@article{LiWinklerPabstetal.2015, author = {Li, Mengxia and Winkler, Beate and Pabst, Thomas and Bley, Thorsten and K{\"o}stler, Herbert and Neubauer, Henning}, title = {Fast MR Imaging of the paediatric abdomen with CAIPIRINHA-accelerated T1w 3D FLASH and with high-resolution T2w HASTE: a study on image quality}, series = {Gastroenterology Research and Practice}, volume = {2015}, journal = {Gastroenterology Research and Practice}, number = {693654}, doi = {10.1155/2015/693654}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-149217}, year = {2015}, abstract = {The aim of this study was to explore the applicability of fast MR techniques to routine paediatric abdominopelvic MRI at 1.5 Tesla. "Controlled Aliasing in Parallel Imaging Results in Higher Acceleration-" (CAIPIRINHA-) accelerated contrast-enhanced-T1w 3D FLASH imaging was compared to standard T1w 2D FLASH imaging with breath-holding in 40 paediatric patients and to respiratory-triggered T1w TSE imaging in 10 sedated young children. In 20 nonsedated patients, we compared T2w TIRM to fat-saturated T2w HASTE imaging. Two observers performed an independent and blinded assessment of overall image quality. Acquisition time was reduced by the factor of 15 with CAIPIRINHA-accelerated T1w FLASH and by 7 with T2w HASTE. With CAIPIRINHA and with HASTE, there were significantly less motion artefacts in nonsedated patients. In sedated patients, respiratory-triggered T1w imaging in general showed better image quality. However, satisfactory image quality was achieved with CAIPIRINHA in two sedated patients where respiratory triggering failed. In summary, fast scanning with CAIPIRINHA and HASTE presents a reliable high quality alternative to standard sequences in paediatric abdominal MRI. Paediatric patients, in particular, benefit greatly from fast image acquisition with less breath-hold cycles or shorter sedation.}, language = {en} } @article{PetritschKoestlerGassenmaieretal.2016, author = {Petritsch, Bernhard and K{\"o}stler, Herbert and Gassenmaier, Tobias and Kunz, Andreas S and Bley, Thorsten A and Horn, Michael}, title = {An investigation into potential gender-specific differences in myocardial triglyceride content assessed by \(^{1}\)H-Magnetic Resonance Spectroscopy at 3Tesla}, series = {Journal of International Medical Research}, volume = {44}, journal = {Journal of International Medical Research}, number = {3}, doi = {10.1177/0300060515603884}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-168808}, pages = {585-591}, year = {2016}, abstract = {Objective: Over the past decade, myocardial triglyceride content has become an accepted biomarker for chronic metabolic and cardiac disease. The purpose of this study was to use proton (hydrogen 1)-magnetic resonance spectroscopy (\(^{1}\)H-MRS) at 3Tesla (3 T) field strength to assess potential gender-related differences in myocardial triglyceride content in healthy individuals. Methods: Cardiac MR imaging was performed to enable accurate voxel placement and obtain functional and morphological information. Double triggered (i.e., ECG and respiratory motion gating) \(^{1}\)H-MRS was used to quantify myocardial triglyceride levels for each gender. Two-sample t-test and Mann-Whitney U-test were used for statistical analyses. Results: In total, 40 healthy volunteers (22 male, 18 female; aged >18 years and age matched) were included in the study. Median myocardial triglyceride content was 0.28\% (interquartile range [IQR] 0.17-0.42\%) in male and 0.24\% (IQR 0.14-0.45\%) in female participants, and no statistically significant difference was observed between the genders. Furthermore, no gender-specific difference in ejection fraction was observed, although on average, male participants presented with a higher mean ± SD left ventricular mass (136.3 ± 25.2 g) than female participants (103.9 ± 16.1 g). Conclusions: The study showed that \(^{1}\)H-MRS is a capable, noninvasive tool for acquisition of myocardial triglyceride metabolites. Myocardial triglyceride concentration was shown to be unrelated to gender in this group of healthy volunteers.}, language = {en} } @article{GilbertBoehmEdenetal.2016, author = {Gilbert, Fabian and B{\"o}hm, Dirk and Eden, Lars and Schmalzl, Jonas and Meffert, Rainer H. and K{\"o}stler, Herbert and Weng, Andreas M. and Ziegler, Dirk}, title = {Comparing the MRI-based Goutallier Classification to an experimental quantitative MR spectroscopic fat measurement of the supraspinatus muscle}, series = {BMC Musculoskeletal Disorders}, volume = {17}, journal = {BMC Musculoskeletal Disorders}, number = {355}, doi = {10.1186/s12891-016-1216-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-147788}, year = {2016}, abstract = {Background The Goutallier Classification is a semi quantitative classification system to determine the amount of fatty degeneration in rotator cuff muscles. Although initially proposed for axial computer tomography scans it is currently applied to magnet-resonance-imaging-scans. The role for its clinical use is controversial, as the reliability of the classification has been shown to be inconsistent. The purpose of this study was to compare the semi quantitative MRI-based Goutallier Classification applied by 5 different raters to experimental MR spectroscopic quantitative fat measurement in order to determine the correlation between this classification system and the true extent of fatty degeneration shown by spectroscopy. Methods MRI-scans of 42 patients with rotator cuff tears were examined by 5 shoulder surgeons and were graduated according to the MRI-based Goutallier Classification proposed by Fuchs et al. Additionally the fat/water ratio was measured with MR spectroscopy using the experimental SPLASH technique. The semi quantitative grading according to the Goutallier Classification was statistically correlated with the quantitative measured fat/water ratio using Spearman's rank correlation. Results Statistical analysis of the data revealed only fair correlation of the Goutallier Classification system and the quantitative fat/water ratio with R = 0.35 (p < 0.05). By dichotomizing the scale the correlation was 0.72. The interobserver and intraobserver reliabilities were substantial with R = 0.62 and R = 0.74 (p < 0.01). Conclusion The correlation between the semi quantitative MRI based Goutallier Classification system and MR spectroscopic fat measurement is weak. As an adequate estimation of fatty degeneration based on standard MRI may not be possible, quantitative methods need to be considered in order to increase diagnostic safety and thus provide patients with ideal care in regard to the amount of fatty degeneration. Spectroscopic MR measurement may increase the accuracy of the Goutallier classification and thus improve the prediction of clinical results after rotator cuff repair. However, these techniques are currently only available in an experimental setting.}, language = {en} } @article{TranGiaWechBleyetal.2015, author = {Tran-Gia, Johannes and Wech, Tobias and Bley, Thorsten and K{\"o}stler, Herbert}, title = {Model-Based Acceleration of Look-Locker T1 Mapping}, series = {PLoS One}, volume = {10}, journal = {PLoS One}, number = {4}, doi = {10.1371/journal.pone.0122611}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-126436}, pages = {e0122611}, year = {2015}, abstract = {Mapping the longitudinal relaxation time \(T_1\) has widespread applications in clinical MRI as it promises a quantitative comparison of tissue properties across subjects and scanners. Due to the long scan times of conventional methods, however, the use of quantitative MRI in clinical routine is still very limited. In this work, an acceleration of Inversion-Recovery Look-Locker (IR-LL) \(T_1\) mapping is presented. A model-based algorithm is used to iteratively enforce an exponential relaxation model to a highly undersampled radially acquired IR-LL dataset obtained after the application of a single global inversion pulse. Using the proposed technique, a \(T_1\) map of a single slice with 1.6mm in-plane resolution and 4mm slice thickness can be reconstructed from data acquired in only 6s. A time-consuming segmented IR experiment was used as gold standard for \(T_1\) mapping in this work. In the subsequent validation study, the model-based reconstruction of a single-inversion IR-LL dataset exhibited a \(T_1\) difference of less than 2.6\% compared to the segmented IR-LL reference in a phantom consisting of vials with \(T_1\) values between 200ms and 3000ms. In vivo, the \(T_1\) difference was smaller than 5.5\% in WM and GM of seven healthy volunteers. Additionally, the \(T_1\) values are comparable to standard literature values. Despite the high acceleration, all model-based reconstructions were of a visual quality comparable to fully sampled references. Finally, the reproducibility of the \(T_1\) mapping method was demonstrated in repeated acquisitions. In conclusion, the presented approach represents a promising way for fast and accurate \(T_1\) mapping using radial IR-LL acquisitions without the need of any segmentation.}, language = {en} } @article{NordbeckBeerKoestleretal.2012, author = {Nordbeck, Peter and Beer, Meinrad and K{\"o}stler, Herbert and Ladd, Mark E. and Quick, Harald H. and Bauer, Wolfgang R. and Ritter, Oliver}, title = {Cardiac catheter ablation under real-time magnetic resonance guidance}, series = {European Heart Journal}, volume = {33}, journal = {European Heart Journal}, number = {15}, doi = {10.1093/eurheartj/ehs139}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-125638}, year = {2012}, abstract = {One of the main shortcomings of interventional electrophysiology (EP) is its inability to generate sufficient soft tissue contrast for intra-procedural visualization of the myocardium and the surrounding tissue, using conventional imaging techniques. Interventional cardiovascular magnetic resonance imaging (MRI) aims at bringing about significant improvements to the complex and decisive EP interventions far beyond the capabilities of currently available supportive imaging techniques used to surmount the drawbacks of fluoroscopy, as MRI not only allows of precise three-dimensional exposure of the cardiovascular morphology, but also proves to be a promising technique exclusively suitable for direct visualization of arrhythmogenic substrate and therapeutic effects. The major challenge posed by clinical …}, language = {en} } @article{ZellerMuellerGutberletetal.2013, author = {Zeller, Mario and M{\"u}ller, Alexander and Gutberlet, Marcel and Nichols, Thomas and Hahn, Dietbert and K{\"o}stler, Herbert and Bartsch, Andreas J.}, title = {Boosting BOLD fMRI by K-Space Density Weighted Echo Planar Imaging}, series = {PLoS ONE}, journal = {PLoS ONE}, doi = {10.1371/journal.pone.0074501}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-97233}, year = {2013}, abstract = {Functional magnetic resonance imaging (fMRI) has become a powerful and influential method to non-invasively study neuronal brain activity. For this purpose, the blood oxygenation level-dependent (BOLD) effect is most widely used. T2* weighted echo planar imaging (EPI) is BOLD sensitive and the prevailing fMRI acquisition technique. Here, we present an alternative to its standard Cartesian recordings, i.e. k-space density weighted EPI, which is expected to increase the signal-to-noise ratio in fMRI data. Based on in vitro and in vivo pilot measurements, we show that fMRI by k-space density weighted EPI is feasible and that this new acquisition technique in fact boosted spatial and temporal SNR as well as the detection of local fMRI activations. Spatial resolution, spatial response function and echo time were identical for density weighted and conventional Cartesian EPI. The signal-to-noise ratio gain of density weighting can improve activation detection and has the potential to further increase the sensitivity of fMRI investigations.}, language = {en} } @article{NeubauerEvangelistaMorbachetal.2012, author = {Neubauer, Henning and Evangelista, Laura and Morbach, Henner and Girschick, Hermann and Prelog, Martina and K{\"o}stler, Herbert and Hahn, Dietbert and Beer, Meinrad}, title = {Diffusion-weighted MRI of bone marrow oedema, soft tissue oedema and synovitis in paediatric patients: feasibility and initial experience}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-75521}, year = {2012}, abstract = {Background: MRI has become the mainstay of diagnostic imaging in paediatric rheumatology for lesion detection, differential diagnosis and therapy surveillance. MR imaging of synovitis, in particular, is indispensable for early diagnosis and follow-up in arthritis patients. We used diffusion-weighted MRI (DWI) as a new imaging modality in comparison to standard MRI sequences to study bone marrow oedema, soft-tissue oedema and synovitis in paediatric patients. Methods: A total of 52 patients (mean age 11 ± 5 years) with bone marrow oedema (n = 31), soft-tissue oedema (n = 20) and synovitis (n = 15) were examined with transversal diffusion-weighted single-shot echoplanar imaging in addition to standard MR sequences (T2W TIRM, T1W pre- and post-contrast). Diffusion-weighted images were used for lesion detection and apparent diffusion coefficient (ADC, unit × 10-3 mm2/s) values were measured with ROI technique on ADC maps. Results: In 50 of 52 patients, DWI delineated the lesion of interest corresponding to pathological signal increase on standard sequences. Mean ADC was 1.60 ± 0.14 (range 1.38 - 1.99) in osseous lesions, 1.72 ± 0.31 (range 1.43 - 2.56) in soft tissue oedema and 2.82 ± 0.24 (range 2.47 - 3.18) for joint effusion (ANOVA p<0.001). No significant difference in mean ADC was seen for inflammatory vs. non-inflammatory lesions. Relative signal intensity of oedema was similar for DWI and T2W TIRM. DWI visualised synovial restricted diffusion with a mean ADC of 2.12 ± 0.45 in 12 of 15 patients with synovitis. Conclusions: Diffusion-weighted MRI reliably visualises osseous and soft tissue oedema, as compared to standard sequences. DWI of synovitis is feasible in large joints and presents a novel approach to contrast-free imaging of synovitis. Whole-body DWI for chronic non-bacterial osteomyelitis should be evaluated in future studies.}, subject = {Medizin}, language = {en} } @article{GilbertKleinWengetal.2017, author = {Gilbert, Fabian and Klein, Detlef and Weng, Andreas Max and K{\"o}stler, Herbert and Schmitz, Benedikt and Schmalzl, Jonas and B{\"o}hm, Dirk}, title = {Supraspinatus muscle elasticity measured with real time shear wave ultrasound elastography correlates with MRI spectroscopic measured amount of fatty degeneration}, series = {BMC Muscoskeletal Disorders}, volume = {18}, journal = {BMC Muscoskeletal Disorders}, number = {549}, doi = {10.1186/s12891-017-1911-8}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-159378}, year = {2017}, abstract = {Background: Fatty Degeneration (FD) of the rotator cuff muscles influences functional and anatomical outcome after rotator cuff repair. The MRI based estimation of fatty degeneration is the gold standard. There is some evidence that Ultrasound elastography (EUS) can detect local differences of tissue stiffness in muscles and tendons. Shear-wave elastography (SWE) was evaluated to determine the extent to which shear wave velocity was associated with measures of fatty degeneration. MRI-spectroscopic fat measurement was used as a reference to quantify the amount of fat in the muscle belly. Methods: Forty-two patients underwent SWE of the supraspinatus muscles at its thickest diameter. After ultrasound evaluation an MRI-spectroscopic fat measurement of the supraspinatus muscle was performed using the SPLASH-technique. A gel filled capsule was used to locate the measured area in the MRI. The values of shear wave velocity (SWV) measured with SWE and spectroscopic fat measurement were correlated statistically using Pearson's correlation test. Results: Correlation of the fat amount measured with MRI-spectroscopy and the SWV measured with SWE was ρ =0.82. Spectroscopic measured fat ratio of the supraspinatus muscle ranged from 0\% to 77.41\% and SWV from 1.59 m/s to 5.32 m/s. In 4 patients no sufficient SWE could be performed, these individuals showed a larger diameter of the overlying soft tissue. SWV measured with SWE showed a good correlation with MRI spectroscopic fat amount of the supraspinatus muscle. Conclusion: These preliminary data suggest that SWE may be a sufficient tool in detecting and estimating the amount of fatty degeneration in the supraspinatus muscle in real time. Large overlying soft tissue may be a limitation in performing sufficient EUS.}, language = {en} } @article{RufBeerKoestleretal.2019, author = {Ruf, Katharina and Beer, Meinrad and K{\"o}stler, Herbert and Weng, Andreas Max and Neubauer, Henning and Klein, Alexander and Platek, Kathleen and Roth, Kristina and Beneke, Ralph and Hebestreit, Helge}, title = {Size-adjusted muscle power and muscle metabolism in patients with cystic fibrosis are equal to healthy controls - a case control study}, series = {BMC Pulmonary Medicine}, volume = {19}, journal = {BMC Pulmonary Medicine}, doi = {10.1186/s12890-019-1039-8}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-200981}, pages = {269}, year = {2019}, abstract = {Background Skeletal muscle function dysfunction has been reported in patients with cystic fibrosis (CF). Studies so far showed inconclusive data whether reduced exercise capacity is related to intrinsic muscle dysfunction in CF. Methods Twenty patients with CF and 23 age-matched controls completed an incremental cardiopulmonary cycling test. Further, a Wingate anaerobic test to assess muscle power was performed. In addition, all participants completed an incremental knee-extension test with 31P magnetic resonance spectroscopy to assess muscle metabolism (inorganic phosphate (Pi) and phosphocreatinine (PCr) as well as intracellular pH). In the MRI, muscle cross-sectional area of the M. quadriceps (qCSA) was also measured. A subgroup of 15 participants (5 CF, 10 control) additionally completed a continuous high-intensity, high-frequency knee-extension exercise task during 31P magnetic resonance spectroscopy to assess muscle metabolism. Results Patients with CF showed a reduced exercise capacity in the incremental cardiopulmonary cycling test (VO2peak: CF 77.8 ± 16.2\%predicted (36.5 ± 7.4 ml/qCSA/min), control 100.6 ± 18.8\%predicted (49.1 ± 11.4 ml/qCSA/min); p < 0.001), and deficits in anaerobic capacity reflected by the Wingate test (peak power: CF 537 ± 180 W, control 727 ± 186 W; mean power: CF 378 ± 127 W, control 486 ± 126 W; power drop CF 12 ± 5 W, control 8 ± 4 W. all: p < 0.001). In the knee-extension task, patients with CF achieved a significantly lower workload (p < 0.05). However, in a linear model analysing maximal work load of the incremental knee-extension task and results of the Wingate test, respectively, only muscle size and height, but not disease status (CF or not) contributed to explaining variance. In line with this finding, no differences were found in muscle metabolism reflected by intracellular pH and the ratio of Pi/PCr at submaximal stages and peak exercise measured through MRI spectroscopy. Conclusions The lower absolute muscle power in patients with CF compared to controls is exclusively explained by the reduced muscle size in this study. No evidence was found for an intrinsic skeletal muscle dysfunction due to primary alterations of muscle metabolism.}, language = {en} } @article{HeidenreichWengDonhauseretal.2019, author = {Heidenreich, Julius F. and Weng, Andreas M. and Donhauser, Julian and Greiser, Andreas and Chow, Kelvin and Nordbeck, Peter and Bley, Thorsten A. and K{\"o}stler, Herbert}, title = {T1- and ECV-mapping in clinical routine at 3 T: differences between MOLLI, ShMOLLI and SASHA}, series = {BMC Medical Imaging}, volume = {19}, journal = {BMC Medical Imaging}, doi = {10.1186/s12880-019-0362-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-201999}, pages = {59}, year = {2019}, abstract = {Background T1 mapping sequences such as MOLLI, ShMOLLI and SASHA make use of different technical approaches, bearing strengths and weaknesses. It is well known that obtained T1 relaxation times differ between the sequence techniques as well as between different hardware. Yet, T1 quantification is a promising tool for myocardial tissue characterization, disregarding the absence of established reference values. The purpose of this study was to evaluate the feasibility of native and post-contrast T1 mapping methods as well as ECV maps and its diagnostic benefits in a clinical environment when scanning patients with various cardiac diseases at 3 T. Methods Native and post-contrast T1 mapping data acquired on a 3 T full-body scanner using the three pulse sequences 5(3)3 MOLLI, ShMOLLI and SASHA in 19 patients with clinical indication for contrast enhanced MRI were compared. We analyzed global and segmental T1 relaxation times as well as respective extracellular volumes and compared the emerged differences between the used pulse sequences. Results T1 times acquired with MOLLI and ShMOLLI exhibited systematic T1 deviation compared to SASHA. Myocardial MOLLI T1 times were 19\% lower and ShMOLLI T1 times 25\% lower compared to SASHA. Native blood T1 times from MOLLI were 13\% lower than SASHA, while post-contrast MOLLI T1-times were only 5\% lower. ECV values exhibited comparably biased estimation with MOLLI and ShMOLLI compared to SASHA in good agreement with results reported in literature. Pathology-suspect segments were clearly differentiated from remote myocardium with all three sequences. Conclusion Myocardial T1 mapping yields systematically biased pre- and post-contrast T1 times depending on the applied pulse sequence. Additionally calculating ECV attenuates this bias, making MOLLI, ShMOLLI and SASHA better comparable. Therefore, myocardial T1 mapping is a powerful clinical tool for classification of soft tissue abnormalities in spite of the absence of established reference values.}, language = {en} } @article{StichPfaffWechetal.2020, author = {Stich, Manuel and Pfaff, Christiane and Wech, Tobias and Slawig, Anne and Ruyters, Gudrun and Dewdney, Andrew and Ringler, Ralf and K{\"o}stler, Herbert}, title = {The temperature dependence of gradient system response characteristics}, series = {Magnetic Resonance in Medicine}, volume = {83}, journal = {Magnetic Resonance in Medicine}, doi = {10.1002/mrm.28013}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-206212}, pages = {1519-1527}, year = {2020}, abstract = {Purpose: The gradient system transfer function (GSTF) characterizes the frequency transfer behavior of a dynamic gradient system and can be used to correct non-Cartesian k-space trajectories. This study analyzes the impact of the gradient coil temperature of a 3T scanner on the GSTF. Methods: GSTF self- and B\(_0\)-cross-terms were acquired for a 3T Siemens scanner (Siemens Healthcare, Erlangen, Germany) using a phantom-based measurement technique. The GSTF terms were measured for various temperature states up to 45°C. The gradient coil temperatures were measured continuously utilizing 12 temperature sensors which are integrated by the vendor. Different modeling approaches were applied and compared. Results: The self-terms depend linearly on temperature, whereas the B0-cross-term does not. Effects induced by thermal variation are negligible for the phase response. The self-terms are best represented by a linear model including the three gradient coil sensors that showed the maximum temperature dependence for the three axes. The use of time derivatives of the temperature did not lead to an improvement of the model. The B\(_0\)-cross-terms can be modeled by a convolution model which considers coil-specific heat transportation. Conclusion: The temperature dependency of the GSTF was analyzed for a 3T Siemens scanner. The self- and B0-cross-terms can be modeled using a linear and convolution modeling approach based on the three main temperature sensor elements.}, language = {en} } @article{WengKoestlerBleyetal.2021, author = {Weng, Andreas M. and K{\"o}stler, Herbert and Bley, Thorsten A. and Ritter, Christian O.}, title = {Effect of short-term smoking \& L-arginine on coronary endothelial function assessed by cardiac magnetic resonance cold pressor testing: a pilot study}, series = {BMC Cardiovascular Disorders}, volume = {21}, journal = {BMC Cardiovascular Disorders}, doi = {10.1186/s12872-021-02050-1}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-260559}, year = {2021}, abstract = {Background The effect of smoking on coronary vasomotion has been investigated in the past with various imaging techniques in both short- and long-term smokers. Additionally, coronary vasomotion has been shown to be normalized in long-term smokers by L-Arginine acting as a substrate for NO synthase, revealing the coronary endothelium as the major site of abnormal vasomotor response. Aim of the prospective cohort study was to investigate coronary vasomotion of young healthy short-term smokers via magnetic resonance cold pressor test with and without the administration of L-Arginine and compare obtained results with the ones from nonsmokers. Methods Myocardial blood flow (MBF) was quantified with first-pass perfusion MRI on a 1.5 T scanner in healthy short-term smokers (N = 10, age: 25.0 ± 2.8 years, 5.0 ± 2.9 pack years) and nonsmokers (N = 10, age: 34.3 ± 13.6) both at rest and during cold pressor test (CPT). Smokers underwent an additional examination after administration of L-Arginine within a median of 7 days of the na{\"i}ve examination. Results MBF at rest turned out to be 0.77 ± 0.30 (smokers with no L-Arginine; mean ± standard deviation), 0.66 ± 0.21 (smokers L-Arginine) and 0.84 ± 0.08 (nonsmokers). Values under CPT were 1.21 ± 0.42 (smokers no L-Arginine), 1.09 ± 0.35 (smokers L-Arginine) and 1.63 ± 0.33 (nonsmokers). In all groups, MBF was significantly increased under CPT compared to the corresponding rest examination (p < 0.05 in all cases). Additionally, MBF under CPT was significantly different between the smokers and the nonsmokers (p = 0.002). MBF at rest was significantly different between the smokers when L-Arginine was given and the nonsmokers (p = 0.035). Conclusion Short-term smokers showed a reduced response to cold both with and without the administration of L-Arginine. However, absolute MBF values under CPT were lower compared to nonsmokers independently of L-Arginine administration.}, language = {en} } @article{RichterWechWengetal.2020, author = {Richter, Julian A. J. and Wech, Tobias and Weng, Andreas M. and Stich, Manuel and Weick, Stefan and Breuer, Kathrin and Bley, Thorsten A. and K{\"o}stler, Herbert}, title = {Free-breathing self-gated 4D lung MRI using wave-CAIPI}, series = {Magnetic Resonance in Medicine}, volume = {84}, journal = {Magnetic Resonance in Medicine}, number = {6}, doi = {10.1002/mrm.28383}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-218075}, pages = {3223 -- 3233}, year = {2020}, abstract = {Purpose The aim of this study was to compare the wave-CAIPI (controlled aliasing in parallel imaging) trajectory to the Cartesian sampling for accelerated free-breathing 4D lung MRI. Methods The wave-CAIPI k-space trajectory was implemented in a respiratory self-gated 3D spoiled gradient echo pulse sequence. Trajectory correction applying the gradient system transfer function was used, and images were reconstructed using an iterative conjugate gradient SENSE (CG SENSE) algorithm. Five healthy volunteers and one patient with squamous cell carcinoma in the lung were examined on a clinical 3T scanner, using both sampling schemes. For quantitative comparison of wave-CAIPI and standard Cartesian imaging, the normalized mutual information and the RMS error between retrospectively accelerated acquisitions and their respective references were calculated. The SNR ratios were investigated in a phantom study. Results The obtained normalized mutual information values indicate a lower information loss due to acceleration for the wave-CAIPI approach. Average normalized mutual information values of the wave-CAIPI acquisitions were 10\% higher, compared with Cartesian sampling. Furthermore, the RMS error of the wave-CAIPI technique was lower by 19\% and the SNR was higher by 14\%. Especially for short acquisition times (down to 1 minute), the undersampled Cartesian images showed an increased artifact level, compared with wave-CAIPI. Conclusion The application of the wave-CAIPI technique to 4D lung MRI reduces undersampling artifacts, in comparison to a Cartesian acquisition of the same scan time. The benefit of wave-CAIPI sampling can therefore be traded for shorter examinations, or enhancing image quality of undersampled 4D lung acquisitions, keeping the scan time constant.}, language = {en} }