@article{GabrielJirůHillmannKraftetal.2020, author = {Gabriel, Katharina M. A. and J{\´i}rů-Hillmann, Steffi and Kraft, Peter and Selig, Udo and R{\"u}cker, Victoria and M{\"u}hler, Johannes and D{\"o}tter, Klaus and Keidel, Matthias and Soda, Hassan and Rascher, Alexandra and Schneider, Rolf and Pfau, Mathias and Hoffmann, Roy and Stenzel, Joachim and Benghebrid, Mohamed and Goebel, Tobias and Doerck, Sebastian and Kramer, Daniela and Haeusler, Karl Georg and Volkmann, Jens and Heuschmann, Peter U. and Fluri, Felix}, title = {Two years' experience of implementing a comprehensive telemedical stroke network comprising in mainly rural region: the Transregional Network for Stroke Intervention with Telemedicine (TRANSIT-Stroke)}, series = {BMC Neurology}, volume = {20}, journal = {BMC Neurology}, doi = {10.1186/s12883-020-01676-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-229214}, year = {2020}, abstract = {Background Telemedicine improves the quality of acute stroke care in rural regions with limited access to specialized stroke care. We report the first 2 years' experience of implementing a comprehensive telemedical stroke network comprising all levels of stroke care in a defined region. Methods The TRANSIT-Stroke network covers a mainly rural region in north-western Bavaria (Germany). All hospitals providing acute stroke care in this region participate in TRANSIT-Stroke, including four hospitals with a supra-regional certified stroke unit (SU) care (level III), three of those providing teleconsultation to two hospitals with a regional certified SU (level II) and five hospitals without specialized SU care (level I). For a two-year-period (01/2015 to 12/2016), data of eight of these hospitals were available; 13 evidence-based quality indicators (QIs) related to processes during hospitalisation were evaluated quarterly and compared according to predefined target values between level-I- and level-II/III-hospitals. Results Overall, 7881 patients were included (mean age 74.6 years +/- 12.8; 48.4\% female). In level-II/III-hospitals adherence of all QIs to predefined targets was high ab initio. In level-I-hospitals, three patterns of QI-development were observed: a) high adherence ab initio (31\%), mainly in secondary stroke prevention; b) improvement over time (44\%), predominantly related to stroke specific diagnosis and in-hospital organization; c) no clear time trends (25\%). Overall, 10 out of 13 QIs reached predefined target values of quality of care at the end of the observation period. Conclusion The implementation of the comprehensive TRANSIT-Stroke network resulted in an improvement of quality of care in level-I-hospitals.}, language = {en} } @article{ElhfnawyHeuschmannPhametal.2019, author = {Elhfnawy, Ahmed Mohamed and Heuschmann, Peter U. and Pham, Mirko and Volkmann, Jens and Fluri, Felix}, title = {Stenosis length and degree interact with the risk of cerebrovascular events related to internal carotid artery stenosis}, series = {Frontiers in Neurology}, volume = {10}, journal = {Frontiers in Neurology}, number = {317}, issn = {1664-2295}, doi = {10.3389/fneur.2019.00317}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-196225}, year = {2019}, abstract = {Background and Purpose: Internal carotid artery stenosis (ICAS)≥70\% is a leading cause of ischemic cerebrovascular events (ICVEs). However, a considerable percentage of stroke survivors with symptomatic ICAS (sICAS) have <70\% stenosis with a vulnerable plaque. Whether the length of ICAS is associated with high risk of ICVEs is poorly investigated. Our main aim was to investigate the relation between the length of ICAS and the development of ICVEs. Methods: In a retrospective cross-sectional study, we identified 95 arteries with sICAS and another 64 with asymptomatic internal carotid artery stenosis (aICAS) among 121 patients with ICVEs. The degree and length of ICAS as well as plaque echolucency were assessed on ultrasound scans. Results: A statistically significant inverse correlation between the ultrasound-measured length and degree of ICAS was detected for sICAS≥70\% (Spearman correlation coefficient ρ = -0.57, p < 0.001, n = 51) but neither for sICAS<70\% (ρ = 0.15, p = 0.45, n = 27) nor for aICAS (ρ = 0.07, p = 0.64, n = 54). The median (IQR) length for sICAS<70\% and ≥70\% was 17 (15-20) and 15 (12-19) mm (p = 0.06), respectively, while that for sICAS<90\% and sICAS 90\% was 18 (15-21) and 13 (10-16) mm, respectively (p < 0.001). Among patients with ICAS <70\%, a cut-off length of ≥16 mm was found for sICAS rather than aICAS with a sensitivity and specificity of 74.1\% and 51.1\%, respectively. Irrespective of the stenotic degree, plaques of the sICAS compared to aICAS were significantly more often echolucent (43.2 vs. 24.6\%, p = 0.02). Conclusion: We found a statistically insignificant tendency for the ultrasound-measured length of sICAS<70\% to be longer than that of sICAS≥70\%. Moreover, the ultrasound-measured length of sICAS<90\% was significantly longer than that of sICAS 90\%. Among patients with sICAS≥70\%, the degree and length of stenosis were inversely correlated. Larger studies are needed before a clinical implication can be drawn from these results.}, language = {en} }