@article{BraunschweigDewhurstSchwabetal.2010, author = {Braunschweig, Holger and Dewhurst, Rian D. and Schwab, Katrin and Wagner, Katharina}, title = {{N ',N ''-Bis[2,6-bis(1-methylethyl)phenyl]-N,N-dimethylguanidinato-kappa N-2 ',N ''}dibromidoborane}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-67622}, year = {2010}, abstract = {In the molecular structure of the title compound, C27H40N3BBr2, the B atom is connected to two bromide substituents and a guanidinate scaffold, forming a four- membered ring. An aryl group is connected to each N atom in the ring that contains two isopropyl groups in positions 2 and 6.}, subject = {Anorganische Chemie}, language = {en} } @phdthesis{Wagner2010, author = {Wagner, Katrin}, title = {Manuelle versus automatisierte Bestimmung von Schilddr{\"u}senantik{\"o}rpern: Vergleich des VarELISA mit dem KRYPTOR}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-52011}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2010}, abstract = {In dieser Studie wurden zwei Immunoassays zur Bestimmung von TG- und TPO-Antik{\"o}rpern hinsichtlich diagnostischer Trennsch{\"a}rfe sowie klinischer Relevanz in der Diagnostik der chronischen lymphozyt{\"a}ren Thyreoiditis-Hashimoto (CLT) untersucht. Im Rahmen der vorliegenden Studie wurden zwei Patientengruppen erfasst: ein Kollektiv mit der Diagnose CLT (n=203) und das sogenannte Normalkollektiv, das 205 Probanden umfasste. Die diagnostischen Kriterien zur Diagnosestellung CLT ergaben sich aus dem Zusammenspiel von klinischem Befund, Ultraschalluntersuchung und Antik{\"o}rpertiter. Verglichen wurden der an der Klinik und Poliklinik f{\"u}r Nuklearmedizin der Universit{\"a}t W{\"u}rzburg f{\"u}r die Routinediagnostik eingesetzte manuelle VarELISA TG und TPO Antibodies Assay, PHARMACIA Diagnostics mit dem automatisierten BRAHMS anti-TGn bzw. anti-TPOn KRYPTOR Assay. Die Bestimmung der Ergebnisse bei TPO-AK zeigte, dass die von KRYPTOR gemessenen Werte im Mittel um 2670,51 U/ml h{\"o}her lagen als bei VarELISA. Bei TG-AK wurden die Konzentrationen auf der Plattform KRYPTOR allerdings um 325,07 U/ml niedriger gemessen als bei VarELISA; es zeigte sich bei TG-AK somit ein umgekehrtes Verh{\"a}ltnis. Des Weiteren wurde eine relativ gute {\"U}bereinstimmung zwischen beiden Assays (Kappa-Koeffizient nach Cohen = 0,63) bei der Bestimmung der TPO-Antik{\"o}rper festgestellt; 86,8\% der Seren wurden als konkordant bewertet. Demgegen{\"u}ber stehen 65,4\% in ihrem subjektiven Urteil {\"u}bereinstimmende Ergebnisse bei der TG-Antik{\"o}rper Bestimmung, was f{\"u}r eine schwache {\"U}bereinstimmung der TG-AK-Werte spricht (Kappa-Koeffizient nach Cohen = 0,31). Zudem ist die diagnostische Trennsch{\"a}rfe bei TPO-AK h{\"o}her (Area under Curve = 0,929) als bei TG-AK (Area under Curve = 0,805); somit unterscheidet KRYPTOR bei der Bestimmung der TPO-AK besser zwischen „gesunden" und „erkrankten" Patienten als VarELISA. Bei der Messung der TPO-AK auf der Plattform KRYPTOR zeigte sich bei dem dem Cut-Off (vom Hersteller auf 60 U/ml festgelegt) am n{\"a}chsten liegenden Wert (59,9 U/ml) sowohl eine hohe Sensitivit{\"a}t (81,4\%) als auch Spezifit{\"a}t (97,6\%). Bei der TG-AK Messung lag bei dem Cut-Off Wert von 59,8 U/ml bei hoher Spezifit{\"a}t (99,5\%) die Sensitivit{\"a}t sehr niedrig (43,6\%), d.h. viele Patienten wurden als falsch negativ eingestuft. Aus der Auswertung geht ein optimaler Schwellenwert von 67,2 U/ml f{\"u}r TPO-AK und 40,7 U/ml f{\"u}r TG-AK hervor, wobei der vom Hersteller angegebene Cut-Off Wert f{\"u}r beide AK 60 U/ml betr{\"a}gt. Mittels neu ermitteltem Cut-Off Wert (67,2 U/ml) konnte bei TPO-AK eine Steigerung der Spezifit{\"a}t auf 99,5\% bei unver{\"a}nderter Sensitivit{\"a}t erreicht werden. Dementsprechend erbrachte der Cut-Off Wert von 40,7 U/ml eine Steigerung der Sensitiv{\"a}t auf 50\% bei gleich bleibender Spezifit{\"a}t bei TG-AK. Die Bestimmung des Antik{\"o}rperprofils in den beiden Testsystemen zeigte somit, insbesondere bei TG-AK, h{\"a}ufig diskrepante Ergebnisse. Dies belegt erneut die bekannte Problematik bei der Labordiagnostik der CLT. Urs{\"a}chlich sind Affinit{\"a}tsunterschiede und unterschiedliche Kalibrierungen der verwendeten Tests sowie das Fehlen einer Standardisierung zu diskutieren. Dar{\"u}ber hinaus best{\"a}tigen die Ergebnisse die Notwendigkeit einer Definition eines institutionellen Cut-Offs.}, subject = {Schilddr{\"u}se}, language = {de} } @article{WagnerWannerSchichetal.2017, author = {Wagner, Martin and Wanner, Christoph and Schich, Martin and Kotseva, Kornelia and Wood, David and Hartmann, Katrin and Fette, Georg and R{\"u}cker, Viktoria and Oezkur, Mehmet and St{\"o}rk, Stefan and Heuschmann, Peter U.}, title = {Patient's and physician's awareness of kidney disease in coronary heart disease patients - a cross-sectional analysis of the German subset of the EUROASPIRE IV survey}, series = {BMC Nephrology}, volume = {18}, journal = {BMC Nephrology}, number = {321}, doi = {10.1186/s12882-017-0730-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-158387}, year = {2017}, abstract = {Background Chronic kidney disease (CKD) is a common comorbid condition in coronary heart disease (CHD). CKD predisposes the patient to acute kidney injury (AKI) during hospitalization. Data on awareness of kidney dysfunction among CHD patients and their treating physicians are lacking. In the current cross-sectional analysis of the German EUROASPIRE IV sample we aimed to investigate the physician's awareness of kidney disease of patients hospitalized for CHD and also the patient's awareness of CKD in a study visit following hospital discharge. Methods All serum creatinine (SCr) values measured during the hospital stay were used to describe impaired kidney function (eGFR\(_{CKD-EPI}\) < 60 ml/min/1.73m2) at admission, discharge and episodes of AKI (KDIGO definition). Information extracted from hospital discharge letters and correct ICD coding for kidney disease was studied as a surrogate of physician's awareness of kidney disease. All patients were interrogated 0.5 to 3 years after hospital discharge, whether they had ever been told about kidney disease by a physician. Results Of the 536 patients, 32\% had evidence for acute or chronic kidney disease during the index hospital stay. Either condition was mentioned in the discharge letter in 22\%, and 72\% were correctly coded according to ICD-10. At the study visit in the outpatient setting 35\% had impaired kidney function. Of 158 patients with kidney disease, 54 (34\%) were aware of CKD. Determinants of patient's awareness were severity of CKD (OR\(_{eGFR}\) 0.94; 95\%CI 0.92-0.96), obesity (OR 1.97; 1.07-3.64), history of heart failure (OR 1.99; 1.00-3.97), and mentioning of kidney disease in the index event's hospital discharge letter (OR 5.51; 2.35-12.9). Conclusions Although CKD is frequent in CHD, only one third of patients is aware of this condition. Patient's awareness was associated with kidney disease being mentioned in the hospital discharge letter. Future studies should examine how raising physician's awareness for kidney dysfunction may improve patient's awareness of CKD.}, language = {en} } @article{IckrathWagnerScherzadetal.2017, author = {Ickrath, Pascal and Wagner, Martin and Scherzad, Agmal and Gehrke, Thomas and Burghartz, Marc and Hagen, Rudolf and Radeloff, Katrin and Kleinsasser, Norbert and Hackenberg, Stephan}, title = {Time-Dependent Toxic and Genotoxic Effects of Zinc Oxide Nanoparticles after Long-Term and Repetitive Exposure to Human Mesenchymal Stem Cells}, series = {International Journal of Environmental Research and Public Health}, volume = {14}, journal = {International Journal of Environmental Research and Public Health}, number = {12}, doi = {10.3390/ijerph14121590}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-169932}, pages = {1590}, year = {2017}, abstract = {Zinc oxide nanoparticles (ZnO-NP) are widely spread in consumer products. Data about the toxicological characteristics of ZnO-NP is still under controversial discussion. The human skin is the most important organ concerning ZnO-NP exposure. Intact skin was demonstrated to be a sufficient barrier against NPs; however, defect skin may allow NP contact to proliferating cells. Within these cells, stem cells are the most important toxicological target for NPs. The aim of this study was to evaluate the genotoxic and cytotoxic effects of ZnO-NP at low-dose concentrations after long-term and repetitive exposure to human mesenchymal stem cells (hMSC). Cytotoxic effects of ZnO-NP were measured by the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay. Furthermore, genotoxicity was evaluated by the comet assay. For long-term observation over 6 weeks, transmission electron microscopy (TEM) was applied. The results of the study indicated cytotoxic effects of ZnO-NP beginning at high concentrations of 50 μg/mL and genotoxic effects in hMSC exposed to 1 and 10 μg/mL ZnO-NP. Repetitive exposure enhanced cyto- but not genotoxicity. Intracellular NP accumulation was observed up to 6 weeks. The results suggest cytotoxic and genotoxic potential of ZnO-NP. Even low doses of ZnO-NP may induce toxic effects as a result of repetitive exposure and long-term cellular accumulation. This data should be considered before using ZnO-NP on damaged skin.}, language = {en} }