@article{MirallesVargiuDauwalderetal.2015, author = {Miralles, Felip and Vargiu, Eloisa and Dauwalder, Stefan and Sol{\`a}, Marc and M{\"u}ller-Putz, Gernot and Wriessnegger, Selina C. and Pinegger, Andreas and K{\"u}bler, Andrea and Halder, Sebastian and K{\"a}thner, Ivo and Martin, Suzanne and Daly, Jean and Armstrong, Elaine and Guger, Christoph and Hinterm{\"u}ller, Christoph and Lowish, Hannah}, title = {Brain computer interface on track to home.}, series = {The Scientific World Journal}, volume = {2015}, journal = {The Scientific World Journal}, number = {623896}, doi = {10.1155/2015/623896}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-149575}, year = {2015}, abstract = {The novel BackHome system offers individuals with disabilities a range of useful services available via brain-computer interfaces (BCIs), to help restore their independence. This is the time such technology is ready to be deployed in the real world, that is, at the target end users' home. This has been achieved by the development of practical electrodes, easy to use software, and delivering telemonitoring and home support capabilities which have been conceived, implemented, and tested within a user-centred design approach. The final BackHome system is the result of a 3-year long process involving extensive user engagement to maximize effectiveness, reliability, robustness, and ease of use of a home based BCI system. The system is comprised of ergonomic and hassle-free BCI equipment; one-click software services for Smart Home control, cognitive stimulation, and web browsing; and remote telemonitoring and home support tools to enable independent home use for nonexpert caregivers and users. BackHome aims to successfully bring BCIs to the home of people with limited mobility to restore their independence and ultimately improve their quality of life.}, language = {en} } @article{KaethnerHalderHintermuelleretal.2017, author = {K{\"a}thner, Ivo and Halder, Sebastian and Hinterm{\"u}ller, Christoph and Espinosa, Arnau and Guger, Christoph and Miralles, Felip and Vargiu, Eloisa and Dauwalder, Stefan and Rafael-Palou, Xavier and Sol{\`a}, Marc and Daly, Jean M. and Armstrong, Elaine and Martin, Suzanne and K{\"u}bler, Andrea}, title = {A Multifunctional Brain-Computer Interface Intended for Home Use: An Evaluation with Healthy Participants and Potential End Users with Dry and Gel-Based Electrodes}, series = {Frontiers in Neuroscience}, volume = {11}, journal = {Frontiers in Neuroscience}, number = {286}, doi = {10.3389/fnins.2017.00286}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-157925}, year = {2017}, abstract = {Current brain-computer interface (BCIs) software is often tailored to the needs of scientists and technicians and therefore complex to allow for versatile use. To facilitate home use of BCIs a multifunctional P300 BCI with a graphical user interface intended for non-expert set-up and control was designed and implemented. The system includes applications for spelling, web access, entertainment, artistic expression and environmental control. In addition to new software, it also includes new hardware for the recording of electroencephalogram (EEG) signals. The EEG system consists of a small and wireless amplifier attached to a cap that can be equipped with gel-based or dry contact electrodes. The system was systematically evaluated with a healthy sample, and targeted end users of BCI technology, i.e., people with a varying degree of motor impairment tested the BCI in a series of individual case studies. Usability was assessed in terms of effectiveness, efficiency and satisfaction. Feedback of users was gathered with structured questionnaires. Two groups of healthy participants completed an experimental protocol with the gel-based and the dry contact electrodes (N = 10 each). The results demonstrated that all healthy participants gained control over the system and achieved satisfactory to high accuracies with both gel-based and dry electrodes (average error rates of 6 and 13\%). Average satisfaction ratings were high, but certain aspects of the system such as the wearing comfort of the dry electrodes and design of the cap, and speed (in both groups) were criticized by some participants. Six potential end users tested the system during supervised sessions. The achieved accuracies varied greatly from no control to high control with accuracies comparable to that of healthy volunteers. Satisfaction ratings of the two end-users that gained control of the system were lower as compared to healthy participants. The advantages and disadvantages of the BCI and its applications are discussed and suggestions are presented for improvements to pave the way for user friendly BCIs intended to be used as assistive technology by persons with severe paralysis.}, language = {en} } @article{LugoQuitadamoBianchietal.2016, author = {Lugo, Zulay R. and Quitadamo, Lucia R. and Bianchi, Luigi and Pellas, Fr{\´e}deric and Veser, Sandra and Lesenfants, Damien and Real, Ruben G. L. and Herbert, Cornelia and Guger, Christoph and Kotchoubey, Boris and Mattia, Donatella and K{\"u}bler, Andrea and Laureys, Steven and Noirhomme, Quentin}, title = {Cognitive Processing in Non-Communicative Patients: What Can Event-Related Potentials Tell Us?}, series = {Frontiers in Human Neuroscience}, volume = {10}, journal = {Frontiers in Human Neuroscience}, number = {569}, doi = {10.3389/fnhum.2016.00569}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-165165}, year = {2016}, abstract = {Event-related potentials (ERP) have been proposed to improve the differential diagnosis of non-responsive patients. We investigated the potential of the P300 as a reliable marker of conscious processing in patients with locked-in syndrome (LIS). Eleven chronic LIS patients and 10 healthy subjects (HS) listened to a complex-tone auditory oddball paradigm, first in a passive condition (listen to the sounds) and then in an active condition (counting the deviant tones). Seven out of nine HS displayed a P300 waveform in the passive condition and all in the active condition. HS showed statistically significant changes in peak and area amplitude between conditions. Three out of seven LIS patients showed the P3 waveform in the passive condition and five of seven in the active condition. No changes in peak amplitude and only a significant difference at one electrode in area amplitude were observed in this group between conditions. We conclude that, in spite of keeping full consciousness and intact or nearly intact cortical functions, compared to HS, LIS patients present less reliable results when testing with ERP, specifically in the passive condition. We thus strongly recommend applying ERP paradigms in an active condition when evaluating consciousness in non-responsive patients.}, language = {en} } @misc{FazelRezaiAllisonGugeretal.2012, author = {Fazel-Rezai, Reza and Allison, Brendan Z. and Guger, Christoph and Sellers, Eric W. and Kleih, Sonja C. and K{\"u}bler, Andrea}, title = {P300 brain computer interface: current challenges and emerging trends}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-75941}, year = {2012}, abstract = {A brain-computer interface (BCI) enables communication without movement based on brain signals measured with electroencephalography (EEG). BCIs usually rely on one of three types of signals: the P300 and other components of the event-related potential (ERP), steady state visual evoked potential (SSVEP), or event related desynchronization (ERD). Although P300 BCIs were introduced over twenty years ago, the past few years have seen a strong increase in P300 BCI research. This closed-loop BCI approach relies on the P300 and other components of the ERP, based on an oddball paradigm presented to the subject. In this paper, we overview the current status of P300 BCI technology, and then discuss new directions: paradigms for eliciting P300s; signal processing methods; applications; and hybrid BCIs. We conclude that P300 BCIs are quite promising, as several emerging directions have not yet been fully explored and could lead to improvements in bit rate, reliability, usability, and flexibility.}, subject = {Psychologie}, language = {en} }