@article{KreisslHaenscheidLoehretal.2012, author = {Kreissl, Michael C. and H{\"a}nscheid, Heribert and L{\"o}hr, Mario and Verburg, Frederik A. and Schiller, Markus and Lassmann, Michael and Reiners, Christoph and Samnick, Samuel S. and Buck, Andreas K. and Flentje, Michael and Sweeney, Reinhart A.}, title = {Combination of peptide receptor radionuclide therapy with fractionated external beam radiotherapy for treatment of advanced symptomatic meningioma}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-75540}, year = {2012}, abstract = {Background: External beam radiotherapy (EBRT) is the treatment of choice for irresectable meningioma. Due to the strong expression of somatostatin receptors, peptide receptor radionuclide therapy (PRRT) has been used in advanced cases. We assessed the feasibility and tolerability of a combination of both treatment modalities in advanced symptomatic meningioma. Methods: 10 patients with irresectable meningioma were treated with PRRT (177Lu-DOTA0,Tyr3 octreotate or - DOTA0,Tyr3 octreotide) followed by external beam radiotherapy (EBRT). EBRT performed after PRRT was continued over 5-6 weeks in IMRT technique (median dose: 53.0 Gy). All patients were assessed morphologically and by positron emission tomography (PET) before therapy and were restaged after 3-6 months. Side effects were evaluated according to CTCAE 4.0. Results: Median tumor dose achieved by PRRT was 7.2 Gy. During PRRT and EBRT, no side effects>CTCAE grade 2 were noted. All patients reported stabilization or improvement of tumor-associated symptoms, no morphologic tumor progression was observed in MR-imaging (median follow-up: 13.4 months). The median pre-therapeutic SUVmax in the meningiomas was 14.2 (range: 4.3-68.7). All patients with a second PET after combined PRRT + EBRT showed an increase in SUVmax (median: 37\%; range: 15\%-46\%) to a median value of 23.7 (range: 8.0-119.0; 7 patients) while PET-estimated volume generally decreased to 81 ± 21\% of the initial volume. Conclusions: The combination of PRRT and EBRT is feasible and well tolerated. This approach represents an attractive strategy for the treatment of recurring or progressive symptomatic meningioma, which should be further evaluated.}, subject = {Medizin}, language = {en} } @article{WernerWeichHiguchietal.2017, author = {Werner, Rudolf A. and Weich, Alexander and Higuchi, Takahiro and Schmid, Jan S. and Schirbel, Andreas and Lassmann, Michael and Wild, Vanessa and Rudelius, Martina and Kudlich, Theodor and Herrmann, Ken and Scheurlen, Michael and Buck, Andreas K. and Kropf, Saskia and Wester, Hans-J{\"u}rgen and Lapa, Constantin}, title = {Imaging of Chemokine Receptor 4 Expression in Neuroendocrine Tumors - a Triple Tracer Comparative Approach}, series = {Theranostics}, volume = {7}, journal = {Theranostics}, number = {6}, doi = {10.7150/thno.18754}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-158008}, pages = {1489-1498}, year = {2017}, abstract = {C-X-C motif chemokine receptor 4 (CXCR4) and somatostatin receptors (SSTR) are overexpressed in gastro-entero-pancreatic neuroendocrine tumors (GEP-NET). In this study, we aimed to elucidate the feasibility of non-invasive CXCR4 positron emission tomography/computed tomography (PET/CT) imaging in GEP-NET patients using [\(^{68}\)Ga]Pentixafor in comparison to \(^{68}\)Ga-DOTA-D-Phe-Tyr3-octreotide ([\(^{68}\)Ga]DOTATOC) and \(^{18}\)F-fluorodeoxyglucose ([\(^{18}\)F]FDG). Twelve patients with histologically proven GEP-NET (3xG1, 4xG2, 5xG3) underwent [\(^{68}\)Ga]DOTATOC, [\(^{18}\)F]FDG, and [\(^{68}\)Ga]Pentixafor PET/CT for staging and planning of the therapeutic management. Scans were analyzed on a patient as well as on a lesion basis and compared to immunohistochemical staining patterns of CXCR4 and somatostatin receptors SSTR2a and SSTR5. [\(^{68}\)Ga]Pentixafor visualized tumor lesions in 6/12 subjects, whereas [\(^{18}\)F]FDG revealed sites of disease in 10/12 and [\(^{68}\)Ga]DOTATOC in 11/12 patients, respectively. Regarding sensitivity, SSTR-directed PET was the superior imaging modality in all G1 and G2 NET. CXCR4-directed PET was negative in all G1 NET. In contrast, 50\% of G2 and 80\% of G3 patients exhibited [\(^{68}\)Ga]Pentixafor-positive tumor lesions. Whereas CXCR4 seems to play only a limited role in detecting well-differentiated NET, increasing receptor expression could be non-invasively observed with increasing tumor grade. Thus, [\(^{68}\)Ga]Pentixafor PET/CT might serve as non-invasive read-out for evaluating the possibility of CXCR4-directed endoradiotherapy in advanced dedifferentiated SSTR-negative tumors.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{WernerBeykanHiguchietal.2016, author = {Werner, Rudolf A. and Beykan, Seval and Higuchi, Takahiro and L{\"u}ckerath, Katharina and Weich, Alexander and Scheurlen, Michael and Bluemel, Christina and Herrmann, Ken and Buck, Andreas K. and Lassmann, Michael and Lapa, Constantin and H{\"a}nscheid, Heribert}, title = {The impact of \(^{177}\)Lu-octreotide therapy on \(^{99m}\)Tc-MAG3 clearance is not predictive for late nephropathy}, series = {Oncotarget}, volume = {7}, journal = {Oncotarget}, number = {27}, doi = {10.18632/oncotarget.9775}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-177318}, pages = {41233-41241}, year = {2016}, abstract = {Peptide Receptor Radionuclide Therapy (PRRT) for the treatment of neuroendocrine tumors may lead to kidney deterioration. This study aimed to evaluate the suitability of \(^{99m}\)Tc-mercaptoacetyltriglycine (\(^{99m}\)Tc-MAG3) clearance for the early detection of PRRT-induced changes on tubular extraction (TE). TE rate (TER) was measured prior to 128 PRRT cycles (7.6±0.4 GBq \(^{177}\)Lu-octreotate/octreotide each) in 32 patients. TER reduction during PRRT was corrected for age-related decrease and analyzed for the potential to predict loss of glomerular filtration (GF). The GF rate (GFR) as measure for renal function was derived from serum creatinine. The mean TER was 234 ± 53 ml/min/1.73 m² before PRRT (baseline) and 221 ± 45 ml/min/1.73 m² after a median follow-up of 370 days. The age-corrected decrease (mean: -3\%, range: -27\% to +19\%) did not reach significance (p=0.09) but significantly correlated with the baseline TER (Spearman p=-0.62, p<0.001). Patients with low baseline TER showed an improved TER after PRRT, high decreases were only observed in individuals with high baseline TER. Pre-therapeutic TER data were inferior to plasma creatinine-derived GFR estimates in predicting late nephropathy. TER assessed by \(^{99m}\)Tc-MAG3­clearance prior to and during PRRT is not suitable as early predictor of renal injury and an increased risk for late nephropathy.}, language = {en} } @article{ScherthanLeeMausetal.2019, author = {Scherthan, Harry and Lee, Jin-Ho and Maus, Emanuel and Schumann, Sarah and Muhtadi, Razan and Chojowski, Robert and Port, Matthias and Lassmann, Michael and Bestvater, Felix and Hausmann, Michael}, title = {Nanostructure of clustered DNA damage in leukocytes after in-solution irradiation with the alpha emitter Ra-223}, series = {Cancers}, volume = {11}, journal = {Cancers}, number = {12}, issn = {2072-6694}, doi = {10.3390/cancers11121877}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-193038}, year = {2019}, abstract = {Background: Cancer patients are increasingly treated with alpha-particle-emitting radiopharmaceuticals. At the subcellular level, alpha particles induce densely spaced ionizations and molecular damage. Induction of DNA lesions, especially clustered DNA double-strand breaks (DSBs), threatens a cell's survival. Currently, it is under debate to what extent the spatial topology of the damaged chromatin regions and the repair protein arrangements are contributing. Methods: Super-resolution light microscopy (SMLM) in combination with cluster analysis of single molecule signal-point density regions of DSB repair markers was applied to investigate the nano-structure of DNA damage foci tracks of Ra-223 in-solution irradiated leukocytes. Results: Alpha-damaged chromatin tracks were efficiently outlined by γ-H2AX that formed large (super) foci composed of numerous 60-80 nm-sized nano-foci. Alpha damage tracks contained 60-70\% of all γ-H2AX point signals in a nucleus, while less than 30\% of 53BP1, MRE11 or p-ATM signals were located inside γ-H2AX damage tracks. MRE11 and p-ATM protein fluorescent tags formed focal nano-clusters of about 20 nm peak size. There were, on average, 12 (±9) MRE11 nanoclusters in a typical γ-H2AX-marked alpha track, suggesting a minimal number of MRE11-processed DSBs per track. Our SMLM data suggest regularly arranged nano-structures during DNA repair in the damaged chromatin domain.}, language = {en} } @article{TranGiaDenisBacelarFerreiraetal.2021, author = {Tran-Gia, Johannes and Denis-Bacelar, Ana M. and Ferreira, Kelley M. and Robinson, Andrew P. and Calvert, Nicholas and Fenwick, Andrew J. and Finocchiaro, Domenico and Fioroni, Federica and Grassi, Elisa and Heetun, Warda and Jewitt, Stephanie J. and Kotzassarlidou, Maria and Ljungberg, Michael and McGowan, Daniel R. and Scott, Nathaniel and Scuffham, James and Gleisner, Katarina Sj{\"o}green and Tipping, Jill and Wevrett, Jill and Lassmann, Michael}, title = {A multicentre and multi-national evaluation of the accuracy of quantitative Lu-177 SPECT/CT imaging performed within the MRTDosimetry project}, series = {EJNMMI Physics}, volume = {8}, journal = {EJNMMI Physics}, doi = {10.1186/s40658-021-00397-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-270380}, year = {2021}, abstract = {Purpose Patient-specific dosimetry is required to ensure the safety of molecular radiotherapy and to predict response. Dosimetry involves several steps, the first of which is the determination of the activity of the radiopharmaceutical taken up by an organ/lesion over time. As uncertainties propagate along each of the subsequent steps (integration of the time-activity curve, absorbed dose calculation), establishing a reliable activity quantification is essential. The MRTDosimetry project was a European initiative to bring together expertise in metrology and nuclear medicine research, with one main goal of standardizing quantitative \(^{177}\)Lu SPECT/CT imaging based on a calibration protocol developed and tested in a multicentre inter-comparison. This study presents the setup and results of this comparison exercise. Methods The inter-comparison included nine SPECT/CT systems. Each site performed a set of three measurements with the same setup (system, acquisition and reconstruction): (1) Determination of an image calibration for conversion from counts to activity concentration (large cylinder phantom), (2) determination of recovery coefficients for partial volume correction (IEC NEMA PET body phantom with sphere inserts), (3) validation of the established quantitative imaging setup using a 3D printed two-organ phantom (ICRP110-based kidney and spleen). In contrast to previous efforts, traceability of the activity measurement was required for each participant, and all participants were asked to calculate uncertainties for their SPECT-based activities. Results Similar combinations of imaging system and reconstruction lead to similar image calibration factors. The activity ratio results of the anthropomorphic phantom validation demonstrate significant harmonization of quantitative imaging performance between the sites with all sites falling within one standard deviation of the mean values for all inserts. Activity recovery was underestimated for total kidney, spleen, and kidney cortex, while it was overestimated for the medulla. Conclusion This international comparison exercise demonstrates that harmonization of quantitative SPECT/CT is feasible when following very specific instructions of a dedicated calibration protocol, as developed within the MRTDosimetry project. While quantitative imaging performance demonstrates significant harmonization, an over- and underestimation of the activity recovery highlights the limitations of any partial volume correction in the presence of spill-in and spill-out between two adjacent volumes of interests.}, language = {en} } @article{TranGiaDenisBacelarFerreiraetal.2023, author = {Tran-Gia, Johannes and Denis-Bacelar, Ana M. and Ferreira, Kelley M. and Robinson, Andrew P. and Bobin, Christophe and Bonney, Lara M. and Calvert, Nicholas and Collins, Sean M. and Fenwick, Andrew J. and Finocchiaro, Domenico and Fioroni, Federica and Giannopoulou, Katerina and Grassi, Elisa and Heetun, Warda and Jewitt, Stephanie J. and Kotzasarlidou, Maria and Ljungberg, Michael and Louren{\c{c}}o, Val{\´e}rie and McGowan, Daniel R. and Mewburn-Crook, Jamie and Sabot, Benoit and Scuffham, James and Sj{\"o}green Gleisner, Katarina and Solc, Jaroslav and Thiam, Cheick and Tipping, Jill and Wevrett, Jill and Lassmann, Michael}, title = {On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT/CT calibration: a European multi-centre evaluation}, series = {EJNMMI Physics}, volume = {10}, journal = {EJNMMI Physics}, organization = {The MRT Dosimetry Collaboration}, doi = {10.1186/s40658-023-00582-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-357740}, year = {2023}, abstract = {Introduction Commissioning, calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple sources of uncertainty, many of which can be overcome by using traceable, sealed, long-lived surrogate sources containing a radionuclide of comparable energies and emission probabilities. This study presents the results of a quantitative SPECT/CT imaging comparison exercise performed within the MRTDosimetry consortium to assess the feasibility of using 133Ba as a surrogate for 131I imaging. Materials and methods Two sets of four traceable 133Ba sources were produced at two National Metrology Institutes and encapsulated in 3D-printed cylinders (volume range 1.68-107.4 mL). Corresponding hollow cylinders to be filled with liquid 131I and a mounting baseplate for repeatable positioning within a Jaszczak phantom were also produced. A quantitative SPECT/CT imaging comparison exercise was conducted between seven members of the consortium (eight SPECT/CT systems from two major vendors) based on a standardised protocol. Each site had to perform three measurements with the two sets of 133Ba sources and liquid 131I. Results As anticipated, the 131I pseudo-image calibration factors (cps/MBq) were higher than those for 133Ba for all reconstructions and systems. A site-specific cross-calibration reduced the performance differences between both radionuclides with respect to a cross-calibration based on the ratio of emission probabilities from a median of 12-1.5\%. The site-specific cross-calibration method also showed agreement between 133Ba and 131I for all cylinder volumes, which highlights the potential use of 133Ba sources to calculate recovery coefficients for partial volume correction. Conclusion This comparison exercise demonstrated that traceable solid 133Ba sources can be used as surrogate for liquid 131I imaging. The use of solid surrogate sources could solve the radiation protection problem inherent in the preparation of phantoms with 131I liquid activity solutions as well as reduce the measurement uncertainties in the activity. This is particularly relevant for stability measurements, which have to be carried out at regular intervals.}, language = {en} } @inproceedings{WernerLapaBucketal.2017, author = {Werner, Rudolf and Lapa, Constantin and Buck, Andreas and Lassmann, Michael and H{\"a}nscheid, Heribert}, title = {Less is sometimes more - Accurate Dose Mapping after Endoradiotherapy with \(^{177}\)Lu-DOTATATE/-TOC by One-Single Measurement after 96 h}, series = {Journal of Nuclear Medicine}, volume = {58}, booktitle = {Journal of Nuclear Medicine}, number = {No. Supplement 1}, publisher = {Society of Nuclear Medicine and Molecular Imaging}, issn = {0161-5505}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-161168}, pages = {247}, year = {2017}, abstract = {No abstract available.}, language = {en} } @article{BeykanDamEberleinetal.2016, author = {Beykan, Seval and Dam, Jan S. and Eberlein, Uta and Kaufmann, Jens and Kj{\ae}rgaard, Benedict and J{\o}dal, Lars and Bouterfa, Hakim and Bejot, Romain and Lassmann, Michael and Jensen, Svend Borup}, title = {\(^{177}\)Lu-OPS201 targeting somatostatin receptors: in vivo biodistribution and dosimetry in a pig model}, series = {EJNMMI Research}, volume = {6}, journal = {EJNMMI Research}, number = {50}, doi = {10.1186/s13550-016-0204-9}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-146888}, year = {2016}, abstract = {Background \(^{177}\)Lu is used in peptide receptor radionuclide therapies for the treatment of neuroendocrine tumors. Based on the recent literature, SST2 antagonists are superior to agonists in tumor uptake. The compound OPS201 is the novel somatostatin antagonist showing the highest SST2 affinity. The aim of this study was to measure the in vivo biodistribution and dosimetry of \(^{177}\)Lu-OPS201 in five anesthetized Danish Landrace pigs as an appropriate substitute for humans to quantitatively assess the absorbed doses for future clinical applications. Results \(^{177}\)Lu-OPS201 was obtained with a specific activity ranging from 10 to 17 MBq/μg. Prior to administration, the radiochemical purity was measured as s > 99.7 \% in all cases. After injection, fast clearance of the compound from the blood stream was observed. Less than 5 \% of the injected activity was presented in blood 10 min after injection. A series of SPECT/CT and whole-body scans conducted until 10 days after intravenous injection showed uptake mostly in the liver, spine, and kidneys. There was no visible uptake in the spleen. Blood samples were taken to determine the time-activity curve in the blood. Time-activity curves and time-integrated activity coefficients were calculated for the organs showing visible uptake. Based on these data, the absorbed organ dose coefficients for a 70-kg patient were calculated with OLINDA/EXM. For humans after an injection of 5 GBq \(^{177}\)Lu-OPS201, the highest predicted absorbed doses are obtained for the kidneys (13.7 Gy), the osteogenic cells (3.9 Gy), the urinary bladder wall (1.8 Gy), and the liver (1.0 Gy). No metabolites of 177Lu-OPS201 were found by radio HPLC analysis. None of the absorbed doses calculated will exceed organ toxicity levels. Conclusions The \(^{177}\)Lu-OPS201 was well tolerated and caused no abnormal physiological or behavioral signs. In vivo distributions and absorbed doses of pigs are comparable to those observed in other publications. According to the biodistribution data in pigs, presented in this work, the expected radiation exposure in humans will be within the acceptable range.}, language = {en} } @article{IsaiasSpiegelBrumbergetal.2014, author = {Isaias, Ioannis Ugo and Spiegel, J{\"o}rg and Brumberg, Joachim and Cosgrove, Kelly P. and Marotta, Giorgio and Oishi, Naoya and Higuchi, Takahiro and K{\"u}sters, Sebastian and Schiller, Markus and Dillmann, Ulrich and van Dyck, Christopher H. and Buck, Andreas and Herrmann, Ken and Schloegl, Susanne and Volkmann, Jens and Lassmann, Michael and Fassbender, Klaus and Lorenz, Reinhard and Samnick, Samuel}, title = {Nicotinic acetylcholine receptor density in cognitively intact subjects at an early stage of Parkinson's disease}, series = {Frontiers in Aging Neuroscience}, volume = {6}, journal = {Frontiers in Aging Neuroscience}, doi = {10.3389/fnagi.2014.00213}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-119351}, pages = {213}, year = {2014}, abstract = {We investigated in vivo brain nicotinic acetylcholine receptor (nAChR) distribution in cognitively intact subjects with Parkinson's disease (PD) at an early stage of the disease. Fourteen patients and 13 healthy subjects were imaged with single photon emission computed tomography and the radiotracer 5-[(123)I]iodo-3-[2(S)-2-azetidinylmethoxy]pyridine ([(123)I]5IA). Patients were selected according to several criteria, including short duration of motor signs (<7 years) and normal scores at an extensive neuropsychological evaluation. In PD patients, nAChR density was significantly higher in the putamen, the insular cortex and the supplementary motor area and lower in the caudate nucleus, the orbitofrontal cortex, and the middle temporal gyrus. Disease duration positively correlated with nAChR density in the putamen ipsilateral (ρ = 0.56, p < 0.05) but not contralateral (ρ = 0.49, p = 0.07) to the clinically most affected hemibody. We observed, for the first time in vivo, higher nAChR density in brain regions of the motor and limbic basal ganglia circuits of subjects with PD. Our findings support the notion of an up-regulated cholinergic activity at the striatal and possibly cortical level in cognitively intact PD patients at an early stage of disease.}, language = {en} } @article{EberleinBroeerVandevoordeetal.2011, author = {Eberlein, Uta and Br{\"o}er, J{\"o}rn Hendrik and Vandevoorde, Charlot and Santos, Paula and Bardi{\`e}s, Manuel and Bacher, Klaus and Nosske, Dietmar and Lassmann, Michael}, title = {Biokinetics and dosimetry of commonly used radiopharmaceuticals in diagnostic nuclear medicine - a review}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {38}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {12}, doi = {10.1007/s00259-011-1904-z}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-133846}, pages = {2269-2281}, year = {2011}, abstract = {Purpose The impact on patients' health of radiopharmaceuticals in nuclear medicine diagnostics has not until now been evaluated systematically in a European context. Therefore, as part of the EU-funded Project PEDDOSE.NET (www.​peddose.​net), we review and summarize the current knowledge on biokinetics and dosimetry of commonly used diagnostic radiopharmaceuticals. Methods A detailed literature search on published biokinetic and dosimetric data was performed mostly via PubMed (www.​ncbi.​nlm.​nih.​gov/​pubmed). In principle the criteria for inclusion of data followed the EANM Dosimetry Committee guidance document on good clinical reporting. Results Data on dosimetry and biokinetics can be difficult to find, are scattered in various journals and, especially in paediatric nuclear medicine, are very scarce. The data collection and calculation methods vary with respect to the time-points, bladder voiding, dose assessment after the last data point and the way the effective dose was calculated. In many studies the number of subjects included for obtaining biokinetic and dosimetry data was fewer than ten, and some of the biokinetic data were acquired more than 20 years ago. Conclusion It would be of interest to generate new data on biokinetics and dosimetry in diagnostic nuclear medicine using state-of-the-art equipment and more uniform dosimetry protocols. For easier public access to dosimetry data for diagnostic radiopharmaceuticals, a database containing these data should be created and maintained.}, language = {en} }