after 5 clinical fractions was significantly higher than that before RT, especially in clinically radiosensitive patients. Conclusions The γ-H2AX assay may have potential for screening individual radiosensitivity of breast cancer patients.}, subject = {DNS-Sch{\"a}digung}, language = {en} } @article{FlentjeRichter2021, author = {Flentje, Michael and Richter, J{\"u}rgen}, title = {Professor Dr. Werner Bohndorf gestorben}, series = {Strahlentherapie und Onkologie}, volume = {197}, journal = {Strahlentherapie und Onkologie}, number = {7}, issn = {1439-099X}, doi = {10.1007/s00066-021-01792-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-264838}, pages = {664-665}, year = {2021}, abstract = {Kein Abstract verf{\"u}gbar.}, language = {de} } @article{LewitzkiKlementKosmalaetal.2019, author = {Lewitzki, Victor and Klement, Rainer J. and Kosmala, Rebekka and Lisowski, Dominik and Flentje, Michael and Polat, B{\"u}lent}, title = {Accelerated hyperfractionated radiochemotherapy with temozolomide is equivalent to normofractionated radiochemotherapy in a retrospective analysis of patients with glioblastoma}, series = {Radiation Oncology}, volume = {14}, journal = {Radiation Oncology}, doi = {10.1186/s13014-019-1427-5}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-202614}, pages = {227}, year = {2019}, abstract = {Background Current standard of treatment for newly diagnosed patients with glioblastoma (GBM) is surgical resection with adjuvant normofractionated radiotherapy (NFRT) combined with temozolomide (TMZ) chemotherapy. Hyperfractionated accelerated radiotherapy (HFRT) which was known as an option from randomized controlled trials before the temozolomide era has not been compared to the standard therapy in a randomized setting combined with TMZ. Methods Data of 152 patients with newly diagnosed GBM treated from 10/2004 until 7/2018 at a single tertiary care institution were extracted from a clinical database and retrospectively analyzed. Thirty-eight patients treated with NFRT of 60 Gy in 30 fractions (34 with simultaneous and 2 with sequential TMZ) were compared to 114 patients treated with HFRT of 54.0 Gy in 30 fraction of 1.8 Gy twice daily (109 with simultaneous and 3 with sequential TMZ). The association between treatment protocol and other variables with overall survival (OS) was assessed using univariable and multivariable Cox regression analysis; the latter was performed using variables selected by the LASSO method. Results Median overall survival (OS) was 20.3 month for the entire cohort. For patients treated with NFRT median OS was 24.4 months compared to 18.5 months in patients treated with HFRT (p = 0.131). In univariable regression analysis the use of dexamethasone during radiotherapy had a significant negative impact on OS in both patient groups, HR 2.21 (95\% CI 1.47-3.31, p = 0.0001). In multivariable analysis adjusted for O6-methylguanine-DNA methyl-transferase (MGMT) promotor methylation status, salvage treatment and secondary GBM, the use of dexamethasone was still a negative prognostic factor, HR 1.95 (95\% CI 1.21-3.13, p = 0.006). Positive MGMT-methylation status and salvage treatment were highly significant positive prognostic factors. There was no strong association between treatment protocol and OS (p = 0.504). Conclusions Our retrospective analysis supports the hypothesis of equivalence between HFRT and the standard protocol of treatment for GBM. For those patients who are willing to obtain the benefit of shortening the course of radiochemotherapy, HFRT may be an alternative with comparable efficacy although it was not yet tested in a large prospective randomized study against the current standard. The positive influence of salvage therapy and negative impact of concomitant use of corticosteroids should be addressed in future prospective trials. To confirm our results, we plan to perform a pooled analysis with other tertiary clinics in order to achieve better statistical reliability.}, language = {en} } @article{KroeberWengerSchwegleretal.2015, author = {Kroeber, Jana and Wenger, Barbara and Schwegler, Manuela and Daniel, Christoph and Schmidt, Manfred and Djuzenova, Cholpon S and Polat, B{\"u}lent and Flentje, Michael and Fietkau, Rainer and Distel, Luitpold V.}, title = {Distinct increased outliers among 136 rectal cancer patients assessed by \(\gamma\)H2AX}, series = {Radiation Oncology}, volume = {10}, journal = {Radiation Oncology}, number = {36}, doi = {10.1186/s13014-015-0344-5}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-144085}, year = {2015}, abstract = {Background: In recent years attention has focused on \(\gamma\)H2AX as a very sensitive double strand break indicator. It has been suggested that \(\gamma\)H2AX might be able to predict individual radiosensitivity. Our aim was to study the induction and repair of DNA double strand breaks labelled by \(\gamma\)H2AX in a large cohort. Methods: In a prospective study lymphocytes of 136 rectal cancer (RC) patients and 59 healthy individuals were ex vivo irradiated (IR) and initial DNA damage was compared to remaining DNA damage after 2 Gy and 24 hours repair time and preexisting DNA damage in unirradiated lymphocytes. Lymphocytes were immunostained with anti-\(\gamma\)H2AX antibodies and microscopic images with an extended depth of field were acquired. \(\gamma\)H2AX foci counting was performed using a semi-automatic image analysis software. Results: Distinct increased values of preexisting and remaining \(\gamma\)H2AX foci in the group of RC patients were found compared to the healthy individuals. Additionally there are clear differences within the groups and there are outliers in about 12\% of the RC patients after ex vivo IR. Conclusions: The \(\gamma\)H2AX assay has the capability to identify a group of outliers which are most probably patients with increased radiosensitivity having the highest risk of suffering radiotherapy-related late sequelae.}, language = {en} } @article{PollmannToussaintFlentjeetal.2022, author = {Pollmann, Stephan and Toussaint, Andr{\´e} and Flentje, Michael and Wegener, Sonja and Lewitzki, Victor}, title = {Dosimetric evaluation of commercially available flat vs. self-produced 3D-conformal silicone boluses for the head and neck region}, series = {Frontiers in Oncology}, volume = {12}, journal = {Frontiers in Oncology}, issn = {2234-943X}, doi = {10.3389/fonc.2022.881439}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-283156}, year = {2022}, abstract = {Background Boluses are routinely used in radiotherapy to modify surface doses. Nevertheless, considerable dose discrepancies may occur in some cases due to fit inaccuracy of commercially available standard flat boluses. Moreover, due to the simple geometric design of conventional boluses, also surrounding healthy skin areas may be unintentionally covered, resulting in the unwanted dose buildup. With the fused deposition modeling (FDM) technique, there is a simple and possibly cost-effective way to solve these problems in routine clinical practice. This paper presents a procedure of self-manufacturing bespoke patient-specific silicone boluses and the evaluation of buildup and fit accuracy in comparison to standard rectangular commercially available silicone boluses. Methods 3D-conformal silicone boluses were custom-built to cover the surgical scar region of 25 patients who received adjuvant radiotherapy of head and neck cancer at the University Hospital W{\"u}rzburg. During a standard CT-based planning procedure, a 5-mm-thick 3D bolus contour was generated to cover the radiopaque marked surgical scar with an additional safety margin. From these digital contours, molds were 3D printed and poured with silicone. Dose measurements for both types of boluses were performed with radiochromic films (EBT3) at three points per patient—at least one aimed to be in the high-dose area (scar) and one in the lower-dose area (spared healthy skin). Surface-bolus distance, which ideally should not be present, was determined from cone-beam CT performed for positioning control. The dosimetric influence of surface-bolus distance was also determined on slab phantom for different field sizes. The trial was performed with hardware that may be routinely available in every radiotherapy department, with the exception of the 3D printer. The required number of patients was determined based on the results of preparatory measurements with the help of the statistical consultancy of the University of W{\"u}rzburg. The number of measuring points represents the total number of patients. Results In the high-dose area of the scar, there was a significantly better intended dose buildup of 2.45\% (95\%CI 0.0014-0.0477, p = 0.038, N = 30) in favor of a 3D-conformal bolus. Median distances between the body surface and bolus differed significantly between 3D-conformal and commercially available boluses (3.5 vs. 7.9 mm, p = 0.001). The surface dose at the slab phantom did not differ between commercially available and 3D-conformal boluses. Increasing the surface-bolus distance from 5 to 10 mm decreased the surface dose by approximately 2\% and 11\% in the 6 × 6- and 3 × 3-cm2 fields, respectively. In comparison to the commercially available bolus, an unintended dose buildup in the healthy skin areas was reduced by 25.9\% (95\%CI 19.5-32.3, p < 0.01, N = 37) using the 3D-conformal bolus limited to the region surrounding the surgical scar. Conclusions Using 3D-conformal boluses allows a comparison to the commercially available boluses' dose buildup in the covered areas. Smaller field size is prone to a larger surface-bolus distance effect. Higher conformity of 3D-conformal boluses reduces this effect. This may be especially relevant for volumetric modulated arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) techniques with a huge number of smaller fields. High conformity of 3D-conformal boluses reduces an unintended dose buildup in healthy skin. The limiting factor in the conformity of 3D-conformal boluses in our setting was the immobilization mask, which was produced primarily for the 3D boluses. The mask itself limited tight contact of subsequently produced 3D-conformal boluses to the mask-covered body areas. In this respect, bolus adjustment before mask fabrication will be done in the future setting.}, language = {en} } @article{PolatKaiserWohllebenetal.2017, author = {Polat, B{\"u}lent and Kaiser, Philipp and Wohlleben, Gisela and Gehrke, Thomas and Scherzad, Agmal and Scheich, Matthias and Malzahn, Uwe and Fischer, Thomas and Vordermark, Dirk and Flentje, Michael}, title = {Perioperative changes in osteopontin and TGFβ1 plasma levels and their prognostic impact for radiotherapy in head and neck cancer}, series = {BMC Cancer}, volume = {17}, journal = {BMC Cancer}, number = {6}, doi = {10.1186/s12885-016-3024-4}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-157529}, year = {2017}, abstract = {Background: In head and neck cancer little is known about the kinetics of osteopontin (OPN) expression after tumor resection. In this study we evaluated the time course of OPN plasma levels before and after surgery. Methods: Between 2011 and 2013 41 consecutive head and neck cancer patients were enrolled in a prospective study (group A). At different time points plasma samples were collected: T0) before, T1) 1 day, T2) 1 week and T3) 4 weeks after surgery. Osteopontin and TGFβ1 plasma concentrations were measured with a commercial ELISA system. Data were compared to 131 head and neck cancer patients treated with primary (n = 42) or postoperative radiotherapy (n = 89; group B1 and B2). Results: A significant OPN increase was seen as early as 1 day after surgery (T0 to T1, p < 0.01). OPN levels decreased to base line 3-4 weeks after surgery. OPN values were correlated with postoperative TGFβ1 expression suggesting a relation to wound healing. Survival analysis showed a significant benefit for patients with lower OPN levels both in the primary and postoperative radiotherapy group (B1: 33 vs 11.5 months, p = 0.017, B2: median not reached vs 33.4, p = 0.031). TGFβ1 was also of prognostic significance in group B1 (33.0 vs 10.7 months, p = 0.003). Conclusions: Patients with head and neck cancer showed an increase in osteopontin plasma levels directly after surgery. Four weeks later OPN concentration decreased to pre-surgery levels. This long lasting increase was presumably associated to wound healing. Both pretherapeutic osteopontin and TGFβ1 had prognostic impact.}, language = {en} } @article{TamihardjaLawrenzLutyjetal.2022, author = {Tamihardja, J{\"o}rg and Lawrenz, Ingulf and Lutyj, Paul and Weick, Stefan and Guckenberger, Matthias and Polat, B{\"u}lent and Flentje, Michael}, title = {Propensity score-matched analysis comparing dose-escalated intensity-modulated radiation therapy versus external beam radiation therapy plus high-dose-rate brachytherapy for localized prostate cancer}, series = {Strahlentherapie und Onkologie}, volume = {198}, journal = {Strahlentherapie und Onkologie}, number = {8}, doi = {10.1007/s00066-022-01953-y}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-325055}, pages = {735-743}, year = {2022}, abstract = {Purpose Dose-escalated external beam radiation therapy (EBRT) and EBRT + high-dose-rate brachytherapy (HDR-BT) boost are guideline-recommended treatment options for localized prostate cancer. The purpose of this study was to compare long-term outcome and toxicity of dose-escalated EBRT versus EBRT + HDR-BT boost. Methods From 2002 to 2019, 744 consecutive patients received either EBRT or EBRT + HDR-BT boost, of whom 516 patients were propensity score matched. Median follow-up was 95.3 months. Cone beam CT image-guided EBRT consisted of 33 fractions of intensity-modulated radiation therapy with simultaneous integrated boost up to 76.23 Gy (D\(_{Mean}\)). Combined treatment was delivered as 46 Gy (D\(_{Mean}\)) EBRT, followed by two fractions HDR-BT boost with 9 Gy (D\(_{90\\%}\)). Propensity score matching was applied before analysis of the primary endpoint, estimated 10-year biochemical relapse-free survival (bRFS), and the secondary endpoints metastasis-free survival (MFS) and overall survival (OS). Prognostic parameters were analyzed by Cox proportional hazard modelling. Genitourinary (GU)/gastrointestinal (GI) toxicity evaluation used the Common Toxicity Criteria for Adverse Events (v5.0). Results The estimated 10-year bRFS was 82.0\% vs. 76.4\% (p = 0.075) for EBRT alone versus combined treatment, respectively. The estimated 10-year MFS was 82.9\% vs. 87.0\% (p = 0.195) and the 10-year OS was 65.7\% vs. 68.9\% (p = 0.303), respectively. Cumulative 5‑year late GU ≥ grade 2 toxicities were seen in 23.6\% vs. 19.2\% (p = 0.086) and 5‑year late GI ≥ grade 2 toxicities in 11.1\% vs. 5.0\% of the patients (p = 0.002); cumulative 5‑year late grade 3 GU toxicity occurred in 4.2\% vs. 3.6\% (p = 0.401) and GI toxicity in 1.0\% vs. 0.3\% (p = 0.249), respectively. Conclusion Both treatment groups showed excellent long-term outcomes with low rates of severe toxicity.}, language = {en} } @article{GrabenbauerFlentje2022, author = {Grabenbauer, Felix and Flentje, Michael}, title = {Salvage-Bestrahlung der Prostataloge: Mitbestrahlung der regionalen LK und Bedeutung der ADT}, series = {Strahlentherapie und Onkologie}, volume = {198}, journal = {Strahlentherapie und Onkologie}, number = {12}, doi = {10.1007/s00066-022-02001-5}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-325047}, pages = {1119-1121}, year = {2022}, abstract = {No abstract available.}, language = {de} } @article{WeickBreuerRichteretal.2020, author = {Weick, Stefan and Breuer, Kathrin and Richter, Anne and Exner, Florian and Str{\"o}hle, Serge-Peer and Lutyj, Paul and Tamihardja, J{\"o}rg and Veldhoen, Simon and Flentje, Michael and Polat, B{\"u}lent}, title = {Non-rigid image registration of 4D-MRI data for improved delineation of moving tumors}, series = {BMC Medical Imaging}, volume = {20}, journal = {BMC Medical Imaging}, doi = {10.1186/s12880-020-00439-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-229271}, year = {2020}, abstract = {Background To increase the image quality of end-expiratory and end-inspiratory phases of retrospective respiratory self-gated 4D MRI data sets using non-rigid image registration for improved target delineation of moving tumors. Methods End-expiratory and end-inspiratory phases of volunteer and patient 4D MRI data sets are used as targets for non-rigid image registration of all other phases using two different registration schemes: In the first, all phases are registered directly (dir-Reg) while next neighbors are successively registered until the target is reached in the second (nn-Reg). Resulting data sets are quantitatively compared using diaphragm and tumor sharpness and the coefficient of variation of regions of interest in the lung, liver, and heart. Qualitative assessment of the patient data regarding noise level, tumor delineation, and overall image quality was performed by blinded reading based on a 4 point Likert scale. Results The median coefficient of variation was lower for both registration schemes compared to the target. Median dir-Reg coefficient of variation of all ROIs was 5.6\% lower for expiration and 7.0\% lower for inspiration compared with nn-Reg. Statistical significant differences between the two schemes were found in all comparisons. Median sharpness in inspiration is lower compared to expiration sharpness in all cases. Registered data sets were rated better compared to the targets in all categories. Over all categories, mean expiration scores were 2.92 +/- 0.18 for the target, 3.19 +/- 0.22 for nn-Reg and 3.56 +/- 0.14 for dir-Reg and mean inspiration scores 2.25 +/- 0.12 for the target, 2.72 +/- 215 0.04 for nn-Reg and 3.78 +/- 0.04 for dir-Reg. Conclusions In this work, end-expiratory and inspiratory phases of a 4D MRI data sets are used as targets for non-rigid image registration of all other phases. It is qualitatively and quantitatively shown that image quality of the targets can be significantly enhanced leading to improved target delineation of moving tumors.}, language = {en} }