@article{KrieterRuethLemkeetal.2023, author = {Krieter, Detlef H. and R{\"u}th, Marieke and Lemke, Horst-Dieter and Wanner, Christoph}, title = {Clinical performance comparison of two medium cut-off dialyzers}, series = {Therapeutic Apheresis and Dialysis}, volume = {27}, journal = {Therapeutic Apheresis and Dialysis}, number = {2}, doi = {10.1111/1744-9987.13919}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-318643}, pages = {284 -- 292}, year = {2023}, abstract = {Introduction Medium-cut-off (MCO) dialyzers may beneficially impact outcomes in patients on hemodialysis. Methods In a randomized, controlled trial in maintenance hemodialysis patients, the new Nipro ELISIO-17HX MCO dialyzer was compared to the Baxter Theranova 400 filter regarding middle molecule removal. Furthermore, the suitability of two assays for free lambda-light chain (λFLC) detection (Freelite vs. N-Latex) was verified. Results ELISIO-HX achieved slightly lower reduction ratios for β2-microglobulin (71.8 ± 6.0 vs. 75.3 ± 5.8\%; p = 0.001), myoglobin (54.7 ± 8.6 vs. 64.9 ± 8.7\%; p < 0.001), and kappa-FLC (62.1 ± 8.8 vs. 56.3 ± 7.7\%; p = 0.021). λFLC reduction ratios were more conclusive with the Freelite assay and not different between ELISIO-HX and Theranova (28.4 ± 3.9 vs. 38.7 ± 13.4\%; p = 0.069). The albumin loss of Theranova was considerably higher (2.14 ± 0.45 vs. 0.77 ± 0.25 g; p = 0.001) and the Global Removal ScoreLoss alb largely inferior (30.6 ± 7.4 vs. 82.4 ± 29.2\%/g; p = 0.006) to ELISIO-HX. Conclusions The new ELISIO-HX expands the choice of dialyzers for MCO hemodialysis.}, language = {en} } @article{GrebeMalzahnDonhauseretal.2020, author = {Grebe, S{\"o}ren Jendrik and Malzahn, Uwe and Donhauser, Julian and Liu, Dan and Wanner, Christoph and Krane, Vera and Hammer, Fabian}, title = {Quantification of left ventricular mass by echocardiography compared to cardiac magnet resonance imaging in hemodialysis patients}, series = {Cardiovascular Ultrasound}, volume = {18}, journal = {Cardiovascular Ultrasound}, doi = {10.1186/s12947-020-00217-y}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-229282}, year = {2020}, abstract = {Background: Left ventricular hypertrophy (LVH), defined by the left ventricular mass index (LVMI), is highly prevalent in hemodialysis patients and a strong independent predictor of cardiovascular events. Compared to cardiac magnetic resonance imaging (CMR), echocardiography tends to overestimate the LVMI. Here, we evaluate the diagnostic performance of transthoracic echocardiography (TTE) compared to CMR regarding the assessment of LVMI in hemodialysis patients. Methods: TTR and CMR data for 95 hemodialysis patients who participated in the MiREnDa trial were analyzed. The LVMI was calculated by two-dimensional (2D) TTE-guided M-mode measurements employing the American Society of Echocardiography (ASE) and Teichholz (Th) formulas, which were compared to the reference method, CMR. Results: LVH was present in 44\% of patients based on LVMI measured by CMR. LVMI measured by echocardiography correlated moderately with CMR, ASE: r = 0.44 (0.34-0.62); Th: r = 0.44 (0.32-0.62). Compared to CMR, both echocardiographic formulas overestimated LVMI (mean increment LVMI (ASE-CMR): 19.5 +/- 19.48 g/m(2),p < 0.001; mean increment LVMI (Th-CMR): 15.9 +/- 15.89 g/m(2),p < 0.001). We found greater LVMI overestimation in patients with LVH using the ASE formula compared to the Th formula. Stratification of patients into CMR LVMI quartiles showed a continuous decrease in increment LVMI with increasing CMR LVMI quartiles for the Th formula (p < 0.001) but not for the ASE formula (p = 0.772). Bland-Altman analysis showed that the Th formula had a constant bias independent of LVMI. Both methods had good discrimination ability for the detection of LVH (ROC-AUC: 0.819 (0.737-0.901) and 0.808 (0.723-0.892) for Th and ASE, respectively). Conclusions: The ASE and Th formulas overestimate LVMI in hemodialysis patients. However, the overestimation is less with the Th formula, particularly with increasing LVMI. The results suggest that the Th formula should be preferred for measurement of LVMI in chronic hemodialysis patients.}, language = {en} } @article{KrieterKerwagenRuethetal.2019, author = {Krieter, Detlef H. and Kerwagen, Simon and R{\"u}th, Marieke and Lemke, Horst-Dieter and Wanner, Christoph}, title = {Differences in dialysis efficacy have limited effects on protein-bound uremic toxins plasma levels over time}, series = {Toxins}, volume = {11}, journal = {Toxins}, number = {4}, doi = {10.3390/toxins11010047}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-201770}, pages = {47}, year = {2019}, abstract = {The protein-bound uremic toxins para-cresyl sulfate (pCS) and indoxyl sulfate (IS) are associated with cardiovascular disease in chronic renal failure, but the effect of different dialysis procedures on their plasma levels over time is poorly studied. The present prospective, randomized, cross-over trial tested dialysis efficacy and monitored pre-treatment pCS and IS concentrations in 15 patients on low-flux and high-flux hemodialysis and high-convective volume postdilution hemodiafiltration over six weeks each. Although hemodiafiltration achieved by far the highest toxin removal, only the mean total IS level was decreased at week three (16.6 ± 12.1 mg/L) compared to baseline (18.9 ± 13.0 mg/L, p = 0.027) and to low-flux dialysis (20.0 ± 12.7 mg/L, p = 0.021). At week six, the total IS concentration in hemodiafiltration reached the initial values again. Concentrations of free IS and free and total pCS remained unaltered. Highest beta2-microglobulin elimination in hemodiafiltration (p < 0.001) led to a persistent decrease of the plasma levels at week three and six (each p < 0.001). In contrast, absent removal in low-flux dialysis resulted in rising beta2-microglobulin concentrations (p < 0.001). In conclusion, this trial demonstrated that even large differences in instantaneous protein-bound toxin removal by current extracorporeal dialysis techniques may have only limited impact on IS and pCS plasma levels in the longer term.}, language = {en} } @article{ReineckeJuergensmeyerEngelbertzetal.2018, author = {Reinecke, Holger and J{\"u}rgensmeyer, Sabine and Engelbertz, Christiane and Gerss, Joachim and Kirchhof, Paulus and Breithardt, G{\"u}nter and Bauersachs, Rupert and Wanner, Christoph}, title = {Design and rationale of a randomised controlled trial comparing apixaban to phenprocoumon in patients with atrial fibrillation on chronic haemodialysis: the AXADIA-AFNET 8 study}, series = {BMJ open}, volume = {8}, journal = {BMJ open}, number = {9}, doi = {10.1136/bmjopen-2018-022690}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-225156}, pages = {e022690, 1-10}, year = {2018}, abstract = {Introduction Patients with end-stage kidney disease requiring maintenance haemodialysis treatment experience a dramatic cardiovascular morbidity and mortality. Due to the high atherosclerotic and arteriosclerotic burden and profound alterations in haemostasis, they frequently suffer and die from both thromboembolic and bleeding events. This is a particular concern in patients on haemodialysis with atrial fibrillation (AF). Controlled trials on the optimal anticoagulation in patients with AF on haemodialysis are not available. The randomised controlled phase IIIb AXADIA-AFNET 8 trial will evaluate the safety and efficacy of the factor Xa inhibitor apixaban in patients with AF requiring haemodialysis. Methods and analysis A total of 222 patients will be randomised in an open-labelled, 1:1 design to receive either apixaban 2.5mg twice daily or dose-adjusted vitamin K antagonist therapy (target international normalised ratio 2.0-3.0). All patients will be treated and followed up for a minimum of 6 months up to a maximum of 24 months. The primary outcome is major or clinically relevant, non-major bleedings or death of any cause. Secondary outcomes include stroke, cardiovascular death and other thromboembolic events, thus exploring the efficacy of apixaban. The first patient was randomised in June 2017. Ethics and dissemination The study protocol was approved by the Ethical Committee of the Landesaertzekammer, Westfalen-Lippe and the Medical Faculty of the University of Muenster, Muenster, Germany (reference number: 2016-598f-A). Written informed consent will be obtained from all patients prior to study participation, including their consent for long-term follow-up. AXADIA-AFNET 8 is an investigator-initiated trial. Sponsor is AFNET, Muenster, Germany. Study findings will be disseminated to Bristol-Myers Squibb, Munich, Germany, and Pfizer, Berlin, Germany, to the participating centres, at research conferences and in peer-reviewed journals. Trial registration numbers NCT02933697, Pre-results.}, language = {en} } @article{SchneiderSchneiderKrieteretal.2015, author = {Schneider, Andreas and Schneider, Markus P. and Krieter, Detlef H. and Genser, Bernd and Scharnagl, Hubert and Stojakovic, Tatjana and Wanner, Christoph and Drechsler, Christiane}, title = {Effect of high-flux dialysis on circulating FGF-23 levels in end-stage renal disease patients: results from a randomized trial}, series = {PLoS ONE}, volume = {10}, journal = {PLoS ONE}, number = {5}, doi = {10.1371/journal.pone.0128079}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-148559}, pages = {e0128079}, year = {2015}, abstract = {Background In patients undergoing maintenance hemodialysis (HD), increased levels of circulating fibroblast growth factor-23 (FGF-23) are independently associated with cardiovascular events and mortality. Interventional strategies aiming to reduce levels of FGF-23 in HD patients are of particular interest. The purpose of the current study was to compare the impact of high-flux versus low-flux HD on circulating FGF-23 levels. Methods We conducted a post-hoc analysis of the MINOXIS study, including 127 dialysis patients randomized to low-flux (n = 62) and high-flux (n = 65) HD for 52 weeks. Patients with valid measures for FGF-23 investigated baseline and after 52 weeks were included. Results Compared to baseline, a significant increase in FGF-23 levels after one year of low-flux HD was observed (Delta plasma FGF-23: +4026 RU/ml; p < 0.001). In contrast, FGF-23 levels remained stable in the high flux group (Delta plasma FGF-23: +373 RU/ml, p = 0.70). The adjusted difference of the absolute change in FGF-23 levels between the two treatment groups was statistically significant (p < 0.01). Conclusions Over a period of 12 months, high-flux HD was associated with stable FGF-23 levels, whereas the low-flux HD group showed an increase of FGF-23. However, the implications of the different FGF 23 time-trends in patients on high flux dialysis, as compared to the control group, remain to be explored in specifically designed clinical trials.}, language = {en} }